Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operating Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

What Is the Value of Alternative Methods for Estimating Ramping Needs?

Power system operators procure and deploy flexibility reserves or ramping products to address balancing needs caused by uncertainty and variability of load and generation. Existing methods estimate ramping needs using calendar information and historical forecast errors. Novel methods investigate if real-time weather information could inform ramping and other balancing requirements. This paper compares estimation methods for ramping requirements in theory and practice. The theoretical framework indicates when an alternative method could yield improved economic or reliability performance than existing methods by requiring lower or higher levels of ramping products. Preliminary simulations on a 118-bus test system for 4 days in May 2019 illustrate how system performance improves or deteriorates when ramping requirements are weather-informed (alternative) instead of calendar-based (baseline). Preliminary results suggest high variability in change of performance and underline the impact of additional factors, such as system conditions, on the realized performance change.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Peer-to-Peer Energy Trading under Network Constraints Based on Generalized Fast Dual Ascent

We report the wide deployment of renewable energy resources, combined with a more proactive demand-side management, is inducing a new paradigm in both power system operation and electricity market trading, which especially boosts the emergence of the peer-to-peer (P2P) market. A more flexible local market mechanism is highly desirable in response to fast changes in renewable power generation at the distribution network level. Moreover, large-scale implementation of P2P energy trading inevitably affects the secure and economic operation of the distribution network. This paper presents a new P2P electricity trading framework with distribution network security constraints considered using the generalized fast dual ascent method. First, an event-driven local P2P market framework is presented to facilitate short-term or immediate local energy transactions. Then, the sensitivity analysis of nodal voltage and network loss with respect to nodal power injections is used to evaluate the impacts of P2P transactions on the distribution network, which ensures the secure operation of the distribution system. Thereby, the external operational constraints are internalized, and the cost of P2P energy trading can be appropriately allocated in an endogenous way. Moreover, a generalized fast dual ascent method is employed to implement distributed market-clearing efficiently. Finally, numerical results indicate that the proposed model could guarantee secure operation of the distribution system with P2P energy trading, and the solution method enjoys good convergence performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Intermittent Renewable Management Pilot Phase 2

The Intermittent Renewable Management Pilot - Phase 2 (IRM2) was designed to study the feasibility of demand-side resources to participate into the California Independent System Operator (CAISO) wholesale market as proxy demand resources (PDR). The pilot study focused on understanding the issues related with direct participation of third-parties and customers including customer acceptance; market transformation challenges (wholesale market, technology); technical and operational feasibility; and value to the rate payers, DR resource owners and the utility on providing an enabling mechanism for DR resources into the wholesale markets. The customer had the option of committing to either three contiguous hour blocks for 24 days or six contiguous hours for 12 days a month with day-ahead notification that aligned with the CAISO integrated forward market. As a result of their being available, the customer was paid $10/ kilowatt (kW)-month for capacity in addition to CAISO energy settlements. The participants were limited to no more than a 2 megawatt (MW) capacity with a six-month commitment. Four participants successfully engaged in the pilot. In this report, we provide the description of the pilot, participant performance results, costs and value to participants as well as outline some of the issues encountered through the pilot. Results show that participants chose to participate with storage and the value of CAISO settlements were significantly lower than the capacity payments provided by the utility as incentive payments. In addition, this pilot revealed issues both on the participant side and system operations side. These issues are summarized in the report.The Intermittent Renewable Management Pilot - Phase 2 (IRM2) was designed to study the feasibility of demand-side resources to participate into the California Independent System Operator (CAISO) wholesale market as proxy demand resources (PDR). The pilot study focused on understanding the issues related with direct participation of third-parties and customers including customer acceptance; market transformation challenges (wholesale market, technology); technical and operational feasibility; and value to the rate payers, DR resource owners and the utility on providing an enabling mechanism for DR resources into the wholesale markets.

99 GENERAL AND MISCELLANEOUS↗

Fish Friendly Water Rules' Impact On the Power Grid with High VRE Levels

Columbia River basin multipurpose reservoirs are operated for hydropower production and many other purposes considering the aquatic habitat of the river basin. Specifically, the river basin fish population is a vital element for the tribal community of the river basin. When conventional thermal power plants are retired, hydropower flexibility balances the wind and solar variability of the power grid and provides grid services to maximize the high renewable power absorption. On the other hand, over-reliance on hydropower could harm the river basin fish habitat. For example, water release pulses during peak electricity demand hours and shorter-term water release variation could harm the fish population. Power grid planners, environmentalists, Columbia Basin tribes, hydro regulators, and water resource planners work together to understand the impacts of Columbia River basin operation in a fish-friendly way in the current power grid and power grid with higher renewable power share. We examine different levels of renewable share in the Western Interconnection to understand the multiple weather years and future climate projection and operating scenario impact on the power grid and water system. We measure power grid impacts for various water resources planning scenarios in terms of total system operating cost, system reliability indicators, changes in wind and solar generation and curtailments, local marginal prices, and revenue for hydropower producers. The study results inform reservoir operating rules decisions from hydropower power producers, system operators, other water users, tribes, environmentalists, and other stakeholders.

environmental↗

Stochastic Continuous-time Flexibility Scheduling and Pricing in Wholesale Electricity Markets

Large-scale integration of intermittent renewable energy sources (RES) is calling for additional flexibility resources as well as more advanced modeling and optimization techniques to account for the increasing uncertainty and variability in power systems operation. As the RES integration gains momentum, the magnitude and frequency of their variations increase, which may trigger ramping scarcity events in real-time power systems operation. This necessitates revisiting the present definition of power systems flexibility and reserve services to reflect their robustness and adequacy towards sub-interval variations of the load and RES, as well as adjusting the operation models to accommodate the new reserve services. This project took a fundamental approach and aimed at developing continuous-time scheduling and pricing model that accurately models the continuous-time variations of load and RES and efficiently deploys the ramping capability of flexible resources to compensate the sources of variability and uncertainty in the market. In this regard, this project pursued the following goals: Developing stochastic multi-fidelity continuous-time optimization models for scheduling of energy storage (ES) systems and flexible loads in wholesale energy markets; Developing the theory and practices of continuous-time locational marginal pricing for valuating energy storage systems and flexible loads in wholesale energy markets; Developing function space solution approach to convert the proposed stochastic multi-fidelity continuous-time optimization models into tractable mixed-integer linear optimization models; and Defining flexibility reserve as a new type of reserve in markets that would enable ultimate participation of energy storage devices in provision of services to compensate the variability and uncertainty of RES in electricity markets. This project successfully completed all five major tasks defined in the SOPO, and produced 8 high-impact journal papers, 6 conference papers, 3 published U.S. patents, and one web-based software for continuous-time operation optimization of power systems. The application of the proposed flexibility reserve and the stochastic multi-fidelity continuous-time operation scheduling models would modify the forward commitment and schedule of generating units, ES devices and flexible loads, and would line up the resources in such a way that the composition of available resources is better prepared to respond to the sub-hourly variations of the load and renewable resources in real-time operation. Therefore, this project paves the way to sustainable, reliable, and economic integration of renewable energy resources in power system, supporting the progress towards reaching the national targets on energy independence. Even if the proposed models offers a radically different point of view as compared to existing models, it does not alter fundamentally the architecture of power systems operations, nor the complexity of the scheduling problem, so the integration of this project in power systems is extremely practical.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TOSS STIG

LLNL HPC systems run a custom version of RedHat's RHEL operating system known as TOSS. In 2022, after working with DISA, Livermore Computing staff completed the STIG (Security Technical Implementation Guide) for the TOSS 4 operating system. This software project contains the source code associated with that STIG and implements checks and remediations for configuring a system in compliance with that STIG.

Lee, Ian↗

Cybersecurity and Digital Components: Supply Chain Deep Dive Assessment

The report “America’s Strategy to Secure the Supply Chain for a Robust Clean Energy Transition” lays out the challenges and opportunities faced by the United States in the energy supply chain as well as the federal government plans to address these challenges and opportunities. It is accompanied by several issue-specific deep dive assessments, including this one, in response to Executive Order 14017 “America’s Supply Chains,” which directs the Secretary of Energy to submit a report on supply chains for the energy sector industrial base. The Executive Order is helping the federal government to build more secure and diverse U.S. supply chains, including energy supply chains. As the energy sector has become more globalized and increasingly complex, digitized, and even virtualized, its supply chain risk for digital components – the software, virtual platforms and services, and data – in energy systems has evolved and expanded. All digital components in U.S. energy sector systems are vulnerable and may be subject to cyber supply cha in risks stemming from a variety of threats, vulnerabilities, and impacts. This includes digital components in all systems within the ESIB, namely those systems operated by asset owners across different energy subsectors (e.g., electricity, oil and natural gas, and renewables) and the systems operated by a worldwide industrial complex with capabilities to perform research and development and design, produce, operate, and maintain energy sector systems, subsystems, components, or parts to meet U.S. energy requirements. Supply chain risks for digital components including software, virtual platforms and services, and data have grown in recent years as increasingly sophisticated cyber adversaries have targeted exploiting vulnerabilities in these digital assets. Supply chain risks for digital components in energy sector systems will continue to evolve and likely increase as these systems are increasingly interconnected, digitized, and remotely operated.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

System Architecture Directions for Post-SoC/32-bit Networked Sensors

The emergence of low-power 32-bit Systems-on-Chip (SoCs), which integrate a 32-bit MCU, radio, and flash, presents an opportunity to re-examine design points and trade-offs at all levels of the system architecture of networked sensors. To this end, we develop a post-SoC/32-bit design point called Hamilton, showing that using integrated components enables a ~$7 core and shifts hardware modularity to design time. We study the interaction between hardware and embedded operating systems, identifying that (1) post-SoC motes provide lower idle current (5.9 μA) than traditional 16-bit motes, (2) 32-bit MCUs are a major energy consumer (e.g., tick increases idle current >50 times), comparable to radios, and (3) thread-based concurrency is viable, requiring only 8.3 μs of context switch time. We design a system architecture, based on a tickless multithreading operating system, with cooperative/adaptive clocking, advanced sensor abstraction, and preemptive packet processing. Its efficient MCU control improves concurrency with ~30% less energy consumption. Together, these developments set the system architecture for networked sensors in a new direction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of autonomous gamma dose logger for environmental monitoring

Continuous monitoring and archiving of background radiation levels in and around the nuclear installation is essential and the data would be of immense use during analysis of any untoward incidents. A portable Geiger Muller detector based autonomous gamma dose logger (AGDL) for environmental monitoring is indigenously designed and developed. The system operations are controlled by microcontroller (AT89S52) and the main features of the system are software data acquisition, real time LCD display of radiation level, data archiving at removable compact flash card. The complete system operates on 12 V battery backed up by solar panel and hence the system is totally portable and ideal for field use. The system has been calibrated with Co-60 source (8.1 MBq) at various source-detector distances. The system is field tested and performance evaluation is carried out. This paper covers the design considerations of the hardware, software architecture of the system along with details of the front-end operation of the autonomous gamma dose logger and the data file formats. The data gathered during field testing and inter comparison with GammaTRACER are also presented in the paper. AGDL has shown excellent correlation with energy fluence monitor tuned to identify {sup 41}Ar, proving its utility for real-time plume tracking and source term estimation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Review of Machine Learning Applications in Power System Resilience

The integration of power electronics enabled devices and the high penetration of renewable energy drastically increase the complexity of power system operation and control. Power systems are still vulnerable to large-scale blackouts caused by extreme natural events or man-made attacks. With the recent development in artificial intelligence technique, machine learning has shown a processing ability in computational, perceptual and cognitive intelligence. It is an urgent challenge to integrate the advanced machine learning technology and large amount of real-time data from wide area measurement systems and intelligent electronic devices, in order to effectively enhance power system resilience and ensure the reliable and secure operation of power systems. Therefore, this paper aims to systematically review the existing application of machine learning methods on power system resilience enhancement, to expand the interest of researchers and scholars in this topic, and to jointly promote the application of artificial intelligence in the field of power systems.

Deep Learning↗

Electric Grid Expansion Planning with High Levels of Variable Generation

Renewables are taking a large proportion of generation capacity in U.S. power grids. As their randomness has increasing influence on power system operation, it is necessary to consider their impact on system expansion planning. To this end, this project studies the generation and transmission expansion co-optimization problem of the US Eastern Interconnection (EI) power grid with a high wind power penetration rate. In this project, the generation and transmission expansion problem for the EI system is modeled as a mixed-integer programming (MIP) problem. This study analyzed a time series creation method to capture the diversity of load and wind power across balancing regions in the EI system. The obtained time series can be easily introduced into the MIP co-optimization problem and then solved robustly through available MIP solvers. Simulation results show that the proposed time series generation method and the expansion co-optimization model and can improve the expansion result significantly after considering the diversity of wind and load across EI regions. The improved expansion plan that combines generation and transmission will aid system planners and policy makers to maximize the social welfare. This study shows that modelling load and wind variations and diversities across balancing regions will produce significantly different expansion result compared with former studies. For example, if wind is modeled in more details (by increasing the number of wind output levels) so that more wind blocks are considered in expansion planning, transmission expansion will be larger and the expansion timing will be earlier. Regarding generation expansion, more wind scenarios will slightly reduce wind generation expansion in the EI system and increase the expansion of other generation such as gas. Also, adopting detailed wind scenarios will reveal that it may be uneconomic to expand transmission networks for transmitting a large amount of wind power through a long distance in the EI system. Incorporating more details of renewables in expansion planning will inevitably increase the computational burden. Therefore, high performance computing (HPC) techniques are urgently needed for power system operation and planning optimization. As a scoping study task, this project tested some preliminary parallel computation techniques such as breaking down the simulation task into several sub-tasks based on chronology splitting or sample splitting, and then assigning these sub-tasks to different cores. Testing results show significant time reduction when a simulation task is split into several sub-tasks for parallel execution.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Field Programmable Gate Array-Based Reactor Protection Systems and Potential for Inclusion of Secure Elements to Improve Cybersecurity

For acceptable implementations of technologies like wireless communications, remote monitoring, etc., strong mitigations must be developed and evaluated to ensure that new attack pathways do not increase risk for Advanced Reactors. Secure Elements can be adopted and adapted for this purpose based on tamper resistance and cryptographic abilities, but research must be done to properly integrate into critical components such as FPGA-based Important to Safety systems in conjunction with current and future regulations on cyber security features in Advanced Reactors. Typically, the integration of a Secure Element happens during the POST and UEFI boot of a computing platform, performed by the Operating System, which is not possible with FPGAs because they do not include these firmware components. Work must be done to identify a reliable and secure method for integration in FPGA-based systems which lack Operating Systems and therefore complex boot procedures, system calls, etc.

97 MATHEMATICS AND COMPUTING↗

Field Programmable Gate Array-Based Reactor Protection Systems and Potential for Inclusion of Secure Elements to Improve Cybersecurity

For acceptable implementations of technologies like wireless communications, remote monitoring, etc., strong mitigations must be developed and evaluated to ensure that new attack pathways do not increase risk for Advanced Reactors. Secure Elements can be adopted and adapted for this purpose based on tamper resistance and cryptographic abilities, but research must be done to properly integrate into critical components such as FPGA-based Important to Safety systems in conjunction with current and future regulations on cyber security features in Advanced Reactors. Typically, the integration of a Secure Element happens during the POST and UEFI boot of a computing platform, performed by the Operating System, which is not possible with FPGAs because they do not include these firmware components. Work must be done to identify a reliable and secure method for integration in FPGA-based systems which lack Operating Systems and therefore complex boot procedures, system calls, etc.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Dual wavelength laser damage testing for high energy lasers.

As high energy laser systems evolve towards higher energies, fundamental material properties such as the laser-induced damage threshold (LIDT) of the optics limit the overall system performance. The Z-Backlighter Laser Facility at Sandia National Laboratories uses a pair of such kiljoule-class Nd:Phosphate Glass lasers for x-ray radiography of high energy density physics events on the Z-Accelerator. These two systems, the Z-Beamlet system operating at 527nm/ 1ns and the Z-Petawatt system operating at 1054nm/ 0.5ps, can be combined for some experimental applications. In these scenarios, dichroic beam combining optics and subsequent dual wavelength high reflectors will see a high fluence from combined simultaneous laser exposure and may even see lingering effects when used for pump-probe configurations. Only recently have researchers begun to explore such concerns, looking at individual and simultaneous exposures of optics to 1064 and third harmonic 355nm light from Nd:YAG [1]. However, to our knowledge, measurements of simultaneous and delayed dual wavelength damage thresholds on such optics have not been performed for exposure to 1054nm and its second harmonic light, especially when the pulses are of disparate pulse duration. The Z-Backlighter Facility has an instrumented damage tester setup to examine the issues of laser-induced damage thresholds in a variety of such situations [2] . Using this damage tester, we have measured the LIDT of dual wavelength high reflectors at 1054nm/0.5ps and 532nm/7ns, separately and spatially combined, both co-temporal and delayed, with single and multiple exposures. We found that the LIDT of the sample at 1054nm/0.5ps can be significantly lowered, from 1.32J/cm{sup 2} damage fluence with 1054/0.5ps only to 1.05 J/cm{sup 2} with the simultaneous presence of 532nm/7ns laser light at a fluence of 8.1 J/cm{sup 2}. This reduction of LIDT of the sample at 1054nm/0.5ps continues as the fluence of 532nm/7ns laser light simultaneously present increases. The reduction of LIDT does not occur when the 2 pulses are temporally separated. This paper will also present dual wavelength LIDT results of commercial dichroic beam-combining optics simultaneously exposed with laser light at 1054nm/2.5ns and 532nm/7ns.

43 PARTICLE ACCELERATORS↗

Petascale system management experiences.

Petascale High-Performance Computing (HPC) systems are among the largest systems in the world. Intrepid, one such system, is a 40,000 node, 556 teraflop Blue Gene/P system that has been deployed at Argonne National Laboratory. In this paper, we provide some background about the system and our administration experiences. In particular, due to the scale of the system, we have faced a variety of issues, some surprising to us, that are not common in the commodity world. We discuss our expectations, these issues, and approaches we have used to address them. HPC systems are a bellwether for computing systems at large, in multiple regards. HPC users are motivated by the need for absolute performance; this results in two important pushes. HPC users are frequently early adopters of new technologies and techniques. Successful technologies, like Infiniband, prove their value in HPC before gaining wider adoption. Unfortunately, this early adoption alone is not sufficient to achieve the levels of performance required by HPC users; parallelism must also be harnessed. Over the last 15 years, beowulf clustering has provided amazing accessibility to non-HPC-savvy and even non-technical audiences. During this time, substantial adoption of clustering has occurred in many market segments unrelated to computational science. A simple trend has emerged: the scale and performance of high-end HPC systems are uncommon at first, but become commonplace over the course of 3-5 years. For example, in early 2003, several systems on the Top500 list consisted of either 1024 nodes or 4096-8192 cores. In 2008, such systems are commonplace. The most recent generation of high-end HPC systems, so called petascale systems, are the culmination of years of research and development in research and academia. Three such systems have been deployed thus far. In addition to the 556 TF Intrepid system at Argonne National Laboratory, a 596 TF Blue Gene/L-based system has been deployed at Lawrence Livermore National Laboratory, and a 504 TF Opteron-based system has been deployed at Texas Advanced Computing Center (TACC). Intrepid is comprised of 40,960 nodes with a total of 163,840 cores. While systems like these are uncommon now, we expect them to become more widespread in the coming years. The scale of these large systems impose several requirements upon system architecture. The need for scalability is obvious, however, power efficiency and density constraints have become increasingly important in recent years. At the same time, because the size of administrative staff cannot grow linearly with the system size, more efficient system management techniques are needed. In this paper we will describe our experiences administering Intrepid. Over the last year, we have experienced a number of interesting challenges in this endeavor. Our initial expectation was for scalability to be the dominant system issue. This expectation was not accurate. Several issues expected to have minor impact have played a much greater role in system operations. Debugging, due to the large numbers of components used in scalable system operations, has become a much more difficult endeavor. The system has a sophisticated monitoring system, however, the analysis of this data has been problematic. These issues are not specific to HPC workloads in any way, so we expect them to be of general interest. This paper consists of three major parts. First, we will provide a detailed overview of several important aspects of Intrepid's hardware and software. In this, we will highlight aspects that have featured prominently in our system management experiences. Next, we will describe our administration experiences in detail. Finally, we will draw some conclusions based on these experiences. In particular, we will discuss the implications for the non-HPC world, system managers, and system software developers.

99 GENERAL AND MISCELLANEOUS↗

Development of an Integrated Residential Heating, Ventilation, Cooling, and Dehumidification System for Residences

The Need and the Opportunity Codes such as ASHRAE 90.2 and IECC, and programs such as Energy Star and Builders Challenge, are causing new homes to be built to higher performance standards. As a result sensible cooling loads in new homes are going down, but indoor air quality prerogatives are causing ventilation rates and moisture loads to increase in humid climates. Conventional air conditioners are unable to provide the low sensible heat ratios that are needed to efficiently cool and dehumidify homes since dehumidification potential is strongly correlated with cooling system operating hours. The project team saw an opportunity to develop a system that is at least as effective as a conventional air conditioner plus dehumidifier, removes moisture without increasing the sensible load, reduces equipment cost by integrating components, and simplifies installation. Project Overview Prime contractor Davis Energy Group led a team in developing an Integrated Heating, Ventilation, Cooling, and Dehumidification (I-HVCD) system under the DOE SBIR program. Phase I and II SBIR project activities ran from July 2003 through December 2007. Tasks included: (1) Mechanical Design and Prototyping; (2) Controls Development; (3) Laboratory and Field Testing; and (4) Commercialization Activities Technology Description. Key components of the prototype I-HVCD system include an evaporator coil assembly, return and outdoor air damper, and controls. These are used in conjunction with conventional components that include a variable speed air handler or furnace, and a two-stage condensing unit. I-HVCD controls enable the system to operate in three distinct cooling modes to respond to indoor temperature and relative humidity (RH) levels. When sensible cooling loads are high, the system operates similar to a conventional system but varies supply airflow in response to indoor RH. In the second mode airflow is further reduced, and the reheat coil adds heat to the supply air. In the third mode, the reheat coil adds additional heat to maintain the supply air temperature close to the return air temperature (100% latent cooling). Project Outcomes Key Phase II objectives were to develop a pre-production version of the system and to demonstrate its performance in an actual house. The system was first tested in the laboratory and subsequently underwent field-testing at a new house in Gainesville, Florida. Field testing began in 2006 with monitoring of a 'conventional best practices' system that included a two stage air conditioner and Energy Star dehumidifier. In September 2007, the I-HVCD components were installed for testing. Both systems maintained uniform indoor temperatures, but indoor RH control was considerably better with the I-HVCD system. The daily variation from average indoor humidity conditions was less than 2% for the I-HVCD vs. 5-7% for the base case system. Data showed that the energy use of the two systems was comparable. Preliminary installed cost estimates suggest that production costs for the current I-HVCD integrated design would likely be lower than for competing systems that include a high efficiency air conditioner, dehumidifier, and fresh air ventilation system. Project Benefits This project verified that the I-HVCD refrigeration compacts are compact (for easy installation and retrofit) and can be installed with air conditioning equipment from a variety of manufacturers. Project results confirmed that the system can provide precise indoor temperature and RH control under a variety of climate conditions. The I-HVCD integrated approach offers numerous benefits including integrated control, easier installation, and reduced equipment maintenance needs. Work completed under this project represents a significant step towards product commercialization. Improved indoor RH control and fresh air ventilation are system attributes that will become increasingly important in the years ahead as building envelopes improve and sensible cooling loads continue to fall. Technologies like I-HVCD will be instrumental in meeting goals set by Building America and other programs to reduce energy use while improving the indoor environment. Next Steps The following steps are needed to bring the product to commercialization: (1) Value engineering to reduce costs; (2) Addition of zoning capability to improve marketability; (3) Fabrication and testing of additional prototypes; and (4) Identification of a manufacturer. Initial efforts to interest large air conditioner manufacturers has shown some interest, but the preferred path to market may be to employ a boutique manufacturer that markets to HVAC contractors. Distribution of the results of this work will improve opportunities for attracting manufacturers. Additional funding is needed to prepare the product for this final step.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗