Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optimized electrodes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Balancing surface adsorption and diffusion of lithium-polysulfides on nonconductive oxides for lithium–sulfur battery design

Lithium–sulfur batteries have attracted attention due to their six-fold specific energy compared with conventional lithium-ion batteries. Dissolution of lithium polysulfides, volume expansion of sulfur and uncontrollable deposition of lithium sulfide are three of the main challenges for this technology. State-of-the-art sulfur cathodes based on metal-oxide nanostructures can suppress the shuttle-effect and enable controlled lithium sulfide deposition. However, a clear mechanistic understanding and corresponding selection criteria for the oxides are still lacking. Herein, various nonconductive metal-oxide nanoparticle-decorated carbon flakes are synthesized via a facile biotemplating method. The cathodes based on magnesium oxide, cerium oxide and lanthanum oxide show enhanced cycling performance. Adsorption experiments and theoretical calculations reveal that polysulfide capture by the oxides is via monolayered chemisorption. Moreover, we show that better surface diffusion leads to higher deposition efficiency of sulfide species on electrodes. Lastly, oxide selection is proposed to balance optimization between sulfide-adsorption and diffusion on the oxides.

25 ENERGY STORAGE↗

Enhancing Graphene Capacitance by Nitrogen: Effects of Doping Configuration and Concentration

Recent experiments have shown that nitrogen doping enhances capacitance in carbon electrode supercapacitors. However, a detailed study of the effect of N-doping on capacitance is still lacking. In this paper, we study the doping concentration and the configuration effect on the electric double-layer (EDL) capacitance, quantum capacitance, and total capacitance. It is found that pyridinic and graphitic nitrogens can increase the total capacitance by increasing quantum capacitance, but pyrrolic configuration limits the total capacitance due to its much lower quantum capacitance than the other two configurations. We also find that, unlike the graphitic and pyridinic nitrogens, the pyrrolic configuration's quantum capacitance does not depend on the nitrogen concentration, which may explain why some capacitance versus voltage measurements of N-doped graphene exhibit a V-shaped curve similar to that of undoped graphene. Our investigation provides a deeper understanding of the capacitance enhancement of the N-doping effect in carbon electrodes and suggests a potentially effective way to optimize the capacitance by controlling the type of N-doping.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of the insulator barrier and the superconducting transition temperature in GdBa{sub 2}Cu{sub 3}O{sub 7−δ}/BaTiO{sub 3} bilayers for application in tunnel junctions

The optimization of the superconducting properties in a bottom electrode and the quality of an insulator barrier are the first steps in the development of superconductor/insulator/superconductor tunnel junctions. Here, we study the quality of a BaTiO{sub 3} tunnel barrier deposited on a 16 nm thick GdBa{sub 2}Cu{sub 3}O{sub 7−δ} thin film by using conductive atomic force microscopy. We find that the tunnel current is systematically reduced (for equal applied voltage) by increasing the BaTiO{sub 3} barrier thickness between 1.6 and 4 nm. The BaTiO{sub 3} layers present an energy barrier of ≈1.2 eV and an attenuation length of 0.35–0.5 nm (depending on the applied voltage). The GdBa{sub 2}Cu{sub 3}O{sub 7−δ} electrode is totally covered by a BaTiO{sub 3} thickness above 3 nm. The presence of ferroelectricity was verified by piezoresponse force microscopy for a 4 nm thick BaTiO{sub 3} top layer. The superconducting transition temperature of the bilayers is systematically suppressed by increasing the BaTiO{sub 3} thickness. This fact can be associated with stress at the interface and a reduction of the orthorhombicity of the GdBa{sub 2}Cu{sub 3}O{sub 7−δ}. The reduction in the orthorhombicity is expected by considering the interface mismatch and it can also be affected by reduced oxygen stoichiometry (poor oxygen diffusion across the BaTiO{sub 3} barrier)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The digital mirror Langmuir probe: Field programmable gate array implementation of real-time Langmuir probe biasing

High bandwidth, high spatial resolution measurements of electron temperature, density, and plasma potential are valuable for resolving turbulence in the boundary plasma of tokamaks. While conventional Langmuir probes can provide such measurements, either their temporal or spatial resolution is limited: the former by the sweep rate necessary for obtaining I-V characteristics and the latter by the need to use multiple electrodes, as is the case in triple and double probe configurations. The Mirror Langmuir Probe (MLP) bias technique overcomes these limitations by rapidly switching the voltage on a single electrode cycling between three bias states, each dynamically optimized for the local plasma conditions. The MLP system on Alcator C-Mod used analog circuitry to perform this function, measuring Te, VF, and Isat at 1.1 MSPS. Recently, a new prototype digital MLP controller has been implemented on a Red Pitaya Field Programmable Gate Array (FPGA) board which reproduces the functionality of the original controller and performs all data acquisition. There is also the potential to provide the plasma parameters externally for use with feedback control systems. The use of FPGA technology means the system is readily customizable at a fraction of the development time and implementation cost. A second Red Pitaya was used to test the MLP by simulating the current response of a physical probe using C-Mod experimental measurements. This project is available as a git repository to facilitate extensibility (e.g., real-time control outputs and more voltage states) and scalability through collaboration.

47 OTHER INSTRUMENTATION↗

MO-AB-BRA-08: A Modular Multi-Source X-Ray Tube for Novel Computed Tomography Applications

Purpose: To develop and build a practical implementation of an x-ray line source for the rapidly increasing number of multi-source imaging applications in CT. Methods: An innovative x-ray tube was designed using CST Particle Studio, ANSYS, and SolidWorks. A slowly varying magnetic field is synchronized with microsecond gating of multiple thermionic electron sources. Electrostatic simulations were run to optimize the geometry of the optics and prevent electrode arcing. Magnetostatic simulations were used for beam deflection studies and solenoid design. Particle beam trajectories were explored with an emphasis on focusing, acceleration, deflection, and space charge effects. Thermal constraints were analyzed for both transient and steady-state regimes. Electromagnetic simulations informed the design of a prototype unit under construction. Results: Particle tracking simulations for a benchtop system demonstrate that three 80 keV electron beams are able to be finely controlled and laterally swept a combined distance of 15 cm over a stationary target with an oscillating magnetic field in the hundreds of gauss. The beams are pulsed according to scanning sequences developed for implementation in a mock stationary CT scanner capable of a 30 ms temporal resolution. Beam spot diameters are approximately 1 mm for 30 mA beams and the stationary target stays well within thermal limits. The relevant hardware and control circuits were developed for incorporation into a physical prototype. Conclusion: A new multi-source x-ray tube was designed in a modular form factor to push the barriers of high-speed CT and spur growth in emerging imaging applications. This technology can be used as the basis for a stationary high-speed CT scanner, a system for generating a virtual fan-beam for dose reduction, or for reducing scatter radiation in cone-beam CT utilizing a tetrahedron beam CT geometry. A 2.4 kW benchtop system is currently being built to show proof of concept for the tube. Support for this research was provided by the University of Wisconsin Madison, Office of the Vice Chancellor for Research and Graduate Education with funding from the Wisconsin Alumni Research Foundation.

60 APPLIED LIFE SCIENCES↗

High Energy High Power Battery Exceeding PHEV40 Requirements

TIAX has developed long-life lithium-ion cells that can meet and exceed the energy and power targets (200Wh/kg and 800W/kg pulse power) set out by DOE for PHEV40 batteries. To achieve these targets, we selected and scaled-up a high capacity version of our proprietary high energy and high power CAM-7® cathode material. We paired the cathode with a blended anode containing Si-based anode material capable of delivering high capacity and long life. Furthermore, we optimized the anode blend composition, cathode and anode electrode design, and selected binder and electrolyte compositions to achieve not only the best performance, but also long life. By implementing CAM-7 with a Si-based blended anode, we built and tested prototype 18650 cells that delivered measured specific energy of 198Wh/kg total energy and 845W/kg at 10% SOC (projected to 220Wh/kg in state-of-the-art 18650 cell hardware and 250Wh/kg in 15Ah pouch cells). These program demonstration cells achieved 90% capacity retention after 500 cycles in on-going cycle life testing. Moreover, we also tested the baseline CAM-7/graphite system in 18650 cells showing that 70% capacity retention can be achieved after ~4000 cycles (20 months of on-going testing). Ultimately, by simultaneously meeting the PHEV40 power and energy targets and providing long life, we have developed a Li-ion battery system that is smaller, lighter, and less expensive than current state-of-the-art Li-ion batteries.

25 ENERGY STORAGE↗

CalTestBed - Opus 12 - Study of Diffusion Media and Polymer Electrolyte Materials in Devices for CO2 to Fuels (CRADA Final Report)

Capturing carbon dioxide is one of the great ways to reduce the CO2 in the atmosphere while providing valuable renewable energy. Opus 12 is a Cyclotron Road startup using a membrane-electrode assembly (MEA) design. LBNL helped Opus 12 optimize its MEA design in this project through materials characterization and in situ studies. The finding of this project was used to develop a set of ideas for their MEA improvement under different operating conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of Stable Solid Oxide Electrolysis Cells for Low-Cost Hydrogen Production

The project objective was to demonstrate a solid oxide cell-based steam electrolysis stack that exhibits robustness, reliability, endurance, hydrogen purity, and produces hydrogen at elevated pressure of 2 to 3 bar. Innovative materials and processing methods were evaluated to improve degradation characteristics. Performance improvement focused on nearly all layers involved in the cell and stack assembly. Primary attention was paid to zirconia-ceria interface resistance control via sintering optimization and decrease in degradation from the oxygen electrode by evaluating low strontium (Sr) or Sr-free composition for both the oxygen electrode and current collection layer. Stack robustness was addressed by validating redox tolerance of fuel electrode, confirming capability of cells to survive repeated thermal cycles, studying the effect of pressure on performance and degradation, evaluating the effect of contamination on fuel and oxygen electrode performance and degradation, and identifying mitigation strategies to improve performance. The characterization included evaluation of electrochemical performance and stability followed by microstructural analysis. At the cell level, performance and stability improvements were achieved by incorporating a Sr-free oxygen electrode and a denser oxygen electrode barrier layer. At the stack level, pressurized operation reduces demand on first stage compression, the redox tolerant fuel electrode mitigates risk from service interruptions, and improvements to interconnect coating alleviate chromium (Cr) contamination effects. The denser barrier layer was achieved by adding a sintering aid to the samaria-doped ceria (SDC) composition that reduced sintering temperature by 150 °C. The resulting density was on par with the baseline SDC barrier layer density and the lower sintering temperature resulted in less resistive phase formation during sintering. Button cell tests did not demonstrate a change in performance when exposed to silicon (Si) or manganese (Mn) impurities to the fuel electrode and Cr impurity to the oxygen electrode. More detailed study however is warranted. The project addressed SOEC performance and stability at the cell and stack levels through a systematic approach to known sources of degradation that were combined and tested in three stack tests using an electrolyte supported cell design to allow for evaluation of a variety of fuel and oxygen electrode compositions. STK-82 and STK-83 had identical compositions. STK-100 incorporated the best materials and processing variables developed under this and concurrent projects, and was tested at elevated pressure in steam electrolysis. • STK-82 recovered performance after redox and thermal cycling, demonstrating the robustness of the stack and seals. It exhibited stable performance in testing for 500 hours in SOEC mode, followed by 300 hours of cycling between SOEC and SOFC tests. Degradation during SOEC operation was 1.8 %/ 1,000 hours. • STK-83 generated hydrogen at >80% steam conversion, and oxygen above 98.5 % purity during pressurized operation. Both hydrogen and oxygen were generated at 3 barg pressure without the use of a pressure vessel. In addition to balanced pressure, electrolysis operation at 1 bar differential pressure across anode and cathode was also demonstrated to substantial the robustness of the cell and seal. • STK-100 measured at initial ambient pressure conditions showed an area specific resistance of 1.1 ohm-cm 2 , and STK-83 had 1.3 ohm-cm 2 .

08 HYDROGEN↗

dc discharge cell for laser optogalvanic spectroscopy

A dc electrical discharge cell for laser optogalvanic spectroscopy has been designed and tested. Signal optimization is achieved through the use of adjustable electrode positions and an orthogonal geometry between the probe laser and the discharge axis. Results are presented for visible dye laser and infrared diode laser studies of selected neutral, radical, and ion species.

Webster, C. R.↗

Corrosion testing of candidates for the alkaline fuel cell cathode

It is desirable to employ a corrosion screening test for catalyst or support candidates for the fuel cell cathode before entering upon optimization of the candidate or of the catalytic electrode. To this end, corrosion test electrodes, intended for complete immersion and maximum wetting, have been made with 30 to 40 vol. pct Teflon; with perovskites this is about 10 to 15 pct. The candidates were synthesized by methods intended for single-phase product without special emphasis on high surface area, although the substances tested were no coarser than 2 m squared/g. A typical loading was 25 mg/cm sq of the pure substance, usually on gold screen, a few mm squared of which were left bare for contacting. Contact to the gold lead wire was made by welding with a micro-torch or a spot-welder. Corrosion testing consisted of obtaining current-voltage data under flowing inert gas in the potential region for reduction of O2. The electrode was immersed in 30 pct KOH. Observations were made at 20 C and 80 C, and the results compared with data from gold standards. Results with some perovskites, pyrochlores, spinels, and interstitial compounds will be discussed.

Singer, Joseph↗

High Temperature Steam Electrolysis: Demonstration of Improved Long-Term Performance

Long-term performance is an ongoing issue for hydrogen production based on high-temperature steam electrolysis (HTSE). For commercial deployment, solid-oxide electrolysis stacks must achieve high performance with long-term degradation rates of {approx}0.5%/1000 hours or lower. Significant progress has been achieved toward this goal over the past few years. This paper will provide details of progress achieved under the Idaho National Laboratory high temperature electrolysis research program. Recent long-term stack tests have achieved high initial performance with degradation rates less than 5%/khr. These tests utilize internally manifolded stacks with electrode-supported cells. The cell material sets are optimized for the electrolysis mode of operation. Details of the cells and stacks will be provided along with details of the test apparatus, procedures, and results.

08 HYDROGEN↗

Advanced Redox Flow Batteries for Stationary Electrical Energy Storage: Milestone Report for the DOE Energy Storage Systems Program (FY12 Quarter 1: October 2011 through December 2011)

This report describes the status of the advanced redox flow battery research being performed at Pacific Northwest National Laboratories for the U.S. Department of Energy’s Energy Storage Systems Program. The Quarter 1 of FY2012 Milestone was completed on time. The milestone entails completion of evaluation and optimization of single cell components for the two advanced redox flow battery electrolyte chemistries recently developed at the lab, the all vanadium (V) mixed acid and V-Fe mixed acid solutions. All the single cell components to be used in future kW-scale stacks have been identified and optimized in this quarter, which include solution electrolyte, membrane or separator; carbon felt electrode and bi-polar plate. Varied electrochemical, chemical and physical evaluations were carried out to assist the component screening and optimization. The mechanisms of the battery capacity fading behavior for the all vanadium redox flow and the Fe/V battery were discovered, which allowed us to optimize the related cell operation parameters and continuously operate the system for more than three months without any capacity decay.

25 ENERGY STORAGE↗

Carbon-Binder Weight Loading Optimization for Improved Lithium-Ion Battery Rate Capability

Battery performance is strongly correlated with electrode microstructure and weight loading of the electrode components. Among them are the carbon-black and binder additives that enhance effective conductivity and provide mechanical integrity. However, these both reduce effective ionic transport in the electrolyte phase and reduce energy density. Therefore, an optimal additive loading is required to maximize performance, especially for fast charging where ionic transport is essential. Such optimization analysis is however challenging due to the nanoscale imaging limitations that prevent characterizing this additive phase and thus quantifying its impact on performance. Herein, an additive-phase generation algorithm has been developed to remedy this limitation and identify percolation threshold used to define a minimal additive loading. Improved ionic transport coefficients from reducing additive loading has been then quantified through homogenization calculation, macroscale model fitting, and experimental symmetric cell measurement, with good agreement between the methods. Rate capability test demonstrates capacity improvement at fast charge at the beginning of life, from 37% to 55%, respectively for high and low additive loading during 6C CC charging, in agreement with macroscale model, and attributed to a combination of lower cathode impedance, reduced electrode tortuosity and cathode thickness.

25 ENERGY STORAGE↗

Carbon-Binder Optimization for Lithium-Ion Battery Extreme Fast Charge

Battery performance is strongly correlated with electrode microstructure and weight loading of the electrode components. Among them are the carbon-black and binder additives that enhance effective conductivity and provide mechanical integrity. However, these both reduce effective ionic transport in the electrolyte phase and reduce energy density. Therefore, an optimal additive loading is required to maximize performance, especially for fast charging where ionic transport is essential. Such optimization analysis is however challenging due to the nanoscale imaging limitations that prevent characterizing this additive phase and thus quantifying its impact on performance. Herein, an additive-phase generation algorithm has been developed to remedy this limitation and identify percolation threshold used to define a minimal additive loading. Improved ionic transport coefficients from reducing additive loading has been then quantified through homogenization calculation, macroscale model fitting, and experimental symmetric cell measurement, with good agreement between the methods. Rate capability test demonstrates capacity improvement at fast charge at the beginning of life, from 37% to 55%, respectively for high and low additive loading during 6C CC charging, in agreement with macroscale model, and attributed to a combination of lower cathode impedance, reduced electrode tortuosity and cathode thickness.

carbon-binder additives↗

Effects of Pore Size on Na/Ca Ion Selectivity Using Flow Through Electrode Capacitive Deionization

In flow through electrode capacitive deionization (fte-CDI), low salinity brackish water flows through two porous carbon electrodes. When an electrical potential difference is applied over the electrodes, ions migrate towards micropores, cleaning the water. Ion selectivity can be controlled by taking advantage of charge and ionic radius differences as well as the applied potential and pore size of the electrodes. The research outlined in this paper consists primarily of running fte-CDI cells with electrodes of varying pore size distributions to experimentally determine the parameters for optimal total salt removal and sodium/calcium ion selectivity. Five fte-CDI cells of different activation were fabricated using microporous hierarchical carbon aerogel materials (HCAMs) as electrodes. For each cell, cyclic voltammetry using 20 mM NaCl solution and 10 mM CaCl2 solution was performed at a scan rate of 0.5, 0.75, and 1 mV/s with a potential window from -0.8 V to +0.8 V. The same pure salts were desalinated in hourly charge/discharge cycles at ±1 V. A mixture of 5 mM NaCl and 2.5 mM CaCl2 was desalinated at 0.6, 0.8, 1.0, and 1.2 V. The collected charge and discharge streams were analyzed with ion chromatography (IC). The IC data for the two least activated cells showed minimal calcium adsorption compared to sodium. All cells adsorbed sodium, regardless of activation, while only highly activated cells removed calcium. This data indicates a tradeoff between more total salt removed at high voltages and selectivity of sodium over calcium at low voltages. Future research with nitrogen porosimetry could provide a quantitative value for the optimal pore size distribution.

36 MATERIALS SCIENCE↗

An engineered lactate oxidase based electrochemical sensor for continuous detection of biomarker lactic acid in human sweat and serum

Lactate levels in humans reveal intensity and duration of exertion and provide a critical readout for the severity of life-threatening illnesses such as pediatric sepsis. Using the lactate oxidase enzyme (Lox) from Aerococcus viridians, we demonstrated its functionality for lactate electrochemical sensing in physiological fluids in a lab setting. The structure and dynamics of LOx were validated by crystallography, X-ray scattering, and hydroxyl radical protein footprinting. This provided a validated protein template for understanding and designing an enzyme-based electrochemical sensing elements. Using this template, LOx enzyme variants were generated and compared. Comparison of the variants demonstrates that one exhibits effective lactate sensing at significantly reduced operating voltages. Additionally, we demonstrate that the four hexahistidine-tags on each enzyme tetramer are sufficient for immobilization to create a durable, functional sensor, with no need for a covalent attachment, enabling self-immobilization and eliminating the need for additional immobilization steps. The functionality of the LOx enzyme variants was verified at physiological lactate concentrations in both human serum (0–4 mM) and artificial sweat (0–100 mM) using 3-electrode setups for analysis of the three variants in parallel. Accuracy of measurement in both artificial sweat and human serum were high. Employing a microfluidic flow cell, we successfully monitored varying lactate levels in physiological fluids continuously over a 2h period. Overall, this optimized LOx enzyme, which self-immobilizes onto gold sensing electrodes, facilitates efficient and reliable lactate detection and continuous monitoring at reduced operating voltages suitable for further development towards commercial use.

60 APPLIED LIFE SCIENCES↗

Extreme high vacuum for polarized electron sources

Nuclear physics experiments often require highly polarized electron beams to do precise measurements of the structure and size of nucleons and the nucleus, as well as for searches for physics beyond the standard model. Jefferson Lab?s electron source, with polarization near 90%, has been providing polarized electron beams for CEBAF for over two decades. Development is underway for polarized electron sources at MESA at Mainz and the Electron Ion Collider at Brookhaven National Lab, and there is potential for polarized electron beam in the future at facilities including the International Linear Collider, an electron upgrade at CERN, and the SuperKEKB collider in Japan. At Jefferson Lab there are even plans to make use of polarized electrons to make a polarized positron source for experimental nuclear physics. High polarization electron beams are generated using photoemission from strained superlattice GaAs based photocathodes, and photocathode lifetime is limited by the ionization of residual gas in the system, which is then accelerated into the photocathode. Extreme high vacuum (near 1x10-10 Pa) is required to operate the Jefferson Lab polarized electron source with an acceptable lifetime, and the upcoming projects will need various combinations of higher current, higher bunch charge and longer photocathode lifetimes. To meet the vacuum requirements for polarized electron sources, every component for a polarized electron source must be optimized, including chamber materials, pumps, bakeout procedure and the high voltage electrode geometry and processing. Each change in these components must be evaluated offline before being used in the accelerator, and effects on pressure are difficult to evaluate even using XHV-optimized hot filament ionization gauges. In fact, we do not get a final evaluation of system modifications until an electron source is built, installed and lifetime measurements are made over the course of months or years of operation. I will be discussing the evolution of vacuum in the Jefferson Lab polarized source system toward XHV pressures and discuss the characterization and limitations measured for commercially available XHV vacuum gauges. Finally, I?ll present the effect of system pressure on photocathode lifetime and highlight how XHV pressure standards can benefit the ongoing efforts to improve vacuum for the next generation of polarized electron sources.

Stutzman, Marcy↗

Optimized nanoporous materials.

Nanoporous materials have maximum practical surface areas for electrical charge storage; every point in an electrode is within a few atoms of an interface at which charge can be stored. Metal-electrolyte interfaces make best use of surface area in porous materials. However, ion transport through long, narrow pores is slow. We seek to understand and optimize the tradeoff between capacity and transport. Modeling and measurements of nanoporous gold electrodes has allowed us to determine design principles, including the fact that these materials can deplete salt from the electrolyte, increasing resistance. We have developed fabrication techniques to demonstrate architectures inspired by these principles that may overcome identified obstacles. A key concept is that electrodes should be as close together as possible; this is likely to involve an interpenetrating pore structure. However, this may prove extremely challenging to fabricate at the finest scales; a hierarchically porous structure can be a worthy compromise.

36 MATERIALS SCIENCE↗