Search NASA⌕ Search

SEARCH · Search NASA

Results for “PDF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Exploration of thermal counterflow in He II using particle tracking velocimetry

Flow visualization using particle image velocimetry (PIV) and particularly particle tracking velocimetry (PTV) has been applied to thermal counterflow in He II for nearly two decades now, but the results remain difficult to interpret because tracer particle motion can be influenced by both the normal fluid and superfluid components of He II as well as the quantized vortex tangle. For instance, in one early experiment it was observed (using PTV) that tracer particles move at the normal fluid velocity v n , while in another it was observed (using PIV) that particles move at v n /2. Besides the different visualization methods, the range of applied heat flux investigated by these experiments differed by an order of magnitude. To resolve this apparent discrepancy and explore the statistics of particle motion in thermal counterflow, we apply the PTV method to a wide range of heat flux at a number of different fluid temperatures. In our analysis, we introduce a scheme for analyzing the velocity of particles presumably moving with the normal fluid separately from those presumably influenced by the quantized vortex tangle. Our results show that for lower heat flux there are two distinct peaks in the streamwise particle velocity probability density function (PDF), with one centered at the normal fluid velocity v n (named G2 for convenience) while the other is centered near v n /2 (G1). For higher heat flux there is a single peak centered near v n /2 (G3). Using our separation scheme, we show quantitatively that there is no size difference between the particles contributing to G1 and G2. We also show that nonclassical features of the transverse particle velocity PDF arise entirely from G1, while the corresponding PDF for G2 exhibits the classical Gaussian form. The G2 transverse velocity fluctuation, backed up by second sound attenuation in decaying counterflow, suggests that large-scale turbulence in the normal fluid is absent from the two-peak region. We offer a brief discussion of the physical mechanisms that may be responsible for our observations, revealing that G1 velocity fluctuations may be linked to fluctuations of quantized vortex line velocity, and suggest a number of numerical simulations that may reveal the underlying physics in detail.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Oxygen point defect accumulation in single-phase U O 2 + x

UO 2.07 was characterized using neutron total scattering in order to elucidate defect morphology in the low oxygen-to-metal regime (x < 0.125 for UO 2+x ). Data were collected at temperatures (600 and 1000 °C) coinciding with the single-phase UO 2+x region of the established phase diagram, and results were compared with data of stoichiometric UO 2 collected at near-identical temperatures. Experimental data were modeled and interpreted using a holistic approach employing a combination of analyses that characterized multiple spatial length scales. Preferential modeling of long-range atomic arrangements with Rietveld refinement suggests the existence of primarily monointerstitials in UO 2.07 , whereas preferential modeling of short-range atomic structures with small-box pair distribution function (PDF) refinement indicates the presence of defect clusters in UO 2.07 . Simultaneous modeling of multiple length scales using complementary reverse Monte Carlo (RMC) and molecular dynamics (MD) methods confirms that excess oxygen atoms in UO 2.07 exist as small defects, such as monointerstitials and di-interstitials. RMC and MD results agree with diffraction analysis but differ significantly from small-box PDF refinements, which may be related to a lack of intermediate- and long-range structural information gained from the small-box PDF refinement procedure. Employing a combination of analysis methods with varying length-scale sensitivities enabled more accurate assessment of the UO 2+x defect structure. Furthermore, our findings provide experimental support for previously predicted di-interstitial defect morphologies in UO 2+x that highly influence the accurate prediction of bulk physiochemical properties of UO 2+x , such as oxygen diffusivity.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Finite Size Effects on the Real-Space Pair Distribution Function of Nanoparticles

The pair distribution function (PDF) method is a powerful approach for the analysis of the structure of nanoparticles. An important approximation used in nanoparticle PDF simulations is the incorporation of a form factor describing nanoparticle size and shape. The precise effect of the form factor on the PDF is determined by both particle shape and structure if these characteristics are both anisotropic and correlated. The correct incorporation of finite size effects is important for distinguishing and quantifying the structural consequences of small particle size in nanomaterials.

54 ENVIRONMENTAL SCIENCES↗

DShaper: An approach for handling missing low-Q data in pair distribution function analysis of nanostructured systems

In this work we discuss the potential problems and currently available solutions in modeling powder-diffraction based pair-distribution function (PDF) data from systems where morphological feature information content includes distances in the nanometer length scale, such as finite nanoparticles, nanoporous networks, and nanoscale precipitates in bulk materials. The implications of an experimental finite minimum Q-value are addressed by simulation, which also demonstrates the advantages of combining PDF data with small angle scattering data (SAS). In addition, we introduce a simple Fortran90 code, DShaper , which may be incorporated into PDF data fitting routines in order to approximate the so-called shape-function for any atomistic model.

36 MATERIALS SCIENCE↗

Evidence of anatase intergrowths formed during slow cooling of reduced ilmenite

Controlling the parameters during synthetic rutile production is essential to minimize production costs and ensure final product quality. Powder X-ray diffraction (PXRD) is typically used within the industry to guide process control. This work investigated the source of unusual features observed in the PXRD pattern of a slow-cooled reduced ilmenite (RI), which were not observed for a rapid-cooled RI. For the slow-cooled RI, the 002 peak of M 3 O 5 (anosovite) had disappeared and the intensity of the $ \overline{2}03\ $, 203, 204 and 402 peaks had decreased significantly compared to the pattern for the rapid-cooled RI. Using transmission electron microscopy, selected area electron diffraction (SAED) and pair distribution function (PDF) analysis, the authors attribute these features to M 3 O 5 –anatase intergrowth formation, which causes a loss in long-range order along the M 3 O 5 c axis. Strong diffuse streaking in the SAED patterns was also evident and supported the presence of disordered intergrowths from the oxidation of M 3 O 5 . PDF analysis showed a significant improvement in the fit to the data for the slow-cooled RI, primarily in the <17 Å region, when anatase was added to the PDF model. The results presented here highlight the importance of the reduction and cooling stages during the formation of these industrially relevant RI minerals, which may be used to direct the production process and final TiO 2 product quality.

D'Angelo, Anita M. (ORCID:0000000230685288)↗

Microfluidic electrochemical cell for in situ structural characterization of amorphous thin-film catalysts using high-energy X-ray scattering

Porous, high-surface-area electrode architectures are described that allow structural characterization of interfacial amorphous thin films with high spatial resolution under device-relevant functional electrochemical conditions using high-energy X-ray (>50 keV) scattering and pair distribution function (PDF) analysis. Porous electrodes were fabricated from glass-capillary array membranes coated with conformal transparent conductive oxide layers, consisting of either a 40 nm–50 nm crystalline indium tin oxide or a 100 nm–150 nm-thick amorphous indium zinc oxide deposited by atomic layer deposition. These porous electrodes solve the problem of insufficient interaction volumes for catalyst thin films in two-dimensional working electrode designs and provide sufficiently low scattering backgrounds to enable high-resolution signal collection from interfacial thin-film catalysts. For example, PDF measurements were readily obtained with 0.2 Å spatial resolution for amorphous cobalt oxide films with thicknesses down to 60 nm when deposited on a porous electrode with 40 µm-diameter pores. This level of resolution resolves the cobaltate domain size and structure, the presence of defect sites assigned to the domain edges, and the changes in fine structure upon redox state change that are relevant to quantitative structure–function modeling. The results suggest the opportunity to leverage the porous, electrode architectures for PDF analysis of nanometre-scale surface-supported molecular catalysts. In addition, a compact 3D-printed electrochemical cell in a three-electrode configuration is described which is designed to allow for simultaneous X-ray transmission and electrolyte flow through the porous working electrode.

36 MATERIALS SCIENCE↗

Using powder XRD and pair distribution function to determine anisotropic atomic displacement parameters of orthorhombic tridymite and tetragonal cristobalite

Determination of the crystal structures of low-temperature tridymite and cristobalite using single-crystal XRD has been challenging because they generally occur as metastable fine-grained crystals in the geological environment. Therefore, using powder diffraction and scattering techniques is critical to study the low-temperature crystals. Synchrotron powder X-ray diffraction (XRD), pair distribution function (PDF) and transmission electron microscopy were used to investigate the structure of orthorhombic tridymite with C 222 1 symmetry and tetragonal cristobalite with P 4 1 2 1 2 symmetry, including their anisotropic atomic displacement parameters (ADPs). Rietveld refinement was used to determine the unit-cell parameters, fractional coordinates and isotropic atomic displacement parameters ( U iso ) of the tridymite and cristobalite. The PDF method was used to determine ADPs for each atom. The results suggest that the crystal structure with high quality ADP values can be obtained using the combined methods of XRD and PDF analyses. The method can be used for characterizing crystals that are not suitable for single-crystal XRD.

Lee, Seungyeol (ORCID:0000000201751389)↗

Towards solution and refinement of organic crystal structures by fitting to the atomic pair distribution function

In this study, a method towards the solution and refinement of organic crystal structures by fitting to the atomic pair distribution function (PDF) is developed. Approximate lattice parameters and molecular geometry must be given as input. The molecule is generally treated as a rigid body. The positions and orientations of the molecules inside the unit cell are optimized starting from random values. The PDF is obtained from carefully measured X-ray powder diffraction data. The method resembles `real-space' methods for structure solution from powder data, but works with PDF data instead of the diffraction pattern itself. As such it may be used in situations where the organic compounds are not long-range-ordered, are poorly crystalline, or nanocrystalline. The procedure was applied to solve and refine the crystal structures of quinacridone (β phase), naphthalene and allopurinol. In the case of allopurinol it was even possible to successfully solve and refine the structure in P1 with four independent molecules. As an example of a flexible molecule, the crystal structure of paracetamol was refined using restraints for bond lengths, bond angles and selected torsion angles. In all cases, the resulting structures are in excellent agreement with structures from single-crystal data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fault diagnosis and fault tolerant control for T-S fuzzy stochastic distribution systems subject to sensor and actuator faults

The problem of fault diagnosis (FD) and fault tolerant control (FTC) for a class of Takagi-Sugeno (T-S) fuzzy stochastic distribution control (SDC) systems subject to sensor and actuator faults is discussed in this paper. First, fuzzy logic models are used to approximate the output probability density function (PDF). Next, an adaptive augmented state/fault diagnosis observer is proposed to estimate the system state, sensor and the actuator faults simultaneously. New expected weights based on the sensor fault estimation information and a PI-type fuzzy feedback fault tolerant (FT) controller are designed to compensate the effect of sensor fault and actuator fault simultaneously. When the sensor fault occurs, the expected objective is redesigned to compensate the sensor fault. Meanwhile, the PI controller can compensate the effect of actuator fault, and the output PDF of the system can still track the desired PDF after the fault occurs. Finally, an example of quality distribution control in chemical reaction process is given to confirm the effectiveness of the algorithm.

42 ENGINEERING↗

Simultaneous numerical representation of soil microsite production and consumption of carbon dioxide, methane, and nitrous oxide using probability distribution functions

Production and consumption of nitrous oxide (N 2 O), methane (CH 4 ), and carbon dioxide (CO 2 ) are affected by complex interactions of temperature, moisture, and substrate supply, which are further complicated by spatial heterogeneity of the soil matrix. This microsite heterogeneity is often invoked to explain non-normal distributions of greenhouse gas (GHG) fluxes, also known as hot spots and hot moments. To advance numerical simulation of these belowground processes, we expanded the Dual Arrhenius and Michaelis-Menten (DAMM) model, to apply it consistently for all three GHGs with respect to the biophysical processes of production, consumption, and diffusion within the soil, including the contrasting effects of oxygen (O 2 ) as substrate or inhibitor for each process. High-frequency chamber-based measurements of all three GHGs at the Howland Forest (ME, USA) were used to parameterize the model using a multiple constraint approach. The area under a soil chamber is partitioned according to a bivariate lognormal probability distribution function (PDF) of carbon (C) and water content across a range of microsites, which leads to a PDF of heterotrophic respiration and O 2 consumption among microsites. Linking microsite consumption of O 2 with a diffusion model generates a broad range of microsite concentrations of O 2 , which then determines the PDF of microsites that produce or consume CH 4 and N 2 O, such that a range of microsites occurs with both positive and negative signs for net CH 4 and N 2 O flux. Results demonstrate that it is numerically feasible for microsites of N 2 O reduction and CH 4 oxidation to co-occur under a single chamber, thus explaining occasional measurement of simultaneous uptake of both gases. Simultaneous simulation of all three GHGs in a parsimonious modeling framework is challenging, however it increases confidence that agreement between simulations and measurements is based on skillful numerical representation of processes across a heterogeneous environment.

59 BASIC BIOLOGICAL SCIENCES↗

Respiratory motion sampling in 4DCT reconstruction for radiotherapy

Purpose: Phase-based and amplitude-based sorting techniques are commonly used in four-dimensional CT (4DCT) reconstruction. However, effect of these sorting techniques on 4D dose calculation has not been explored. In this study, the authors investigated a candidate 4DCT sorting technique by comparing its 4D dose calculation accuracy with that for phase-based and amplitude-based sorting techniques.Method: An optimization model was formed using organ motion probability density function (PDF) in the 4D dose convolution. The objective function for optimization was defined as the maximum difference between the expected 4D dose in organ of interest and the 4D dose calculated using a 4DCT sorted by a candidate sampling method. Sorting samples, as optimization variables, were selected on the respiratory motion PDF assessed during the CT scanning. Breathing curves obtained from patients' 4DCT scanning, as well as 3D dose distribution from treatment planning, were used in the study. Given the objective function, a residual error analysis was performed, and k-means clustering was found to be an effective sampling scheme to improve the 4D dose calculation accuracy and independent with the patient-specific dose distribution. Results: Patient data analysis demonstrated that the k-means sampling was superior to the conventional phase-based and amplitude-based sorting and comparable to the optimal sampling results. For phase-based sorting, the residual error in 4D dose calculations may not be further reduced to an acceptable accuracy after a certain number of phases, while for amplitude-based sorting, k-means sampling, and the optimal sampling, the residual error in 4D dose calculations decreased rapidly as the number of 4DCT phases increased to 6.Conclusion: An innovative phase sorting method (k-means method) is presented in this study. The method is dependent only on tumor motion PDF. It could provide a way to refine the phase sorting in 4DCT reconstruction and is effective for 4D dose accumulation. Optimized sorting techniques could achieve acceptable residuals (less than 0.5% of the prescription dose) using 6 sorting samples, which is much better than amplitude-based or phase-based sorting. Further increase in sorting phase number exceeding 6 or more may not be necessary when using the k-means sampling or optimal sampling points.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An analysis of the uncertainty and bias in DCE-MRI measurements using the spoiled gradient-recalled echo pulse sequence

Purpose: The pharmacokinetic parameters derived from dynamic contrast-enhanced (DCE) MRI have been used in more than 100 phase I trials and investigator led studies. A comparison of the absolute values of these quantities requires an estimation of their respective probability distribution function (PDF). The statistical variation of the DCE-MRI measurement is analyzed by considering the fundamental sources of error in the MR signal intensity acquired with the spoiled gradient-echo (SPGR) pulse sequence. Methods: The variance in the SPGR signal intensity arises from quadrature detection and excitation flip angle inconsistency. The noise power was measured in 11 phantoms of contrast agent concentration in the range [0–1] mM (in steps of 0.1 mM) and in onein vivo acquisition of a tumor-bearing mouse. The distribution of the flip angle was determined in a uniform 10 mM CuSO{sub 4} phantom using the spin echo double angle method. The PDF of a wide range of T1 values measured with the varying flip angle (VFA) technique was estimated through numerical simulations of the SPGR equation. The resultant uncertainty in contrast agent concentration was incorporated in the most common model of tracer exchange kinetics and the PDF of the derived pharmacokinetic parameters was studied numerically. Results: The VFA method is an unbiased technique for measuringT1 only in the absence of bias in excitation flip angle. The time-dependent concentration of the contrast agent measured in vivo is within the theoretically predicted uncertainty. The uncertainty in measuring K{sup trans} with SPGR pulse sequences is of the same order, but always higher than, the uncertainty in measuring the pre-injection longitudinal relaxation time (T1{sub 0}). The lowest achievable bias/uncertainty in estimating this parameter is approximately 20%–70% higher than the bias/uncertainty in the measurement of the pre-injection T1 map. The fractional volume parameters derived from the extended Tofts model were found to be extremely sensitive to the variance in signal intensity. The SNR of the pre-injection T1 map indicates the limiting precision with which K{sup trans} can be calculated. Conclusions: Current small-animal imaging systems and pulse sequences robust to motion artifacts have the capacity for reproducible quantitative acquisitions with DCE-MRI. In these circumstances, it is feasible to achieve a level of precision limited only by physiologic variability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-182: Reproducibility of Tumor Motion Probability Distribution Function in Stereotactic Body Radiation Therapy of Lung Using Real-Time Tumor-Tracking Radiotherapy System

Purpose: We aim to achieve new four-dimensional radiotherapy (4DRT) using the next generation real-time tumor-tracking (RTRT) system and flattening-filter-free techniques. To achieve new 4DRT, it is necessary to understand the respiratory motion of tumor. The purposes of this study were: 1.To develop the respiratory motion analysis tool using log files. 2.To evaluate the reproducibility of tumor motion probability distribution function (PDF) during stereotactic body RT (SBRT) of lung tumor. Methods: Seven patients having fiducial markers closely implanted to the lung tumor were enrolled in this study. The positions of fiducial markers were measured using the RTRT system (Mitsubishi Electronics Co., JP) and recorded as two types of log files during the course of SBRT. For each patients, tumor motion range and tumor motion PDFs in left-right (LR), anterior-posterior (AP) and superior-inferior (SI) directions were calculated using log files of all beams per fraction (PDFn). Fractional PDF reproducibility (Rn) was calculated as Kullback-Leibler (KL) divergence between PDF1 and PDFn of tumor motion. The mean of Rn (Rm) was calculated for each patient and correlated to the patient’s mean tumor motion range (Am). The change of Rm during the course of SBRT was also evluated. These analyses were performed using in-house developed software. Results: The Rm were 0.19 (0.07–0.30), 0.14 (0.07–0.32) and 0.16 (0.09–0.28) in LR, AP and SI directions, respectively. The Am were 5.11 mm (2.58–9.99 mm), 7.81 mm (2.87–15.57 mm) and 11.26 mm (3.80–21.27 mm) in LR, AP and SI directions, respectively. The PDF reproducibility decreased as the tumor motion range increased in AP and SI direction. That decreased slightly through the course of RT in SI direction. Conclusion: We developed the respiratory motion analysis tool for 4DRT using log files and quantified the range and reproducibility of respiratory motion for lung tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-AB-201-02: An Automated Treatment Plan Quality Assurance Program for Tandem and Ovoid High Dose-Rate Brachytherapy

Purpose: For tandem and ovoid (T&O) HDR brachytherapy in our clinic, it is required that the planning physicist manually capture ∼10 images during planning, perform a secondary dose calculation and generate a report, combine them into a single PDF document, and upload it to a record- and-verify system to prove to an independent plan checker that the case was planned correctly. Not only does this slow down the already time-consuming clinical workflow, the PDF document also limits the number of parameters that can be checked. To solve these problems, we have developed a web-based automatic quality assurance (QA) program. Methods: We set up a QA server accessible through a web- interface. A T&O plan and CT images are exported as DICOMRT files and uploaded to the server. The software checks 13 geometric features, e.g. if the dwell positions are reasonable, and 10 dosimetric features, e.g. secondary dose calculations via TG43 formalism and D2cc to critical structures. A PDF report is automatically generated with errors and potential issues highlighted. It also contains images showing important geometric and dosimetric aspects to prove the plan was created following standard guidelines. Results: The program has been clinically implemented in our clinic. In each of the 58 T&O plans we tested, a 14- page QA report was automatically generated. It took ∼45 sec to export the plan and CT images and ∼30 sec to perform the QA tests and generate the report. In contrast, our manual QA document preparation tooks on average ∼7 minutes under optimal conditions and up to 20 minutes when mistakes were made during the document assembly. Conclusion: We have tested the efficiency and effectiveness of an automated process for treatment plan QA of HDR T&O cases. This software was shown to improve the workflow compared to our conventional manual approach.

60 APPLIED LIFE SCIENCES↗

Score-Based Physics-Informed Neural Networks for High-Dimensional Fokker–Planck Equations

The Fokker-Planck (FP) equation is a foundational partial differential equation (PDE) in stochastic processes involving Brownian motions. However, the curse of dimensionality (CoD) poses a formidable challenge when dealing with high-dimensional FP equations. Although Monte Carlo simulation and (vanilla) Physics-Informed Neural Networks (PINNs) have shown the potential to tackle CoD, both methods exhibit significant numerical errors in high dimensions when dealing with the probability density function (PDF) associated with Brownian motion. The point-wise PDF values tend to decrease exponentially as dimensionality increases, surpassing the precision of numerical simulations and resulting in substantial errors. In addition, due to its massive sampling, Monte Carlo fails to offer fast sampling. Modeling the logarithm likelihood (LL) via vanilla PINNs transforms the FP equation into a notoriously difficult Hamilton-Jacobi-Bellman (HJB) equation, which is impractical for PINN learning, whose error grows rapidly with dimension. To this end, we propose a novel approach utilizing a score-based solver to fit the score function in stochastic differential equations (SDEs). The score function, defined as the gradient of the LL, plays a fundamental role in inferring LL and PDF and enables fast SDE sampling, offering an effective means to overcome the CoD. Three fitting methods, Score Matching (SM), Sliced Score Matching (SSM), and Score-PINN, are introduced, each contributing unique advantages in computational complexity, accuracy, and generality. The proposed score-based SDE solver operates in two stages: first, employing score matching or Score-PINN to acquire the score function; and second, solving the LL via an ordinary differential equation (ODE) using the obtained score function. Comparative evaluations across these methods showcase varying trade-offs. The proposed methodology is evaluated across diverse SDEs, including anisotropic Ornstein-Uhlenbeck processes, geometric Brownian motion, and Brownian motion with varying eigenspace. We also test various distributions, including Gaussian, Log-normal, Laplace, and Cauchy distributions. The numerical results demonstrate the score-based SDE solver’s stability, speed, and performance across different experimental settings, solidifying its potential as a solution to CoD for high-dimensional FP equations.

97 MATHEMATICS AND COMPUTING↗

HERAFitter: Open source QCD fit project

HERAFitter is an open-source package that provides a framework for the determination of the parton distribution functions (PDFs) of the proton and for many different kinds of analyses in Quantum Chromodynamics (QCD). It encodes results from a wide range of experimental measurements in lepton-proton deep inelastic scattering and proton-proton (proton-antiproton) collisions at hadron colliders. These are complemented with a variety of theoretical options for calculating PDF-dependent cross section predictions corresponding to the measurements. The framework covers a large number of the existing methods and schemes used for PDF determination. The data and theoretical predictions are brought together through numerous methodological options for carrying out PDF fits and plotting tools to help visualise the results. While primarily based on the approach of collinear factorisation, HERAFitter also provides facilities for fits of dipole models and transverse-momentum dependent PDFs. The package can be used to study the impact of new precise measurements from hadron colliders. This paper describes the general structure of HERAFitter and its wide choice of options.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Probing the strange content of the proton with charm production in charged current at LHeC

Abstract We study charm production in charged-current deep-inelastic scattering (DIS) using the xFitter framework. Recent results from the LHC have focused renewed attention on the determination of the strange-quark parton distribution function (PDF), and the DIS charm process provides important complementary constraints on this quantity. We examine the current PDF uncertainty and use LHeC pseudodata to estimate the potential improvement from this proposed facility. As xFitter implements both fixed-flavor- and variable-flavor-number schemes, we can compare the impact of these different theoretical choices; this highlights some interesting aspects of multi-scale calculations. We find that the high-statistics LHeC data covering a wide kinematic range could substantially reduce the strange PDF uncertainty.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗