Search NASA⌕ Search

SEARCH · Search NASA

Results for “ORIFICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Subsonic wind-tunnel tests of a trailing-cone device for calibrating aircraft static pressure systems

A trailing-cone device for calibrating aircraft static-pressure systems was tested in a transonic wind tunnel to investigate the pressure-sensing characteristics of the device including effects of several configuration changes. The tests were conducted at Mach numbers from 0.30 to 0.95 with Reynolds numbers from (0.9 x one million to 4.1 x one million per foot). The results of these tests indicated that the pressures sensed by the device changed slightly but consistently as the distance between the device pressure orifices and cone was varied from 4 to 10 cone diameters. Differences between such device-indicated pressures and free-stream static pressure were small, however, and corresponded to Mach number differences of less than 0.001 for device configurations with pressure orifices located 5 or 6 cone diameters ahead of the cone. Differences between device-indicated and free-stream static pressures were not greatly influenced by a protection skid at the downstream end of the pressure tube of the device nor by a 2-to-1 change in test Reynolds number.

Jordan, F. L., Jr.↗

Space shuttle: An investigation of the load distribution over the SRB and external tank of a 0.004 scale model of the 049 space shuttle launch configuration

A study was conducted in a trisonic wind tunnel to determine the load distribution over the external tank and solid rocket boosters of the space shuttle launch configuration. The external tank was sting-supported and the solid rocket boosters and orbiter were mounted directly on the external tank. The external tank was, instrumented with 152 pressure orifices and the solid rocket boosters contained 78 orifices. The pressure data were obtained for various combinations of the three geometric components as the gap size between the external tank and the solid rocket boosters, angle of attack, and angle of sideslip were varied. Mach numbers ranged from 0.8 to 1.96.

Lott, R. A.↗

Externally pressurized gas-lubricated journal bearings with herringbone grooves - Load capacity and stability analysis.

A small eccentricity analysis was performed to predict load capacity and stability. Numerical results were obtained for a range of feeding parameter, pressure ratio, groove length and orifice recess volume for compressibility numbers from 0 to 50. These results were obtained from a digital computer program. Results showed that the addition of herringbone grooving to an externally pressurized bearing increases stability, but reduces load capacity at low compressibility numbers. A fully-grooved bearing is more stable than a partially-grooved bearing. Orifice recesses reduce stability, especially at high compressibility numbers.

Fleming, D. P.↗

Theory of a generalized Helmholtz resonator.

Based on the jet-flow model which is manifested in the nonlinearity of the orifice flow upon the passage of a high intensity wave, the theory of a generalized Helmholtz resonator has been developed. The results for some special devices, such as the conventional Helmholtz resonator and the quarter-wave tube, can be obtained through this general approach. The performance of the acoustic damper is characterized by a quantity known as the real part of the admittance coefficient. It is known that the conventional Helmholtz resonator has the lowest peak performance but the response is quite flat over a certain frequency range. On the other hand, a quarter-wave tube offers the largest peak in energy absorption with rather poor off-resonance behavior. Once the orifice length goes beyond the quarter-wave tube configuration, the performance of the so-called long damping device is even less attractive away from resonance.

Tang, P. K.↗

The diluter-demand oxygen system used during the international Himalayan expedition to Mount Everest.

The diluter-demand regulators are designed in such a way that as the individual inspires he simultaneously draws ambient air and pure oxygen from a tank into his mask. The size of the ambient air orifice is made directly proportional to the barometric pressure by use of a passive aneroid valve. As altitude increases the ambient air orifice is automatically made smaller and the individual inspires a greater proportion of oxygen.

Blume, F. D.↗

Lyophilized spore dispenser

A lyophilized spore dispenser is provided which produces a finely divided, monoparticulate cloud of bacterial spores. The spores are contained within a tightly sealed chamber, and a turbulator orifice connected to an air supply source provides a jet of air which stirs up the spores and causes the spores to be suspended in eddy currents within the chamber. This air jet also produces a positive pressure within the chamber which forces the spores out of an injection orifice.

Jessup, A. D.↗

Terminal-shock and restart control of a Mach 2.5, axisymmetric, mixed compression inlet with 40 percent internal contraction

Results of experimental tests conducted on a supersonic, mixed-compression, axisymmetric inlet are presented. The inlet is designed for operation at Mach 2.5 with a turbofan engine (TF-30). The inlet was coupled to either a choked orifice plate or a long duct which had a variable-area choked exit plug. Closed-loop frequency responses of selected diffuser static pressures used in the terminal-shock control system are presented. Results are shown for Mach 2.5 conditions with the inlet coupled to either the choked orifice plate or the long duct. Inlet unstart-restart traces are also presented. High-response inlet bypass doors were used to generate an internal disturbance and also to achieve terminal-shock control.

Baumbick, R. J.↗

Effect of cavitation on fluid stability in polymer thickened fluids and lubricants

The effects of cavitating flow on the polymeric additives used in functional fluids are described. A comparison of thermal and mechanical stability tests for these polymer solutions show distinct differences in the machanism of the polymer degradation. The thermal degradation tests appear to cause an unzippering or depolymerization type of reaction in which there is no particular selectivity based on molecular weight. The mechanical degradation of these fluids appears to be based on molecular weight. Measurements of molecular weight distributions during mechanical degradation show that for a given level of intensity only molecules above a certain minimum size are degraded. The effects of ultrasonic radiation on polymer degradation are reported. Tests were conducted to demonstrate the mechanism of mechanical polymer degradiation in an orifice. A more severe test than the orifice test in which two tapered roller bearings loaded against each other produce the mechanical breakdown is discussed.

Duda, J. L.↗

Nonlinear gas oscillations in pipes. II - Experiment

The problem of forced acoustic oscillations in a pipe was experimentally investigated, taking into account the response of both open and closed tubes to near-resonant excitation by large amplitude oscillations of a piston at one end of the tube. Attention was given to the effect of the orifice area on shock waves. By comparing the experimental results with nonlinear theory, wave reflection coefficients of the orifice plates were determined at both closed-tube and open-tube resonant frequencies. This approach can even be used when the terminating elements are subjected to intense periodic pressure pulses.

Sturtevant, B.↗

Exploratory wind tunnel tests of a shock-swallowing air data sensor at a Mach number of approximately 1.83

The test probe was designed to measure free-stream Mach number and could be incorporated into a conventional airspeed nose boom installation. Tests were conducted in the Langley 4-by 4-foot supersonic pressure tunnel with an approximate angle of attack test range of -5 deg to 15 deg and an approximate angle of sideslip test range of + or - 4 deg. The probe incorporated a variable exit area which permitted internal flow. The internal flow caused the bow shock to be swallowed. Mach number was determined with a small axially movable internal total pressure tube and a series of fixed internal static pressure orifices. Mach number error was at a minimum when the total pressure tube was close to the probe tip. For four of the five tips tested, the Mach number error derived by averaging two static pressures measured at horizontally opposed positions near the probe entrance were least sensitive to angle of attack changes. The same orifices were also used to derive parameters that gave indications of flow direction.

Nugent, J.↗

Characteristics of response factors of coaxial gaseous rocket injectors

The results of an experimental investigation undertaken to determine the frequency dependence of the response factors of various gaseous propellant rocket injectors subject to axial instabilities are presented. The injector response factors were determined, using the modified impedance-tube technique, under cold-flow conditions simulating those observed in unstable rocket motors. The tested injectors included a gaseous-fuel injector element, a gaseous-oxidizer injector element and a coaxial injector with both fuel and oxidizer elements. Emphasis was given to the determination of the dependence of the injector response factor upon the open-area ratio of the injector, the length of the injector orifice, and the pressure drop across the injector orifices. The measured data are shown to be in reasonable agreement with the corresponding injector response factor data predicted by the Feiler and Heidmann model.

Janardan, B. A.↗

Fluid manifold design for a solar energy storage tank

A design technique for a fluid manifold for use in a solar energy storage tank is given. This analytical treatment generalizes the fluid equations pertinent to manifold design, giving manifold pressures, velocities, and orifice pressure differentials in terms of appropriate fluid and manifold geometry parameters. Experimental results used to corroborate analytical predictions are presented. These data indicate that variations in discharge coefficients due to variations in orifices can cause deviations between analytical predictions and actual performance values.

Humphries, W. R.↗

Characterization of typical platelet injector flow configurations

A study to investigate the hydraulic atomization characteristics of several novel injector designs for use in liquid propellant rocket engines is presented. The injectors were manufactured from a series of thin stainless steel platelets through which orifices were very accurately formed by a photoetching process. These individual platelets were stacked together and the orifices aligned so as to produce flow passages of prescribed geometry. After alignment, the platelets were bonded into a single, 'platelet injector', unit by a diffusion bonding process. Because of the complex nature of the flow associated with platelet injectors, it was necessary to use experimental techniques, exclusively, throughout the study. Large scale models of the injectors were constructed from aluminum plates and the appropriate fluids were modeled using a glycerol-water solution. Stop-action photographs of test configurations, using spark-shadowgraph or stroboscopic back-lighting, are shown.

Hickox, C. E.↗

Influence of grazing flow on duct wall normal impedances

A theory is developed for evaluating the normal impedance of an orifice connecting a cylindrical cavity to a flow duct. The impedance of a piston velocity source at the orifice is calculated in terms of the cavity modes which are modified by the presence of a vortex flow. The strength of the vortex is related to the mean flow in the duct. Results are presented showing the variation of the normal impedance spectrum with the cavity vortex. The trends of these variations are confirmed by comparison with measurements.

Mungur, P.↗

Atmospheric cloud physics laboratory project study

Engineering studies were performed for the Zero-G Cloud Physics Experiment liquid cooling and air pressure control systems. A total of four concepts for the liquid cooling system was evaluated, two of which were found to closely approach the systems requirements. Thermal insulation requirements, system hardware, and control sensor locations were established. The reservoir sizes and initial temperatures were defined as well as system power requirements. In the study of the pressure control system, fluid analyses by the Atmospheric Cloud Physics Laboratory were performed to determine flow characteristics of various orifice sizes, vacuum pump adequacy, and control systems performance. System parameters predicted in these analyses as a function of time include the following for various orifice sizes: (1) chamber and vacuum pump mass flow rates, (2) the number of valve openings or closures, (3) the maximum cloud chamber pressure deviation from the allowable, and (4) cloud chamber and accumulator pressure.

Schultz, W. E.↗

Results of test IA137 in the NASA/ARC 14 foot transonic wind tunnel of the 0.07 scale external tank forebody (model 68-T) to determine auxiliary aerodynamic data system feasibility

Tests were conducted in a 14 foot transonic wind tunnel to examine the feasibility of the auxiliary aerodynamic data system (AADS) for determining angles of attack and sideslip during boost flight. The model used was a 0.07 scale replica of the external tank forebody consisting of the nose portion and a 60 inch (full scale) cylindrical section of the ogive cylinder tangency point. The model terminated in a blunt base with a 320.0 inch diameter at external tank (ET) station 1120.37. Pressure data were obtained from five pressure orifices (one total and four statics) on the nose probe, and sixteen surface static pressure orifices along the ET forebody.

Thornton, D. E.↗

Physical processes in hollow cathodes

Detailed measurements of magnetic field and floating potential inside large hollow cathodes in a quasi-steady MPD arc facility reveal a cavity plasma that is concentrated near the orifice for most operating conditions. However, for certain combinations of current and mass flow, the peak surface current density penetrates into the cavity up to one diameter upstream of the orifice. These measured distributions are consistent with a conduction model which suggests that maximum current penetration, and the more efficient cathode emission which accompanies it, occurs when the dominant mean free path for electron energy exchange is comparable to the cavity diameter.

Krishnan, M.↗

Lift enhancement by an externally trapped vortex

A theoretical study is made of the performance capabilities of a lift concept that utilizes a spanwise vortex over the upper surface of the wing. The vortex is generated by a vertical flap near the leading edge of the wing and maintained by suction through orifices in endplates at the wingtip. The analysis approximates the three-dimensional flow field with a two-dimensional configuration that is mapped by conformal transformation into the flow about a circle. Theoretical solutions for a range of flap and orifice configurations predict that section lift coefficients up to around 10 can be achieved. It is concluded that such a lift concept is applicable to STOL aircraft if the vortex can be adequately stabilized and if the endplate suction can be generated efficiently.

Rossow, V. J.↗