Search NASA⌕ Search

SEARCH · Search NASA

Results for “Methods: data analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Data-driven method for electric vehicle charging demand analysis: Case study in Virginia

Electric vehicle (EV) adoption in the U.S. will be accelerated by the historic $7.5 billion public investments in EV charging infrastructure. Careful analysis of EV charging demands plays a vital role in understanding the energy requirements, power grid impact, and smart charging management opportunities of EVs. To this end, this paper develops a data-driven trip-chaining-based modeling framework including five steps: Trip data acquisition and preprocessing, EV adoption modeling, travel itinerary synthesis, EV charging demand simulation and EV load profile generation. The developed analysis framework was demonstrated using real-world data for one region in Virginia, U.S. The results show that the proposed modeling framework can work effectively. For the study region in 2040, the predicted number of plug-in EVs is 470,114, resulting in a weekly charging demand of 38,078,127 kWh (55% home, 9% work, and 36% public) in September and 45,920,358 kWh (61% home, 9% work, and 30% public) in February.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Multimodal X-ray nano-spectromicroscopy analysis of chemically heterogeneous systems

Abstract Understanding the nanoscale chemical speciation of heterogeneous systems in their native environment is critical for several disciplines such as life and environmental sciences, biogeochemistry, and materials science. Synchrotron-based X-ray spectromicroscopy tools are widely used to understand the chemistry and morphology of complex material systems owing to their high penetration depth and sensitivity. The multidimensional (4D+) structure of spectromicroscopy data poses visualization and data-reduction challenges. This paper reports the strategies for the visualization and analysis of spectromicroscopy data. We created a new graphical user interface and data analysis platform named XMIDAS (X-ray multimodal image data analysis software) to visualize spectromicroscopy data from both image and spectrum representations. The interactive data analysis toolkit combined conventional analysis methods with well-established machine learning classification algorithms (e.g. nonnegative matrix factorization) for data reduction. The data visualization and analysis methodologies were then defined and optimized using a model particle aggregate with known chemical composition. Nanoprobe-based X-ray fluorescence (nano-XRF) and X-ray absorption near edge structure (nano-XANES) spectromicroscopy techniques were used to probe elemental and chemical state information of the aggregate sample. We illustrated the complete chemical speciation methodology of the model particle by using XMIDAS. Next, we demonstrated the application of this approach in detecting and characterizing nanoparticles associated with alveolar macrophages. Our multimodal approach combining nano-XRF, nano-XANES, and differential phase-contrast imaging efficiently visualizes the chemistry of localized nanostructure with the morphology. We believe that the optimized data-reduction strategies and tool development will facilitate the analysis of complex biological and environmental samples using X-ray spectromicroscopy techniques.

36 MATERIALS SCIENCE↗

Learning Spectral Templates for Photometric Redshift Estimation from Broadband Photometry

Estimating redshifts from broadband photometry is often limited by how accurately we can map the colors of galaxies to an underlying spectral template. Current techniques utilize spectrophotometric samples of galaxies or spectra derived from spectral synthesis models. Both of these approaches have their limitations: either the sample sizes are small and often not representative of the diversity of galaxy colors, or the model colors can be biased (often as a function of wavelength), which introduces systematics in the derived redshifts. In this paper, we learn the underlying spectral energy distributions from an ensemble of ∼100 K galaxies with measured redshifts and colors. We show that we are able to reconstruct emission and absorption lines at a significantly higher resolution than the broadband filters used to measure the photometry for a sample of 20 spectral templates. We find that our training algorithm reduces the fraction of outliers in the derived photometric redshifts by up to 28%, bias up to 91%, and scatter up to 25%, when compared to estimates using a standard set of spectral templates. We discuss the current limitations of this approach and its applicability for recovering the underlying properties of galaxies. Our derived templates and the code used to produce these results are publicly available in a dedicated Github repository: https://github.com/dirac-institute/photoz-template-learning.

79 ASTRONOMY AND ASTROPHYSICS↗

Highly Selective and Stable Multivariable Gas Sensors for Enhanced Robustness and Reliability of SOFC Operation

GE Global Research, in partnership with SUNY Polytechnic Institute (SUNY Poly) and GE–Fuel Cells LLC, designed, built, and tested multi-gas sensor prototypes for in situ monitoring of gases produced during steam reforming in solid oxide fuel cell (SOFC) systems. To be widely adopted and to deliver a lower operating cost for customers, SOFC systems should enhance their operation reliability and improve stack robustness. These needs can be achieved by early diagnostics of potential upsets by using in-situ gas sensors for the real-time monitoring of gas mixture compositions. Thus, this project objective was to achieve selectivity and stability of sensing of gases for SOFC applications by implementing a new generation of gas sensors, known as multivariable sensors. Such sensors are intended to complement the mature traditional analytical instruments based on sensor performance and design characteristics. The key sensor-performance characteristics include accurate detection and quantitation of several gases in their mixtures and stability of operation in unattended applications. The key design characteristics of sensors include their unobtrusive form factor and cost-effectiveness. The duration of the project was 18 months with the project structure that included three technical tasks such as (1) design and laboratory validation of multivariable sensors for selective detection of H 2 and CO gases, (2) laboratory validation of sensor stability over a two-week testing, and (3) field-validation of the developed multivariable sensor system prototype at GE–Fuel Cells factory. Multi-gas detection was achieved with multivariable photonic sensors designed to operate at elevated temperature. The sensor design was based on three-dimensional (3D) bio-inspired photonic nanostructure that was fabricated using materials responsive to gases of interest such as H 2 and CO. The gas discrimination and the rejection of interferences such as CH 4 , H 2 O, and others was performed by optimizing the design parameters of the 3D photonic nanostructures such as their composition and morphology. Planar sol-gel and sputtered sensing films were fabricated as controls. As a result of the fabrication, functionalization, excitation, and performance testing of 3D photonic sensors, we developed initial design rules for high temperature multivariable sensors. These design rules pave the way for the new generation of cost-effective industrial sensors. Stability of sensor operation was tested in the laboratory conditions under variations of the ambient environments. Stability tests were designed in the order of enhanced complexity and realism of sensor operation and included quantitation of a single gas, quantitation of a single gas in the presence of interferences, and quantitation of two and three gases. We have found that conventional machine learning data analysis stools were unable to correct for the sensor drift. Thus, we have developed new methods of machine learning data analysis that provided us with needed performance stability. Such performance improvement in gas sensing was a significant milestone in bringing our multivariable sensors to practical applications. The project culminated with initial field validation of developed multivariable sensor prototypes at GE–Fuel Cells LLC. The in situ data generated by the sensor system in the lab and field conditions provided inputs that advanced our fundamental understanding of gas sensing at high temperatures to enable sensors for SOFC applications and allowed development of the recommendations for further deliverables.

47 OTHER INSTRUMENTATION↗

Surface analysis insight note: Differentiation methods applicable to noisy data for determination of sp2‐ versus sp3‐hybridization of carbon allotropes and AES signal strengths

The derivatives of the spectra are commonly used for quantification in Auger Electron Spectroscopy (AES) spectra, while the derivative of the KLL C Auger line has proven to be valuable in obtaining a measure of the relative proportions of sp 2 ‐ and sp 3 ‐hybridization using the D‐parameter in both AES and X‐ray Photoelectron Spectroscopy (XPS). Differentiation of X‐ray Photoelectron Spectroscopy (XPS) and Auger Electron Spectroscopy (AES) spectra by numerical means is presented and illustrated for polymeric, such as PEEK and Nylon, as well as for graphitic materials including highly ordered pyrolytic graphite and graphene oxide. The most commonly available Savitzky–Golay method is explained mathematically and developed through the case of constructing a 5‐point quadratic polynomial convolution kernel suitable for differentiating spectra of adequate signal to noise. The concept of differentiation of spectra where signal to noise is less than adequate is also developed. Two alternative strategies to Savitzky–Golay differentiation are presented, which fit curves to data that allow derivatives to be obtained where Savitzky–Golay would otherwise fail. These alternative methods involve constructing a parametric curve that fits data over the entire energy interval of interest. Derivatives of spectra are then obtained by differentiating these parametric curves directly. A comparison of results for different materials for which specific sp 2 ‐ vs sp 3 ‐hybridized carbon proportions are of interest is used to emphasize the importance of characterizing methods used to differentiate spectra and understanding the characteristics of instrumentation used to measure spectra. The case for using Principal Component Analysis noise reduction with C KLL spectra is made for spectra collected from a heterogeneous graphene oxide sample.

Fairley, Neal↗

EINSTEIN-HOME DISCOVERY OF 24 PULSARS IN THE PARKES MULTI-BEAM PULSAR SURVEY

We have conducted a new search for radio pulsars in compact binary systems in the Parkes multi-beam pulsar survey (PMPS) data, employing novel methods to remove the Doppler modulation from binary motion. This has yielded unparalleled sensitivity to pulsars in compact binaries. The required computation time of Almost-Equal-To 17, 000 CPU core years was provided by the distributed volunteer computing project Einstein-Home, which has a sustained computing power of about 1 PFlop s{sup -1}. We discovered 24 new pulsars in our search, 18 of which were isolated pulsars, and 6 were members of binary systems. Despite the wide filterbank channels and relatively slow sampling time of the PMPS data, we found pulsars with very large ratios of dispersion measure (DM) to spin period. Among those is PSR J1748-3009, the millisecond pulsar with the highest known DM ( Almost-Equal-To 420 pc cm{sup -3}). We also discovered PSR J1840-0643, which is in a binary system with an orbital period of 937 days, the fourth largest known. The new pulsar J1750-2536 likely belongs to the rare class of intermediate-mass binary pulsars. Three of the isolated pulsars show long-term nulling or intermittency in their emission, further increasing this growing family. Our discoveries demonstrate the value of distributed volunteer computing for data-driven astronomy and the importance of applying new analysis methods to extensively searched data.

79 ASTRONOMY AND ASTROPHYSICS↗

Search for Low-Mass Dark Matter with CDMSlite Using a Profile Likelihood Fit

The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) searches for interactions between dark matter particles and germanium nuclei in cryogenic detectors. The experiment has achieved a low energy threshold with improved sensitivity to low-mass (<10 GeV/c2) dark matter particles. We present an analysis of the final CDMSlite data set, taken with a different detector than was used for the two previous CDMSlite data sets. This analysis includes a data "salting" method to protect against bias, improved noise discrimination, background modeling, and the use of profile likelihood methods to search for a dark matter signal in the presence of backgrounds. We achieve an energy threshold of 70 eV and significantly improve the sensitivity for dark matter particles with masses between 2.5 and 10 GeV/c2 compared to previous analyses. We set an upper limit on the dark matter-nucleon scattering cross section in germanium of 5.4×10-42 cm2 at 5 GeV/c2, a factor of ~2.5 improvement over the previous CDMSlite result.

Agnese, R↗

Machine-learning-assisted automation of single-crystal neutron diffraction

Neutron scattering is a powerful but expensive technique to study materials and discover new matter. Advanced detector technology has significantly improved the efficiency of neutron experiments, increasing the complexity of neutron data reduction and analysis. Machine learning (ML) brings new directions for neutron diffraction data reduction and experiment operation. Here, this work presents an ML-assisted data reduction and analysis method for precise recognition of Bragg peaks and the corresponding regions of interest; it can then automatically screen and align a measured crystal using the recognized peaks, and subsequently plan and optimize the data collection with user-provided information and uncertainty quantification values of detected peaks. This method shows robust performance in different complex sample environments and enables automated single-crystal neutron diffraction.

47 OTHER INSTRUMENTATION↗

Dynamical Components Analysis (DCA) v1.0.0

Dynamical Components Analysis is a Python implementation of the method described in "Unsupervised discovery of temporal structure in noisy data with dynamical components analysis". It implements the method as well as related data analysis functions.

Livezey, Jesse↗

Dynamical Components Analysis (DCA) v1.0.0

Dynamical Components Analysis is a Python implementation of the method described in "Unsupervised discovery of temporal structure in noisy data with dynamical components analysis". It implements the method as well as related data analysis functions.

Livezey, Jesse↗

AFIP6-MkII and RERTR-12 Porosity Data Collection and Analysis for Modeling and Simulation

Gathering data for the improvement of nuclear fuel modeling and simulation efforts is the primary driver for this work. Mechanistic models allow for a better understanding of the material on a micro- and macrostructural level while saving time and money over traditional experiment efforts. Historically, summarized data and correlations are the inputs for empirical material models and model validation. When improving these models for nuclear fuels with experimental results, there is a lack of reliable data readily available. Experiments - RERTR-12 and AFIP6-MkII - were conducted to understand the irradiation behavior of metallic U-10Mo monolithic fuels for use in extreme reactor environments such as research reactors like the Advanced Test Reactor (ATR) or the High Flux Isotope Reactor (HFIR). Microstructural characteristics of fission gas pores (FGP) in each experiment are collected using an automated image analysis technique developed at the University of Florida and presented here. A series of statistical tests are performed to explore the reliability of the results, as well as understand where the data is lacking and what future data collection is necessary to provide sufficient information to assist modeling efforts. The focus is on the porosity, pore size, and eccentricity of FGPs formed during irradiation in three AFIP6-MkII samples and one RERTR-12 sample. From the analysis, it is clear there are substantial impacts of fission density on the pore structure, but there also exist also underlying connections between each sample and the behavior observed in the pores. Further analyses of the pre- and post-irradiation microstructure are needed to improve the understanding of these connections. An early method for microstructural data analysis is presented within and is currently being expanded to include other microstructure data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Enhancing e-waste estimates: Improving data quality by multivariate Input–Output Analysis

Highlights: • A multivariate Input–Output Analysis method for e-waste estimates is proposed. • Applying multivariate analysis to consolidate data can enhance e-waste estimates. • We examine the influence of model selection and data quality on e-waste estimates. • Datasets of all e-waste related variables in a Dutch case study have been provided. • Accurate modeling of time-variant lifespan distributions is critical for estimate. - Abstract: Waste electrical and electronic equipment (or e-waste) is one of the fastest growing waste streams, which encompasses a wide and increasing spectrum of products. Accurate estimation of e-waste generation is difficult, mainly due to lack of high quality data referred to market and socio-economic dynamics. This paper addresses how to enhance e-waste estimates by providing techniques to increase data quality. An advanced, flexible and multivariate Input–Output Analysis (IOA) method is proposed. It links all three pillars in IOA (product sales, stock and lifespan profiles) to construct mathematical relationships between various data points. By applying this method, the data consolidation steps can generate more accurate time-series datasets from available data pool. This can consequently increase the reliability of e-waste estimates compared to the approach without data processing. A case study in the Netherlands is used to apply the advanced IOA model. As a result, for the first time ever, complete datasets of all three variables for estimating all types of e-waste have been obtained. The result of this study also demonstrates significant disparity between various estimation models, arising from the use of data under different conditions. It shows the importance of applying multivariate approach and multiple sources to improve data quality for modelling, specifically using appropriate time-varying lifespan parameters. Following the case study, a roadmap with a procedural guideline is provided to enhance e-waste estimation studies.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DASSA v0.0.1

DASSA (Parallel DAS Data Storage and Analysis) provides a data storage engine and analysis engine for data from distributed acoustic sensing and other methods. It supports various data analysis operations, from FFT , signal filter, cross-correlation, compression, stacking etc.

Dong, Bin↗

A Bayesian method to estimate the neutron response matrix of a single crystal CVD diamond detector

Detectors made from artificial chemical vapor deposition (CVD) single crystal diamond are very promising candidates for applications where high resolution neutron spectrometry in very high neutron fluxes is required, for example in fusion research. We propose a Bayesian method to estimate the neutron response function of the detector for a continuous range of neutron energies (in our case, 10 MeV ≤ E{sub n} ≤ 16 MeV) based on a few measurements with quasi-monoenergetic neutrons. This method is needed because a complete set of measurements is not available and the alternative approach of using responses based on Monte Carlo calculations is not feasible. Our approach uses Bayesian signal-background separation techniques and radial basis function interpolation methods. We present the analysis of data measured at the PTB accelerator facility PIAF. The method is quite general and it can be applied to other particle detectors with similar characteristics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EP-DRAFT-1.1 2014-01-19 OSI-GAM-SOP-00x In Situ High-resolution Gamma Spectroscopy

The standard operating procedure is described for in situ high-resolution gamma spectroscopy, including operational readiness, planning, preparation, conduct, and reporting. Data analysis of in situ gamma spectrum files will be performed together with those of other gamma assay methods by a dedicated Data Analysis process, documented in companion OSI procedures.

07 ISOTOPE AND RADIATION SOURCES↗

RISMC Advanced Safety Analysis Project Plan – FY 2015 - FY 2019

In this report, a project plan is developed, focused on industry applications, using Risk-Informed Safety Margin Characterization (RISMC) tools and methods applied to realistic, relevant, and current interest issues to the operating nuclear fleet. RISMC focuses on modernization of nuclear power safety analysis (tools, methods and data); implementing state-of-the-art modeling techniques (which include, for example, enabling incorporation of more detailed physics as they become available); taking advantage of modern computing hardware; and combining probabilistic and mechanistic analyses to enable a risk informed safety analysis process. The modernized tools will maintain the current high level of safety in our nuclear power plant fleet, while providing an improved understanding of safety margins and the critical parameters that affect them. Thus, the set of tools will provide information to inform decisions on plant modifications, refurbishments, and surveillance programs, while improving economics. This set of tools will also benefit the design of new reactors, enhancing safety per unit cost of a nuclear plant. The proposed plan will focus on application of the RISMC toolkit, in particular, solving realistic problems of important current issues to the nuclear industry, in collaboration with plant owners and operators to demonstrate the usefulness of these tools in decision making.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗