Search NASA⌕ Search

SEARCH · Search NASA

Results for “PV MODULES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Long Term Damage Testing (NREL)

DOE's Regional Test Center program has fielded several strings of PV modules as part of their Long Term Testing program. Some of these modules have been installed since 2016 and have been exposed to severe weather events. A key to developing long lifespans for PV modules (in excess of 30 years) is understanding how damage and defects develop, propagate and progress. Researchers at the NREL Regional Test Center have started developing testing procedures and analysis tools in order to characterize modules in a controlled manner with the goal of understanding how damage spreads under normal operations. Characterization methods include EL and IR imaging, outdoor and indoor IV curves, and long term exposure monitoring. Modules to be evaluated will be chosen based on severity of defect, ability to track changes in defect and space requirements. The samples will be loaded at maximum power using grid-tied inverters or other means. Gathering and reporting on this data may help engineers and scientists design for damage and improve long-term performance.

crack damage↗

Quantifying Reliability - The Next Step for a Rapidly Maturing PV Industry and China's Role

PV customers wish to know how long their PV modules will last, but quantitatively predicting service life is difficult because of the large number of ways that a module can fail, the variability of the use environment, the cost of the testing, and the short product development time, especially when compared with the long desired lifetime. China should play a key role in developing international standards because China manufactures most of the world's PV modules. The presentation will describe the steps that need to be taken to create a service life prediction within the context of a defined bill of materials, process window and use environment. Worldwide standards for cost-effective approaches to service-life predictions will be beneficial to both PV customers and manufacturers since the consequences of premature module failure can be disastrous for both.

14 SOLAR ENERGY↗

An Updated Life Cycle Assessment of Utility-Scale Solar Photovoltaic Systems Installed in the United States

Given the high deployment targets for solar photovoltaics (PV) needed to meet U.S. decarbonization goals, and the limited carbon budget remaining to limit global temperature rise, accurate accounting of the energy-use and greenhouse-gas emissions over the life-cycle of PV systems is needed. In the United States, most PV systems are large utility-scale systems which use single-axis trackers and central inverters, which are not commonly examined in existing life-cycle assessment (LCA) literature. In this study, we present a cradle-to-grave LCA of a typical silicon U.S. utility PV (UPV) installation which is consistent with the utility system features documented in the annual NREL PV system cost benchmark reports. We analyze and present results for four main metrics: cumulative energy demand (CED), greenhouse gas (GHG) emissions, energy payback time (EPBT), and carbon payback time (CPBT). We consider six primary manufacturing options: three based on an imported PV module supply chain (comparing low-carbon imports, high-carbon imports, and average imports), and three based on a potential domestic PV module supply chain (comparing low-carbon U.S. regions, high-carbon U.S. regions, and average U.S. regions). These manufacturing options were then paired with installation locations to create six main cases: low-carbon options were installed in Phoenix (Arizona), high-carbon options were installed in Seattle (Washington), and average options were installed in Fredonia (Kansas). These locations were selected to represent a range of irradiance and grid mixes in the United States, in order to illustrate the likely range of EPBTs and CPBTs possible across the United States. For all six cases, a sensitivity analysis for end-of-life (EOL) handling was explored to capture current and future management options: landfilling, partial recycling, and high-quality recycling. For the purposes of this report, the benchmark system was defined to use an average imported supply chain with partial recycling, installed in Fredonia (Kansas). CED results show ratios at or below 0.1 MJ oil-eq /MJgenerated which demonstrates efficient use of primary energy resources (below a 1:1 ratio), and represents a slight improvement over previous results in literature. GHG emissions per kWh range from 10-36 g CO 2 e, which are consistent with or lower than previous results published by NREL and IEA-PVPS. We use a graphical approach for calculating EPBT and CPBT in this report, which improves upon methods typically used in literature by accounting for non-linearity and avoiding data quality issues associated with long-term projections. EPBT was determined to vary from 0.5 to 1.2 years, with a benchmark EPBT of 0.6 years; CPBT was shown to vary from 0.8 to 20 years, with benchmark CPBT of 2.1 years, which is lower than other estimates from recent literature (typically >2 years).

14 SOLAR ENERGY↗

Technoeconomic Analysis of Photovoltaics Module Manufacturing with Thin Silicon Wafers

Reducing silicon usage by adopting thinner wafers can significantly reduce capital expenditure (capex) and cost, and thus accelerate the growth of manufacturing capacity and deployment. In this work, we evaluated potential benefits of thin Si wafers for current and future PV modules. We apply a technoeconomic framework that couples bottom-up cost model, and a cash-flow growth model to analyze PV modules with thin wafers. First, we show that, comparing the current PERC with 160 um thick wafers to the high-efficiency concept with 50 um thin wafers, the capex is reduced from 0.39 to 0.2 $/(W/year) while the cost is from 0.32 to 0.2 $/W. Second, the potential of accelerated deployment is analyzed for the highefficiency thin wafer concept. We found the significant advantages of higher growth rate (~20% relative) and higher deployment plateau (~3 times) than the current PERC modules. modules with thin wafers. First, we show that, comparing the current PERC with 160 um thick wafers to the high-efficiency concept with 50 um thin wafers, the capex is reduced from 0.39 to 0.2 $/(W/year) while the cost is from 0.32 to 0.2 $/W. Second, the potential of accelerated deployment is analyzed for the highefficiency thin wafer concept. We found the significant advantages of higher growth rate (~20% relative) and higher deployment plateau (~3 times) than the current PERC modules.

14 SOLAR ENERGY↗

Selection of optimal wavelengths for optical soiling modelling and detection in photovoltaic modules

Soiling impacts the photovoltaic (PV) module performance by decreasing the amount of light reaching the photovoltaic cells and by changing their external spectral response. Currently, the soiling monitoring market is moving toward optical sensors that measure transmittance or reflectance, rather than directly measuring the impact of soiling on the performance of photovoltaic modules. These sensors, which use a single optical measurement, are not able to correct the soiling losses that depend on the solar irradiance spectra and on the spectral response of the monitored PV material. This work investigates methods that can improve the optical detection of soiling by extracting the full soiling spectrum profiles using only two or three monochromatic measurements. Spectral transmittance data, measured with a spectrophotometer and collected during a 46-week experimental soiling study carried out in Jaén, Spain, was analysed in this work. The use of a spectral profile for the hemispherical transmittance of soiled PV glass is found to significantly improve the soiling detection, returning the lowest errors independently of the PV materials and irradiance conditions. In addition, this work shows that it is also possible to select the measurement wavelengths to minimize the soiling loss detection error depending on the monitored PV semiconductor material (silicon, CdTe, a-Si, CIGS and a representative perovskite). The approaches discussed in this work are also found to be more robust to potential measurement errors compared to single wavelength measurement techniques.

14 SOLAR ENERGY↗

FY2018 PV Lifetime Annual Report (Final Project Report)

Started in 2016, the PV Lifetime Project is measuring PV module and system degradation profiles over time with the aim of distinguishing different module types and technology. Outdoor energy monitoring in different climates is supplemented with regular testing under repeatable test conditions indoors. The focus is on the PV module, as well as other hardware components (junction boxes, bypass diodes, and module-level electronics) attached to it. Hardware is installed at Sandia National Laboratories in New Mexico, at the National Renewable Energy Laboratory in Colorado, and at the University of Central Florida. The systems are continuously monitored for DC current and voltage, as well as periodic I-V curves at the string level. In the future, once degradation trends have been identified with more certainty, results will be made available to the public online. This data is expected to enable an increase in the accuracy and precision of degradation profiles used in yield assessments that support investments made in new PV plants. Current practice is to assume that degradation is constant over the life of the system. Forthcoming results in the next few years will help to determine whether this assumption is still appropriate.

14 SOLAR ENERGY↗

Accelerated and Outdoor Aging Effects on Photovoltaic Module Interfacial Adhesion Properties

We have developed an apparatus that allows the measurement of applied torque as a function of angle of twist during shear removal of cored specimens. This allows us to characterize the strength and durability of various interfaces within many types of photovoltaic (PV) modules. We have used this device to evaluate several parameters in terms of their ability to quantify degradation of interfacial adhesion in weathered PV modules. The usefulness of shear modulus in this regard is marginal. However, peak torque, angle at peak torque, and toughness are very sensitive parameters.

14 SOLAR ENERGY↗

Indoor Soil Deposition Chamber: Evaluating Effectiveness of Antisoiling Coatings

An indoor soil deposition method has been developed to simulate natural soil deposition on glass coupons or one-cell and multicell photovoltaic (PV) modules. This method uses variable ambient humidity, coupon/module temperature, and dust composition within a single custom-made chamber to create a natural and uniform soil deposition layer. Antisoiling (AS) coatings from two different manufacturers were applied on two one-cell monocrystalline silicon modules. Three layers of Arizona road dust have been deposited on the one-cell modules with AS coatings and an uncoated one-cell reference module at varied humidity levels. The soiled modules were exposed to an open-circuit subsonic wind tunnel at varying speeds and the effectiveness of AS coatings have been quantified using the transmittance gain. Transmittance loss resulting from the AS coating has been measured and compared with the transmittance of the uncoated reference module using a reflectance spectrophotometer. Reflectance measurements have also been taken to compare the transmittance loss of Arizona road dust and soil collected from PV modules' superstrates. The soiled one-cell modules were then exposed to rain from a rain simulator. The transmittance gain due to rain exposure is quantified using a rain gain and rain coefficient. These tests cumulatively may be used to help develop a test standard for evaluating the effectiveness of AS coatings.

14 SOLAR ENERGY↗

Bonded Bracket Assmebly for Frameless Solar Panels

In February 2011 the US Department of Energy announced their new Sunshot Initiative. The Sunshot goal is to reduce the total cost of solar energy systems by about 75 percent before the end of the decade. The DOE estimated that a total installed cost of $$1 per watt for photovoltaic systems would be equivalent to 5-6¢/kilowatt hour (kWh) for energy available from the grid. The DOE also estimated that to meet the $1 per watt goal, PV module costs would need to be reduced to $ .50 per watt, balance of systems costs would need to be reduced to $.40 per watt, and power electronic costs would need to reach $.10 per watt. To address the BOS balance of systems cost component of the $1 per watt goal, the DOE announced a funding opportunity called (BOS-X) Extreme Balance of System Hardware Cost Reductions. The DOE identified eight areas within the total BOS costs: 1) installation labor, 2) installation materials, 3) installation overhead and profit, 4) tracker, 5) permitting and commissioning, 6) site preparation, 7) land acquisition, 8) sales tax. The BOS-X funding announcement requested applications in four specific topics;Topic 1: Transformational Building Integrated Photovoltaic (BIPV) Modules; Topic 2: Roof and Ground Mount Innovations; Topic 3: Transformational Photovoltaic System Designs; and Topic 4: Development of New Wind Load Codes for PV Systems.The application submitted by ARaymond Tinnerman reflected the requirements listed in Topic #2, Roof and Ground Mount Innovations. The goal of topic #2 was to develop technologies that would result in the extreme reduction of material and labor costs associated with applications that require physical connections and attachments to roof and ground mount structures. The topics researched in this project included component cost reduction, labor reduction, weight reduction, wiring innovations, and alternative material utilization. The project objectives included; 1) The development of an innovative quick snap bracket assembly that would be bonded to frameless PV modules for commercial rooftop installations; 2) The development of a composite pultruded rail to replace traditional racking materials; 3) In partnership with a roofing company, pilot the certification of a commercial roof to be solar panel compliant, eliminating the need for structural analysis and government oversight resulting in significantly decreased permitting costs; and 4) Reduce the sum of all cost impacts in topic #2 from a baseline total of $2.05/watt to $.34/watt.

14 SOLAR ENERGY↗

PSCAD Modules Representing PV Generator

Photovoltaic power plants (PVPs) have been growing in size, and the installation time is very short. With the cost of photovoltaic (PV) panels dropping in recent years, it can be predicted that in the next 10 years the contribution of PVPs to the total number of renewable energy power plants will grow significantly. In this project, the National Renewable Energy Laboratory (NREL) developed a dynamic modeling of the modules to be used as building blocks to develop simulation models of single PV arrays, expanded to include Maximum Power Point Tracker (MPPT), expanded to include PV inverter, or expanded to cover an entire PVP. The focus of the investigation and complexity of the simulation determines the components that must be included in the simulation. The development of the PV inverter was covered in detail, including the control diagrams. Both the current-regulated voltage source inverter and the current-regulated current source inverter were developed in PSCAD. Various operations of the PV inverters were simulated under normal and abnormal conditions. Symmetrical and unsymmetrical faults were simulated, presented, and discussed. Both the three-phase analysis and the symmetrical component analysis were included to clarify the understanding of unsymmetrical faults. The dynamic model validation was based on the testing data provided by SCE. Testing was conducted at SCE with the focus on the grid interface behavior of the PV inverter under different faults and disturbances. The dynamic model validation covers both the symmetrical and unsymmetrical faults.

14 SOLAR ENERGY↗

Solar Photovoltaics: Supply Chain Deep Dive Assessment

This is one of a series of reports and deep dive assessments produced in response to Executive Order 14017 “America’s Supply Chains,” which directs the Secretary of Energy to submit a report on supply chains for the energy sector industrial base. The Executive Order is helping the federal government to build more secure and diverse U.S. supply chains, including energy supply chains. Over the past decade, solar power has gone from an emerging, niche technology to a mature energy industry. By 2035, solar power could supply 40% or more of U.S. electricity demand, dramatically accelerating the decarbonization of buildings, transportation, and industry; and, if current technology trends continue, it could do so without increasing the price of electricity. The rapid expansion of solar energy has the potential to yield broad benefits in the form of economic activity and workforce development. The solar industry already employs roughly 230,000 people in the United States, at an average wage that is higher than the national average for most comparable positions. By decarbonizing the electricity sector by 2035, the U.S. solar industry could employ 500,000–1,500,000 people by 2030. The components that are assembled to install a photovoltaic power system are produced by a global supply chain. Photovoltaic (PV) modules (also called panels) are made of cells that use a variety of technologies. There are two leading types of solar modules used in the United States, with crystalline silicon (c-Si) modules representing 84% of the market and cadmium telluride (CdTe) modules representing 16% of the market. Modules of either type require mounting structures to provide mechanical support (racking), which may be configured to follow the sun (tracking). The output of any PV module is direct current (dc), which is almost always converted to alternating current (ac) by an inverter.

14 SOLAR ENERGY↗

Reproducing the 'Framing' by a Sequential Stress Test

The 'Framing' (local discoloration along cell edges) was induced by a simple sequential accelerated stress test (consisting of hygrothermal- and UV-stressors) applied to the PV modules with high OTR (oxygen transmission rate) backsheet, irrespective of the inclusion of UV-absorber in poly(ethylene-co-vinyl acetate) (EVA) encapsulant. UV-fluorescence imaging of the PV modules suggests that the spatially-inhomogeneous degradation of EVA material under UV-irradiating conditions is correlated to this 'Framing' indicating an underlying common mechanism. These findings would contribute to the development of test procedures to broadly mimic the actual failures observed in fielded PV.

14 SOLAR ENERGY↗

Lessons from the IEC Durability of Adhesion Accelerated Test Sequence

The IEC 62788-1-1 and IEC 63209-2 standards use aging sequences for durability of adhesion in photovoltaic (PV) modules, which may be evaluated using the single cantilever beam (SCB) test. Because the encapsulant forms critical interfaces with the front glass and solar cells, degradation at those interfaces under ultraviolet (UV) exposure, elevated temperature, and humidity can lead to interfacial delamination - compromising the long-term reliability. In this work, adhesion durability of UV-transmitting poly(ethylene-co-vinyl acetate) (EVA) encapsulant to glass and to silicon solar cells is evaluated after sequenced UV and damp heat aging (85C/85%RH). Laminates were prepared using StarPhire solar front glass with thin glass or PERC cells, and two EVA formulations with different concentrations of siloxane coupling agent. Adhesion was quantified by measuring critical debond energy using the SCB method. Both formulations exhibit similar qualitative trends, while different adhesion is observed at the periphery despite the use of low-shrink manufacturing. The results show that while glass/EVA adhesion remains stable or increases after UV exposure and shows only moderate changes after damp heat, the EVA/cell interface exhibits an irreversible loss of adhesion following UV and then damp heat exposure. Although glass/EVA interfaces generally exhibit lower debond energies, the EVA/cell interface is significantly more vulnerable to UV-driven degradation, identifying it as the dominant reliability risk location through early- and intermediate-module life. These results demonstrate that accelerated aging sequences can expose large, interface-specific losses in adhesion durability and underscore the importance of interface engineering for long-term PV module reliability.

14 SOLAR ENERGY↗