Search NASA⌕ Search

SEARCH · Search NASA

Results for “NET ENERGY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

The physics of gain relevant to inertial fusion energy target designs

In inertial confinement fusion, pellets of deuterium tritium fuel are compressed and heated to the conditions where they undergo fusion and release energy. The target gain (ratio of energy released from the fusion reactions to the energy in the drive source) is a key parameter in determining the power flow and economics of an inertial fusion energy (IFE) power plant. In this study, the physics of gain is explored for laser-direct-drive targets with driver energy at the megajoule scale. This analysis is performed with the assumption of next-generation laser technologies that are expected to increase convergent drive pressures to over 200 Mbar. This is possible with the addition of bandwidth to the laser spectrum and by employing focal-spot zooming. Simple physics arguments are used to derive scaling laws that describe target gain as a function of laser energy, adiabat, ablation pressure, and implosion velocity. Scaling laws are found for the unablated mass, ablation pressure, areal density, implosion velocity, and in-flight aspect ratio. Furthermore, those scaling laws are then used to explore the design space for IFE targets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

How turbulent transport broadens the heat flux width: local SOL production or edge turbulence spreading?

This paper uses data from limited HL-2A Ohmic-plasma to answer the question of how turbulent transport broadens the heat flux width. A key issue in this study is the determination of the origin of scrape-off layer (SOL) turbulence. We develop the concept of the energy production ratio ${R_a}$, which compares the flux of turbulence energy across the last closed flux surface (LCFS) to the net, integrated energy production in the SOL. The flux of turbulence energy (i.e. spreading) is measured directly, using Langmuir probes. Experimental data is used to evaluate ${R_a}$. Results show that usually ${R_a} > 1$, indicating that SOL turbulence is energized primarily by edge turbulence spreading. The exceptions—cases where ${R_a} < 1$—are those with relatively stronger ${\mathbf{E}} \times {\mathbf{B}}$ shear near the LCFS. The latter inhibits both turbulence spreading and local SOL production, but has greater effects on spreading. High blob fraction in the turbulence correlates with large values of ${R_a}$. The implications for heat flux width physics are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-Performance Ducts in Hot-Dry Climates

Duct thermal losses and air leakage have long been recognized as prime culprits in the degradation of heating, ventilating, and air-conditioning (HVAC) system efficiency. Both the U.S. Department of Energy’s Zero Energy Ready Home program and California’s proposed 2016 Title 24 Residential Energy Efficiency Standards require that ducts be installed within conditioned space or that other measures be taken to provide similar improvements in delivery effectiveness (DE). Pacific Gas & Electric Company commissioned a study to evaluate ducts in conditioned space and high-performance attics (HPAs) in support of the proposed codes and standards enhancements included in California’s 2016 Title 24 Residential Energy Efficiency Standards. The goal was to work with a select group of builders to design and install high-performance duct (HPD) systems, such as ducts in conditioned space (DCS), in one or more of their homes and to obtain test data to verify the improvement in DE compared to standard practice. Davis Energy Group (DEG) helped select the builders and led a team that provided information about HPD strategies to them. DEG also observed the construction process, completed testing, and collected cost data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Wind Energy Costs in Puerto Rico Through 2035

In 2019, Puerto Rico codified into law a 100% renewable electricity by 2050 target. Decision makers there need information about the costs and performance of wind energy technologies to incorporate into planning efforts for the future grid. After consulting with key technical stakeholders and accounting for unique conditions in Puerto Rico like increased hurricane risks, we customize NREL's Renewable Energy Potential model to calculate how capital expenditures, operational expenditures, net annual energy generation, and levelized cost of energy (LCOE) vary in time and space for wind energy projects around Puerto Rico. Wind turbines can add value by providing grid services through grid-forming inverters and complement solar energy generation with evening and nighttime electricity production, especially offshore. By 2035, we expect average costs of land-based and offshore wind energy in Puerto Rico to reach $\$$69/MWh (6.9 cents/kWh) and $\$$100/MWh (10 cents/kWh), respectively. While these projections do not include transmission system upgrade costs, they do suggest that low-cost, clean electricity is possible for Puerto Rico.

17 WIND ENERGY↗

Technology Solutions Case Study: High-Performance Walls in Hot-Dry Climates

In this project,the Alliance for Residential Building Innovation (ARBI) team worked with builders in California to implement wall assemblies meeting a U-value lower than 0.050 Btu/h-ft2-°F. ARBI and its project team members helped builders identify preferred wall designs that met the requirements of their architects, structural engineers, and purchasing agents and that were acceptable to their subcontractors. Construction methods were observed and documented and construction costs obtained from builders were used to inform cost estimates for a range of advanced wall system types and insulation types. Wall framing types of 2 × 6 (16- and 24-in. on center [o.c.]) and double stud were modeled in Building Energy Optimization (BEopt™) software with cavity insulation levels ranging from R-19 to R-33 (double stud) and exterior rigid insulation of R-4, R-6, and R-8.

ARBI↗

The Anderson/Sargent Dallas Show House

This case study describes development of a net zero energy home featuring high efficiency air and duct sealing, solar thermal and photovoltaic systems, and water conservation.

Building Science Corporation↗

Closing in on critical net-baryon fluctuations at LHC energies: Cumulants up to third order in Pb–Pb collisions

Fluctuation measurements are important sources of information on the mechanism of particle production at LHC energies. This article reports the first experimental results on third-order cumulants of the net-proton distributions in Pb–Pb collisions at a center-of-mass energy $\sqrt{s_{NN}}$ = 5.02 TeV recorded by the ALICE detector. The results on the second-order cumulants of net-proton distributions at $\sqrt{s_{NN}}$ = 2.76 and 5.02 TeV are also discussed in view of effects due to the global and local baryon number conservation. The results demonstrate the presence of long-range rapidity correlations between protons and antiprotons. Such correlations originate from the early phase of the collision. The experimental results are compared with HIJING and EPOS model calculations, and the dependence of the fluctuation measurements on the phase-space coverage is examined in the context of lattice quantum chromodynamics (LQCD) and hadron resonance gas (HRG) model estimations. The measured third-order cumulants are consistent with zero within experimental uncertainties of about 4% and are described well by LQCD and HRG predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TU-H-207A-09: An Automated Technique for Estimating Patient-Specific Regional Imparted Energy and Dose From TCM CT Exams Across 13 Protocols

Purpose: To develop an automated technique for estimating patient-specific regional imparted energy and dose from tube current modulated (TCM) computed tomography (CT) exams across a diverse set of head and body protocols. Methods: A library of 58 adult computational anthropomorphic extended cardiac-torso (XCAT) phantoms were used to model a patient population. A validated Monte Carlo program was used to simulate TCM CT exams on the entire library of phantoms for three head and 10 body protocols. The net imparted energy to the phantoms, normalized by dose length product (DLP), and the net tissue mass in each of the scan regions were computed. A knowledgebase containing relationships between normalized imparted energy and scanned mass was established. An automated computer algorithm was written to estimate the scanned mass from actual clinical CT exams. The scanned mass estimate, DLP of the exam, and knowledgebase were used to estimate the imparted energy to the patient. The algorithm was tested on 20 chest and 20 abdominopelvic TCM CT exams. Results: The normalized imparted energy increased with increasing kV for all protocols. However, the normalized imparted energy was relatively unaffected by the strength of the TCM. The average imparted energy was 681 ± 376 mJ for abdominopelvic exams and 274 ± 141 mJ for chest exams. Overall, the method was successful in providing patientspecific estimates of imparted energy for 98% of the cases tested. Conclusion: Imparted energy normalized by DLP increased with increasing tube potential. However, the strength of the TCM did not have a significant effect on the net amount of energy deposited to tissue. The automated program can be implemented into the clinical workflow to provide estimates of regional imparted energy and dose across a diverse set of clinical protocols.

60 APPLIED LIFE SCIENCES↗

SPBMI Microgrid

The SPBMI Microgrid Project aims to achieve four primary objectives that support. the tribe’s strategic goals, plans, and mission: 1) Ensure the availability of resilient energy for five essential tribal facilities as identified in the San Pasqual Hazard Mitigation Plan and described in the San Pasqual Energy & Resiliency Plan; 2) Provide solar generation sufficient to achieve net-zero energy consumption at the five essential facilities; 3) Reduce the tribe’s lifetime levelized costs of energy (LCOE); and 4) Support tribal energy objectives including reducing greenhouse gas emissions. Secondary objectives include supporting local workforce development and employment, in part by utilizing commercially available and warranted technologies that can be operated and maintained by tribal staff. Expected outcomes from the project include substantially eliminating long-duration disruptions to essential tribal services due to utility outages (which totaled 34 hours in 2017); reducing lifetime energy costs by approximately $1.75 million; and producing approximately 6.5 GWh of renewable electricity over the system’s lifetime.

14 SOLAR ENERGY↗

Analysis of Minimum Efficiency Performance Standards for Residential General Service Lighting in Chile

Minimum Efficiency Performance Standards (MEPS) have been chosen as part of Chile's national energy efficiency action plan. As a first MEPS, the Ministry of Energy has decided to focus on a regulation for lighting that would ban the sale of inefficient bulbs, effectively phasing out the use of incandescent lamps. Following major economies such as the US (EISA, 2007) , the EU (Ecodesign, 2009) and Australia (AS/NZS, 2008) who planned a phase out based on minimum efficacy requirements, the Ministry of Energy has undertaken the impact analysis of a MEPS on the residential lighting sector. Fundacion Chile (FC) and Lawrence Berkeley National Laboratory (LBNL) collaborated with the Ministry of Energy and the National Energy Efficiency Program (Programa Pais de Eficiencia Energetica, or PPEE) in order to produce a techno-economic analysis of this future policy measure. LBNL has developed for CLASP (CLASP, 2007) a spreadsheet tool called the Policy Analysis Modeling System (PAMS) that allows for evaluation of costs and benefits at the consumer level but also a wide range of impacts at the national level, such as energy savings, net present value of savings, greenhouse gas (CO2) emission reductions and avoided capacity generation due to a specific policy. Because historically Chile has followed European schemes in energy efficiency programs (test procedures, labelling program definitions), we take the Ecodesign commission regulation No 244/2009 as a starting point when defining our phase out program, which means a tiered phase out based on minimum efficacy per lumen category. The following data were collected in order to perform the techno-economic analysis: (1) Retail prices, efficiency and wattage category in the current market, (2) Usage data (hours of lamp use per day), and (3) Stock data, penetration of efficient lamps in the market. Using these data, PAMS calculates the costs and benefits of efficiency standards from two distinct but related perspectives: (1) The Life-Cycle Cost (LCC) calculation examines costs and benefits from the perspective of the individual household; and (2) The National Perspective projects the total national costs and benefits including both financial benefits, and energy savings and environmental benefits. The national perspective calculations are called the National Energy Savings (NES) and the Net Present Value (NPV) calculations. PAMS also calculate total emission mitigation and avoided generation capacity. This paper describes the data and methodology used in PAMS and presents the results of the proposed phase out of incandescent bulbs in Chile.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Editorial for Special Issue: Grid-Interactive Efficient Buildings—Part 2

This issue of the ASME Journal of Engineering for Sustainable Buildings and Cities (JESBC) is fully dedicated to peer-reviewed papers specific to technologies and applications of Grid-interactive Efficient Buildings (GEBs). As defined by a series of publications by the U.S. Department of Energy (DOE) and outlined in Part 1 of the editorial of JESBC August 2020 issue, GEBs are efficient, connected, smart, and flexible buildings. This GEB special issue covers some technologies and applications for grid-connected buildings and communities. Some of technologies included in the special issue are dynamic insulation systems for building envelopes, building integrated fuel cells, and rooftop PV systems. Furthermore, the issue outlines the designs and cost-benefits of net-zero energy (NZE) buildings and carbon neutral communities in the United States.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comfort, Indoor Air Quality, and Energy Consumption in Low Energy Homes

This report documents the results of an in-depth evaluation of energy consumption and thermal comfort for two potential net zero-energy homes (NZEHs) in Massachusetts, as well as an indoor air quality (IAQ) evaluation performed in conjunction with Lawrence Berkeley National Laboratory (LBNL).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comfort, Indoor Air Quality, and Energy Consumption in Low Energy Homes

This report documents the results of an in-depth evaluation of energy consumption and thermal comfort for two potential net zero-energy homes (NZEHs) in Massachusetts, as well as an indoor air quality (IAQ) evaluation performed in conjunction with Lawrence Berkeley National Laboratory (LBNL).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of energy efficiency between variable refrigerant flow systems and ground source heat pump systems

With the current movement toward net zero energy buildings, many technologies are promoted with emphasis on their superior energy efficiency. The variable refrigerant flow (VRF) and ground source heat pump (GSHP) systems are probably the most competitive technologies among these. However, there are few studies reporting the energy efficiency of VRF systems compared with GSHP systems. In this article, a preliminary comparison of energy efficiency between the air-source VRF and GSHP systems is presented. The computer simulation results show that GSHP system is more energy efficient than the air-source VRF system for conditioning a small office building in two selected US climates. In general, GSHP system is more energy efficient than the air-source VRV system, especially when the building has significant heating loads. For buildings with less heating loads, the GSHP system could still perform better than the air-source VRF system in terms of energy efficiency, but the resulting energy savings may be marginal.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗