At least 469 records · Page 26

Filler Wire Development for 2195 Aluminum-Lithium

The objective of the research was to determine the susceptibility of submitted welded 2195 plate in an AI (Alternate Immersion) environment. Forty-day AI exposure was completed on 8 welded 2195 stress corrosion samples. No stress corrosion cracking (SCC) was found on any of the samples tested. All 8 samples experienced exfoliation corrosion attack in the heat-affected zone (HAZ) adjacent to the weld. All samples were examined metallographically and showed varying degrees of intergranular corrosion (IG). The filler metal on all samples showed moderate to heavy pitting.

Bjorkman, Gerald W.↗

Control of metal dusting corrosion in Ni-base alloys.

Metal dusting is a major issue in plants used in the production of hydrogen-and methanol-reformer systems, and syngas (H{sub 2}/CO mixtures) systems that are pertinent to the chemical and petrochemical industries. Usually, metal dusting corrosion has two stages: incubation and growth resulting in propagation of metal dusting pits. The two stages were studied by scanning electron microscopy and profile mapping to evaluate the scale of the surface oxide in the initiation and propagation of metal dusting attack. The initiation occurs because of the presence of defects, and the propagation is determined by the diffusion of carbon into the alloy. The carbon diffusion pathways can be blocked by periodically oxidizing alloy surface at moderate temperatures in controlled atmospheres. It was concluded that metal dusting degradation can be mitigated by selecting an alloy with a long incubation time and subjecting it to intermediate oxidation.

02 PETROLEUM↗

Hot corrosion of sintered alpha-SiC at 1000 C

The hot corrosion of sintered alpha-SiC by thin films of Na2SO4 and Na2CO3 was studied at 1000 C in controlled gas atmospheres. Under all conditions, corrosion led to 10 to 20 times the amount of SiO2 formed in pure oxidation after a 48-h exposure. In addition, small amounts of sodium silicate formed. Melts of Na2SO4/SO3 caused uniform pitting of the SiC substrate; Na2CO3/CO2 melts caused localized pitting and grain-boundary attack. In all cases, the protective SiO2 layer dissolved to form silicate, leading to corrosion. In the sulfate case, free carbon in the SiC promotes this process. In all cases the presence of liquid films is responsible for rapid transport rates and the subsequent rapid reaction.

Jacobson, N. S.↗

The effect of pH on the corrosion behavior of intermetallic compounds Ni{sub 3}(Si,Ti) and Ni{sub 3}(Si,Ti) + 2Mo in sodium chloride solutions

The corrosion behavior of the intermetallic compounds, Ni{sub 3}(Si,Ti) (L1{sub 2}: single phase) and Ni{sub 3}(Si,Ti) + 2Mo (L1{sub 2} and (L12 + Ni{sub ss}) mixture region), has been investigated using an immersion test, electrochemical method and surface analytical method (SEM; scanning electron microscope and EDAX: Energy Dispersive X-ray) in 0.5 kmol/m{sup 3} NaCl solutions at various pH. The corrosion behavior of nickel alloy C-276 was studied under the same experimental conditions as a reference. It was found that the uniform attack was observed on Ni{sub 3}(Si,Ti) for the immersion test at lower pH, while the pitting attack was observed on this compound for this test at neutral solution. Furthermore, Ni{sub 3}(Si,Ti)+2Mo had the preferential dissolution of L1{sub 2} compared to (L1{sub 2} + Ni{sub ss}) mixture region at lower pH, while pitting attack occurred in (L1{sub 2} + Ni{sub ss}) mixture region at neutral solution. For both intermetallic compounds, the magnitude of pitting and uniform attack decrease with increasing pH of solutions. From the immersion test and polarization curves, the corrosion resistance of Ni{sub 3}(Si,Ti)+2Mo is lower than that of Ni{sub 3}(Si,Ti), while the nickel alloy C-276 is the highest one at various pH of solutions. On the other hand, in the lower pH of solutions, the corrosion resistance of tested materials decreased significantly compared to those in neutral and higher pH of solutions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of Carbon Nanotube Concentration on the Corrosion Behavior of Electroless Ni-B-CNT Coating

In this study, Ni-B-CNT composite was deposited on AISI 4140 steel using different concentrations of CNTs ranging from 0.2 to 1 gr/lit in an electroless bath. The phase analysis and surface morphology of the samples were characterized using x-ray diffraction and FESEM. The corrosion behavior of the coated samples was investigated in a 3.5 wt.% NaCl solution through potentiodynamic polarization, EIS, and electrochemical noise (EN) analyses. The corroded surface of the samples was further analyzed via FESEM observation after 10 days of immersion in corrosive medium. It was found that although adding 0.2 gr/lit CNT in electroless solution improves corrosion resistance, increasing CNT concentration from 0.2 up to 1 gr/lit increases the corrosion rate. The FESEM observations and EN results imply that the formation of micro-galvanic cells in samples with high concentration of CNTs leads to nucleation and growth of the pits. The results revealed that no passive layer was formed on the surface of the Ni-B sample, and the corrosion occurred through ionic diffusion into the cracks and crevices. The results of potentiodynamic test show that adding CNTs into electroless bath facilitates the formation of passive layer. However, results of EN test imply that increasing CNT concentration causes repetitive breakdown and recovery of passive film.

36 MATERIALS SCIENCE↗

IDENTIFYING IMPURITIES IN SURPLUS NON PIT PLUTONIUM FEEDS FOR MOX OR ALTERNATIVE DISPOSITION

This report provides a technical basis for estimating the level of corrosion products in materials stored in DOE-STD-3013 containers based on extrapolating available chemical sample results. The primary focus is to estimate the levels of nickel, iron, and chromium impurities in plutonium-bearing materials identified for disposition in the United States Mixed Oxide fuel process.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effects of Chloride and Carbonate on Corrosion of API-X100 Pipeline Steel

Effects of chloride, introduced with 0.03, 0.05, 0.10, 0.12, 0.22, 0.25 M, on the corrosion behavior of API-X100 pipeline steel in 0.15 M carbonate solutions were studied. The evaluations were carried out with monitoring the open-circuit potentials and electrochemical impedance spectroscopy (EIS). The open-circuit potentials gave an electrochemical evidence on the weakening opposite kinetics of the passive film formation to the kinetics of dissolution with higher chloride concentrations. The open-circuit potentials were less with higher chloride concentrations. The EIS tests indicated that the corrosion resistance decreased, and species diffusion increased with the chloride concentration, in multi-time constant interactions. In all tests, slippery transparent films formed with no presence of pitting on the sample surfaces.

36 MATERIALS SCIENCE↗

Tank Inspection NDE Results for Waste Tanks 25, 26, 33, 34, 41 and 50 (FY2019)

In-service inspection is an essential element of a comprehensive structural integrity program for the carbon steel waste tanks at the Savannah River Site. Inspection confirms the effectiveness of corrosion controls used to preclude localized and general corrosion of the tanks. Ultrasonic inspection (UT) is used to detect general wall thinning, pitting and interface attack, as well as vertically oriented cracks through inspection of an 8.5 inch wide strip extending over the accessible height of the primary tank wall and knuckle regions. selected welds are also inspected for cracking parallel or perpendicular to the weld. The inspections were performed from the annular space of the Type III/IIIA waste storage tanks. The ISI Program calls for thickness mapping and crack detection scans on specified areas of the tank covering all present and historic waste interface levels and selected welds with particular emphasis on the highest stress region of the tank.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Accelerated corrosion testing of cold spray coatings on 304L in chloride environments

Cold spray is an advanced metal manufacturing technique applied across many fields for a wide range of functions. Low heat input and compressive stresses induced into the substrate by the cold spray process makes it a promising choice for protective corrosion resistant coatings. One potential application for cold spray is as a protective coating against corrosion for spent nuclear fuel (SNF) interim dry storage canisters. As these canisters are currently stored at interim storage locations longer than originally intended, chloride induced stress corrosion cracking has been identified as a high priority knowledge gap, specifically with respect to prolonging or extending canister lifetimes ( Teague et al., 2019 ). The high deployability of cold spray, for which nozzles have been developed for application in constrained spaces, in conjunction with beneficial properties inherent to cold spray makes this a good candidate for a corrosion protection coating on SNF canisters. This work explores a pathway to rapidly down-select cold spray coatings for canisters by focusing on the corrosion properties. Specifically, this study examines the corrosion protection abilities of nickel and nickel-based alloy cold spray coatings on 304 L stainless steel in chloride rich environments through electrochemical scans and ferric chloride pitting tests (ASTM G48 Method A). It was shown that the porosity of the coating, the processing gas, material selection, and deformation in the substrate all impact the corrosion behavior of cold spray coatings and are areas where optimization could reduce potential materials degradation, enabling enhanced coatings development.

Karasz, Erin K.↗

Progress in Understanding the Origins of Excellent Corrosion Resistance in Metallic Alloys: From Binary Polycrystalline Alloys to Metallic Glasses and High Entropy Alloys

Some of the factors responsible for good corrosion resistance of select polycrystalline and emerging alloys in chloride solutions are discussed with a goal of providing some perspectives on the current status and future directions. Traditional metallic glass alloys, single phase high entropy alloys (HEAs), early metallic glasses, and high entropy metallic glasses are all emerging corrosion-resistant alloys (CRAs) that utilize traditional strategies for improved corrosion resistance as well as take advantage of some other novel beneficial attributes. These materials enjoy many degrees of freedom as far as choice of both composition and structure, providing great flexibility in the pursuit of superior corrosion resistance. The new materials depart from classical solvent-solute type polycrystalline binary or ternary alloys. Thus, such emerging materials provide significant opportunities to achieve even greater improvements in corrosion resistance in harsh environments. Several examples of the unique corrosion properties of selected materials in the context of modern theories of corrosion are discussed herein. Discussion is restricted to solid-solution binary or ternary polycrystalline alloys, several metallic glass alloys, and single phase HEAs. A common feature of many CRAs is that composition and microstructure often affect both passivity and resistance to localized corrosion that can be divided into initiation, stabilization, and propagation stages. Enormous complexities in protective oxide structures and chemistries and the large number of combinatorial possibilities in newer materials such as HEAs preclude trial-and-error approaches and perhaps even combinatorial experimental design. Computational materials methodologies will be required in the search for new corrosion-resistant alloys in these material classes. The search must consider the best scientific insights available regarding how major and minor alloy additions, as well as various microstructural attributes, contribute to corrosion mitigation. Additional scientific insights, as they emerge, will enable choices beyond the reliance on high concentrations of alloying elements that are known to affect passivity breakdown and pit stabilization. A challenge is to connect the “basic attributes” of an alloy with its properties. The strength of this connection will likely require new scientific principles enabling deep multiphysics insights in order to link feature(s) such as composition and metallurgical phases to the desired corrosion properties. Application of data informatics will likely also play a role given the plethora of variables that are important in corrosion and the difficulty in assessing all relationships. Here, the opportunity exists to accelerate the design of emerging materials for high corrosion resistance.

36 MATERIALS SCIENCE↗

Microstructural Characterization and Electrochemical Behavior of AA2014 Al-Cu-Mg-Si Alloy of Various Tempers

AA2014 Al-Cu-Mg-Si alloy is subjected to aging heat treatment, and microstructural features and electrochemical behavior of the AA2014 Al-Cu-Mg-Si alloy of various tempers have been characterized. Hardness measurement of the alloy of different tempers showed typical age hardening behavior. X-ray diffraction and transmission electron microscopy studies revealed the presence of characteristic phases. Differential scanning calorimetry study displayed the sequence of solid-state precipitation and dissolution reactions in the AA2014 alloy of various tempers. Electrochemical behavior was assessed by measurement of variation of open-circuit voltage with time, potentiodynamic polarization and potentiodynamic cyclic polarization of the AA2014 alloy of various tempers in 3.5 wt.% NaCl solution at near neural (pH ~ 7) and at alkaline (pH 12) conditions. Potentiodynamic polarization studies of different tempers in 3.5 wt.% NaCl solution at pH ~ 7 showed that the corrosion potential (E{sub corr}) value has shifted toward more negative (active) direction with increasing aging time. The cyclic polarization in 3.5 wt.% NaCl solution at pH ~ 7 displayed active–passive behavior and also showed a large hysteresis loop indicating high pit growth damage.

36 MATERIALS SCIENCE↗

Assessment of Microbiologically Influenced Corrosion Potential in the International Space Station Internal Active Thermal Control System Heat Exchanger Materials: A 6-Momths Study

The fluid in the Internal Active Thermal Control System (IATCS) of the International Space Station (ISS) is water based. The fluid in the ISS Laboratory Module and Node 1 initially contained a mix of water, phosphate (corrosion control), borate (pH buffer), and silver sulfate (Ag2SO4) (microbial control) at a pH of 9.5+/-0.5. Over time, the chemistry of the fluid changed. Fluid changes included a pH drop from 9.5 to 8.3 due to diffusion of carbon dioxide (CO2) through Teflon(reistered Trademark) (DuPont) hoses, increases in dissolved nickel (Ni) levels, deposition of silver (Ag) to metal surfaces, and precipitation of the phosphate (PO4) as nickel phosphate (NiPO4). The drop in pH and unavailability of a antimicrobial has provided an environment conducive to microbial growth. Microbial levels in the fluid have increased from >10 colony-forming units (CFUs)/100 ml to 10(exp 6) CFUs/100 ml. The heat exchangers in the IATCS loops are considered the weakest point in the loop because of the material thickness (=7 mil). It is made of a Ni-based braze filler/CRES 347. Results of a preliminary test performed at Hamilton Sundstrand indicated the possibility of pitting on this material at locations where Ag deposits were found. Later, tests have confirmed that chemical corrosion of the materials is a concern for this system. Accumulation of micro-organisms on surfaces (biofilm) can also result in material degradation and can amplify the damage caused by the chemical corrosion, known as microbiologically influenced corrosion (MIC). This paper will discuss the results of a 6-mo test performed to characterize and quantify the damage from microbial accumulation on the surface of the ISS/ATCS heat exchanger materials. The test was designed to quantify the damage to the materials under worst-case conditions with and without micro-organisms present at pH 8.3 and 9.5.

Roman, Monsi C.↗

Corrosion Behavior of 316L Stainless Steel Fabricated by Selective Laser Melting Under Different Scanning Speeds

This work discussed the effects of different scanning speeds (800, 1083, 1200 and 1400 mm/s) on the microstructure of 316L stainless steel manufactured by selective laser melting (SLM) and the related corrosion behavior. Results showed that there were more voids with faster scanning speeds, and there were oxide powder and non-melt silicon inside the defects. The SLM 316L exhibited a full gamma austenite phase filled with sub-grains, and the average grain size of SLM-1083 mm/s 316L was approximately 42 μm, three times larger than that of the quenched 316L. The pitting potentials for the SLM 316L were all approximately 300 mV higher than that of the quenched due to the modification of inclusions in SLM, but the corrosion rate for the SLM 316L was faster, which was attributed to the voids and unstable passive film. The number of pitting sites increased with the scanning speed, and the pits occurred preferentially at the voids in SLM 316L.

36 MATERIALS SCIENCE↗

Influence of carbon nanotubes on microstructure and corrosion performance of additively manufactured 316L stainless steel

For this study, laser powder bed fusion (LPBF) was performed on feedstock-modified 316L stainless steel powder with 1 and 2 vol% carbon nanotubes (CNT). The corrosion resistance was evaluated following cyclic potentiodynamic polarization tests conducted in 0.6 M NaCl at room temperature, 35 and 50 °C, and immersion tests in 6 % FeCl 3 . The CNT addition has increased the pitting potential and decreased number of pits formed during immersion in FeCl 3 solution, which could be attributed to Mn-Si-O nano inclusions refinement and segregation of chromium around the inclusions. The observed corrosion behavior was correlated with the altered microstructure due to CNT addition.

36 MATERIALS SCIENCE↗

Tank Inspection NDE Results for Fiscal Year 2014, Waste Tanks 26, 27, 28 and 33

Ultrasonic nondestructive examinations (NDE) were performed on waste storage tanks 26, 27, 28 and 33 at the Savannah River Site as a part of the “In-Service Inspection (ISI) Program for High Level Waste Tanks.” No reportable conditions were identified during these inspections. The results indicate that the implemented corrosion control program continues to effectively mitigate corrosion in the SRS waste tanks. Ultrasonic inspection (UT) is used to detect general wall thinning, pitting and interface attack, as well as vertically oriented cracks through inspection of an 8.5 inch wide strip extending over the accessible height of the primary tank wall and accessible knuckle regions. Welds were also inspected in tanks 27, 28 and 33 with no reportable indications. In a Type III/IIIA primary tank, a complete vertical strip includes scans of five plates (including knuckles) so five “plate/strips” would be completed at each vertical strip location. In FY 2014, a combined total of 79 plate/strips were examined for thickness mapping and crack detection, equating to over 45,000 square inches of area inspected on the primary tank wall. Of the 79 plate/strips examined in FY 2014 all but three have average thicknesses that remain at or above the construction minimum thickness which is nominal thickness minus 0.010 inches. There were no service induced reportable thicknesses or cracking encountered. A total of 2 pits were documented in 2014 with the deepest being 0.032 inches deep. One pit was detected in Tank 27 and one in Tank 33. No pitting was identified in Tanks 26 or 28. The maximum depth of any pit encountered in FY 2014 is 5% of nominal thickness, which is less than the minimum reportable criteria of 25% through-wall for pitting. In Tank 26 two vertical strips were inspected, as required by the ISI Program, due to tank conditions being outside normal chemistry controls for more than 3 months. Tank 28 had an area of localized thinning on the exterior wall of the secondary tank noted during the initial inspections in 2005. That area was inspected again in 2014 and found to be larger and slightly deeper. The deepest area of thinning in the secondary wall is less than 20% wall loss. The maximum length of thinning is less than 24 inches and does not impact structural or leak integrity per WSRC-TR-2002-00063. Inspection results were presented to the In-service Inspection Review Committee (ISIRC) where it was determined that no additional data was required to complete these inspections.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Accelerated Corrosion Tests to Evaluate Long-Term Performance of BORAL{sup R} in Spent Fuel Pools

Neutron absorber materials are used to increase storage capacity in spent fuel pools (SFPs) while maintaining criticality safety margins. BORAL{sup R} - a neutron absorber material commonly used in SFPs - is a metal matrix composite containing boron carbide (B{sub 4}C) and Al-1100 mixture. The aluminum (Al) cladding, which is on both sides of the core, serves as a protective barrier. Al cladding is susceptible to corrosion, which can lead to blisters between the core material and the cladding over time. Based on operational experience to date, pits also have been observed via visual examination and microscopy. EPRI has maintained a database containing coupon data spanning more than 25 years, and to date no loss of BORAL{sup R} efficacy has been observed. In the United States, about 50% of the plants use BORAL{sup R} as neutron absorber material in SFPs. BORAL{sup R} is also used in nuclear plants in Mexico, Korea, Taiwan, and other countries. Given that the plant lifetime is increasing-and, hence, the SFP lifetime-EPRI initiated a five-year accelerated corrosion test in 2013 to evaluate and determine the long-term performance of BORAL{sup R} in SFPs. This paper presents an overview of the accelerated corrosion test project. Results from the Year 1 and Year 2 test results are also presented. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Use of cyclic current reversal polarization voltammetry for investigating the relationship between corrosion resistance and heat-treatment induced variations in microstructures of 400 C martensitic stainless steels

Software for running a cyclic current reversal polarization voltammagram has been developed for use with a EG&G Princeton Applied Research Model 273 potentiostat/galvanostat system. The program, which controls the magnitude, direction and duration of an impressed galvanostatic current, will produce data in ASCII spreadsheets (Lotus, Quattro) for graphical representation of CCRPV voltammograms. The program was used to determine differences in corrosion resistance of 440 C martenstic stainless steel produced as a result of changes in microstructure effected by tempering. It was determined that tempering at all temperatures above 400 F resulted in increased polarizability of the material, with the increased likelihood that pitting would be initiated upon exposure to marine environments. These results will be used in development of remedial procedures for lowering the susceptibility of these alloys toward the stress corrosion cracking experienced in bearings used in high pressure oxygen turbopumps used in the main engines of space shuttle orbiters.

Ambrose, John R.↗

Electrochemical Impedance Spectroscopy of Alloys in a Simulated Space Shuttle Launch Environment

Corrosion studies began at NASA/Kennedy Space Center in 1966 during the Gemini/Apollo Programs with the evaluation of long-term protective coatings for the atmospheric protection of carbon steel. An outdoor exposure facility on the beach near the launch pad was established for this purpose at that time. The site has provided over 35 years of technical information on the evaluation of the long-term corrosion performance of many materials and coatings as well as on maintenance procedures. Results from these evaluations have helped NASA find new materials and processes that increase the safety and reliability of our flight hardware, launch structures, and ground support equipment. The launch environment at the Kennedy Space Center (KSC) is extremely corrosive due to the combination of ocean salt spray, heat, humidity, and sunlight. With the introduction of the Space Shuttle in 1981, the already highly corrosive conditions at the launch pad were rendered even more severe by the acidic exhaust from the solid rocket boosters. Over the years, many materials have been evaluated for their corrosion performance under conditions similar to those found at the launch pads. These studies have typically included atmospheric exposure and evaluation with conventional electrochemical methods such as open circuit potential (OCP) measurements, polarization techniques, and electrochemical impedance spectroscopy (EIS). The atmosphere at the Space Shuttle launch site is aggressive to most metals and causes severe pitting in many of the common stainless steel alloys such as type 304L stainless steel (304L SS). A study was undertaken to find a more corrosion resistant material to replace the existing 304L SS tubing. This paper presents the results from atmospheric exposure as well as electrochemical measurements on the corrosion resistance of AL-6XN (UNS N08367) and 254-SMO (UNS S32154). Type 304L SS (UNS S30403) was used as a control. Conditions at the Space Shuttle launch pad were simulated by using a hydrochloric acid (HC1) and alumina (Al203) slurry rinse for the atmospheric exposure and an electrolyte consisting of 3.55% sodium chloride (NaC1) with increased concentrations of hydrochloric acid (HC1) for the electrochemical measurements. The results from both types of measurements revealed the superior corrosion performance of the higher-alloyed materials. Unlike 304L SS, 254-SMO and AL-6XN exhibited a significantly improved resistance to corrosion as the concentration of hydrochloric acid in he 3.55% NaCl electrolyte solution was increased.

Calle, L. M.↗