Search NASA⌕ Search

SEARCH · Search NASA

Results for “Node selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Friends or Foes: Fundamental Principles of Th-Organic Scaffold Chemistry Using Zr-Analogs as a Guide

The fundamental interest in actinide chemistry, particularly for the development of thorium-based materials, is experiencing a renaissance owing to the recent and rapidly growing attention to fuel cycle reactors, radiological daughters for nuclear medicine, and efficient nuclear stockpile development. Herein, we uncover fundamental principles of thorium chemistry on the example of Th-based extended structures such as metal–organic frameworks in comparison with the discrete systems and zirconium extended analogs, demonstrating remarkable over two-and-half-year chemical stability of Th-based frameworks as a function of metal node connectivity, amount of defects, and conformational linker rigidity through comprehensive spectroscopic and crystallographic analysis as well as theoretical modeling. Despite exceptional chemical stability, we report the first example of studies focusing on the reactivity of the most chemically stable Th-based frameworks in comparison with the discrete Th-based systems such as metal–organic complexes and a cage, contrasting multicycle recyclability and selectivity (>97%) of the extended structures in comparison with the molecular compounds. Altogether, the presented work not only establishes the conceptual foundation for evaluating the capabilities of Th-based materials but also represents a milestone for their multifaceted future and foreshadows their potential to shape the next era of actinide chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiological Risk Assessment of Capstone Depleted Uranium Aerosols

Assessment of the health risk from exposure to aerosols of depleted uranium (DU) is an important outcome of the Capstone aerosol studies that established exposure ranges to personnel in armored combat vehicles perforated by DU munitions. Although the radiation exposure from DU is low, there is concern that DU deposited in the body may increase cancer rates. Radiation doses to various organs of the body resulting from the inhalation of DU aerosols measured in the Capstone studies were calculated using International Commission on Radiological Protection (ICRP) models. Organs and tissues with the highest calculated committed equivalent 50-yr doses were lung and extrathoracic tissues (nose and nasal passages, pharynx, larynx, mouth and thoracic lymph nodes). Doses to the bone surface and kidney were about 5 to 10% of the doses to the extrathoracic tissues. The methodologies of the ICRP International Steering Committee on Radiation Standards (ISCORS) were used for determining the whole body cancer risk. Organ-specific risks were estimated using ICRP and U.S. Environmental Protection Agency (EPA) methodologies. Risks for crewmembers and first responders were determined for selected scenarios based on the time interval of exposure and for vehicle and armor type. The lung was the organ with the highest cancer mortality risk, accounting for about 97% of the risks summed from all organs. The highest mean lifetime risk for lung cancer for the scenario with the longest exposure time interval (2 h) was 0.42%. This risk is low compared with the natural or background risk of 7.35%. These risks can be significantly reduced by using an existing ventilation system (if operable) and by reducing personnel time in the vehicle immediately after perforation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A crust and upper mantle model of Eurasia and North Africa for Pn travel time calculation

We develop a Regional Seismic Travel Time (RSTT) model and methods to account for the first-order effect of the three-dimensional crust and upper mantle on travel times. The model parameterization is a global tessellation of nodes with a velocity profile at each node. Interpolation of the velocity profiles generates a 3-dimensional crust and laterally variable upper mantle velocity. The upper mantle velocity profile at each node is represented as a linear velocity gradient, which enables travel time computation in approximately 1 millisecond. This computational speed allows the model to be used in routine analyses in operational monitoring systems. We refine the model using a tomographic formulation that adjusts the average crustal velocity, mantle velocity at the Moho, and the mantle velocity gradient at each node. While the RSTT model is inherently global and our ultimate goal is to produce a model that provides accurate travel time predictions over the globe, our first RSTT tomography effort covers Eurasia and North Africa, where we have compiled a data set of approximately 600,000 Pn arrivals that provide path coverage over this vast area. Ten percent of the tomography data are randomly selected and set aside for testing purposes. Travel time residual variance for the validation data is reduced by 32%. Based on a geographically distributed set of validation events with epicenter accuracy of 5 km or better, epicenter error using 16 Pn arrivals is reduced by 46% from 17.3 km (ak135 model) to 9.3 km after tomography. Relative to the ak135 model, the median uncertainty ellipse area is reduced by 68% from 3070 km{sup 2} to 994 km{sup 2}, and the number of ellipses with area less than 1000 km{sup 2}, which is the area allowed for onsite inspection under the Comprehensive Nuclear Test Ban Treaty, is increased from 0% to 51%.

58 GEOSCIENCES↗

LaRIS: Targeting Portability and Productivity for LAPACK Codes on Extreme Heterogeneous Systems by Using IRIS

In keeping with the trend of heterogeneity in high-performance computing, hardware manufacturers and vendors are developing new architectures and associated software stacks (e.g., libraries) to harness the best possible performance from commonly used kernels (e.g., linear algebra kernels). However, kernels tuned for one architecture are not portable to others. Moreover, the coexistence of different architectures in a single node makes orchestration difficult. To address these challenges, we introduce LaRIS, a portable framework for LAPACK functionalities. LaRIS ensures a separation between linear algebra algorithms and vendor-library kernels by using the IRIS run time and IRIS-BLAS library. Such abstraction at the algorithm level makes the implementation completely agnostic to the vendor library and architecture. LaRIS uses the IRIS run time to dynamically select the vendor-library kernel and suitable processor architecture at run time. Through LU factorization, we demonstrate that LaRIS can fully utilize different heterogeneous systems by launching and orchestrating different vendor-library kernels without any change in the source code.

Monil, M. A. H.↗

HydraGNN_Predictive_GFM_2024 - Ensemble of predictive graph foundation models for ground state atomistic materials modeling

We provide the ensemble of fifteen pre-trained graph foundation models (GFMs) for atomistic materials modeling applications. Each one of the fifteen GFMs has been trained on five open-source datasets that (once aggregated) amount to over 154 million atomistic structures, which cover over two-thirds of the natural elements of the periodic table and that comprises a broad set of organic and inorganic compounds. This vast set of atomistic structures comprises ground state configurations that are dynamically stable (i.e., equilibrated structures with atomic forces approximately close to zero values) as well as dynamically unstable structures (i.e., non-equilibrium structures with non-negligible non-zero values of atomic forces). The ensemble of datasets aggregated does NOT include excited states. The datasets have been curated to remove atomistic structures with spectral norm of the force tensor above 100 eV/angstrom. Moreover, a linear term of the energy was computed for each dataset using a linear regression model that uses the chemical concentration of each natural element as regressor. The linear term predicted by the linear regression model has been subtracted from each original energy value to perform a re-alignment of the energy values across different electronic structures approximation theories performed to generate the diverse multi-source, multi-fidelity datasets. The folder "ADIOS_files" contains the set of pre-processed datasets in Adaptable I/O System (ADIOS) format (https://www.exascaleproject.org/research-project/adios/) that have been used for the development and training of GFMs in this work. The "ADIOS_files" directory contains 6 sub-directories named as follows: - ANI1x-v3.bp - MPTrj-v3.bp - OC2020-20M-v3.bp - OC2020-v3.bp - OC2022-v3.bp - qm7x-v3.bp Each sub-directory contains the pre-processed datasets converted in Adaptable I/O System (ADIOS) format (https://www.exascaleproject.org/research-project/adios/) that have been used to the development, training, and performance testing of the ensemble go predictive graph foundation models. Each GFM was developed using HydraGNN (https://github.com/ORNL/HydraGNN) as underlying graph neural network (GNN) architecture. The multi-task learning (MTL) capability of HydraGNN was used to simultaneously train the GFMs on labeled values for direct predictions of energy (a total system property of an atomistic structure that measures the chemical stability) and atomic forces (an atomic level property of an atomistic structure that measures the dynamical stability). The hyper parameters of the GFM have been tuned using scalable hyperparameter optimization (HPO) algorithms implemented in the software DeepHyper (https://github.com/deephyper/deephyper). The pre-training of each HPO trial was performed using distributed data parallelism (DDP) to scale the training across 128 compute nodes of the exascale OLCF supercomputer Frontier. Each HPO trial was trained only for 10 epochs and an early stopping was performed to avoid wasting significant computational resources on GNN architectures that were clearly underperforming. For each HPO trial, the 'omnistat' tool developed by (AMD Research - Advanced Micro Device) was used to measure the total energy consumption in kWh. The ensemble of GFMs was obtained by selecting the fifteen best performing HPO trials. Four models have been selected for their clear advantage in accuracy, and these are the GFMs with IDs 229, 156, 147, 260. Additional eleven models have been selected based on judicious balance between accuracy and energy consumption needed for training, and these are the GFMs with IDs 165, 78, 137, 1, 175, 171, 181, 67, 179, 167, 351. Each selected GFM of the ensemble was continued to cumulate a total of at most 30 epochs. In some cases, the total number of epochs actually performed was les than 30 due to two combined factors: (1) the size of the GFM (i.e., the number of model parameters to train) and (2) the total wall-clock time for which the computational resources could be allocated on OLCF-Frontier. The "Ensemble_of_models" directory contains 15 sub-directories named as follows: - gfm_0.229 - gfm_0.156 - gfm_0.147 - gfm_0.260 - gfm_0.165 - gfm_0.78 - gfm_0.137 - gfm_0.1 - gfm_0.175 - gfm_0.171 - gfm_0.181 - gfm_0.67 - gfm_0.179 - gfm_0.167 - gfm_0.351 Each one of these sub-directories refers to one of the fifteen HPO trials that have been selected to continue the pre-training with at most 30 epochs. With each sub-directory associated with a specific HPO trial, the following files can be found: - config.json: file for argument parsing to develop and train an HydraGNN architecture - gfm_0.ID_epoch_N.pk: file with model parameters for HPO ID trial after N epochs of training The ensemble of fifteen GFM architectures was used for (1) ensemble averaging to stabilize the predictions of energy and atomic forces after pre-training for post-processing analysis and (2) ensemble uncertainty quantification (UQ). The code used to develop, pre-train, and load the pre-trained models for post-processing analysis is available on the ORNL-GitHub at the following link: https://github.com/ORNL/HydraGNN/tree/Predictive_GFM_2024

36 MATERIALS SCIENCE↗

Final Scientific Report: A Scalable Development Environment for Peta-Scale Computing

This document is the final scientific report of the project DE-SC000120 (A scalable Development Environment for Peta-Scale Computing). The objective of this project is the extension of the Parallel Tools Platform (PTP) for applying it to peta-scale systems. PTP is an integrated development environment for parallel applications. It comprises code analysis, performance tuning, parallel debugging and system monitoring. The contribution of the Juelich Supercomputing Centre (JSC) aims to provide a scalable solution for system monitoring of supercomputers. This includes the development of a new communication protocol for exchanging status data between the target remote system and the client running PTP. The communication has to work for high latency. PTP needs to be implemented robustly and should hide the complexity of the supercomputer's architecture in order to provide a transparent access to various remote systems via a uniform user interface. This simplifies the porting of applications to different systems, because PTP functions as abstraction layer between parallel application developer and compute resources. The common requirement for all PTP components is that they have to interact with the remote supercomputer. E.g. applications are built remotely and performance tools are attached to job submissions and their output data resides on the remote system. Status data has to be collected by evaluating outputs of the remote job scheduler and the parallel debugger needs to control an application executed on the supercomputer. The challenge is to provide this functionality for peta-scale systems in real-time. The client server architecture of the established monitoring application LLview, developed by the JSC, can be applied to PTP's system monitoring. LLview provides a well-arranged overview of the supercomputer's current status. A set of statistics, a list of running and queued jobs as well as a node display mapping running jobs to their compute resources form the user display of LLview. These monitoring features have to be integrated into the development environment. Besides showing the current status PTP's monitoring also needs to allow for submitting and canceling user jobs. Monitoring peta-scale systems especially deals with presenting the large amount of status data in a useful manner. Users require to select arbitrary levels of detail. The monitoring views have to provide a quick overview of the system state, but also need to allow for zooming into specific parts of the system, into which the user is interested in. At present, the major batch systems running on supercomputers are PBS, TORQUE, ALPS and LoadLeveler, which have to be supported by both the monitoring and the job controlling component. Finally, PTP needs to be designed as generic as possible, so that it can be extended for future batch systems.

97 MATHEMATICS AND COMPUTING↗

Analysis of nodal coverage utilizing image guided radiation therapy for primary gynecologic tumor volumes

Purpose: To evaluate radiation dose delivered to pelvic lymph nodes, if daily Image Guided Radiation Therapy (IGRT) was implemented with treatment shifts based on the primary site (primary clinical target volume [CTV]). Our secondary goal was to compare dosimetric coverage with patient outcomes. Materials and methods: A total of 10 female patients with gynecologic malignancies were evaluated retrospectively after completion of definitive intensity-modulated radiation therapy (IMRT) to their pelvic lymph nodes and primary tumor site. IGRT consisted of daily kilovoltage computed tomography (CT)-on-rails imaging fused with initial planning scans for position verification. The initial plan was created using Varian's Eclipse treatment planning software. Patients were treated with a median radiation dose of 45 Gy (range: 37.5 to 50 Gy) to the primary volume and 45 Gy (range: 45 to 64.8 Gy) to nodal structures. One IGRT scan per week was randomly selected from each patient's treatment course and re-planned on the Eclipse treatment planning station. CTVs were recreated by fusion on the IGRT image series, and the patient's treatment plan was applied to the new image set to calculate delivered dose. We evaluated the minimum, maximum, and 95% dose coverage for primary and nodal structures. Reconstructed primary tumor volumes were recreated within 4.7% of initial planning volume (0.9% to 8.6%), and reconstructed nodal volumes were recreated to within 2.9% of initial planning volume (0.01% to 5.5%). Results: Dosimetric parameters averaged less than 10% (range: 1% to 9%) of the original planned dose (45 Gy) for primary and nodal volumes on all patients (n = 10). For all patients, ≥99.3% of the primary tumor volume received ≥ 95% the prescribed dose (V95%) and the average minimum dose was 96.1% of the prescribed dose. In evaluating nodal CTV coverage, ≥ 99.8% of the volume received ≥ 95% the prescribed dose and the average minimum dose was 93%. In evaluating individual IGRT sessions, we found that 6 patients had an estimated minimal nodal CTV dose less than 90% (range: 78 to 99%) of that planned. With a median follow-up of 42.5 months, 2 patients experienced systemic disease progression at an average of 19.6 months. One patient was found to have a local or regional failure with an average follow-up of 42 months. Conclusion: Using only 3 dimensional IGRT corrections in gynecological radiation allows excellent coverage of the primary target volume and good average nodal CTV coverage. If IGRT corrections are based on alignment to the primary tumor volume, and is only able to be corrected in 3 degrees, this can create situations in which nodal volumes may be under dosed. Utilizing multiple IGRT sessions appears to average out dose discrepancies over the course of treatment. The implication of underdosing in a single IGRT session needs further evaluation in future studies. Based on the concern of minimum dose to a nodal target volume, these findings may signal caution when using IGRT and IMRT in gynecological radiation patients. Possible techniques to overcome this situation may include averaging shifts between tumor and nodal volume, use of a treatment couch with 6° of freedom, deformable registration, or adaptive planning.

61 RADIATION PROTECTION AND DOSIMETRY↗

Neoadjuvant Chemoradiation With Paclitaxel/Carboplatin for Selected Stage III Non-Small-Cell Lung Cancer: Long-Term Results of a Trimodality Phase II Protocol

Purpose: To evaluate, in a Phase II trial conducted August 1998 through January 2001, the efficacy of neoadjuvant chemotherapy followed by chemoradiotherapy and definitive surgery in patients with locally advanced non-small-cell lung cancer (LA-NSCLC), Stages IIIA bulky and selected Stage IIIB. Patients and Methods: Staging of LA-NSCLC included computed tomography of cranium, thorax, and abdomen, whole-body positron emission tomography, and video mediastinoscopy. Induction chemotherapy with weekly paclitaxel and carboplatin was followed by hyperfractionated accelerated thoracic radiotherapy (45 Gy) with simultaneous weekly paclitaxel and carboplatin. Four to six weeks after completion of induction therapy, restaging and resection of primary tumor and lymph nodes was intended. Results: A total of 59 consecutive patients were enrolled, 25% with Stage IIIA bulky disease, 65% with Stage IIIB, and 10% with Stage IV (excluded from further analysis). Forty-one patients completed induction therapy; in 52.4% a functional (positron emission tomography) downstaging was proven. Thirty-two patients (59.3%) underwent complete tumor resection, and 5 patients had an exploratory thoracotomy only. Histopathologic downstaging was proven in 59.4% and complete response in 21.9%. Hospital mortality was 5.4%. Median duration of follow-up for living patients was 62.1 months. Overall median survival was 22.6 months, 58.2 months for completely resected patients. During induction chemotherapy, Grade 3/4 granulocytopenia occurred in 8% of patients; the most common Grade 3/4 toxicity of chemoradiation was esophagitis, in 26.4% of patients. Conclusions: Induction paclitaxel/carboplatin with hyperfractionated accelerated chemoradiotherapy followed by complete tumor resection demonstrates high efficacy in LA-NSCLC and offers a promising chance of long-term survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Lateral Conduction in a Rectangular Fuel Plate and Optimum Stripe Widths for the OPAL Reactor

The impetus for this work is the Proliferation Resistance Optimization (PRO-X) program, which was created by the National Nuclear Security Administration (NNSA) of the US Department of Energy (DOE) to provide a framework for developing reactor designs that minimize the production of special nuclear materials while maximizing performance for peaceful uses. The Argentine company INVAP and Argonne National Laboratory collaborated to share knowledge and expertise regarding the thermal analysis of research reactors. Working together, they designed a series of test problems based on the Open Pool Australian Light Water (OPAL) reactor, whose fuel is in the form of flat plates cooled by water flowing through narrow rectangular channels. ANL used their PLTEMP/ANL code. INVAP used their TERMIC code (and its new multi-plate version, TERMIC-MP). Then, INVAP and ANL compared the two sets of results. 1-D models were used during the collaboration since for research reactor analysis, largely 1-D thermal-hydraulics models are commonly used because they are simple to apply and technically defendable. The collaboration between the two organizations aims for improvements in thermal-hydraulic models. Improvements to methods and models can reduce modeling uncertainties and excessive conservatism, allowing greater reactor performance without reducing predicted safety margins. Therefore, these improvements potentially expand the design space, making additional designs feasible, which, in turn, may achieve better fuel utilization and proliferation resistance in the designs. This report provides justification for the lateral node size (stripe width) chosen for the 1-D computer models during the collaboration. The lateral heat conduction in OPAL fuel plates is evaluated using the two-dimensional conduction capability of PLTEMP/ANL to determine a representative hot-stripe width that can be conservatively used for one-dimensional steady-state thermal-hydraulic analysis. Basically, a representative hot-stripe width needs to be selected so that the actual heat flux averaged over this stripe width is greater than or equal to the maximum heat flux obtained by the two-dimensional analysis. Detailed results in this report show that a hot-stripe width of 8.125 mm can be conservatively used for the one-dimensional thermal-hydraulics analysis of all plates. Therefore, eight equal stripes (8.125 mm each) are recommended to be modeled in the MCNP and PLTEMP/ANL full core models of the OPAL reactor.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Significance of ERBB2 Overexpression in Therapeutic Resistance and Cancer-Specific Survival in Muscle-Invasive Bladder Cancer Patients Treated With Chemoradiation-Based Selective Bladder-Sparing Approach

Purpose: To investigate the associations of ERBB 2 overexpression with chemoradiation therapy (CRT) resistance and cancer-specific survival (CSS) in muscle-invasive bladder cancer (MIBC) patients treated with the CRT-based bladder-sparing protocol. Methods and Materials: From 1997 to 2012, 201 patients with cT2-4aN0M0 bladder cancer were treated with CRT (40 Gy with concurrent cisplatin) following transurethral resection of bladder tumor (TURBT). Basically, patients with tumors that showed good CRT response and were amenable to segmental resection underwent partial cystectomy (PC) with pelvic lymph node dissection for bladder preservation; otherwise, radical cystectomy (RC) was recommended. Included in this study were 119 patients in whom TURBT specimens were available for immunohistochemical analysis of ERBB 2 expression. Following CRT, 30 and 65 patients underwent PC or RC, respectively; the remaining 24 patients did not undergo cystectomy. Tumors were defined as CRT-resistant when patients did not achieve complete response after CRT. Associations of ERBB 2 overexpression with CRT resistance and CSS were evaluated. Results: CRT resistance was observed clinically in 56% (67 of 119 patients) and pathologically (in cystectomy specimens) in 55% (52 of 95 patients). ERBB 2 overexpression was observed in 45 patients (38%). On multivariate analysis, ERBB 2 overexpression was an independent predictor for CRT resistance clinically (odds ratio, 3.6; P=.002) and pathologically (odds ratio, 2.9; P=.031). ERBB 2 overexpression was associated with shorter CSS (5-year CSS rates, 56% vs 87% for the ERBB 2 overexpression group vs the others; P=.001). ERBB 2 overexpression was also an independent risk factor for bladder cancer death at all time points of our bladder-sparing protocol (pre-CRT, post-CRT, and post-cystectomy). Conclusions: ERBB 2 overexpression appears relevant to CRT resistance and unfavorable CSS in MIBC patients treated with the CRT-based bladder-sparing protocol. ERBB 2-targeting treatment may improve the outcomes of such patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Role of Definitive Radiation Therapy in Carcinoma of Unknown Primary in the Abdomen and Pelvis

Objectives: Carcinoma of unknown primary (CUP) in the abdomen and pelvis is a heterogeneous group of cancers with no standard treatment. Considered by many to be incurable, these patients are often treated with chemotherapy alone. In this study, we determined the effectiveness of radiation therapy in combination with chemotherapy in patients with CUP in the abdomen and pelvis. Patients and Methods: Medical records were reviewed for 37 patients with CUP treated with radiation therapy for disease located in the soft tissues and/or nodal basins of the abdomen and pelvis at University of Texas M.D. Anderson Cancer between 2002 and 2009. All patients underwent chemotherapy, either before or concurrent with radiation therapy. Patients were selected for radiation therapy on the basis of histologic type, disease extent, and prior therapy response. Twenty patients underwent definitive radiation therapy (defined as radiation therapy targeting all known disease sites with at least 45 Gy) and 17 patients underwent palliative radiation therapy. Only 6 patients had surgical resection of their disease. Patient and treatment characteristics were extracted and the endpoints of local disease control, progression-free survival (PFS), overall survival (OS), and treatment-related toxicity incidence were analyzed. Results: The 2-year PFS and OS rates for the entire cohort were 32% and 57%, respectively. However, in patients treated with definitive radiation therapy, the rates were 48% and 76%, and 7 patients lived more than 3 years after treatment with no evidence of disease progression. Nevertheless, radiation-associated toxicity was significant in this cohort, as 40% experienced Grade 2 or higher late toxicities. Conclusions: The use of definitive radiation therapy should be considered in selected patients with CUP in the soft tissues or nodal basins of the abdomen and pelvis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Heat transfer optimization of uo 2 -mo fuel using genetic algorithms

Two genetic algorithm (GA) methods were applied to thermal finite element models to optimize the heat transfer efficacy of a UO 2 -Mo composite fuel pellet with typical pressurized water reactor fuel geometry. Mo additions to UO 2 have been shown to increase the thermal conductivity, thus reducing centerline temperatures and temperature gradients. Previous studies evaluated uniformly dispersed Mo or continuous Mo internal geometries (e.g., fins, plates, discs) that were selected using engineering intuition. The current study uses two different implementations of the same GA to optimize Mo placement and minimize the fuel temperature with the only constraint being a maximum 10% Mo volume fraction. One approach superimposed Mo line elements onto the monolithic UO 2 pellet model, and the other converted entire UO 2 volume elements to Mo. The former method generated 1D heat transfer connections between nodes, whereas the latter method allowed for the formation of 3D structures. Features of the optimal fuel design produced by the GAs included dispersed Mo near the centerline that shifted the peak fuel temperature outward by 0.6 mm, Mo chains in the high-heat-flux region in the mid-to-outer radial zone, and a large continuous structure that spanned the full radius and height of the pellet and accounted for 87.7 % of the total Mo in the pellet. Analysis of this design indicates that the optimal Mo configuration is a balance between creating continuous heat transfer pathways and optimally dispersing Mo to minimize the heat transfer distance through UO 2 . This architecture ultimately produced an effective thermal conductivity of 11.3 W/m·K under the assumed boundary conditions. This result is higher than any previous values from the literature. In conclusion, potential fabrication methods and challenges are discussed in addition to the implications on fuel performance.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A User’s Guide to the PLTEMP/ANL Code (V.4.3)

PLTEMP/ANL V4.3 is a program that obtains a steady-state flow and temperature solution for a nuclear reactor core, or for a single fuel assembly. It is based on an evolutionary sequence of codes originally used for plate temperatures, hence “PLTEMP”, developed at Argonne National Laboratory over several decades. Fueled and non-fueled regions are modeled. Each fuel assembly consists of one or more plates or tubes separated by coolant channels. The fuel plates may have one to five layers of different materials, each with heat generation. The width of a fuel plate may be divided into multiple longitudinal stripes, each with its own axial power shape. Depending upon the heat transfer method selected, the temperature solution is effectively 2-dimensional or 3-dimensional (Appendix XV). It should be noted that for a 3-dimensional solution the axial power shape is modeled without accounting for axial heat conduction. It begins with a solution across all coolant channels and fuel plates or tubes within a given fuel assembly, at the entrance to the assembly. The temperature solution is repeated for each axial node along the length of the fuel assembly. The geometry may be either slab or radial, corresponding to fuel assemblies made of a series of flat (or slightly curved) plates, or of nested tubes. A variety of thermal-hydraulic correlations are available to determine safety margins such as onset-of-nucleate boiling ratio(ONBR), departure from nucleate boiling ratio (DNBR), and onset of flow instability ratio (OFIR). Coolant properties for either light or heavy water are obtained from FORTRAN functions rather than from tables. The code is intended for thermal-hydraulic analysis of research reactor performance in the sub-cooled boiling regime. Both turbulent and laminar flow regimes can be modeled. Options to calculate both forced flow and natural circulation are available. A general search capability is available (Appendix XII) to greatly reduce the reactor analyst’s time.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Alignment Focus of Daily Image Guidance for Concurrent Treatment of Prostate and Pelvic Lymph Nodes

Purpose: To determine the dosimetric impact of daily imaging alignment focus on the prostate soft tissue versus the pelvic bones for the concurrent treatment of the prostate and pelvic lymph nodes (PLN) and to assess whether multileaf collimator (MLC) tracking or adaptive planning (ART) is necessary with the current clinical planning margins of 8 mm/6 mm posterior to the prostate and 5 mm to the PLN. Methods and Materials: A total of 124 kilovoltage cone-beam computed tomography (kV-CBCT) images from 6 patients were studied. For each KV-CBCT, 4 plans were retrospectively created using an isocenter shifting method with 2 different alignment focuses (prostate, PLN), an MLC shifting method, and the ART method. The selected dosimetric endpoints were compared among these plans. Results: For the isoshift contour, isoshift bone, MLC shift, and ART plans, D99 of the prostate was ≥97% of the prescription dose in 97.6%, 73.4%, 98.4%, and 96.8% of 124 fractions, respectively. Accordingly, D99 of the PLN was ≥97% of the prescription dose in 98.4%, 98.4%, 98.4%, and 100% of 124 fractions, respectively. For the rectum, D5 exceeded 105% of the planned D5 (and D5 of ART plans) in 11% (4%), 10% (2%), and 13% (5%) of 124 fractions, respectively. For the bladder, D5 exceeded 105% of the planned D5 (and D5 of ART) plans in 0% (2%), 0% (2%), and 0% (1%) of 124 fractions, respectively. Conclusion: For concurrent treatment of the prostate and PLN, with a planning margin to the prostate of 8 mm/6 mm posterior and a planning margin of 5 mm to the PLN, aligning to the prostate soft tissue can achieve adequate dose coverage to the both target volumes; aligning to the pelvic bone would result in underdosing to the prostate in one-third of fractions. With these planning margins, MLC tracking and ART methods have no dosimetric advantages.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Queue wait time prediction in high performance computing (HPC) systems

High Performance Computing (HPC) systems are critical enablers for groundbreaking scientific research across various domains. Efficient resource allocation, facilitated by job scheduling, is paramount for maximizing the utilization of HPC systems. However, the variability in wait times for queued jobs poses challenges for users, necessitating accurate job wait time estimation. This paper explores the influence of job characteristics, including job size (the number of nodes requested and walltime), the queue to which the job is submitted and other resource requirements, on job wait times in leadership-class HPC systems. Focusing on the Theta Cray XC40 and Polaris machines at Argonne National Laboratory, the study evaluates the performance of different supervised learning algorithms in predicting job wait times. It also evaluates the impact of data preprocessing, including outlier detection, Principal Component Analysis (PCA), and feature selection, on the performance of wait time prediction models. The findings reveal insights into the relationship between job characteristics and wait times, offering a foundation for optimizing resource allocation and enhancing user experience. The methodologies and tools developed in this study are adaptable to other leadership-class HPC systems, providing a valuable contribution to the broader HPC community aiming to improve job scheduling efficiency and user satisfaction.

Okafor, Nwamaka↗

Parallel beamlet dose calculation via beamlet contexts in a distributed multi‐GPU framework

Purpose Dose calculation is one of the most computationally intensive, yet essential tasks in the treatment planning process. With the recent interest in automatic beam orientation and arc trajectory optimization techniques, there is a great need for more efficient model‐based dose calculation algorithms that can accommodate hundreds to thousands of beam candidates at once. Foundational work has shown the translation of dose calculation algorithms to graphical processing units ( GPU s), lending to remarkable gains in processing efficiency. But these methods provide parallelization of dose for only a single beamlet, serializing the calculation of multiple beamlets and under‐utilizing the potential of modern GPU s. In this paper, the authors propose a framework enabling parallel computation of many beamlet doses using a novel beamlet context transformation and further embed this approach in a scalable network of multi‐ GPU computational nodes. Methods The proposed context‐based transformation separates beamlet‐local density and TERMA into distinct beamlet contexts that independently provide sufficient data for beamlet dose calculation. Beamlet contexts are arranged in a composite context array with dosimetric isolation, and the context array is subjected to a GPU collapsed‐cone convolution superposition procedure, producing the set of beamlet‐specific dose distributions in a single pass. Dose from each context is converted to a sparse representation for efficient storage and retrieval during treatment plan optimization. The context radius is a new parameter permitting flexibility between the speed and fidelity of the dose calculation process. A distributed manager‐worker architecture is constructed around the context‐based GPU dose calculation approach supporting an arbitrary number of worker nodes and resident GPU s. Phantom experiments were executed to verify the accuracy of the context‐based approach compared to Monte Carlo and a reference CPU ‐ CCCS implementation for single beamlets and broad beams composed by addition of beamlets. Dose for representative 4 π beam sets was calculated in lung and prostate cases to compare its efficiency with that of an existing beamlet‐sequential GPU ‐ CCCS implementation. Code profiling was also performed to evaluate the scalability of the framework across many networked GPU s. Results The dosimetric accuracy of the context‐based method displays <1.35% and 2.35% average error from the existing serialized CPU ‐ CCCS algorithm and Monte Carlo simulation for beamlet‐specific PDD s in water and slab phantoms, respectively. The context‐based method demonstrates substantial speedup of up to two orders of magnitude over the beamlet‐sequential GPU ‐ CCCS method in the tested configurations. The context‐based framework demonstrates near linear scaling in the number of distributed compute nodes and GPU s employed, indicating that it is flexible enough to meet the performance requirements of most users by simply increasing the hardware utilization. Conclusions The context‐based approach demonstrates a new expectation of performance for beamlet‐based dose calculation methods. This approach has been successful in accelerating the dose calculation process for very large‐scale treatment planning problems ‐ such as automatic 4 π IMRT beam orientation and VMAT arc trajectory selection, with hundreds of thousands of beamlets ‐ in clinically feasible timeframes. The flexibility of this framework makes it as a strong candidate for use in a variety of other very large‐scale treatment planning tasks and clinical workflows.

Neph, Ryan↗

Detection of early stage atherosclerotic plaques using PET and CT fusion imaging targeting P-selectin in low density lipoprotein receptor-deficient mice

Highlights: ► P-selectin regulates leukocyte recruitment as an early stage event of atherogenesis. ► We developed an antibody-based molecular imaging probe targeting P-selectin for PET. ► This is the first report on successful PET imaging for delineation of P-selectin. ► P-selectin is a candidate target for atherosclerotic plaque imaging by clinical PET. -- Abstract: Background: Sensitive detection and qualitative analysis of atherosclerotic plaques are in high demand in cardiovascular clinical settings. The leukocyte–endothelial interaction mediated by an adhesion molecule P-selectin participates in arterial wall inflammation and atherosclerosis. Methods and results: A {sup 64}Cu-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid conjugated anti-P-selectin monoclonal antibody ({sup 64}Cu-DOTA-anti-P-selectin mAb) probe was prepared by conjugating an anti-P-selectin monoclonal antibody with DOTA followed by {sup 64}Cu labeling. Thirty-six hours prior to PET and CT fusion imaging, 3 MBq of {sup 64}Cu-DOTA-anti-P-selectin mAb was intravenously injected into low density lipoprotein receptor-deficient Ldlr-/- mice. After a 180 min PET scan, autoradiography and biodistribution of {sup 64}Cu-DOTA-anti-P-selectin monoclonal antibody was examined using excised aortas. In Ldlr-/- mice fed with a high cholesterol diet for promotion of atherosclerotic plaque development, PET and CT fusion imaging revealed selective and prominent accumulation of the probe in the aortic root. Autoradiography of aortas that demonstrated probe uptake into atherosclerotic plaques was confirmed by Oil red O staining for lipid droplets. In Ldlr-/- mice fed with a chow diet to develop mild atherosclerotic plaques, probe accumulation was barely detectable in the aortic root on PET and CT fusion imaging. Probe biodistribution in aortas was 6.6-fold higher in Ldlr-/- mice fed with a high cholesterol diet than in those fed with a normal chow diet. {sup 64}Cu-DOTA-anti-P-selectin mAb accumulated selectively in aortic atherosclerotic plaques and was detectable by PET and CT fusion imaging in Ldlr-/- mice. Conclusions: P-selectin is a candidate target molecule for early-phase detection by PET and CT fusion imaging of atherosclerotic plaques.

60 APPLIED LIFE SCIENCES↗

Hedgehog–FGF signaling axis patterns anterior mesoderm during gastrulation

Significance Anterior–posterior axis patterning is a fascinating but poorly understood developmental process. Single-cell sequencing was utilized to interrogate patterning abnormalities in a mesoderm-specific Hedgehog (Hh) pathway mutant, which revealed selective anterior mesoderm defects. We found that Hh signaling was required for fibroblast growth factor (FGF) pathway activity in nascent mesoderm during gastrulation. Mouse genetics, cell biology, and genomic experiments indicate that FGF signaling acts downstream of Hh signaling in nascent mesoderm for anterior mesoderm morphogenesis. This work demonstrates the utility of applying single-cell technologies to resolve complex developmental phenotypes. Here, it revealed a role for Hh signaling from the node in organizing anterior mesoderm morphogenesis, independent of its role in left–right determination, by promoting FGF signaling in gastrulating mesoderm.

Guzzetta, Alexander↗