Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron activation system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

High-temperature 205 Tl decay clarifies 205 Pb dating in early Solar System

Radioactive nuclei with lifetimes on the order of millions of years can reveal the formation history of the Sun and active nucleosynthesis occurring at the time and place of its birth. Among such nuclei whose decay signatures are found in the oldest meteorites, 205 Pb is a powerful example, as it is produced exclusively by slow neutron captures (the s process), with most being synthesized in asymptotic giant branch (AGB) stars. However, making accurate abundance predictions for 205 Pb has so far been impossible because the weak decay rates of 205 Pb and 205 Tl are very uncertain at stellar temperatures. To constrain these decay rates, we measured for the first time the bound-state β - decay of fully ionized 205 Tl 81+ , an exotic decay mode that only occurs in highly charged ions. The measured half-life is 4.7 times longer than the previous theoretical estimate and our 10% experimental uncertainty has eliminated the main nuclear-physics limitation. With new, experimentally backed decay rates, we used AGB stellar models to calculate 205 Pb yields. Propagating those yields with basic galactic chemical evolution (GCE) and comparing with the 205 Pb/ 204 Pb ratio from meteorites, we determined the isolation time of solar material inside its parent molecular cloud. We find positive isolation times that are consistent with the other s-process short-lived radioactive nuclei found in the early Solar System. Our results reaffirm the site of the Sun’s birth as a long-lived, giant molecular cloud and support the use of the 205 Pb– 205 Tl decay system as a chronometer in the early Solar System.

79 ASTRONOMY AND ASTROPHYSICS↗

X-RAY AND OPTICAL OBSERVATIONS OF A 0535+26

We present recent contemporaneous X-ray and optical observations of the Be/X-ray binary system A 0535+26 with the Fermi/Gamma-ray Burst Monitor (GBM) and several ground-based observatories. These new observations are put into the context of the rich historical data (since {approx}1978) and discussed in terms of the neutron-star-Be-disk interaction. The Be circumstellar disk was exceptionally large just before the 2009 December giant outburst, which may explain the origin of the unusual recent X-ray activity of this source. We found a peculiar evolution of the pulse profile during this giant outburst, with the two main components evolving in opposite ways with energy. A hard 30-70 mHz X-ray quasi-periodic oscillation was detected with GBM during this 2009 December giant outburst. It becomes stronger with increasing energy and disappears at energies below 25 keV. In the long term a strong optical/X-ray correlation was found for this system, however in the medium term the H{alpha} equivalent width and the V-band brightness showed an anti-correlation after {approx}2002 August. Each giant X-ray outburst occurred during a decline phase of the optical brightness, while the H{alpha} showed a strong emission. In late 2010 and before the 2011 February outburst, rapid V/R variations are observed in the strength of the two peaks of the H{alpha} line. These had a period of {approx}25 days and we suggest the presence of a global one-armed oscillation to explain this scenario. A general pattern might be inferred, where the disk becomes weaker and shows V/R variability beginning {approx}6 months following a giant outburst.

79 ASTRONOMY AND ASTROPHYSICS↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Ultra-rapid, physics-based development pathway for reactor-relevant RF antenna materials

This paper presents a rapid, atomistically-informed, experimental development pathway for fusion reactor-relevant radio frequency (RF) antenna materials in the Cu-Cr-(Nb,Al,Zr) composition system, with the goal of improving upon GRCop-84. RF antennas in a tokamak fusion reactor will face a unique set of challenges as both structural and functional materials. The desired material must simultaneously achieve and maintain high electrical conductivity, high strength, high thermal conductivity, resist high temperatures, possess low nuclear activation, and incur low damage due to neutron bombardment. The GRCop-84 alloy serves as a starting point for iterative improvement, with the desire to reduce or eliminate Nb from the material to minimize nuclear activation. The rapid development pathway makes use of a multi-target combinatorial thick film sputtering process to produce full ternary phase diagrams on a Si wafer substrate. Transient grating spectroscopy (TGS), a laser-ultrasonic method, will determine spatially-varying thermo-elastic properties, while four terminal electrical conductivity measurements will map out the best per- forming regions of the sample for in-depth study at larger length scales. High energy proton and self-ion irradiation emulates the effects of neutron damage on the thermal/electric properties. With rapid turnaround time (∼days) in terms of mapping radiation damage-induced material property changes in the full ternary system, these techniques allow rapid iteration towards an optimal material, testing hundreds of nearby compositions in the time it took to test one. Focused testing of larger, single composition samples (produced in an arc furnace or by laser sintering) provides data on structural and high power RF properties, and validates our thick-film based workflow.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Processing Neutron Cross Section Covariances using NJOY-99 and PUFF-IV

With the growing demand for multigroup covariances, the National Nuclear Data Center (NNDC) has been experiencing an upsurge in its covariance data processing activities using the two US codes NJOY-99 (LANL) and PUFF-IV (ORNL). The code NJOY-99 was upgraded by incorporating the new module ERRORJ-2.3, while the NNDC served as the active user and provided feedback. The NNDC has been primarily processing neutron cross section covariances on its 64-bit Linux cluster in support of two DOE programs, the Global Nuclear Energy Partnership (GNEP) and the Nuclear Criticality Safety Program (NCSP). For GNEP, the NNDC used NJOY-99.259 to generate multigroup covariance matrices of {sup 56}Fe, {sup 23}Na, {sup 239}Pu, {sup 235}U and {sup 238}U from the JENDL-3.3 library using the 15-, 33-, and 230-energy group structures. These covariance matrices will be used to test a new collapsing algorithm which will subsequently be employed to calculate uncertainties on integral parameters in different fast neutron-based systems. For NCSP, we used PUFF-IV 1.0.4 to verify the processability of new evaluated covariance data of {sup 55}Mn, {sup 239}Pu, {sup 233}U, {sup 235}U and {sup 238}U generated by a collaboration of ORNL and LANL. For the data end-users at large, the NNDC has made available a Web site which provides a static visualization interface for all materials with covariance data in the four major data libraries: ENDF/B-VI.8 (47 materials), ENDF/B-VII.0 (26 materials), JEFF-3.1 (37 materials) and JENDL-3.3 (20 materials)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Pervasive symmetry-lowering nanoscale structural fluctuations in the cuprate La 2−𝑥 ⁢Sr 𝑥 ⁢Cu⁢O 4

The cuprate superconductors are among the most widely studied quantum materials, yet there remain fundamental open questions regarding their electronic properties and the role of structural degrees of freedom. Recent neutron and x-ray scattering measurements uncovered exponential scaling with temperature of the strength of orthorhombic fluctuations in the tetragonal phase of La 2−𝑥⁢ Sr 𝑥 ⁢Cu⁢O 4 and Tl 2 ⁢Ba 2 ⁢Cu⁢O 6+𝛿 , unusual behavior that closely resembles prior results for the emergence of superconducting fluctuations, and that points to a common origin rooted in inherent correlated structural inhomogeneity. Here, in this study, we use neutron and x-ray diffuse scattering to provide further insight into structural fluctuations in La 2−𝑥 ⁢Sr 𝑥 ⁢Cu⁢O 4 . We perform measurements up to temperatures that approach the melting point of the undoped parent compound, and we investigate the effects of in situ in-plane uniaxial elastic stress and plastic deformation. Our neutron scattering results for the parent compound La 2 ⁢Cu⁢O 4 reveal that short-range orthorhombic fluctuations persist to the maximum experimental temperature of nearly 1000 K, i.e., to a significant fraction of the crystallization temperature. At this temperature, the spatial characteristic length extracted from the momentum-space data is still about three lattice constants. The neutron scattering experiment enables quasistatic discrimination and reveals that the response is increasingly dynamic at higher temperatures. We also find that neither compressive elastic stress along the tetragonal [110] direction nor irreversible plastic deformation activating the ⟨100⟩⁢[001] slip system significantly alter the robust orthorhombic fluctuations. Overall, these results support the notion that these fluctuations couple to subtle, underlying inhomogeneity that underpins the cuprate phase diagram. Finally, in La 1.8⁢ Sr 0.2⁢ Cu⁢O 4 , we uncover low-energy structural fluctuations at a nominally forbidden reflection that are distinct from the orthorhombic distortions. While the origin of these fluctuations is not clear, they might be related to the presence of extended defects such as dislocations or stacking faults.

Spieker, R. J. [Univ. of Minnesota, Minneapolis, M↗

Radio emission from binary stars

This paper reviews the radio emission from binary star systems - the emission processes that occur, the characteristics of the binary systems inferred from the radio observations, and the reasons for the activity. Several classes of binary stars are described including those with two main sequence stars, those with one normal star and a white dwarf, and those containing a neutron star or a black hole.

Dulk, G. A.↗

The measurement of trace elements in interplanetary dust and cometary particles by ultra-high sensitivity INAA

Today the major elemental composition of interplanetary dust particles (IDPs) is routinely determined in many laboratories. These and mineralogical studies have revealed the presence of at least two major types of IDPs, chondritic and refractory. Preliminary results of a successful attempt to determine abundances of a large suite of trace elements from both chondritic and refractory IDPs are reported. The analytical procedure can be used in the grain-by-grain analysis of returned cometary samples. Chondritic and refractory IDPs are characterized by standard scanning electron microscopy and energy dispersive x ray spectroscopy (SEM-EDX) techniques. With this system, detection limits for many elements are well below picogram levels, and some approach femtogram levels. This technique is non-destructive, although some sample handling is required, so particles can be analyzed by other techniques after instrument neutron activation analysis (INAA) is completed. Data is presently being reduced from the analyses of 7 IDPs. These are U2015E10, U2015F1, W7029-A2, W7029-A3, W7013A8, LACl (all chondritic) and 705 (refractory). So far, 17 different major and trace elements were detected and measured in these particles, including rare earths and some very volatile elements (Br and Zn).

Zolensky, M. E.↗

Results from the Coded Aperture Neutron Imaging System (CANIS).

Because of their penetrating power, energetic neutrons and gamma rays ({approx}1 MeV) offer the best possibility of detecting highly shielded or distant special nuclear material (SNM). Of these, fast neutrons offer the greatest advantage due to their very low and well understood natural background. We are investigating a new approach to fast-neutron imaging- a coded aperture neutron imaging system (CANIS). Coded aperture neutron imaging should offer a highly efficient solution for improved detection speed, range, and sensitivity. We have demonstrated fast neutron and gamma ray imaging with several different configurations of coded masks patterns and detectors including an 'active' mask that is composed of neutron detectors. Here we describe our prototype detector and present some initial results from laboratory tests and demonstrations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Results from the coded aperture neutron imaging system.

Because of their penetrating power, energetic neutrons and gamma rays ({approx}1 MeV) offer the best possibility of detecting highly shielded or distant special nuclear material (SNM). Of these, fast neutrons offer the greatest advantage due to their very low and well understood natural background. We are investigating a new approach to fast-neutron imaging - a coded aperture neutron imaging system (CANIS). Coded aperture neutron imaging should offer a highly efficient solution for improved detection speed, range, and sensitivity. We have demonstrated fast neutron and gamma ray imaging with several different configurations of coded masks patterns and detectors including an 'active' mask that is composed of neutron detectors. Here we describe our prototype detector and present some initial results from laboratory tests and demonstrations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Copper activation deuterium-tritium neutron yield measurements at the National Ignition Facility

A DT neutron yield diagnostic based on the reactions, {sup 63}Cu(n,2n){sup 62}Cu({beta}{sup +}) and {sup 65}Cu(n,2n) {sup 64} Cu({beta}{sup +}), has been fielded at the National Ignition Facility (NIF). The induced copper activity is measured using a NaI {gamma}-{gamma} coincidence system. Uncertainties in the 14-MeV DT yield measurements are on the order of 7% to 8%. In addition to measuring yield, the ratio of activities induced in two, well-separated copper samples are used to measure the relative anisotropy of the fuel {rho}R to uncertainties as low as 5%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision Measurements with Low Energy Neutrons (Final Report)

This project encompassed fives years of effort in three areas of precision measurements with low energy neutrons: a) hadronic weak interactions, b) decay correlations, and c) electric dipole moment. These experiments encompass the scientific program of the Fundamental Neutron Physics Beamline (FnPB) at the SNS, ORNL. This grant supported our responsibilities in each of the approved experiments at the FnPB (in order of schedule): NPDGamma (post run), n- 3 He (taking data), Nab (Jan 2016), and nEDM, in addition to the BL3 beamline lifetime experiment at NIST. We focused on three principal activities: a) development of techniques for the design a fabrication of low-field precision surface current electromagnetic coils, b) development of high-speed digital acquisition systems involving real-time digital pulse processing, and high-volume offline waveform processing, and c) experimental data analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

FISPACT-II: An Advanced Simulation System for Activation, Transmutation and Material Modelling

Fispact-II is a code system and library database for modelling activation-transmutation processes, depletion-burn-up, time dependent inventory and radiation damage source terms caused by nuclear reactions and decays. The Fispact-II code, written in object-style Fortran, follows the evolution of material irradiated by neutrons, alphas, gammas, protons, or deuterons, and provides a wide range of derived radiological output quantities to satisfy most needs for nuclear applications. It can be used with any ENDF-compliant group library data for nuclear reactions, particle-induced and spontaneous fission yields, and radioactive decay (including but not limited to TENDL-2015, ENDF/B-VII.1, JEFF-3.2, JENDL-4.0u, CENDL-3.1 processed into fine-group-structure files, GEFY-5.2 and UKDD-16), as well as resolved and unresolved resonance range probability tables for self-shielding corrections and updated radiological hazard indices. The code has many novel features including: extension of the energy range up to 1 GeV; additional neutron physics including self-shielding effects, temperature dependence, thin and thick target yields; pathway analysis; and sensitivity and uncertainty quantification and propagation using full covariance data. The latest ENDF libraries such as TENDL encompass thousands of target isotopes. Nuclear data libraries for Fispact-II are prepared from these using processing codes PREPRO, NJOY and CALENDF. These data include resonance parameters, cross sections with covariances, probability tables in the resonance ranges, PKA spectra, kerma, dpa, gas and radionuclide production and energy-dependent fission yields, supplemented with all 27 decay types. All such data for the five most important incident particles are provided in evaluated data tables. The Fispact-II simulation software is described in detail in this paper, together with the nuclear data libraries. The Fispact-II system also includes several utility programs for code-use optimisation, visualisation and production of secondary radiological quantities. Included in the paper are summaries of results from the suite of verification and validation reports available with the code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Influence of Pressure on Fast Picosecond Relaxation in Glass-Forming Materials

Understanding the microscopic mechanism of the fast dynamics (gigahertz-terahertz frequency range) in amorphous materials remains a challenge. Disordered systems usually exhibit two additional contributions in this frequency range in comparison to their crystalline counterparts: a low-frequency excess vibrations, the so-called boson peak, and the fast picosecond relaxation that appears as a quasielastic scattering (QES) in the light- and neutron-scattering spectra. The nature of both contributions remains a subject of active discussions. In particular, QES intensity varies significantly with temperature. These variations might be caused by pure thermal effect and/or by change in density. To separate these two contributions we performed detailed light (Raman and Brillouin) scattering studies of the fast dynamics at different experimental conditions: isothermal, isobaric, isokinetic, and isochoric. The analysis demonstrates that the volume contribution dominates the fast relaxation behavior in a liquid state while the thermal energy becomes more important in the glassy state. Moreover, the presented analysis of the light-scattering data reveals significant difference in sensitivity of the fast dynamics to pressure among seven glass-forming materials (van der Waals-bonding and hydrogen-bonding molecular systems and polymers) studied in this work. It appears that the fast dynamics in orthoterphenyl and glycerol depends on pressure (density) significantly weaker than in other materials. However, the earlier observed correlations between pressure-induced variations in the QES and boson peak intensities and between the boson peak frequency and intensity are confirmed for all the studied materials. The obtained experimental results are compared to predictions of different models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Diagnostics for Undersampling and Clustering in Monte Carlo Criticality Calculations

For the past 40 years, it has been known from the theoretical work of Gelbard [1] and Brissenden [2] that the results from Monte Carlo (MC) criticality calculations are biased if the number of neutrons per generation is not sufficiently large. The computed k-effective eigenvalue will be lower than the actual eigenvalue, and the computed eigenfunction will be too low in high-importance regions and too high in low-importance regions. This difficulty is commonly called the undersampling problem for criticality calculations. The biases for undersampling were confirmed for practical, realistic problems with modern MC codes by Brown [3]. The solution to undersampling is simple - use a larger number of neutrons per generation to reduce the biases to levels that are negligible. Over the past few years, the OECD-NEA-WPNCS Expert Group on Advanced Monte Carlo Techniques (EGAMCT) [4,5,6] investigated an extreme form of undersampling called clustering. When the number of neutrons per generation is small, neutrons in successive generations tend to group together (cluster) due to correlations, and the clusters tend to migrate through the problem space. While the problems of undersampling and clustering are well known and well understood theoretically, there were no existing diagnostics for MC codes to determine whether a given calculation is using sufficient neutrons per generation to eliminate these problems. That is, no tools were available to diagnose biases due to undersampling or clustering. The tools described herein resolve this longstanding problem by providing 2 robust methods for detecting undersampling and clustering in MC criticality calculations. The diagnosis of undersampling and clustering is part of a larger effort to thoroughly overhaul the calculational methods for criticality problems, providing for automated sampling of the initial fission distribution, acceleration of the iteration convergence process, automated detection of convergence in the iterations and starting of the active tally cycles, and the diagnosis of undersampling. All of these new methods have been prototyped in a local modified version of mcnp6.2 [7] and tested on a variety of critical systems.

74 ATOMIC AND MOLECULAR PHYSICS↗

Aqueous Solutions of the Ionic Liquid 1-butyl-3-methylimidazolium Chloride Denature Proteins

As we advance our understanding, ionic liquids (ILs) are finding ever broader scope within the chemical sciences including, most recently, pharmaceutical, enzymatic, and bioanalytical applications. With examples of enzymatic activity reported in both neat ILs and in IL/water mixtures, enzymes are frequently assumed to adopt a quasi-native conformation, even if little work has been carried out to date toward characterizing the conformation, dynamics, active-site perturbation, cooperativity of unfolding transitions, free energy of stabilization, or aggregation/oligomerization state of enzymes in the presence of an IL solvent component. In this study, human serum albumin and equine heart cytochrome c were characterized in aqueous solutions of the fully water-miscible IL 1-butyl-3-methylimidazolium chloride, [bmim]Cl, by small-angle neutron and X-ray scattering. At [bmim]Cl concentrations up to 25 vol.%, these two proteins were found to largely retain their higher-order structures whereas both proteins become highly denatured at the highest IL concentration studied here (i.e., 50 vol.% [bmim]Cl). The response of these proteins to [bmim]Cl is analogous to their behavior in the widely studied denaturants guanidine hydrochloride and urea which similarly lead to random coil conformations at excessive molar concentrations. Interestingly, human serum albumin dimerizes in response to [bmim]Cl, whereas cytochrome c remains predominantly in monomeric form. These results have important implications for enzymatic studies in aqueous IL media, as they suggest a facile pathway through which biocatalytic activity can be altered in these nascent and potentially green electrolyte systems.

59 BASIC BIOLOGICAL SCIENCES↗

Applications of compact accelerator-driven neutron sources: An updated assessment from the perspective of materials research in Italy

In 2005 the International Atomic Energy Agency (IAEA) in Vienna published a report [1] on ‘Development Opportunities of Small and Medium Scale Accelerator Driven Neutron Sources’ which summarized the prospect of smaller sources in supporting the large spallation neutron sources for materials characterization and instrumentation, a theme advocated by Bauer, Clausen, Mank, and Mulhauser in previous publications [2-4]. In 2010 the Union for Compact Accelerator-driven Neutron Sources (UCANS) was established [5], galvanizing cross-disciplinary collaborations on new source and neutronics development and expanded applications based on both slow-neutron scattering and other neutron-matter interactions of neutron energies ranging from 10⁻⁶ to 10² MeV [6]. Here, we first cover the recent development of ongoing and prospective projects of compact accelerator-driven neutron sources (CANS) but concentrate on prospective accelerators currently proposed in Italy. Two active R&D topics, irradiation effects on electronics and cultural heritage studies, are chosen to illustrate the impact of state-of-the-art CANS on these programs with respect to the characteristics and complementarity of the accelerator and neutronics systems as well as instrumentation development.

43 PARTICLE ACCELERATORS↗

Development of a Portable Muon Witness System

Since understanding and quantifying cosmic ray induced radioactive backgrounds in copper and germanium are important to the MAJORANA DEMONSTRATOR, methods are needed for monitoring the levels of such backgrounds produced in materials being transported and processed for the experiment. This report focuses on work conducted at Pacific Northwest National Laboratory to develop a muon witness system as a one way of monitoring induced activities. The operational goal of this apparatus is to characterize cosmic ray exposure of materials. The cosmic ray flux at the Earth’s surface is composed of several types of particles, including neutrons, muons, gamma rays and protons. These particles induce nuclear reactions, generating isotopes that contribute to the radiological background. Underground, the main mechanism of activation is by muon produced spallation neutrons since the hadron component of cosmic rays is removed at depths greater than a few tens of meters. This is a sub-dominant contributor above ground, but muons become predominant in underground experiments. For low-background experiments cosmogenic production of certain isotopes, such as 68Ge and 60Co, must be accounted for in the background budgets. Muons act as minimum ionizing particles, depositing a fixed amount of energy per unit length in a material, and have a very high penetrating power. Using muon flux measurements as a “witness” for the hadron flux, the cosmogenic induced activity can be quantified by correlating the measured muon flux and known hadronic production rates. A publicly available coincident muon cosmic ray detector design, the Berkeley Lab Cosmic Ray Detector (BLCRD), assembled by Juniata College, is evaluated in this work. The performance of the prototype is characterized by assessing its muon flux measurements. This evaluation is done by comparing data taken in identical scenarios with other cosmic ray telescopes. The prototype is made of two plastic scintillator paddles with associated electronics to measure energy depositions in coincidence in the two paddles. For this particular application of the prototype, the measurements performed concentrated on a broad investigation of the dependence of the muon flux on depth underground. These tests were conducted inside at Building 3420/1307 and underground at Building 3425 at the Pacific Northwest National Laboratory. The second half of this report analyzes modifications to the electronics of the BLCRD to make this detector portable. Among other modifications, a battery powered version of these electronics is proposed for the final Muon Witness design.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗