Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mechanical instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Space Shuttle Main Engine plume spectral monitoring preliminary results

In order to provide the information necessary to develop a rocket engine ground test failure detection monitor which keys on anomalous activity in the plume, a series of experimental observations were made during single engine Space Shuttle Main Engine (SSME) tests. The observations were conducted from the 220 nm wavelength in the ultraviolet out to the 15 micron wavelength in the infrared. Four types of instruments were employed including analog autoranging narrow band radiometers, optical multichannel analyzers, mechanical scanning and film plate spectrometers, and imaging cameras. Some results included: strong OH radiation in the UV up to vibrational transition state four; Na and K radiation lines in all phases of engine operation; reaction of some of the instruments to minor engine anomalies; good shock structure imaging; striations in the flow in the 310 nm OH band; and detection of gross changes in engine operating state such as start or shutdown.

Cikanek, H. A., III↗

A Mechanism for Precise Linear and Angular Adjustment Utilizing Flexures

This paper describes the design and development of a mechanism for precise linear and angular adjustment. This work was in support of the development of a mechanical extensometer for biaxial strain measurement. A compact mechanism was required which would allow angular adjustments about perpendicular axes with better than 10(exp -3) degree resolution. The approach adopted was first to develop a means of precise linear adjustment. To this end, a mechanism based on the toggle principle was built with inexpensive and easily manufactured parts. A detailed evaluation showed that the resolution of the mechanism was better than 1 micron and that adjustments made by using the device were repeatable. In the second stage of this work, the linear adjustment mechanisms were used in conjunction with a simple arrangement of flexural pivots and attachment blocks to provide the required angular adjustments. A series of experiments conducted with an autocollimator showed that the resolution of the mechanisms was better than 10(exp -3) degrees. Also, the mechanism met all requirements regarding size, weight, and mechanical simplicity. Attempts to use the mechanism in conjunction with the biaxial extensometer under development proved unsuccessful. Any form of in situ adjustment was found to cause erratic changes in instrument output. These changes were due to problems with the suspension system. However, the subject mechanism performed well in its own right and appeared to have potential for use in other applications. One important advantage of flexure based mechanisms is that they can be designed to operate independently of screw threads. This raises the possibility that they can be used for precise linear and angular adjustment in a space environment.

Ellis, J. R.↗

Composite Infrared Spectrometer (CIRS) on Cassini

The Cassini spacecraft orbiting Saturn carries the composite infrared spectrometer (CIRS) designed to study thermal emission from Saturn and its rings and moons. CIRS, a Fourier transform spectrometer, is an indispensable part of the payload providing unique measurements and important synergies with the other instruments. It takes full advantage of Cassini's 13-year-long mission and surpasses the capabilities of previous spectrometers on Voyager 1 and 2. The instrument, consisting of two interferometers sharing a telescope and a scan mechanism, covers over a factor of 100 in wavelength in the mid and far infrared. It is used to study temperature, composition, structure, and dynamics of the atmospheres of Jupiter, Saturn, and Titan, the rings of Saturn, and surfaces of the icy moons. CIRS has returned a large volume of scientific results, the culmination of over 30 years of instrument development, operation, data calibration, and analysis. As Cassini and CIRS reach the end of their mission in 2017, we expect that archived spectra will be used by scientists for many years to come.

Jennings, Donald E.↗

Magnetospheric Multiscale Mission Attitude Dynamics: Observations from Flight Data

Extensive flight data is being collected throughout the MMS mission that includes quantities that are of interest for attitude dynamics studies such as spin rate, spin axis orientation nutation rate, etc. One example of such data is the long-term evolution of the spin rates of the four spacecraft. Spikes in these rates are observed that are separated by the MMS orbital period (just under 24 hr) and occur around perigee due to gravity-gradient torque. Periodic discontinuities in spin rate are caused by the controller resetting the spin rate approximately to the nominal 3.1 RPM value at the time of each maneuver. In between, a slow decay in spin rate can be seen to occur. The paper will discuss various disturbance torque mechanisms that could potentially be responsible for this behavior: these include magnetic hysteresis, eddy currents, solar radiation pressure, and a possible interaction between gravity-gradient and wire boom flexibility effects. One additional disturbance mechanism is produced by the Active Spacecraft Potential Control (ASPOC) devices: these emit positive indium ions to keep the MMS spacecraft electrically neutral, so as not to corrupt the electric field observations that are made by some of the on-board instruments. The spin rate decays that could be produced by these various mechanisms will be quantified in the paper, and their signatures described. Comparing these with the observations from flight data then allow the most likely candidate to be determined.

DYNAMICS↗

Sensor deployment mechanism for Surfer satellite

A design is presented for a sensor-deployment mechanism to be used aboard the Surfer satellite, from which scientific instruments will be extended to study the earth ionosphere during the Space Shuttle Tether Experiment. The design discussed uses four folding arms to extend the radial sensors, as well as two storable tubular extendible members or spirally wound self-extending tube booms to project the axial sensors outward. The design solution chosen, a folding arm, is discussed in detail with attention to mechanical operation and component functions. Test program results are presented.

Dill, Robert↗

Test Bed for Investigating Anomalous Pump Behavior in a Single Phase Mechanically Pumped Flow Loop and Lessons Learned

NASA’s Europa Clipper mission is tasked with investigating the habitability of this icy moon of Jupiter and determining if it is capable of supporting life. The suite of powerful instruments necessary for this mission, combined with the harsh environment, require an elaborate single phase, mechanically pumped flow loop (MPFL) to redistribute waste heat around the spacecraft, thus minimizing energy requirements and avoiding the need for constant heating of the propulsion tanks. At the heart of this MPFL is a pump which will circulate fluid for the entirety of the 12-year mission; however, during initial qualification testing, anomalous behavior raised serious concerns regarding the pump and system design. Due to the critical nature of the pump, a major investigation was launched to evaluate the pump, system design, and the testing methodology employed to investigate this anomaly. This investigation resulted in a highly detailed analysis of the test loop, revised procedures, and the isolation/removal of variables impacting the quality of the observed pump behavior. The resulting test loop permitted comprehensive monitoring of the pump in the MPFL, including: flow rate, inlet and outlet static pressures, temperature, power consumption, and pump speed. Additionally, the investigation of the anomaly revealed several key lessons learned and helped institute a new set of best practices for future MPFL tests.

Miers, Collier↗

Pointing/roll mechanism for the ultraviolet coronagraph spectrometer

A pointing/roll mechanism for the Ultraviolet Coronagraph Spectrometer (UVCS) is presented along with a description of the mechanism control algorithm. The mechanism, operating in space, will position the 2.1 meter long, 0.7 meter diameter UVCS instrument in pitch and yaw, within a 54 arc-minute half angle cone, and will also allow it to rotate + or - 179.75 deg. After considerable design effort, an optimum mechanical solution was achieved, which meets all scientific requirements as well as weight, volume, and power budgets. Evolution of the mechanism is presented along with the design status.

Ostaszewski, Miroslaw A.↗

A Low-Frequency Generator

The need for a stable source of low-frequency power is often encountered in studies of recording-instruments performance. Indeed, in laboratory work involving the design and analysis of servo mechanisms in general, a low-frequency signal source is of paramount importance. The generator described herein was designed specifically to serve as a signal source for determination of the frequency characteristics of the various recording instruments in use at this Laboratory. Flexibility and convenience of operation in the dynamic testing of recording instruments characterize the generator which has been evolved.

Burke, J. J.↗

Analysis of Pyrolysis Products from Ablative Thermal Protection Systems

NASA’s state-of-the-art ablative materials are composed of a three-dimensional network of carbon fibers impregnated with polymers that dissipate thermal energy through pyrolysis. A fundamental understanding of the decomposition mechanisms and pyrolysis product distributions of various classes of polymers is instrumental in the design of new ablative materials. Furthermore, innovative experiments are essential to the continuous modernization of material response models by providing high-fidelity data. Thus, an apparatus has been designed to measure pyrolysis products from polymers and composite materials by implementing in-situ mass spectrometric techniques. Initial results from experiments performed on siloxane resins and a common phenolic resin will be discussed. Both classes of polymers exhibit heating-rate-dependent decomposition mechanisms. At the onset of heating, phenolic polymers decompose through competitive reactions to form gaseous products and a carbonaceous char. Gas phase products of phenolic resins are typically composed of molecular hydrogen, water, and aromatic hydrocarbons. Pyrolysis products from siloxane polymers include molecular hydrogen, small molecules, and cyclic oligomers from the polymer backbone.

Pyrolysis↗

Analysis of Pyrolysis Products from Ablative TPS

NASA’s state-of-the-art ablative materials are composed of a three-dimensional network of carbon fibers impregnated with polymers that dissipate thermal energy through pyrolysis. A fundamental understanding of the decomposition mechanisms and pyrolysis product distributions of various classes of polymers is instrumental in the design of new ablative materials. Furthermore, innovative experiments are essential to the continuous modernization of material response models by providing high-fidelity data. Thus, an apparatus has been designed to measure pyrolysis products from polymers and composite materials by implementing in-situ mass spectrometric techniques. Initial results from experiments performed on siloxane resins and a common phenolic resin will be discussed. Both classes of polymers exhibit heating-rate-dependent decomposition mechanisms. At the onset of heating, phenolic polymers decompose through competitive reactions to form gaseous products and a carbonaceous char. Gas phase products of phenolic resins are typically composed of molecular hydrogen, water, and aromatic hydrocarbons. Pyrolysis products from siloxane polymers include molecular hydrogen, small molecules, and cyclic oligomers from the polymer.

Pyrolysis↗

Development of a reclosable clamshell nose fairing for sounding rocket NASA 21.003UI

A reclosable clamshell noise fairing system was developed and successfully flown on a Black Brant VC sounding rocket. The clamshell system involved the design of unique structural and mechanical subsystems to meet the experimenters requirements, withstand environmental conditions of sounding rocket flight and recovery, and be relatively easy to maintain with a clean interface between the experiment detectors and instrumentation section of the payload. The development of the equations of motion of the mechanism are illustrated and results of the test of the Engineering Test Model (ETM) are shown.

Ferragut, N. J.↗

Mechanical aids to flight

This report examines the great utility and safety of using instruments when flying. Instruments can be especially useful in conditions when the pilot has trouble spatially orienting himself.

Warner, Edward P↗

System for Multiplexing Acoustic Emission (AE) Instrumentation

An acoustic monitoring device has at least two acoustic sensors with a triggering mechanism and a multiplexing circuit. After the occurrence of a triggering event at a sensor, the multiplexing circuit allows a recording component to record acoustic emissions at adjacent sensors. The acoustic monitoring device is attached to a solid medium to detect the occurrence of damage.

Prosser, William H.↗

Temperature, age and crust thickness distributions of Loki Patera on Io: implications for resurfacing mechanism

A high-spatial-resolution, multi-wavelength observation by the Galileo NIMS instrument has been analysed to determine the temperature and area distribution of a large portion of the ionian volcano Loki Patera. The temperatures of the cooler components from a two-temperature fit to the data can be used to determine ages of the surface. The age of the floor along a profile across the floor of the caldera ranges from ~10 to ~80 days. This puts the start of the resurfacing in July/early August 2001, yielding a resurfacing rate of approximately 1 km/day, with the new lava spreading from the SW corner of the caldera in a NE direction. This rate is consistent with resurfacing by foundering of the crust on a lava lake. However,the temperature distribution may also result from the emplacement of flows. Implied crust thicknesses (derived using a lava cooling model) range from 2.6 to 0.9 m.

jovian satellites Io volcanology↗

The flight instrument design for the Terrestrial Planet Finder Interferometer

This paper describes the opto-mechanical systems of the telescopes and beramcombiner spacecraft including the wavefront and optical path control devices and alignment systems. The mechanical layouts of the spacecraft are described along with the predicted performance of the structure in terms of thermal and vibration control. The layout of the control system is also described.

interferometry↗

The optics and calibration of the Venus solar flux radiometer

The described instrument is to measure the net solar radiation as a function of altitude as the probe descends through the Venus atmosphere. The data are to provide a basis for the study of the mechanisms which are responsible for the high surface temperature of the planet Venus. The instrument consists of two separate sections, including an optical head and an electronics package. The radiance is measured with silicon and indium arsenide detectors. Details of radiometer design are discussed along with the characteristics of the optical system and the detectors. Angular and radiometric calibration procedures are also considered.

Palmer, J. M.↗

A clamp mechanism for deployable three-ton payloads

The requirements, capabilities, and unique design features of the instrument payload subsystem payload clamp assembly (PCA) are presented. The PCA is designed to have the flexibility to accommodate a wide payload range varying from 0.5 m to 3 m in diameter and from 500 kg to 3000 kg mass. This is achieved by modular clamp design in connection with replaceable struts. The design features include clamping of payload in a statically determined way and actuation of clamp latches by means of single linear actuator via ropes. The vibration and TV environmental conditions for the mechanism are extremely severe. A structural and prototype model was built. Test results of the operating characteristic are presented. In addition, problems of tribology are highlighted.

Birner, R.↗

An improved logarithmic amplifier circuit for PDS microdensitometers

A high speed logarithmic amplifier circuit for the Perkin-Elmer PDS microdensitometer is discussed. The circuit is designed around an Analog Devices 757p log-amp module. The amplifier produces undistorted profiles of rapidly changing, dense ( 4) images over the available range of scanning speeds. The circuit board was designed to replace directly the manufacturer supplied unit; neither electrical nor mechanical modifications of the basic PDS are required. The performance of the circuit is illustrated through its effects on the overall modulation transfer function of the instrument and by scans of a well exposed stellar image. Circuit diagrams and parts lists a mechanism for obtaining either circuit board layout art work or finished circuit boards are presented.

Anderson, C. M.↗