SEARCH · Search NASA
Results for “Microfluidic”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Crystallization Optimization of Pharmaceutical Solid Forms with X-ray Compatible Microfluidic Platforms
Abstract not provided
Pore-scale simulation of mixing-induced calcium carbonate precipitation and dissolution in a microfluidic pore network: PORE-SCALE SIMULATION IN A MICROMODEL
Explore the source record for details and available documents.
Clinical microfluidics for neutrophil genomics and proteomics
Explore the source record for details and available documents.
Multiplexed in-gel microfluidic immunoassays: characterizing protein target loss during reprobing of benzophenone-modified hydrogels
From whole tissues to single-cell lysate, heterogeneous immunoassays are widely utilized for analysis of protein targets in complex biospecimens. Recently, benzophenone-functionalized hydrogel scaffolds have been used to immobilize target protein for immunoassay detection with fluorescent antibody probes. In benzophenone-functionalized hydrogels, multiplex target detection occurs via serial rounds of chemical stripping (incubation with sodium-dodecyl-sulfate (SDS) and β-mercaptoethanol at 50-60 °C for ≥1 h), followed by reprobing (interrogation with additional antibody probes). Although benzophenone facilitates covalent immobilization of proteins to the hydrogel, we observe 50% immunoassay signal loss of immobilized protein targets during stripping rounds. Here, we identify and characterize signal loss mechanisms during stripping and reprobing. We posit that loss of immobilized target is responsible for ≥50% of immunoassay signal loss, and that target loss is attributable to disruption of protein immobilization by denaturing detergents (SDS) and incubation at elevated temperatures. Furthermore, our study suggests that protein losses under non-denaturing conditions are more sensitive to protein structure (i.e., hydrodynamic radius), than to molecular mass (size). We formulate design guidance for multiplexed in-gel immunoassays, including that low-abundance proteins be immunoprobed first, even when targets are covalently immobilized to the gel. We also recommend careful scrutiny of the order of proteins targets detected via multiple immunoprobing cycles, based on the protein immobilization buffer composition.
3D particle transport in multichannel microfluidic networks with rough surfaces
Not Available
Mineralogy of microbially induced calcium carbonate precipitates formed using single cell drop-based microfluidics
Microbe-mineral interactions are ubiquitous and can facilitate major biogeochemical reactions that drive dynamic Earth processes such as rock formation. One example is microbially induced calcium carbonate precipitation (MICP) in which microbial activity leads to the formation of calcium carbonate precipitates. A majority of MICP studies have been conducted at the mesoscale but fundamental questions persist regarding the mechanisms of cell encapsulation and mineral polymorphism. Here, we are the first to investigate and characterize precipitates on the microscale formed by MICP starting from single ureolytic E. coli MJK2 cells in 25 µm diameter drops. Mineral precipitation was observed over time and cells surrounded by calcium carbonate precipitates were observed under hydrated conditions. Using Raman microspectroscopy, amorphous calcium carbonate (ACC) was observed first in the drops, followed by vaterite formation. ACC and vaterite remained stable for up to 4 days, possibly due to the presence of organics. The vaterite precipitates exhibited a dense interior structure with a grainy exterior when examined using electron microscopy. Autofluorescence of these precipitates was observed possibly indicating the development of a calcite phase. The developed approach provides an avenue for future investigations surrounding fundamental processes such as precipitate nucleation on bacteria, microbe-mineral interactions, and polymorph transitions.
An X-ray transparent microfluidic platform for screening of the phase behavior of lipidic mesophases
Abstract not provided
Droplet-based microfluidic platform for heterogeneous enzymatic assays
Explore the source record for details and available documents.
A microfluidic approach for protein structure determination at room temperature via on-chip anomalous diffraction
Abstract not provided
Long-term non-invasive interrogation of human dorsal root ganglion neuronal cultures on an integrated microfluidic multielectrode array platform
Scientific studies in drug development and toxicology rely heavily on animal models, which often inaccurately predict the true response for human exposure. This may lead to unanticipated adverse effects or misidentified risks that result in, for example, drug candidate elimination. The utilization of human cells and tissues for in vitro physiological platforms has become a growing area of interest to bridge this gap and to more accurately predict human responses to drugs and toxins. The effects of new drugs and toxins on the peripheral nervous system are often investigated with neurons isolated from dorsal root ganglia (DRG), typically with one-time measurement techniques such as patch clamping. Here, we report the use of our multi-electrode array (MEA) platform for long-term noninvasive assessment of human DRG cell health and function. In this study, we acquired simultaneous optical and electrophysiological measurements from primary human DRG neurons upon chemical stimulation repeatedly through day in vitro (DIV) 23. Distinct chemical signatures were noted for the cellular responses evoked by each chemical stimulus. Additionally, the cell viability and function of the human DRG neurons were consistent through DIV 23. To the best of our knowledge, this is the first report on long-term measurements of the cell health and function of human DRG neurons on a MEA platform. Future generations will include higher electrode numbers in customized arrangements as well as integration with different tissue types on a single device. This platform will provide a valuable testing tool for both rodent and human cells, enabling a more comprehensive risk assessment for drug candidates and toxicants.
Solvent compatible microfluidic platforms for pharmaceutical solid form screening
Abstract not provided
Experiments and computations of microfluidic liquid–liquid flow patterns
We study two-phase liquid–liquid flow patterns in a 500 μm capillary microchannel for four biphasic systems: ethyl acetate/water, 2-pentanol/water, methyl isobutyl ketone/water, and heptane/water. Flow visualization experiments using laser induced fluorescence (LIF) reveal a total of 7 different flow patterns for all solvent pairs, namely slug flow, droplet flow, slug-droplet flow, parallel, annular, dispersed, and irregular flow. A map of different flow patterns was built to delineate the origin of their formation. We find conventional dimensionless groups are insufficient to uniquely identify the flow patterns. Computational fluid dynamics (CFD) modeling in OpenFOAM shows agreement with the experimental flow patterns for most of the two-phase flows. Principal component analysis reduces the dimensionality of potential descriptors of flow patterns and, unlike prior work using two dimensionless numbers, determines six important features that describe >95% of the variance of the experimental flow patterns. These include the total flow rate, the flow rate ratio between the two phases, the capillary and Ohnesorge numbers of the aqueous phase, and the Weber number and velocity of the organic phase. Lastly, we build a decision-tree model to further regress the data and identify the critical features and demonstrate an accuracy in predicting the flow patterns of up to 93%.
Microfluidic-supported emulsion polymerization: molecular weight and concentration of surface-capping agents impact the formation of anisotropic polyvinylmethacrylate particles
Surface-capping agents—for example, amphiphilic surfactant molecules, water-soluble polymers, or polyelectrolytes—play a critical role during polymerization reactions for both the formation and stability of colloidal polymer particles.
Reaction-diffusion analysis for one-step plasma etching and bonding of microfluidic devices
A self-similar reaction front develops in reactive ion etching when the ions penetrate channels of shallow height h. This relates to the patterning of microchannels using a single-step etching and bonding, as described by Rhee et al. [Lab Chip 5, 102 (2005)]. Experimentally, we report that the front location scales as x{sub f{approx}}ht{sup 1/2} and the width is time-invariant and scales as {delta}{approx}h. Mean-field reaction-diffusion theory and Knudsen diffusion give a semiquantitative understanding of these observations and allow optimization of etching times in relation to bonding requirements.