Search NASA⌕ Search

SEARCH · Search NASA

Results for “Occupancy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Re-evaluating Pleistocene–Holocene occupation of cave sites in north-west Thailand: new radiocarbon and luminescence dating

Established chronologies indicate a long-term ‘Hoabinhian’ hunter-gatherer occupation of Mainland Southeast Asia during the Terminal Pleistocene to Mid-Holocene (45 000–3000 years ago). Here, the authors re-examine the ‘Hoabinhian’ sequence from north-west Thailand using new radiocarbon and luminescence data from Spirit Cave, Steep Cliff Cave and Banyan Valley Cave. The results indicate that hunter-gatherers exploited this ecologically diverse region throughout the Terminal Pleistocene and the Pleistocene–Holocene transition, and into the period during which agricultural lifeways emerged in the Holocene. Hunter-gatherers did not abandon this highland region of Thailand during periods of environmental and socioeconomic change.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Effect of Silver Ion Occupancy on Hollandite Lattice Structure

The effect of tunnel cations on tunnel size in α-MnO 2 structured (hollandite, cryptomelane) materials has long been of interest, as the tunnel size effects catalytic and transport properties. Previous research on the tunnel size has focused on potassium cryptomelane (K x Mn 8 O 16 ). This paper uses synthetic control of silver content in Ag x Mn 8 O 16 to investigate the effect that tunnel silver occupancy has on the lattice parameters. Materials with silver (x) content between 1.14 and 1.66 were synthesized, synchrotron diffraction and Rietveld Refinement was used to determine lattice parameters. The lattice parameters were found to contract as silver content increases (from 9.774 Å to 9.738 Å), in contrast to previous investigations of other tunnel cations.

36 MATERIALS SCIENCE↗

Potential dose distributions at proposed surface radioactvity clearance levels resulting from occupational scenarios.

The purpose of this report is to evaluate the potential dose distribution resulting from surface radioactivity, using occupational radiation exposure scenarios. The surface radioactivity clearance values considered in this analysis may ultimately replace those currently specified in the U.S. Department of Energy (DOE) requirements and guidance for radiological protection of workers, the public and the environment. The surface contamination values apply to radioactive contamination deposited on a surface (i.e., not incorporated into the interior of the material). For these calculations, the dose coefficients for intake of radionuclides were taken from ICRP Publication 68 (ICRP 1994), and external exposure dose coefficients were taken from the compact disc (CD) that accompanied Federal Guidance Report (FGR) 13 (Eckerman et al. 1999). The ICRP Publication 68 dose coefficients were based on ICRP Publication 60 (ICRP 1990) and were used specifically for worker dose calculations. The calculated dose in this analysis is the 'effective dose' (ED), rather than the 'effective dose equivalent' (EDE).

07 ISOTOPE AND RADIATION SOURCES↗

Re-Assessing Green Building Performance: A Post Occupancy Evaluation of 22 GSA Buildings

2nd report on the performance of GSA's sustainably designed buildings. The purpose of this study was to provide an overview of measured whole building performance as it compares to GSA and industry baselines. The PNNL research team found the data analysis illuminated strengths and weaknesses of individual buildings as well as the portfolio of buildings. This section includes summary data, observations that cross multiple performance metrics, discussion of lessons learned from this research, and opportunities for future research. The summary of annual data for each of the performance metrics is provided in Table 25. The data represent 1 year of measurements and are not associated with any specific design features or strategies. Where available, multiple years of data were examined and there were minimal significant differences between the years. Individually focused post occupancy evaluation (POEs) would allow for more detailed analysis of the buildings. Examining building performance over multiple years could potentially offer a useful diagnostic tool for identifying building operations that are in need of operational changes. Investigating what the connection is between the building performance and the design intent would offer potential design guidance and possible insight into building operation strategies. The 'aggregate operating cost' metric used in this study represents the costs that were available for developing a comparative industry baseline for office buildings. The costs include water utilities, energy utilities, general maintenance, grounds maintenance, waste and recycling, and janitorial costs. Three of the buildings that cost more than the baseline in Figure 45 have higher maintenance costs than the baseline, and one has higher energy costs. Given the volume of data collected and analyzed for this study, the inevitable request is for a simple answer with respect to sustainably designed building performance. As previously stated, compiling the individual building values into single metrics is not statistically valid given the small number of buildings, but it has been done to provide a cursory view of this portfolio of sustainably designed buildings. For all metrics except recycling cost per rentable square foot and CBE survey response rate, the averaged building performance was better than the baseline for the GSA buildings in this study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DOE 2010 Occupational Radiation Exposure November 2011

This report discusses radiation protection and dose reporting requirements, presents the 2010 occupational radiation dose data trended over the past 5 years, and includes instructions to submit successful ALARA projects.

61 RADIATION PROTECTION AND DOSIMETRY↗

DOE 2011 Occupational Radiation Exposure Report

This report discusses radiation protection and dose reporting requirements, presents the 2011 occupational radiation dose data along with trends over the past 5 years, and provides instructions to submit successful as low as reasonably achievable (ALARA) projects.

61 RADIATION PROTECTION AND DOSIMETRY↗

Occupational Radiation Exposure at Commercial Nuclear Power Reactors and Other Facilities 2010

This report summarizes the occupational exposure data that are maintained in the U.S. Nuclear Regulatory Commission’s (NRC) Radiation Exposure Information and Reporting System (REIRS). The bulk of the information contained in the report was compiled from the 2010 annual reports submitted by five of the seven categories of NRC licensees subject to the reporting requirements of 10 CFR 20.2206. Because there are no geologic repositories for high-level waste currently licensed and no NRC-licensed low-level waste disposal facilities currently in operation, only five categories will be considered in this report. The annual reports submitted by these licensees consist of radiation exposure records for each monitored individual. These records are analyzed for trends and presented in this report in terms of collective dose and the distribution of dose among the monitored individuals.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Role of Occupant Behavior in Achieving Net Zero Energy: A Demonstration Project at Fort Carson

This study, sponsored by the U.S. General Services Administration’s Office of Federal High-Performance Green Buildings, aimed to understand the potential for institutional and behavioral change to enhance the performance of buildings, through a demonstration project with the Department of Defense in five green buildings on the Fort Carson, Colorado, Army base. To approach this study, the research team identified specific occupant behaviors that had the potential to save energy in each building, defined strategies that might effectively support behavior change, and implemented a coordinated set of actions during a three-month intervention.

Army↗

LLNL Radiation Protection Program (RPP) Rev 9.2, Implementation of 10 CFR 835, 'Occupational Radiation Protection'

The Department of Energy (DOE) originally issued Part 10 CFR 835, Occupational Radiation Protection, on January 1, 1994. This regulation, hereafter referred to as “the Rule”, required DOE contractors to develop and maintain a DOE-approved Radiation Protection Program (RPP); DOE approved the initial Lawrence Livermore National Laboratory (LLNL) RPP (Rev 2) on 6/29/95. DOE issued a revision to the Rule on December 4, 1998 and approved LLNL’s revised RPP (Rev 7.1) on 11/18/99. DOE issued a second Rule revision on June 8, 2007 (effective July 9, 2007) and on June 13, 2008 approved LLNL’s RPP (Rev 9.0) which contained plans and measures for coming into compliance with the 2007 Rule changes. DOE issued a correction to the Rule on April 21, 2009.

61 RADIATION PROTECTION AND DOSIMETRY↗

Improving the Success Rate of Delivering Annual Occupational Dosimetry Reports to Persons Issued Temporary External Dosimeters

Workers who are not routinely monitored for occupational radiation exposure at LANL may be issued temporary dosimeters in the field. Per 10CFR835 and DOE O 231.1A, the Laboratory's radiation protection program is responsible for reporting these results to the worker at the end of the year. To do so, the identity of the worker and their mailing address must be recorded by the delegated person at the time the dosimeter is issued. Historically, this data has not been consistently captured. A new online application was developed to record the issue of temporary dosimeters. The process flow of the application was structured such that: 1) the worker must be uniquely identified in the Lab's HR database, and 2) the mailing address of record is verified live time via a commercial web service, for the transaction to be completed. A COPQ savings (Type B1) of $96K/year is demonstrated for the new application.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Post-Occupancy Monitored Evaluation of the Dimmable Lighting, Automated Shading, and Underfloor Air Distribution System in The New York Times Building

With aggressive goals to reduce national energy use and carbon emissions, the U.S. Department of Energy (DOE) will be looking to exemplary buildings that have already invested in new approaches to achieving the energy performance goals now needed at a national level. The New York Times Building, in New York, New York, incorporates a number of innovative technologies, systems and processes and could become model for widespread replication in new and existing buildings. A year-long monitored study was conducted to verify energy performance, assess occupant comfort and satisfaction with the indoor environment, and evaluate impact on maintenance and operations. Lessons learned were derived from the analysis; these lessons could help identify and shape policy, financial, or supporting strategies to accelerate diffusion in the commercial building market.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Balancing energy conservation and occupant needs in ventilation rate standards for Big Box stores in California. Predicted indoor air quality and energy consumption using a matrix of ventilation scenarios (Final Report)

Through mass-balance modeling of various ventilation scenarios that might satisfy the ASHRAE 62.1 Indoor Air Quality (IAQ) Procedure, we estimate indoor concentrations of contaminants of concern (COCs) in California “big box” stores, compare estimates to available thresholds, and for selected scenarios estimate differences in energy consumption. Findings are intended to inform decisions on adding performance-based approaches to ventilation rate (VR) standards for commercial buildings. Using multi-zone mass-balance models and available contaminant source rates, we estimated concentrations of 34 COCs for multiple ventilation scenarios: VRmin (0.04 cfm/ft 2 ), VRmax (0.24 cfm/ft 2 ), and VRmid (0.14 cfm/ft 2 ). We compared COC concentrations with available health, olfactory, and irritant thresholds. We estimated building energy consumption at different VRs using a previously developed EnergyPlus model. VRmax did control all contaminants adequately, but VRmin did not, and VRmid did so only marginally. Air cleaning and local ventilation near strong sources both showed promise. Higher VRs increased indoor concentrations of outdoor air pollutants. Lowering VRs in big box stores in California from VRmax to VRmid would reduce total energy use by an estimated 6.6% and energy costs by 2.5%. Reducing the required VRs in California’s big box stores could reduce energy use and costs, but poses challenges for health and comfort of occupants. Source removal, air cleaning, and local ventilation may be needed at reduced VRs, and even at current recommended VRs. Also, alternative ventilation strategies taking climate and season into account in ventilation schedules may provide greater energy cost savings than constant ventilation rates, while improving IAQ.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

California Publicly-Owned Utilities (POUs) – LBNL ‘Beyond Widgets’ Project. Task: ambient lighting and occupancy-based plug load control. System Program Manual

This program manual contains detailed technical information for implementing an incentive program for task-ambient lighting and occupancy-based plug load control. This manual was developed by Lawrence Berkeley National Laboratory, in collaboration with the California Publicly-Owned Utilities (CA POUs) as a partner in the ‘Beyond Widgets’ program funded by the U.S. Department of Energy Building Technologies Office. The primary audience for this manual is the program staff of the various CA POUs. It may also be used by other utility incentive programs to help develop similar programs. It is anticipated that the content of this manual be utilized by the CA POU staff for developing related documents such as the Technical Resource Manual and other filings pertaining to the rollout of an energy systems-based rebate incentive program.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using Monte Carlo methods to estimate occupational dosage during 225 Ac production

Since alpha emitting isotopes such as 225 Ac, ideal for radiation treatment, are in short supply, the Medical Isotope Research and Production program at Brookhaven National Laboratory (BNL) is devel- oping new pathways for 225 Ac production. One proposed pathway is to resurrect the EBCO cyclotron at BNL to irradiate a 226 Ra target for 40 hours in a 16 MeV proton beam. Using MCNPX and CINDER software to simulate this process, we found that 1.26 Ci of 225 Ac could be produced from 300 mg of 226 Ra. To ensure workplace safety, we modeled the detailed geometry of lab 2-66C in Bldg. 801 and performed Monte Carlo simulations to estimate the radiation outside the lab as the irradiated sample is processed in a hot cell. We found the maximum dose outside the lab to be about 9 x 10 -5 rem/h. To reduce occupational dose, we recommend 200 thick steel shielding covering the sample insertion passage. These 225 Ac production runs could help cover the EBCO cyclotron's operational costs.

43 PARTICLE ACCELERATORS↗

DOE 2008 Occupational Radiation Exposure October 2009

A major priority of the U.S. Department of Energy (DOE) is to ensure the health, safety, and security of DOE employees, contractors, and subcontractors. The Office of Health, Safety and Security (HSS) provides the corporate-level leadership and strategic vision necessary to better coordinate and integrate health, safety, environment, security, enforcement, and independent oversight programs. One function that supports this mission is the DOE Corporate Operating Experience Program that provides collection, analysis, and dissemination of performance indicators, such as occupational radiation exposure information. This analysis supports corporate decision-making and synthesizes operational information to support continuous environment, safety, and health improvement across the DOE complex.

61 RADIATION PROTECTION AND DOSIMETRY↗

One Galaxy Sample to Rule Them All: Halo Occupation Distribution Modeling of DES Year 3 Source Galaxies

Abstract For the joint analysis of second-order weak-lensing and galaxy clustering statistics, so-called 3 × 2 analyses, the selection and characterization of optimal galaxy samples is a major area of research. One promising choice is to use the same galaxy sample as lenses and sources, which reduces the systematics parameter space that describes the uncertainties related to galaxy samples. Such a “lens-equal-source” analysis significantly improves the self-calibration of photo- z systematics, leading to improved cosmological constraints. With the aim of enabling a lens-equal-source analysis on small scales, we investigate the halo–galaxy connection of DES Year 3 source galaxies. We develop a technique to construct mock source galaxy populations by matching COSMOS/UltraVISTA photometry to U niverse M achine galaxies. These mocks predict a source halo occupation distribution (HOD) that exhibits significant redshift evolution, nontrivial central incompleteness, and galaxy assembly bias. We produce multiple realizations of mock source galaxies drawn from the U niverse M achine posterior, with added uncertainties in the measured Dark Energy Survey photometry and galaxy shapes. We fit a modified HOD formalism to these realizations to produce priors on the galaxy–halo connection for cosmological analyses. We additionally train an emulator that predicts this HOD to ∼2% accuracy from redshift z = 0.1−1.3 that models the dependence of this HOD on (1) observational uncertainties in galaxy size and photometry and (2) uncertainties in the U niverse M achine predictions.

Salcedo, Andrés N. (ORCID:000000031420527X)↗