Thermal hydraulic characteristics of liquid sodium and supercritical CO 2 in a diffusion bonded heat exchanger

Compact heat exchangers are being examined for use in advanced, high-temperature nuclear or concentrated solar power plants to improve thermal efficiencies and reduce capital costs. At the time of this work, no experimental investigation of liquid sodium in the popular diffusion-bonded heat exchanger design had been performed. Herein this paper describes the thermal-hydraulic and overall operations performance observed during testing of a 316/L stainless steel “zig-zag” microchannel heat exchanger operating between a (0.5 kg/s) sodium loop and a (0.3 kg/s) recuperated supercritical CO 2 system with outlet conditions up to 550 °C at 16 MPa. Observed pressure drop is presented in the form of an effective friction factor correlation which aligns closely with recent experimental data. The thermal performance of this heat exchanger, measured by its overall conductance under various flow conditions, was decomposed to examine the independent convection behaviors of both the CO 2 and sodium streams. These results are presented in the form of Nusselt correlations fitted to the experimental data. The sodium heat transfer correlation aligns closely with the widely accepted Lubarsky-Kaufman correlation, while the CO 2 heat transfer correlation lies between previous correlations developed by computational and experimental methods. This was the first long-duration use of sodium in a microchannels (~1.8 mm hydraulic diameter) heat exchanger. The use of an oxide control system enabled trouble-free operation of the heat exchanger for over 150 h of high-temperature operation. This first-of-a-kind demonstration using liquid sodium and supercritical carbon dioxide shows great promise for further application of this technology in advanced nuclear or solar power plants.

42 ENGINEERING↗

Effective property models for homogeneous two-phase flows

Using an analogy between thermal conductivity of porous media and viscosity in two-phase flow, new definitions for two-phase viscosity are proposed. These new definitions satisfy the following two conditions: namely (i) the two-phase viscosity is equal to the liquid viscosity at the mass quality = 0% and (ii) the two-phase viscosity is equal to the gas viscosity at the mass quality = 100%. These new definitions can be used to compute the two-phase frictional pressure gradient using the homogeneous modeling approach. These new models are assessed using published experimental data of two-phase frictional pressure gradient in circular pipes, minichannels and microchannels in the form of Fanning friction factor (f{sub m}) versus Reynolds number (Re{sub m}). The published data include different working fluids such as R-12, R-22, argon (R740), R717, R134a, R410A and propane (R290) at different diameters and different saturation temperatures. Models are assessed on the basis minimizing the root mean square error (e{sub RMS}). It is shown that these new definitions of two-phase viscosity can be used to analyze the experimental data of two-phase frictional pressure gradient in circular pipes, minichannels and microchannels using simple friction models. (author)

42 ENGINEERING↗

Designing slippery rough surfaces to enhance dropwise condensation of low surface tension fluid

Enhancing low surface tension liquid condensation is critical for achieving high energy efficiency and reducing the size of thermal energy systems. Extensive research has focused on promoting dropwise condensation of these liquids using state-of-the-art coatings on plain surfaces. However, maintaining dropwise condensation with low surface tension fluids is challenging due to rivulet formation, resulting in wetted tails that transition to filmwise condensation at elevated heat fluxes. Here, to address this issue, we uncover the role of surface structures and surface chemistry in the dropwise condensation of low surface tension ethanol on slippery rough surfaces (SRS). High-performance dropwise condensation has been achieved on slippery microchannels grafted with perfluoropolyether. The SRS uniquely facilitates rapid lateral droplet removal, enabling faster directional droplet shedding without rivulet formation. The resulting higher droplet removal frequency on SRS leads to heat transfer coefficients 100 % and 500 % higher than conventional dropwise and filmwise condensation on plain surfaces, respectively. Our findings uncover the pivotal role of rapid droplet removal through slippery microchannels in sustaining dropwise condensation of low surface tension liquids. This study introduces a new paradigm for promoting dropwise condensation using engineered SRS that incorporates surface structure and surface chemistry. The work will provide fundamental design guidelines to design efficient and compact condensers that use costly or flammable low global warming potential refrigerants in future refrigeration systems.

Dropwise condensation↗

Standard design for National Ignition Facility x-ray streak and framing cameras

The x-ray streak camera and x-ray framing camera for the National Ignition Facility were redesigned to improve electromagnetic pulse hardening, protect high voltage circuits from pressure transients, and maximize the use of common parts and operational software. Both instruments use the same PC104 based controller, interface, power supply, charge coupled device camera, protective hermetically sealed housing, and mechanical interfaces. Communication is over fiber optics with identical facility hardware for both instruments. Each has three triggers that can be either fiber optic or coax. High voltage protection consists of a vacuum sensor to enable the high voltage and pulsed microchannel plate phosphor voltage. In the streak camera, the high voltage is removed after the sweep. Both rely on the hardened aluminum box and a custom power supply to reduce electromagnetic pulse/electromagnetic interference (EMP/EMI) getting into the electronics. In addition, the streak camera has an EMP/EMI shield enclosing the front of the streak tube.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards hard x-ray imaging at GHz frame rate

Gigahertz (GHz) imaging using hard x-rays ( Greater-Than-Or-Equivalent-To 10 keV) can be useful to high-temperature plasma experiments, as well as research and applications using coherent photons from synchrotron radiation and x-ray free electron lasers. GHz framing rate can be achieved by using multiple cameras through multiplexing. The advantages and trade-offs of single-photon detection mode, when no more than one x-ray photon is detected per pixel, are given. Two possible paths towards x-ray imaging at GHz frame rates using a single camera are: (a) avalanche photodiode arrays of high-Z materials and (b) microchannel plate photomultipliers in conjunction with materials with large indices of refraction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A zero dead-time multi-particle time and position sensitive detector based on correlation between brightness and amplitude

A new multi-particle time and position sensitive detector using only a set of microchannel plates, a waveform digitizer, a phosphor screen, and a CMOS camera is described. The assignment of the timing information, as taken from the microchannel plates by fast digitizing, to the positions, as recorded by the camera, is based on the COrrelation between the BRightness of the phosphor screen spots, defined as their integrated intensity and the Amplitude of the electrical signals (COBRA). Tests performed by observing the dissociation of HeH, the fragmentation of H{sub 3} into two or three fragments, and the photo-double-ionization of Xenon atoms are presented, which illustrate the performances of the COBRA detection scheme.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microscale Enhancement of Heat and Mass Transfer for Hydrogen Energy Storage

The document summarized the technical progress associated with OSU’s involvement in the Hydrogen Storage Engineering Center of Excellence. OSU focused on the development of microscale enhancement technologies for improving heat and mass transfer in automotive hydrogen storage systems. OSU’s key contributions included the development of an extremely compact microchannel combustion system for discharging hydrogen storage systems and a thermal management system for adsorption based hydrogen storage using microchannel cooling (the Modular Adsorption Tank Insert or MATI).

08 HYDROGEN↗

High Frequency Design Considerations for the Large Detector Number and Small Form Factor Dual Electron Spectrometer of the Fast Plasma Investigation on NASA's Magnetospheric Multiscale Mission

Each half of the Dual Electron Spectrometer (DES) of the Fast Plasma Investigation (FPI) on NASA's Magnetospheric MultiScale (MMS) mission utilizes a microchannel plate Chevron stack feeding 16 separate detection channels each with a dedicated anode and amplifier/discriminator chip. The desire to detect events on a single channel with a temporal spacing of 100 ns and a fixed dead-time drove our decision to use an amplifier/discriminator with a very fast (GHz class) front end. Since the inherent frequency response of each pulse in the output of the DES microchannel plate system also has frequency components above a GHz, this produced a number of design constraints not normally expected in electronic systems operating at peak speeds of 10 MHz. Additional constraints are imposed by the geometry of the instrument requiring all 16 channels along with each anode and amplifier/discriminator to be packaged in a relatively small space. We developed an electrical model for board level interactions between the detector channels to allow us to design a board topology which gave us the best detection sensitivity and lowest channel to channel crosstalk. The amplifier/discriminator output was designed to prevent the outputs from one channel from producing triggers on the inputs of other channels. A number of Radio Frequency design techniques were then applied to prevent signals from other subsystems (e.g. the high voltage power supply, command and data handling board, and Ultraviolet stimulation for the MCP) from generating false events. These techniques enabled us to operate the board at its highest sensitivity when operated in isolation and at very high sensitivity when placed into the overall system.

Microchannel plates high frequency performance↗

Creating microfluidic channels functionalized with micro- and nano-scale features via femtosecond laser surface processing

We demonstrate the ability to create functionalized microfluidic channels using femtosecond laser surface processing (FLSP). FLSP is an emerging advanced manufacturing technology used to modify the surface properties of materials directly and permanently by producing self-organized quasi-periodic micro- and nano-scale surface features along with surface and subsurface chemical and grain structure changes. We demonstrate on Hastelloy X that by controlling the laser fluence and pulse count, the depth of the microchannels and height of the FLSP microstructures within the microchannels can be controlled independently.

Ultrashort pulse laser applications, micro- and na↗

Layer‐by‐Layer Engineered All‐Liquid Microfluidic Chips for Enzyme Immobilization

Abstract Enzyme immobilization in the confines of microfluidic chips, that promote enzyme activity and stability, has become a powerful strategy to enhance biocatalysis and biomass conversion. Here, based on a newly developed all‐liquid microfluidic chip, fabricated by the interfacial assembly of nanoparticle surfactants (NPSs) in a biphasic system, a layer‐by‐layer assembly strategy to generate polysaccharide multilayers on the surface of a microchannel, greatly enhancing the mechanical properties of the microchannel and offering a biocompatible microenvironment for enzyme immobilization, is presented. Using horseradish peroxidase and glucose oxidase as model enzymes, all‐liquid microfluidic enzymatic and cascade reactors have been constructed and the crucial role of polysaccharide multilayers on enhancing the enzyme loading and catalytic efficiency is demonstrated.

Liu, Tan↗

On-Chip Spyhole Nanoelectrospray Ionization Mass Spectrometry for Sensitive Biomarker Detection in Small Volumes

A polyimide microfluidic chip with a microhole emitter (Ø 10–12 μm) created on top of a microchannel by scanning laser ablation has been designed for nanoelectrospray ionization (spyhole-nanoESI) to couple microfluidics with mass spectrometry. The spyhole-nanoESI showed higher sensitivity compared to standard ESI and microESI from the end of the microchannel. The limits of detection (LOD) for peptide with the spyhole-nanoESI MS reached 50 pM, which was 600 times lower than that with standard ESI. The present microchip emitter allows the analysis of small volumes of samples. As an example, a small cell lung cancer biomarker, neuron-specific enolase (NSE), was detected by monitoring the transition of its unique peptide with the spyhole-nanoESI MS/MS. NSE at 0.2 nM could be well identified with a signal to noise ratio (S/N) of 50, and thereby its LOD was estimated to be 12 pM. The potential application of the spyhole-nanoESI MS/MS in cancer diagnosis was further demonstrated with the successful detection of 2 nM NSE from 1 μL of human serum. Before the detection, the serum sample spiked with NSE was first depleted with immune spin column, then desalted by centrifugal filter device, and finally digested by trypsin, without any other complicated preparation steps. The concentration matched the real condition of clinical samples. In addition, the microchips can be disposable to avoid any cross contamination. The present technique provides a highly efficient way to couple microfluidics with MS, which brings additional values to various microfluidics and MS-based analysis. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-objective design of microvascular panels for battery cooling applications

Building on a recently developed optimization method based on an interface-enriched generalized finite element method, multiple objective functions are considered for the optimization of 2D networks of microchannels embedded in battery-cooling panels. The objective functions considered in this study are a differentiable alternative to the maximum temperature (the p-mean of the temperature), the pressure drop and the variance of the temperature. The -constraint method and the normalized normal constraint method are used to generate the pressure-temperature Pareto optimal front of the multi-objective optimization problem. The effects of different operating constraints/conditions such as localization of heat sources, prescribed pump power and imposed flow rate on the optimal designs are investigated. In addition to the topology of the embedded network, the cross sections of the microchannels are also introduced as design parameters to further improve the pressure drop of the designs. The resulting variable-cross-section optimized design is validated with experiment.

energy storage (including batteries and capacitors↗

Physics of lithium bromide (LiBr) solution dewatering through vapor venting membranes

The physics of water desorption from a lithium bromide (LiBr) solution flow through an array of microchannels capped by a porous membrane is studied. The membrane allows the vapor to exit the flow and retains the liquid. Effects of different parameters such as wall temperature, solution and vapor pressures, and solution mass flux on the desorption rate were studied. Two different mechanisms of desorption are analyzed. These mechanisms consisted of: (1) direct diffusion of water molecules out of the solution and their subsequent flow through the membrane and (2) formation of water vapor bubbles within the solution and their venting through the membrane. Direct diffusion was the dominant desorption mode at low surface temperatures and its magnitude was directly related to the vapor pressure, the solution concentration, and the heated wall temperature. Desorption at the boiling regime was predominantly controlled by the solution flow pressure and mass flux. Microscale visualization studies suggested that at a critical mass flux, some bubbles are carried out of the desorber through the solution microchannels rather than being vented through the membrane. Overall, an order of magnitude higher desorption rate compare to a previous study on a membrane-based desorber was achieved. Published by Elsevier Ltd.

Isfahani, RN↗

Timing resolution and rate capability of Photonis miniPlanacon XPM85212/A1-S MCP-PMT

In this paper we report on a set of experiments that focus on measuring the timing performance of the Photonis miniPlanacon XPM85212/A1-S microchannel plate photomultiplier tubes along with the detector response at high event rates. The detector has a single photoelectron timing resolution of 30 ps at low rates ( 10 kHz ). We show that both the gain and the timing start to deteriorate around 1 MHz with 20 photoelectrons per channel at 1 0 4 target gain, giving the current per unit of area limits of 1.38 μ A / cm 2 and 2.38 μ A / cm 2 for the two tested devices. Photo-multiplier tubes with lower micro-channel plate resistivity exhibit a better rate capability due to the faster replenishment of the charge inside the microchannels. As we demonstrate, another method to improve the rate capability is to operate the photon detector tubes at a lower gain by reducing the supply voltage and compensating for the loss of amplitude by an additional amplification stage at the expense of the achieved timing resolution. The tube active area over which the beam is spread also plays a role since the same amount of light yields a better rate capability when spread over a larger area. The tubes exposed to high event rates showed an uncharacteristically slow recovery back to its initial gain with 80 % of the initial gain recovered only after several tens of minutes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Laser-assisted embedding of all-glass optical fiber sensors into bulk ceramics for high-temperature applications

We develop a laser-assisted sensor embedding process to embed all-glass optical fiber sensors into bulk ceramics for high-temperature applications. A specially designed two-step microchannel was fabricated on an Al 2 O 3 substrate for sensor embedment using a picosecond (ps) laser. An optical fiber Intrinsic Fabry-Perot Interferometer (IFPI) sensor was embedded at the bottom of the microchannel and covered by Al 2 O 3 slurry which was subsequently sintered by a CO 2 laser. The sensor spectrum was in-situ monitored during the laser sintering process to ensure the survival of the sensor and optimize the laser sintering parameters. By testing in furnace through high temperature, the embedded optical fiber shows improved stability after CO 2 laser sealing, resulting in the linear temperature response of the embedded optical fiber IFPI sensor. To improve the embedded IFPI sensor for thermal strain measurement, a dummy fiber was co-embedded with the sensing fiber to improve the mechanical bonding between the sensing fiber and the ceramic substrate so that the thermal strain of the ceramic substrate can apply on the sensing fiber. The response sensitivity, measurement repeatability and high-temperature long-term stability of the embedded optical fiber IFPI sensor were evaluated in this work.

47 OTHER INSTRUMENTATION↗

Poly(dimethylsiloxane) microchip-based immunoassay with multiple reaction zones: Toward on-chip multiplex detection platform

In this work, a poly(dimethylsiloxane) (PDMS) microchip-based immuno-sensing platform with integrated pneumatic micro valves is described. The microchip was fabricated with multiple layer soft lithography technology. By controlling the activation status of corresponding valves, reagent flows in the microchannel network can be well manipulated so that immuno-reactions only take place at designated reaction zones (DRZs). Four DRZs are included in the prototype microchip. Since these DRZs are all isolated from each other by micro valves, cross contamination is prevented. Using the inner surface of the all-PDMS microchannel as immunoassay substrate, on-chip sandwich format solid phase immunoassay was performed to demonstrate the feasibility of this immuno-sensing platform. Mouse IgG and fluorescein isothiocyanate (FITC) were used as the model analyte and the signal reporter respectively. Only 10 ul sample is needed for the assay and low detection limit of 5 ng/ml (≈33 pM) was achieved though low-cost polyclonal antibodies were used in our experiment for feasibility study only. The encouraging results from mouse IgG immunoassay proved the feasibility of our microchip design. With slight modification of the assay protocol, the same chip design can be used for multi-target detection and can provide a simple, cost-effective and integrated microchip solution for multiplex immunoassay applications.

60 APPLIED LIFE SCIENCES↗

Resolution and Mass Range Performance in Distance-of-flight Mass Spectrometry with a Multichannel Focal-Plane Camera Detector.

Distance-of-flight mass spectrometry (DOFMS) is a velocity-based mass-separation technique in which ions are separated in space along the plane of a spatially selective detector. In the present work, a solid-state charge-detection array, the focal-plane camera (FPC), was incorporated into the DOFMS platform. Use of the FPC with our DOFMS instrument resulted in improvements in analytical performance, usability, and versatility over a previous generation instrument that employed a microchannel-plate/phosphor DOF detector. Notably, FPC detection provided resolution improvements of at least a factor of 2, with typical DOF linewidths of 300 μm (R((fwhm)) = 1000). The merits of solid-state detection for DOFMS are evaluated, and methods to extend the DOFMS mass range are considered.

Array Detection↗

Experimental Insights into the Coupling of Methane Combustion and Steam Reforming in a Catalytic Plate Reactor in Transient Mode

The microstructured reactor concept is very promising technology to develop a compact reformer for distributed hydrogen generation. In this work, a catalytic plate reactor (CPR) is developed and investigated for the coupling of methane combustion (MC) and methane steam reforming (MSR) over Pt/Al 2 O 3 -coated microchannels in cocurrent and counter-current modes in transient experiments during start-up. A three-dimensional (3D) computational fluid dynamics (CFD) simulation shows uniform velocity and pressure distribution profiles in microchannels. For a channel velocity from 5.1 to 57.3 m/s in the combustor, the oxidation of methane is complete and self-sustainable without explosion, blow-off, or extinction; nevertheless, flashbacks are observed in counter-current mode. In the reformer, the maximum methane conversion is 84.9% in cocurrent mode, slightly higher than that of 80.2% in counter-current mode at a residence time of 33 ms, but at the cost of three times higher energy input in the combustor operating at ~1000 °C. Nitric oxide (NO) is not identified in combustion products, but nitrous oxide (N 2 O) is a function of coupling mode and forms significantly in cocurrent mode. Furthermore, this research would be helpful to establish the start-up strategy and environmental impact of compact reformers on a small scale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗