Search NASA⌕ Search

SEARCH · Search NASA

Results for “POTABLE WATER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Advanced collapsible tank for liquid containment

Tanks for bulk liquid containment will be required to support advanced planetary exploration programs. Potential applications include storage of potable, process, and waste water, and fuels and process chemicals. The launch mass and volume penalties inherent in rigid tanks suggest that collapsible tanks may be more efficient. Collapsible tanks are made of lightweight flexible material and can be folded compactly for storage and transport. Although collapsible tanks for terrestrial use are widely available, a new design was developed that has significantly less mass and bulk than existing models. Modelled after the shape of a sessible drop, this design features a dual membrane with a nearly uniform stress distribution and a low surface-to-volume ratio. It can be adapted to store a variety of liquids in nearly any environment with constant acceleration field. Three models of 10L, 50L, and 378L capacity have been constructed and tested. The 378L (100 gallon) model weighed less than 10 percent of a commercially available collapsible tank of equivalent capacity, and required less than 20 percent of the storage space when folded for transport.

Flanagan, David T.↗

Characterization of Electrochemically Generated Silver

Silver biocide offers a potential advantage over iodine, the current state of the art in US spacecraft disinfection technology, in that silver can be safely consumed by the crew. Low concentrations of silver (<500 ppb) have been shown to kill bacteria in water systems and keep it safe for potability. Silver does not require hardware to remove it from a water system, and therefore can provide a simpler means for disinfecting water. The Russian segment of the International Space Station has utilized an electrochemically generated silver solution, which is colloidal in nature. To be able to reliably provide a silver biocide to drinking water by electrochemical means would reduce mass required for removing another biocide such as iodine from the water. This would also aid in crew time required to replace iodine removal cartridges. Future long term missions would benefit from electrochemically produced silver as the biocide could be produced on demand and requires only a small concentration to be effective. Since it can also be consumed safely, there is less mass in removal hardware and little consumables required for production. The goal of this project initially is to understand the nature of the electrochemically produced silver, the particle sizes produced by the electrochemical cell and the effect that voltage adjustment has on the particle size. In literature, it has been documented that dissolved oxygen and pH have an effect on the ionization of the electrochemical silver so those parameters would be measured and possibly adjusted to understand their effect on the silver.

Adam, Niklas↗

Development Status of the International Space Station Urine Processor Assembly

NASA, Marshall Space Flight Center (MSFC) is developing a Urine Processor Assembly (UPA) for the International Space Station (ISS). The UPA uses Vapor Compression Distillation (VCD) technology to reclaim water from pre-treated urine. This water is further processed by the Water Processor Assembly (WPA) to potable quality standards for use on the ISS. NASA has developed this technology over the last 25-30 years. Over this history, many technical issues were solved with thousands of hours of ground testing that demonstrate the ability of the UPA technology to reclaim water from urine. In recent years, NASA MSFC has been responsible for taking the UPA technology to "flight design" maturity. This paper will give a brief overview of the UPA design and a status of the major design and development efforts completed recently to mature the UPA to a flight level.

Holder, Donald W.↗

Filtering Water by Use of Ultrasonically Vibrated Nanotubes

Devices that could be characterized as acoustically driven molecular sieves have been proposed for filtering water to remove all biological contaminants and all molecules larger than water molecules. Originally intended for purifying wastewater for reuse aboard spacecraft, these devices could also be attractive for use on Earth in numerous settings in which there are requirements to obtain potable, medical-grade, or otherwise pure water from contaminated water supplies. These devices could also serve as efficient means of removing some or all water from chemical products . for example, they might be useful as adjuncts or substitutes for stills in the removal of water from alcohols and alcoholic beverages. These devices may be constructed using various materials, such as ceramics, metallics, or polymers, depending on end-use requirements. A representative device of this type (see figure) would include a polymeric disk, about 1 mm in diameter and between 1 and 40 microns thick, within which would be embedded single-wall carbon nanotubes aligned along the thickness axis. The polymeric disk would be part of a unitary polymeric ring assembly. An acoustic transducer in the form of a piezoelectric-film-and-electrode subassembly - typically 9 microns thick and made of poly(vinylidene fluoride) coated with copper 150 nm thick -. would be affixed to the outside of the outer polymeric ring by means of an electrically nonconductive epoxy. The nanotubes would be chosen to have diameters between about 8 and about 13.5 A because water molecules could fit into the nanotubes, but larger molecules could not. Water to be purified would be placed in contact with one face (typically, the upper face) of the filter disk. The surface tension of water is low enough that water molecules should enter and travel along the nanotubes, and computational simulations of molecular dynamics and experimental measurements have shown that the water molecules inside the nanotubes in this size range can be expected to become aligned into helical columns that exhibit properties of both hexagonal ice crystals and liquid water

Gavalas, Lillian Susan↗

Advance prototype silver ion water bactericide system

An advance prototype unit was designed and fabricated to treat anticipated fuel cell water. The unit is a single canister that contains a membrane-type prefilter and a silver bromide contacting bed. A seven day baseline simulated mission test was performed; the performance was satisfactory and the effluent water was within all specifications for potability. After random vibrations another seven day simulated mission test was performed, and results indicate that simulated launch vibrations have no effects on the design and performance of the advanced prototype. Bench tests and accelerated breadboard tests were conducted to define the characteristics of an upgraded model of the advance prototype unit which would have 30 days of operating capability. A preliminary design of a silver ion generator for the shuttle orbiter was also prepared.

Jasionowski, W. J.↗

A hybrid regenerative water recovery system for lunar/Mars life support applications

Long-duration manned space missions will require integrated biological and physicochemical processes for recovery of resources from wastes. This paper discusses a hybrid regenerative biological and physicochemical water recovery system designed and built at NASA's Crew and Thermal Systems Division at Johnson Space Center. The system is sized for a four-person crew and consists of a two-stage, aerobic, trickling filter bioreactor; a reverse osmosis system; and a photocatalytic oxidation system. The system was designed to accommodate high organic and inorganic loadings and a low hydraulic loading. The bioreactor was designed to oxidize organics to carbon dioxide and water; the reverse osmosis system reduces inorganic content to potable quality; and the photocatalytic oxidation unit removes residual organic impurities (part per million range) and provides in situ disinfection. The design and performance of the hybrid system for producing potable/hygiene water is described. Aspects of the system such as closure, automation and integration are discussed and preliminary results presented.

Verostko, Charles E.↗

Catalytic methods using molecular oxygen for treatment of PMMS and ECLSS waste streams, volume 2

Catalytic oxidation has proven to be an effective addition to the baseline sorption, ion exchange water reclamation technology which will be used on Space Station Freedom (SSF). Low molecular weight, polar organics such as alcohols, aldehydes, ketones, amides, and thiocarbamides which are poorly removed by the baseline multifiltration (MF) technology can be oxidized to carbon dioxide at low temperature (121 C). The catalytic oxidation process by itself can reduce the Total Organic Carbon (TOC) to below 500 ppb for solutions designed to model these waste waters. Individual challenges by selected contaminants have shown only moderate selectivity towards particular organic species. The combined technology is applicable to the more complex waste water generated in the Process Materials Management System (PMMS) and Environmental Control and Life Support System (ECLSS) aboard SSF. During the phase 3 Core Module Integrated Facility (CMIF) water recovery tests at NASA MSFC, real hygiene waste water and humidity condensate were processed to meet potable specifications by the combined technology. A kinetic study of catalytic oxidation demonstrates that the Langmuir-Hinshelwood rate equation for heterogeneous catalysts accurately represent the kinetic behavior. From this relationship, activation energy and rate constants for acetone were determined.

Akse, James R.↗

Seeding Advanced Treated Wastewater for Purposes of Direct Potable Reuse

Direct potable reuse (DPR) is a promising solution to address water scarcity. However, a better understanding of how introducing advanced treated water (ATW) affects microbial communities present in distribution systems is needed. Here, in this study, we measured changes to the microbial water quality in simulated distribution systems that were conditioned using treated, unimpaired surface water (SW) and then transitioned to ATW. In addition, we investigated whether adding a biological filtration step would seed the microbial community of the ATW and whether the influence would persist in the simulated distribution systems. We found that the bulk water in the ATW-fed distribution systems had lower cell counts and ATP concentrations and a distinct microbial community (based on 16S amplicon sequencing) compared to the SW-fed or the seeded ATW-fed systems. However, biofilm community composition and biomass remained consistent regardless of the feedwater. Increased microbial biomass and diversity were present in the seeded ATW, with several amplicon sequence variants identified as being introduced by the biological filter. Our results suggest that directly introducing ATW to distribution systems could disturb the existing microbial community. Preparing ATW for distribution via biological filtration may deliver more predictable and stable microbial water quality than introducing unseeded ATW.

16S↗

Development of a laboratory prototype water quality monitoring system suitable for use in zero gravity

The development of a laboratory prototype water quality monitoring system for use in the evaluation of candidate water recovery systems and for study of techniques for measuring potability parameters is reported. Sensing techniques for monitoring of the most desirable parameters are reviewed in terms of their sensitivities and complexities, and their recommendations for sensing techniques are presented. Rationale for selection of those parameters to be monitored (pH, specific conductivity, Cr(+6), I2, total carbon, and bacteria) in a next generation water monitor is presented along with an estimate of flight system specifications. A master water monitor development schedule is included.

Misselhorn, J. E.↗

Cost and Energy Metrics for Municipal Water Reuse

Municipal water reuse can contribute to a circular water economy in different contexts and with various treatment trains. This study synthesized information regarding the current technological and regulatory statuses of municipal reuse. It provides process-level information on cost and energy metrics for three potable reuse and one nonpotable reuse case studies using the new Water Techno-economic Assessment Pipe-Parity Platform (WaterTAP3). WaterTAP3 enabled comparisons of cost and energy metrics for different treatment trains and for different alternative water sources consistently with a common platform. A carbon-based treatment train has both a lower calculated levelized cost of water (LCOW) ($0.40/m3) and electricity intensity (0.30 kWh/m3) than a reverse osmosis (RO)-based treatment train ($0.54/m3 and 0.84 kWh/m3). In comparing LCOW and energy intensity for water production from municipal reuse, brackish water, and seawater based on the largest facilities of each type in the United States, municipal reuse had a lower LCOW and electricity than seawater but higher values than for production from brackish water. For a small (2.0 million gallon per day) inland RO-based municipal reuse facility, WaterTAP3 evaluated different deep well injection and zero liquid discharge (ZLD) scenarios for management of RO concentrate. Adding ZLD to a facility that currently allows surface discharge of concentrate would approximately double the LCOW. For all four case studies, LCOW is most sensitive to changes in weighted average cost of capital, on-stream capacity, and plant life. Baseline assessments, pipe parity metrics, and scenario analyses can inform greater observability and understanding of reuse adoption and the potential for cost-effective and energy-efficient reuse.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Integrated Anaerobic Membrane Bioreactor (AnMBR) – electro assisted fermentation platform for total resource recovery from diverse wastewaters

The overall objective of the project was to demonstrate a successful wastewater resource recovery platform comprising an Anaerobic Membrane Bioreactor (AnMBR) to achieve >50% Carbon sequestration efficiency as Volatile Fatty Acids (VFAs) or as methane gas from agricultural (animal feeding operations) wastewater along with the generation of final water exceeding Biological Nutrient Removal (BNR) standards for indirect potable reuse by coupling with constructed wetlands has been successfully accomplished. The AnMBR achieved stable performance over 350 days, removing 80–90% of COD and BOD₅ and recovering methane (0.17±0.07 L CH4/g COD at 66.5±0.03% v/v) at 3-5 LMH flux and 5-9 days HRT with 3-5% w/v total solids. Phosphorus recovery via CaO addition in an 80-L coagulation-flocculation-sedimentation unit ranged from 40.6% to 99.7%, yielding products with 11.4–13.6% P content and citric acid solubility of 32–38.6% P, comparable to rock phosphate mineral. Ammonium adsorption achieved ~94.5% recovery with exchange capacity of 10 – 16 g NH4-N/kg clinoptilolite. The CW polishing step met Kansas discharge standards for BOD5 and TN (<30 and <10 mg /L,) and approached the TP standard (~2.5 – 4 mg P/L). These findings have either already resulted in two peer reviewed publications, two patent applications, and one publication in conference proceedings.

42 ENGINEERING↗

International Space Station environmental control and life support system. Phase 3: Water Recovery Test Stage 9

A test has been completed at NASA's Marshall Space Flight Center (MSFC) to evaluate the latest water recovery system design for the United States On-Orbit Segment (USOS) of the International Space Station (ISS) with higher fidelity hardware and integration than has been achieved in previous Water Recovery Test (WRT) Stages. This test is referred to as WRT Stage 9. Potable and urine processing assemblies were integrated with end-use equipment and operated for 116 days. The overall integrated configuration of the test system included a single water recovery loop that was automated and controlled from a central computer. This report summarizes the test objectives, system design, test activities and protocols, significant results, anomalies and lessons learned throughout the WRT Stage 9.

D L Carter↗

Southwest Regional Partnership on Carbon Sequestration (Phase III) Underground Source of Drinking Water Monitoring at the Farnsworth Unit

The Ogallala aquifer is identified as the only underground source of drinking water (USDW) aquifer in the vicinity of the FWU. Throughout the span of the SWP project at the FWU, groundwater samples from the Ogallala Aquifer were collected and analyzed on a regular basis to obtain information that reflects the water quality baseline and any potential leakage, and to facilitate effective simulations and risk assessment. To date, hundreds of samples have been collected and tested. The water analysis results suggest that the Ogallala groundwater quality maintains stable and potable, and no leakage is indicated by these data.

42 ENGINEERING↗

Feasibility of Recycling Discharged Microreactor Heavy Metal in Light Water and Sodium-Cooled Fast Reactors: A Neutronics Analysis

Nuclear microreactors (MRs) offer unique advantages, such as rapid deployment, potability, low maintenance requirements, and operational flexibility. Their compact size makes them a promising solution for decentralized power generation, particularly in remote areas, military bases, and disaster-stricken regions. However, MRs face challenges, including unutilized fissile material at the end of life, economic inefficiency, increased heavy metal (HM) waste complicating disposal, and the accumulation of plutonium (Pu) with high 239 Pu concentrations raising proliferation risks. Here, this study investigated the neutronics feasibility of a novel three-stage fuel cycle where discharged HM from MRs is recycled and burned in light water reactors and sodium-cooled fast reactors. This approach converts discharged HM into valuable fuel, enhancing the efficiency of MR deployments while improving the safeguardability of their final waste products. Neutronics analysis demonstrated that the safety characteristics of reactor designs in each stage were minimally impacted by the proposed cycle. For two representative MR designs, a fast-spectrum MR with solid pellet fuel and a thermal-spectrum MR with TRISO (TRi-structural-ISOtropic) fuel compacts, the proposed fuel cycle reduced the uranium disposal mass flow rate by ~60%, decreased the 235 U enrichment of the discharge fuel to ~1 wt%, eliminated plutonium disposal, and increased the cumulative fuel burnup to ~580 gigawatt-day per metric ton of initial heavy metal (GWd/t-iHM) or 60% fissions per initial metal atom. Despite the significant differences between the two MR designs, the performance and infrastructure requirements of the developed fuel cycles were remarkably similar, indicating its generalizability to a broader class of MRs.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Results of the Alternative Water Processor Test, A Novel Technology for Exploration Wastewater Remediation

Biologically-based water recovery systems are a regenerative, low energy alternative to physiochemical processes to reclaim water from wastewater. This report summarizes the results of the Alternative Water Processor (AWP) Integrated Test, conducted from June 2013 until April 2014. The system was comprised of four (4) membrane aerated bioreactors (MABRs) to remove carbon and nitrogen from an exploration mission wastewater and a coupled forward and reverse osmosis system to remove large organic and inorganic salts from the biological system effluent. The system exceeded the overall objectives of the test by recovering 90% of the influent wastewater processed into a near potable state and a 64% reduction of consumables from the current state of the art water recovery system on the International Space Station (ISS). However, the biological system fell short of its test goals, failing to remove 75% and 90% of the influent ammonium and organic carbon, respectively. Despite not meeting its test goals, the BWP demonstrated the feasibility of an attached-growth biological system for simultaneous nitrification and denitrification, an innovative, volume- and consumable-saving design that does not require toxic pretreatment.

Meyer, Caitlin E.↗

Predicting initial trans-membrane pressure across cycles in the ultrafiltration process using random forest

With growing freshwater scarcity, direct potable reuse (DPR) systems that reclaim wastewater for drinking are becoming increasingly important for sustainable water supply. Reliable operation requires minimizing downtime in ultrafiltration (UF) units, where membrane fouling leads to elevated trans-membrane pressure (TMP). This study develops data-driven regression models based on random forest (RF) and autoregressive (AR) approaches to forecast the initial TMP at the start of each UF filtration cycle in a pilot-scale DPR system. The RF model consistently outperforms baseline methods, including historical mean, last observation carried forward, and AR models, across multiple forecast horizons, achieving the lowest root mean square error. To evaluate how different classes of process variables contribute to TMP dynamics over time, we examine the feature importance of independent input variables across multiple forecast horizons. This analysis provides insight into the temporal relevance of operational and sensor-derived features, guiding control and monitoring strategies. Additionally, the impact of hyperparameter tuning on TMP prediction performance is assessed for both direct and recursive RF modelling approaches. The proposed RF framework establishes a robust foundation for predictive monitoring and real-time optimization of UF operations, supporting sustainable and reliable water reuse.

direct potable reuse↗

Long-Term Statistical Process Monitoring of an Ultrafiltration Water Treatment Process

As water treatment technology has improved, the amount of available process data has substantially increased, making real-time, data-driven fault detection a reality. One shortcoming of the fault detection literature is that methods are usually evaluated by comparing their performance on hand-picked, short-term case studies, which yields no insight into long-term performance. In this work, we first evaluate multiple statistical and machine learning approaches for detrending process data. Then, we evaluate the performance of a PCA-based fault detection approach, applied to the detrended data, to monitor influent water quality, filtrate quality, and membrane fouling of an ultrafiltration membrane system for indirect potable reuse. Based on two short case studies, the adaptive lasso detrending method is selected, and the performance of the multivariate approach is evaluated over more than a year. The method is tested for different sets of three critical tuning parameters, and we find that for long-term, autonomous monitoring to be successful, these parameters should be carefully evaluated. However, in comparison with industry standards of simpler, univariate monitoring or daily pressure decay tests, multivariate monitoring produces substantial benefits in long-term testing.

ammonia↗

Alpha Spectrometry Results for Groundwater Samples Collected in Northern Iraq and a Summary of the Environmental Setting of the Adaya Burial Site

The Radiation Protection Center (RPC) of the Iraqi Ministry of Environment continues to evaluate the potential health impacts associated with the Adaya Burial Site, which is located 33 kilometers (20.5 miles) southwest of Mosul. This report documents the radiological analyses of 16 groundwater samples collected from wells located in the vicinity of the Adaya Burial Site and at other sites in northern Iraq. The Adaya Burial Site is a high-risk dump site because a large volume of radioactive material and contaminated soil is located on an unsecure hillside above the village of Tall ar Ragrag. The uranium activities for the 16 water samples in northern Iraq are considered to be naturally occurring and do not indicate artificial (man-made) contamination. With one exception, the alpha spectrometry results for the 16 wells that were sampled in 2019 indicate that the water quality concerning the three uranium isotopes (Uranium-233/234, Uranium-235/236, and Uranium-238) was acceptable for potable purposes (drinking and cooking). However, Well 7 in Mosul had a Uranium-233/234 activity concentration that slightly exceeded the World Health Organization guidance level. Eight of the 16 wells are located in the villages of Tall ar Ragrag and Adaya and had naturally occurring uranium concentrations. Wells in the villages of Tall ar Ragrag and Adaya are located near the Adaya Burial Site and should be sampled on an annual schedule. The list of groundwater analytes should include metals, total uranium, isotopic uranium, gross alpha/beta, gamma spectroscopy, organic compounds, and standard water quality parameters. Our current understanding of the hydrogeologic setting in the vicinity of the Adaya Burial Site is solely based on villager's domestic wells, topographic maps, and satellite imagery. To better understand the hydrogeologic setting, a Groundwater Monitoring Program needs to be developed and should include the installation of twelve groundwater monitoring wells in the vicinity of Tall ar Ragrag and the Adaya Burial Site. Characterization of the limestone aquifer and overlying alluvium is needed. RPC should continue to support health assessments for the villagers in Tall ar Ragrag and Adaya. Collecting samples for surface water (storm water), airborne dust, vegetation, and washway sediment should be conducted on a routine basis. Human access to the Adaya Burial Site needs to be strictly limited. Livestock access on or near the burial site needs to be eliminated. The surface-water exposure pathway is likely a greater threat than the groundwater exposure pathway. Installation of a surface-water diversion or collection system is recommended in order to reduce the potential for humans and livestock to come in contact with contaminated water and sediment. To reduce exposure to villagers, groundwater treatment should be considered if elevated uranium or other contaminants are detected in drinking water. Installing water-treatment systems would likely be quicker to accomplish than remediation and excavation of the Adaya Burial Site. The known potential for human exposure to uranium and metals (such as arsenic, chromium, selenium, and strontium) at the Adaya Burial Site is serious. Additional characterization , mitigation, and remediation efforts should be given a high priority.

54 ENVIRONMENTAL SCIENCES↗