Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Optical Properties of Nanosatellite Hardware

Over the last decade, a number of very small satellites have been launched into space. These have been called nanosatellites (generally of a weight between 1 and 10 kg) or picosatellites (weight <1 kg). This also includes CubeSats, which are based on 10-cm cube units. With the addition of the Japanese Experiment Module (JEM) Small Satellite Orbital Deployer (J-SSOD) to the International Space Station (ISS), CubeSats are easily cycled through the JEM airlock and deployed into space (fig. 1). The number of CubeSats launched since 2003 was approaching 100 at the time of publication, and the authors expect this trend in research to continue, particularly for high school and college flight experiments. Because these spacecraft are so small, there is usually no allowance for shielding or active heating or cooling of the avionics and other hardware. Parts that are usually ignored in the thermal analysis of larger spacecraft may contribute significantly to the heat load of a tiny satellite. In addition, many small satellites have commercial-off-the-shelf (COTS) components. To reduce costs, many providers of COTS components do not include the optical and physical parameters necessary for accurate thermal analysis. Marshall Space Flight Center participated in the development and analysis of the Space Missile Defense Command-Operational Nanosatellite Effect (SMDC-ONE) and the Edison Demonstration of Smallsat Networks (EDSN) nanosatellites. These optical property measurements are documented here in hopes that they may benefit future nanosatellite and picosatellite programs and aid thermal analysis to ensure project goals are met, with the understanding that material properties may vary by vendor, batch, manufacturing process, and preflight handling. Where possible, complementary data are provided from ground simulations of the space environment and flight experiments, such as the Materials on International Space Station Experiment (MISSE) series. NASA gives no recommendation, endorsement, or preference, either expressed or implied, concerning materials and vendors used. Solar absorptance was calculated from spectral reflectance measurements made from 250 to 2,800 nm with an AZ Technology Laboratory Portable Spectroreflectometer (LPSR) model 300. ASTM E-903 was the test method used under normal laboratory conditions, and ASTM E-490 was the solar spectral irradiance data used to calculate solar absorptance. Most of the samples were flat, but stray light was minimized as much as possible with either a blackbody or black cloth as sample background. The LPSR has repeatability of approximately +/-1%, where solar absorptance is given as range, that is, from actual measurements taken across the sample. Infrared emittance measurements were made with an AZ Technology TEMP 2000A infrared reflectometer. This instrument measures the total hemispheric reflectance averaged over 3-35 micrometer wavelengths. ASTM E-408 was the test method used under normal laboratory conditions. 3 Stray light was minimized as much as possible. The TEMP 2000A has repeatability of approximately +/-0.5%, where infrared emittance is given as a range, that is, from actual measurements taken across the sample.

Finckenor, M. M.↗

Pipeline for Applications-Based Data Discovery

From disaster response and mitigation to monitoring water quality or protecting wildlife habitat, satellite Earth observation data can be applied in countless ways to meet pressing needs and benefit society. The crucial first step toward successful data application is data discovery. Potential users often know exactly what data they need--what Earth feature or phenomenon they need to observe, how frequently, and at what resolution or level of accuracy--but may still struggle to discover the existing observations that meet their needs. We have developed a pipeline to connect applications-based users to specific satellites and data collections within NASA's Earth observation program of record that are highly relevant to their data needs. This pipeline combines available information on satellite and instrument measurement characteristics with an innovative machine learning-based approach that identifies instruments that are most relevant to the feature or phenomenon of interest.

Katrina S Virts↗

Remote sounding of tropospheric minor constituents

The etalon interferometer, or Fabry-Perot interferometer (FPI), with its high throughput and high spectral resolution was widely used in the remote-sensing measurements of the earth's atmospheric composition, winds, and temperatures. The most recent satellite instruments include the Fabry-Perot interferometer flown on the Dynamics Explorer-2 (DE-2) and the High Resolution Doppler Imager (HRDI) to be flown on the Upper Atmosphere Research Satellite (UARS). These instruments measure the Doppler line profiles of the emission and absorption of certain atmospheric species (such as atomic oxygen) in the visible spectral region. The successful space flight of DE-FPI and the test and delivery of UARS-HRDI demonstrated the extremely high spectral resolution and ruggedness of the etalon system for the remote sensing of earth and planetary atmospheres. Recently, an innovative FPI focal plane detection technique called the Circle-to-Line Interferometer Optical (CLIO) system was invented at the Space Physics Research Laboratory (SPRL). The CLIO simplifies the FPI focal plane detection process by converting the circular rings or fringes into a linear pattern similar to that produced by a conventional spectrometer, while retaining the throughput advantage of the etalon interferometer. CLIO makes the use of linear array detectors more practical and efficient with FPI, the combination of FPI and CLIO represents a very promising new technique for the remote sensing of the lower atmospheres of Earth, Mars, Venus, Neptune, and other planets. The Multiorder Etalon Spectrometer (MOES), as a combination of the rugged etalon and the CLIO, compares very favorably to other spaceborne optical instruments in terms of performance versus complexity. The feasibility of an advanced etalon spectrometer for the remote sensing of tropospheric trace species, particularly carbon monoxide (CO), nitrous oxide (N2O), and methane (CH4) was discussed. The etalon atmospheric spectroscopy techniques are described, instrument design and related technical issues are discussed. The primary objective is to establish the concept of atmospheric spectroscopy with the CLIO and etalon system and its applications for the measurements of tropospheric trace species analyze system requirements and performance, determine the feasibility of components and subsystem implementation with available technology, and develop inversion algorithm for retrieval simulation and data analysis.

Drayson, S. Roland↗

Field measurement of reflectance - Some major considerations

The simultaneous use of two portable spectroradiometers to measure radiance and irradiance from crop fields is reported. Two sensors were employed to assess the crop cover radiance reflectance, while a third instrument measured irradiance from a white Lambertian reflectance target, with all radiometers being equipped with optic fiber probes. Calibration procedures for the instruments are outlined, including the usage of laboratory standards and recalibration before every test by exposing all sensors to the Lambertian reflector. Calculation of the angular geometry between the sun, target, and sensor was found to be necessary to determine the angle dependence for each wave band and the surface variability. It is recommended that suitable portable equipment be fabricated with calibration procedures and manuals that can be used by the nonelectrical engineer in order to standardize measurements for comparison between two instruments.

Duggin, M. J.↗

Nimbus-7 Total Ozone Mapping Spectrometer (TOMS) Data Products User's Guide

Two data products from the Total Ozone Mapping Spectrometer (TOMS) onboard Nimbus-7 have been archived at the Distributed Active Archive Center, in the form of Hierarchical Data Format files. The instrument measures backscattered Earth radiance and incoming solar irradiance; their ratio is used in ozone retrievals. Changes in the instrument sensitivity are monitored by a spectral discrimination technique using measurements of the intrinsically stable wavelength dependence of derived surface reflectivity. The algorithm to retrieve total column ozone compares measured Earth radiances at sets of three wavelengths with radiances calculated for different total ozone values, solar zenith angles, and optical paths. The initial error in the absolute scale for TOMS total ozone is 3 percent, the one standard deviation random error is 2 percent, and drift is less than 1.0 percent per decade. The Level-2 product contains the measured radiances, the derived total ozone amount, and reflectivity information for each scan position. The Level-3 product contains daily total ozone amount and reflectivity in a I - degree latitude by 1.25 degrees longitude grid. The Level-3 product also is available on CD-ROM. Detailed descriptions of both HDF data files and the CD-ROM product are provided.

McPeters, Richard D.↗

Dual-frequency (Ka-band and G-band) radar estimates of liquid water content profiles in shallow clouds

The profile of the liquid water content (LWC) in clouds provides fundamental information for understanding the internal structure of clouds, their radiative effects, propensity to precipitate, and degree of entrainment and mixing with the surrounding environment. In principle, differential absorption techniques based on coincident dual-frequency radar reflectivity observations have the potential to provide the LWC profile. Previous differential frequency radar reflectivity (DFR) efforts were challenged by the fact that the measurable differential attenuation for small quantities of LWC is usually comparable to the system measurement error. This typically renders the retrieval impractical, as the uncertainty can become many times greater than the retrieved value itself. Theoretically, this drawback can be mitigated following two interconnected approaches: (1) increasing the frequency separation between the dual-frequency radar system to measure greater differential attenuation and (2) increasing the radar operating frequency to reduce the instrument measurement random error. Our recently developed 239 GHz radar was deployed during the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE) along with a variety of collocated remote sensing and in situ instruments. We have combined Ka-band (35 GHz) and G-band (239 GHz) observations to retrieve the LWC from more than 100 vertical profiles of shallow clouds with typical amounts of LWC smaller than 1 g m -3 . We theoretically and experimentally demonstrate that the Ka-band and G-band pair of frequencies offers at least a 65 % relative improvement in the LWC retrieval sensitivity compared to previous works reported in the literature using lower-frequency radars. This new technique provides a missing capability to determine the LWC in the challenging low liquid water path (LWP) range (< 200 g m -2 ) and suggests a way forward to characterize microphysical and dynamical processes more precisely in shallow clouds.

54 ENVIRONMENTAL SCIENCES↗

NASA Ames Flight Instrument Group - MARS Exploration Efforts Overview

The NASA Ames Flight Instrument Group (FIG) MARS development activities include Aeolus, an integrated multi-probe mission to observe surface and atmospheric forcing and general circulation of Mars; the Mars Sonic Anemometer (MSA), a sonic-based, in-situ wind measuring instrument and the Saltation Sensor to detect the critical wind stress threshold for sand motion, which is believed to be a key aspect of dust lifting at Mars. These efforts are readying the instruments to fly, and their measurements are regarded as data of high scientific priority for future flight missions. Each of these efforts focuses on addressing a measurement or capability considered critical within the Agency and traceable to the decadal survey and MEPAG Goals. As we elevate the Technology Readiness Level (TRL) of these instruments to 6 through rigorous environmental testing, and participate in forming mission concepts, we make them viable for inclusion in flight mission proposals. Below, we outline FIG's highest priority advancements for Mars exploration.

Mars↗

Using Cross-Correlations of SEUs and AP8 as a Diagnostic Tool

Timely data on low altitude energetic protons is very important for predicting the effect on humans and satellites. Because of the high bioeffectivity of protons in tissue, determination of the geographical location of the south Atlantic anomally (SAA) would be especially useful for reducing the risk associated with extravehicular activities. Because the AP8 model was developed with an epoch several decades old, the location of the south Atlantic anomally is incorrectly positioned in the model. The lack of extensive present-epoch energetic proton data at low altitude has prevented the update of the AP8 proton model. While there are studies in progress which are attempting to update the model at low altitude by using the path-integrated column density of the residual atmosphere as an organizing parameter, success in those studies will be defined by consistency in organization of old data. New data will still be required to provide a good present epoch model. As an alternative to using instrumental measurements of proton fluxes, background effects, proxy data sets such as SEUs, anomalies in instruments, enhanced background in shielded sensors believed to be induced by high energy protons, and dosimeter data in which key parameters (energy, efficiency, geometric factor, shielding, etc.) are poorly known can also be used. This in situ data is not as precise as direct measurement of the proton flux as geometric factor and shielding etc. are not calibrated, but these factors do not affect determination of the location of the SAA.

Vampola, A. L.↗

AmeriFlux FLUXNET-1F US-xSP NEON Soaproot Saddle (SOAP)

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-xSP NEON Soaproot Saddle (SOAP). This is the FLUXNET version of the carbon flux data for the site US-xSP NEON Soaproot Saddle (SOAP) produced by applying the standard ONEFlux (1F) software. Site Description - The Soaproot Saddle is a complex terrain of coarse hills, steep slopes and narrow drainages. With an elevation of 3274 - 4537’ this site encompasses 1438 acres of mixed conifer forests that are experiencing high levels of mortality due to native Pine beetles. At the core of this site stands a 171’ tall flux tower that collects physical and chemical properties of atmosphere and related process. Soaproot Saddle also hosts an array of sensor measurements along with field observations collected by highly trained NEON staff. The automated instrument measurements and some of the terrestrial observational safor this field site are colocted with NEON's aquatic site, Upper Big Creek, which is located just north of Soaproot Saddle's site boundaries.

Network), NEON (National Ecological Observatory [N↗

Effluent sampling of Scout D and Delta launch vehicle exhausts

Characterization of engine-exhaust effluents (hydrogen chloride, aluminum oxide, carbon dioxide, and carbon monoxide) has been attempted by conducting field experiments monitoring the exhaust cloud from a Scout-Algol III vehicle launch and a Delta-Thor vehicle launch. The exhaust cloud particulate size number distribution (total number of particles as a function of particle diameter), mass loading, morphology, and elemental composition have been determined within limitations. The gaseous species in the exhaust cloud have been identified. In addition to the ground-based measurements, instrumented aircraft flights through the low-altitude, stabilized-exhaust cloud provided measurements which identified CO and HCI gases and Al2O3 particles. Measurements of the initial exhaust cloud during formation and downwind at several distances have established sampling techniques which will be used for experimental verification of model predictions of effluent dispersion and fallout from exhaust clouds.

Hulten, W. C.↗

The MIT spectroscopy investigations on AXAF and the study of supernova remnants

The MIT High Resolution X-Ray Spectroscopy experiment on the AXAF, which will study physical conditions in celestial sources by means of detailed measurements of emission and absorption features in their spectra, involves two complementary dispersive instruments: Bragg Crystal Spectrometer (BCS) and High Energy Transmission Grating (HETG). This paper discusses the principles of operation of BCS and HETG and the results that will be obtained by these instruments. Measurements of individual line strengths obtained by the AXAF spectrometers will allow the application of plasma diagnostic techniques to a study of the detailed physical conditions in celestial objects, particularly in the optically thin plasma of supernova remnants, which is particularly well suited to the application of plasma diagnostics.

Canizares, C. R.↗

Actinometric measurement of j(O3-O(1D)) using a luminol detector

The photolysis frequency of ozone to singlet D oxygen atoms has been measured by means of a chemical actinometer using a luminol based detector. The instrument measures j(O3-O(1D)) with a precision of 10 percent. The data collected in winter and spring of 1991 is in agreement with model predictions and previously measured values. Data from a global solar radiometer can be used to estimate the effects of local cloudiness on j(O3-O(1D)).

Bairai, Solomon T.↗

An instrument for rapidly measuring plasma distribution functions with high resolution

An instrument which can rapidly measure plasma particle distribution functions has been developed based upon recent innovations in electrostatic analyzer design and position sensitive particle detection. The new analyzer uses a quadrispherical geometry, but has a completely uniform 360 deg fan-shaped field of view. The polar angular distribution of entering particles is spatially imaged onto a position sensitive detector at the annular exit aperture after a deflection through 90 deg. Several methods of position sensitive detection have been successfully used in conjunction with this analyzer. The simplest is individual channel multipliers spaced around the annular exit. Microchannel plate electron multipliers permit greater position resolution to be obtained, and a detector using microchannel plates followed by a resistive anode image converter obtains angular resolution of about one degree, i.e., 360 individual angle pixels. Instruments of this type were flown on a sounding rocket in early 1982 and will be included on the Giotto comet mission and the AMPTE ion release module (IRM).

Carlson, C. W.↗

Plasma diagnostics package measurements of ionospheric ions and Shuttle-induced perturbations

The plasma diagnostics package (PDP) on the Space Shuttle STS-3 mission in March 1982 carried among its instrument complement a retarding potential analyzer. This instrument measured both the ambient ion plasma density and temperature, and perturbations to the plasma produced by Shuttle Orbiter effects. Whenever the plasma flow streamline at the instrument was more than a distance of the order of thermal ion gyroradii away from any Orbiter surface, the measurements were characteristic of the ambient ionosphere. In several situations, the PDP was positioned so as to scan the wake in the plasma flow produced by Orbiter surfaces. The density profile of the major species O(+) was consistent with a classic Mach cone. However, strong perturbations extended for several meters outside the Mach cone, which resulted in failure of flowing Maxwellian distributions to represent the data. Configurations where the plasma-flow-impacted Orbiter surfaced downstream of the PDP resulted in generation of a suprathermal ion component. The observations are discussed in terms of a recent model of the mechanism for generation of Shuttle glow.

Reasoner, David L.↗

In situ measurements of particulate number density and size distribution from an aircraft

Two different commercial particulate measuring instruments were flown aboard the NASA Convair 990. A condensation nuclei monitor was utilized to measure particles larger than approximately 0.003 micron in diameter. A specially designed pressurization system was used with this monitor at cabin altitude pressure. A near-forward light scattering counter was used to measure the number and size distribution particles in the size range from 0.5 to 5 microns and greater in diameter. Considerable variation in number density was encountered for both classes of particles at the test altitudes ranging from 5 to 12 km. Presence of clouds could be detected by the light scattering instrument because large numbers of particles would then be registered by the instrument, especially in the size range above 5.0 microns in diameter.

Briehl, D.↗

Bulk Handling Facility Modeling and Simulation for Safeguards Analysis

The Separation and Safeguards Performance Model (SSPM) uses MATLAB/Simulink to provide a tool for safeguards analysis of bulk handling nuclear processing facilities. Models of aqueous and electrochemical reprocessing, enrichment, fuel fabrication, and molten salt reactor facilities have been developed to date. These models are used for designing the overall safeguards system, examining new safeguards approaches, virtually testing new measurement instrumentation, and analyzing diversion scenarios. The key metrics generated by the models include overall measurement uncertainty and detection probability for various material diversion or facility misuse scenarios. Safeguards modeling allows for rapid and cost-effective analysis for Safeguards by Design. The models are currently being used to explore alternative safeguards approaches, including more reliance on process monitoring data to reduce the need for destructive analysis that adds considerable burden to international safeguards. Machine learning techniques are being applied, but these techniques need large amounts of data for training and testing the algorithms. The SSPM can provide that training data. This paper will describe the SSPM and its use for applying both traditional nuclear material accountancy and newer machine learning options.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Gage for evaluating rheumatoid hands

Two-axis goniometer accurately measures movements of fingers about knuckle joints, diagnosing hands structurally changed by rheumatoid arthritis. Instrument measures lateral movement which is small in normal knuckles but increased in diseased joints. Goniometer is two connected protractors that simultaneously measure angles in perpindicular planes. Dials are offset to clear bony protuberances; extension and offset adjustments span any hand size.

Houge, J. C.↗

Measurements of gamma-ray line profiles from SN1987A and the structure of the ejecta

A few balloon-borne-instrument measurements of SN1987A's gamma-ray line profiles furnish the most direct indication of the distribution of freshly synthesized Co-56 radioactive material in the SN ejecta. Most of these profiles exhibit line shapes inconsistent with the standard, spherically symmetric and homogeneously mixed models, and are very similar to line profiles for IR lines of Fe observed prior to day 500 of the SN. The consistency of the line profile from IR to gamma-ray energies may reflect the distribution of freshly synthesized material in the expanding SN shell.

Tueller, J.↗