Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear data analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Single-spin asymmetry for high-p{sub T} charged hadrons at negative x{sub F} in proton-nucleus collisions at an energy of 40 GeV

The transverse single-spin asymmetry was measured for charged hadrons ({pi}{sup {+-}}, K{sup {+-}}, p, p-bar) produced in proton-nucleus collisions. The measurements were performed with the aid of the FODS-2 spectrometer by using a 40-GeV polarized proton beam from the accelerator of the Institute for High Energy Physics (IHEP, Protvino) and carbon and copper nuclear targets. The data subjected to the analysis in the present study were obtained for c.m. angles in the range 95{sup o}-112{sup o} in the vicinity of the central region (-0.08 < x{sub F} < -0.06, 0.7 < p{sub T} < 3.4 GeV/c). The analyzing power is found to be only slightly dependent on the mass number of the target nucleus. The basic results obtained by measuring the single-spin asymmetry at three values of the particle-detection angle are discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Neutron Activation and Thermoluminescent Detector Responses to a Bare Pulse of the CEA Valduc SILENE Critical Assembly

This benchmark experiment was conducted as a joint venture between the US Department of Energy (DOE) and the French Commissariat à l'Energie Atomique (CEA). Staff at the Oak Ridge National Laboratory (ORNL) in the US and the Centre de Valduc in France planned this experiment. The experiment was conducted on October 11, 2010 in the SILENE critical assembly facility at Valduc. Several other organizations contributed to this experiment and the subsequent evaluation, including CEA Saclay, Lawrence Livermore National Laboratory (LLNL), the Y-12 National Security Complex (NSC), Babcock International Group in the United Kingdom, and Los Alamos National Laboratory (LANL). The goal of this experiment was to measure neutron activation and thermoluminescent dosimeter (TLD) doses from a source similar to a fissile solution critical excursion. The resulting benchmark can be used for validation of computer codes and nuclear data libraries as required when performing analysis of criticality accident alarm systems (CAASs). A secondary goal of this experiment was to qualitatively test performance of two CAAS detectors similar to those currently and formerly in use in some US DOE facilities. The detectors tested were the CIDAS MkX and the Rocky Flats NCD-91. These detectors were being evaluated to determine whether they would alarm, so they were not expected to generate benchmark quality data.

Miller, Thomas Martin↗

AGC-4 Experiment Irradiation Monitoring Data Qualification Interim Report

The Graphite Technology Development Program is running a series of six experiments to quantify the effects of irradiation on nuclear grade graphite. The fourth experiment, Advanced Graphite Creep 4 (AGC 4), began with Advanced Test Reactor (ATR) cycle 157D on May 30, 2015, and has been irradiated for two cycles. The capsule was removed from the reactor after ATR cycle 158A, which ended on January 2, 2016, due to interference with another experiment. Irradiation will resume when the interfering experiment is removed from the reactor. This report documents qualification of AGC 4 experiment irradiation monitoring data for use by the Advanced Reactor Technologies (ART) Technology Development Office (TDO) Program for research and development activities required to design and license the first HTR nuclear plant. Qualified data meet the requirements for use as described in the experiment planning and quality assurance documents. Failed data do not meet the requirements and provide no useable information. Trend data may not meet all requirements, but still provide some useable information. Use of Trend data requires assessment of how any deficiencies affect a particular use of the data. All thermocouples (TCs) have functioned throughout the AGC-4 experiment. All temperature data are Qualified for use by the ART TDO Program. Argon, helium, and total gas flow data were within expected ranges and are Qualified for use by the ART TDO Program. Discharge gas line moisture values were consistently low during cycle 157D. At the start of cycle 158A, gas moisture briefly spiked to over 600 ppmv and then declined throughout the cycle. Moisture values are within the measurement range of the instrument and are Qualified for use by the ART TDO Program. Graphite creep specimens were subjected to one of three loads, 393, 491, or 589 lbf. For a brief period during cycle 157D between 12:19 on June 2, 2015 and 08:23 on June 11, 2015 the load cells were wired incorrectly resulting in missing stack load data. Missing stack loads were estimated from measured ram pressures using regression equations developed from the existing data from cycle 157D. Estimated stack loads during this period are considered to be an accurate representation of actual load applied to the stacks. These loads deviate slightly from the planned loads. This deviation does not prevent the data from being Qualified for use, but must be taken into account when analyzing the effect of load on creep. Stack displacement increased consistently throughout the first two cycles with total displacement ranging from 0.4 to 0.8 in. During ATR outages, a set of pneumatic rams raised the stacks of graphite creep specimens to ensure the specimens were not stuck within the test train. This stack raising was performed twice. All stacks were raised successfully each time. The load and displacement data are Qualified for use by the ART TDO Program.

36 MATERIALS SCIENCE↗

RESULTS FOR THE FIRST QUARTER 2009 TANK 50 WAC SLURRY SAMPLE: CHEMICAL AND RADIONUCLIDE CONTAMINANT RESULTS

This report details the chemical and radionuclide contaminant results for the characterization of the 2009 First Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC). Information from this characterization will be used by Liquid Waste Operations (LWO) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System. The following conclusions are drawn from the analytical results provided in this report: (1) The concentrations of the chemical and radioactive contaminants were all less than their respective WAC Targets or Limits except for Am-242m. (2) The radionuclide Am-242m was not detected; however, its detection limit is above the WAC Target given in Attachment 8.4. The higher detection limit was expected based on current analytical capabilities as stated in the Task Technical and Quality Assurance Plan (TTQAP). (3) The reported detection limit of isopropanol was lower than its WAC Limit for accident analysis but higher than its WAC concentration given in Table 4 for vault flammability. The higher detection limit was expected based on current analytical capabilities and is documented in the Task Technical and Quality Assurance Plan (TTQAP). (4) The reported detection limit for Isopar L is lower than its WAC limit for accident analysis in Appendix 8.1 but higher than its WAC concentration given in Table 3 in reference to vault flammability. The higher detection limit was expected based on current analytical capabilities as stated in the Task Technical and Quality Assurance Plan (TTQAP). (5) Isopar L and Norpar 13 have limited solubility in aqueous solutions making it difficult to obtain consistent and reliable sub-samples. The values reported in this memo are the concentrations in the sub-sample as detected by the GC/MS; however, the results may not accurately represent the concentrations of these analytes in Tank 50.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cosmogenic records in Antarctic meteorites

Aliquot samples of 29 Antarctic L and H chondrites are analyzed for their nuclear track records and Mn-53 activities. The track density in the analyzed samples ranges from 10 to the 4th to approximately 6 x 10 to the 6th per sq cm. A significant finding is the observation of track-rich grains in a set of four L3 chondrites (ALHA 77215, 77216, 77217, and 77252), suspected of belonging to the same fall based on petrographic observations. An additional sample, ALHA 78105, an L6 chondrite, also has track-rich grains. Mn-53 activity is at near saturation level in approximately 65 percent of the analyzed samples, suggesting exposure ages of greater than 10 m.y. in these cases. Very few H chondrites from the 7-m.y. exposure age peak are apparently sampled among the ones investigated in this study. Approximately 6 percent and 4 percent, respectively, of the Antarctic H and L chondrites analyzed thus far for their cosmogenic records have precompaction irradiation features. A combined analysis of Mn-53 and nuclear track data makes it possible to confirm or rule out the proposed pairing of several sets of Antarctic meteorites and to estimate the preatmospheric sizes of some of these meteorites. The results suggest that most of the small Antarctic meteorites (less than 1 kg) have suffered high (greater than 95 percent) ablation mass-loss.

Goswami, J. N.↗

A Comparison of the Irradiation Creep Behavior of Several Graphites

Graphite creep strain data from the irradiation creep capsule Advanced Graphite Creep-1 (AGC-1) are reported. This capsule was the first (prototype) of a series of five or six capsules planned as part of the AGC experiment, which was designed to fully characterize the effects of neutron irradiation and the radiation creep behavior of current nuclear graphite. The creep strain data and analysis are reported for the six graphite grades incorporated in the capsule. The AGC-1 capsule was irradiated in the Advanced Test Reactor at Idaho National Laboratory (INL) at approximately 700 C and to a peak dose of 7 dpa (displacements per atom). The specimen s final dose, temperature, and stress conditions have been reported by INL and were used during this analysis. The derived creep coefficients (K) were calculated for each grade and were found to compare well to literature data for the creep coefficient, even under the wide range of AGC-1 specimen temperatures. Comparisons were made between AGC-1 data and historical grade data for creep coefficients.

Graphite↗

Modernization at the Y-12 National Security Complex: A Case for Additional Experimental Benchmarks

Efforts are underway at the Y-12 National Security Complex (Y-12) to modernize the recovery, purification, and consolidation of un-irradiated, highly enriched uranium metal. Successful integration of advanced technology such as Electrorefining (ER) eliminates many of the intermediate chemistry systems and processes that are the current and historical basis of the nuclear fuel cycle at Y-12. The cost of operations, the inventory of hazardous chemicals, and the volume of waste are significantly reduced by ER. It also introduces unique material forms and compositions related to the chemistry of chloride salts for further consideration in safety analysis and engineering. The work herein briefly describes recent investigations of nuclear criticality for 235UO2Cl2 (uranyl chloride) and 6LiCl (lithium chloride) in aqueous solution. Of particular interest is the minimum critical mass of highly enriched uranium as a function of the molar ratio of 6Li to 235U. The work herein also briefly describes recent investigations of nuclear criticality for 235U metal reflected by salt mixtures of 6LiCl or 7LiCl (lithium chloride), KCl (potassium chloride), and 235UCl3 or 238UCl3 (uranium tri-chloride). Computational methods for analysis of nuclear criticality safety and published nuclear data are employed in the absence of directly relevant experimental criticality benchmarks.

36 MATERIALS SCIENCE↗

Summary: Verification of the ENDF/B-VII.1 and VIII.0 AMPX 1597-group Libraries for Advanced Reactor Analysis

The SCALE/AMPX multigroup (MG) cross section processing procedure has been updated to minimize reactivity differences for various advanced thermal and fast reactor designs, as observed for the current MG libraries, resulting in excellent agreement between the calculations with the new MG libraries and the continuous-energy reference calculations. The SCALE MG calculations are widely applied to thermal spectrum light-water reactor systems, as well as fast spectrum metallic systems. Due to growing interest from industry and regulators in applying SCALE for the design of fast spectrum reactors—both sodium and molten salt—it was desirable to review and improve the SCALE/AMPX procedure for unresolved resonance self-shielded data and high-energy neutron spectra. The data were improved by generating MG unresolved resonance data based on the analytic probability table method with the narrow resonance approximation and by using very fine and intermediate group structures that are typical for fast system analysis. This study focused on verifying the improved SCALE/AMPX MG cross section processing procedure and the new AMPX 1597-group library with the ENDF/B-VII.1 and VIII.0 evaluated nuclear data. The verification was made by performing reaction rate analysis and benchmark calculations for various thermal and fast reactor systems. Results indicate that the improved SCALE/AMPX MG cross section processing and libraries provide excellent results for advanced reactor analysis.

Kim, Kang Seog↗

Verification of the ENDF/B-VII.1 and VIII.0 AMPX 1597-Group Libraries for Advanced Reactor Analysis

The SCALE/AMPX multigroup (MG) cross section processing procedure has been updated to minimize reactivity differences for various advanced thermal and fast reactor designs, as observed for the current MG libraries, resulting in excellent agreement between the calculations with the new MG libraries and the continuous-energy reference calculations. The SCALE MG calculations are widely applied to thermal spectrum light-water reactor systems, as well as fast spectrum metallic systems. Due to growing interest from industry and regulators in applying SCALE for the design of fast spectrum reactors—both sodium and molten salt—it was desirable to review and improve the SCALE/AMPX procedure for unresolved resonance self-shielded data and high-energy neutron spectra. The data were improved by generating MG unresolved resonance data based on the analytic probability table method with the narrow resonance approximation and by using very fine and intermediate group structures that are typical for fast system analysis. This study focused on verifying the improved SCALE/AMPX MG cross section processing procedure and the new AMPX 1597-group library with the ENDF/B-VII.1 and VIII.0 evaluated nuclear data. The verification was made by performing reaction rate analysis and benchmark calculations for various thermal and fast reactor systems. Results indicate that the improved SCALE/AMPX MG cross section processing and libraries provide excellent results for advanced reactor analysis.

Kim, Kang Seog↗

Post irradiation experiment analysis using the APOLLO2 deterministic tool. Validation of JEFF-3.1.1 thermal and epithermal actinides neutron induced cross sections through MELUSINE experiments

Two different experiments performed in the 8 MWth MELUSINE experimental power pool reactor aimed at analyzing 1 GWd/t spent fuel pellets doped with several actinides. The goal was to measure the averaged neutron induced capture cross section in two very different neutron spectra (a PWR-like and an under-moderated one). This paper summarizes the combined deterministic APOLLO2-stochastic TRIPOLI4 analysis using the JEFF-3.1.1 European nuclear data library. A very good agreement is observed for most of neutron induced capture cross section of actinides and a clear underestimation for the {sup 241}Am(n,{gamma}) as an accurate validation of its associated isomeric ratio are emphasized. Finally, a possible huge resonant fluctuation (factor of 2.7 regarding to the 1=0 resonance total orbital momenta) is suggested for isomeric ratio. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development and validation of ALEPH2 Monte Carlo burn-up code

The ALEPH2 Monte Carlo depletion code has two principal features that make it a flexible and powerful tool for reactor analysis. First of all, its comprehensive nuclear data library ensures the consistency between steady-state Monte Carlo and deterministic depletion modules. It covers neutron and proton induced reactions, neutron and proton fission product yields, spontaneous fission product yields, radioactive decay data and total recoverable energies per fission. Secondly, ALEPH2 uses an advanced numerical solver for the first order ordinary differential equations describing the isotope balances, namely a Radau IIA implicit Runge-Kutta method. The versatility of the code allows using it for time behavior simulation of various systems ranging from single pin model to full-scale reactor model. The code is extensively used for the neutronics design of the MYRRHA research fast spectrum facility which will operate in both critical and sub-critical modes. The code has been validated on the decay heat data from JOYO experimental fast reactor. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

NDMAS Portal Updates

Overview of current ART-GCR Data, including fuel fabrication, irradiation monitoring, fuel and graphite, post-irradiation examination, graphite characterization, high temperature metals mechanical tests, methods validation data (including: HTTR, NSTF, and HTTF), addition of AGR fuel data, other GCR and related data, updated high temperature metals, ongoing and upcoming work, users guide, and the link to those interested in access to NDMAS.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

NDMAS

Overview of Current ART-GCR Data: Fuel Fabrication, Irradiation Monitoring (Fuel & Graphite – near real-time for HDG-1), Post-Irradiation Examination (Fuel & Graphite), Graphite Characterization (Baseline and Irradiated), High Temperature Metals Mechanical Tests, Design, Methods, and Validation Data, Japan Atomic Energy Agency’s High Temperature Test Reactor (HTTR), Argonne National Laboratory’s Natural convection Shutdown heat removal Test Facility (NSTF), Oregon State University’s High Temperature Test Facility (HTTF), Generation IV International VHTR Materials Handbook, Additional related data, and Advanced Test Reactor operations (near real-time).

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AMS / BARC Joint Survey Addendum Technical Report

This report details the data analysis results from data collected during the September-October 2019 joint survey series between the Department of Energy (DOE) National Nuclear Security Administration (NNSA) Aerial Measuring System (AMS) asset, and the Government of India’s Department of Atomic Energy (DAE) Bhabha Atomic Research Centre (BARC). This joint survey series took place at the Nevada National Security Site (NNSS), areas of public land in Southern Nevada, and at the DOE Office of Legacy Management (LM) Large Area Calibration Pads (LACP) at the Grand Junction Regional Airport in Grand Junction, CO. The data detailed in this report were gathered at the LACP. More details regarding the setup of these surveys and personnel involvement can be found in the AMS / BARC Joint Survey Summary Report. The data from the LACP collected by AMS are consistent with past data collection campaigns at the LACP. The AMS Bell 412 (B412) helicopter, equipped with both the standard AMS thallium-doped sodium iodide (NaI(Tl)) 2"x4"x16" 12-detector system and a subset of the BARC Aerial Gamma Spectroscopy System (AGSS) consisting of two independent 3"x3"cylindrical NaI(Tl) detectors, measured each of the five calibration pads for a minimum of 10 minutes. After the helicopter measurements, a pressurized ion chamber (PIC) was used to directly measure radiation exposure rates on each of the pads for a period 5 minutes. The geophysical calibration procedure published by the International Atomic Energy Agency (IAEA) (Erdi-Krausz et al. 2003) was used to determine the spectral stripping sensitivity matrix for naturally occurring radiological material (NORM). The sensitivity matrix is consistent with the AMS long term average. Additionally, the PIC data was used to calibrate the AMS system for exposure rate. The results of the exposure rate analysis are also consistent with AMS long-term averages.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-Content Clonogenic Survival Screen to Identify Chemoradiation Sensitizers

The combination of cytotoxic chemotherapy with radiation therapy (CRT) has resulted in significant improvements in clinical outcomes for patients with many locally advanced unresectable cancers. Only a small proportion of patients achieve pathologic complete responses to CRT; combination of CRT with targeted agents offers the promise of further improving treatment responses. However, numerous clinical trials have failed to show an improvement in clinical outcomes with the addition of targeted agents. To increase the accessibility of our screening method and accelerate the pace at which novel combinations with CRT are identified and incorporated into standard practices for treatments, we report details on screening method optimization, data generation, and downstream data analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preliminary analysis of the International Data Centre pipeline.

The International Data Centre of the Comprehensive Nuclear-Test-Ban Treaty Organization relies on automatic data processing as the first step in identifying seismic events from seismic waveform data. However, more than half of the automatically identified seismic events are eliminated by IDC analysts. Here, an IDC dataset is analyzed to determine if the number of automatically generated false positives could be reduced. Data that could be used to distinguish false positives from analyst-accepted seismic events includes the number of stations, the number of phases, the signal-to-noise ratio, and the pick error. An empirical method is devised to determine whether an automatically identified seismic event is acceptable, and the method is found to identify a significant number of the false positives in IDC data. This work could help reduce seismic analyst workload and could help improve the calibration of seismic monitoring stations. This work could also be extended to address identification of seismic events missed by automatic processing.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗