Search NASA⌕ Search

SEARCH · Search NASA

Results for “PV variability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Evaluation of PV Module Packaging Strategies of Monofacial and Bifacial PERC Using Degradation Pathway Network Modeling

As the PV industry is rapidly expanding, it is important to thoroughly investigate the long-term impact of packaging strategies on the performance of PV modules. In this study, the variants in sets differ on the basis of manufacturer (A/B), encapsulant (EVA/POE), rear encapsulant (UV-cutoff/opaque/transparent), module architecture (GB/DG) and cell type (monofacial/bifacial). The minimodules were exposed for 2520 hours in modified damp heat, with or without full spectrum light. Every 504 hours, stepwise electrical characterization techniques were employed to track changes in minimodules. Degradation pathway modeling using network structural equation modeling was employed to study pairwise relationships between variables and service lifetime prediction in minimodules. Through this study, differences in quality control are identified in minimodules made by different manufacturers. Minimodules with UV-cutoff rear encapsulant show relatively better stability, whereas the ones with opaque rear encapsulant show greater power loss. In addition, GB having UV-cutoff rear encapsulation and GB with POE having opaque rear encapsulation were identified to be stable as they lack a best model fit. Here, the primary power loss mechanism in degrading variants is interconnect corrosion.

14 SOLAR ENERGY↗

SolarAPP+ Performance Review: 2021 Data

Accelerating rooftop solar photovoltaic (PV) deployment has strained the capacity of local authorities responsible for permitting, inspection, and interconnection (PII). Given the ongoing expansion of rooftop PV, a growing number of authorities having jurisdiction (AHJs) and utilities are reforming PII processes to reduce delays. AHJs could significantly reduce PII timelines through reforms such as expedited reviews for small-scale systems, online customer portals, and over-the-counter permitting. However, independent reforms do not resolve issues associated with PII variability across AHJs, and many AHJs lack the resources to implement reforms. In response to these challenges, the National Renewable Energy Laboratory (NREL) developed the Solar Automated Permit Processing Plus (SolarAPP+) platform, in collaboration with local governments, code development organizations, and industry stakeholders. This report shows SolarAPP+ performance in 2021 across AHJs.

14 SOLAR ENERGY↗

Crack detection in crystalline silicon solar cells using dark-field imaging

The high capital expenditure (capex) necessary to manufacture crystalline silicon PV modules negatively affects the levelized cost of electricity (¢/kWh) and critically impacts the rate at which the PV industry can scale up. Wafer, cell, and module fabrication with thin free-standing silicon wafers is one key to reduce capex. Thin wafers reduce capex associated with silicon refining and wafer fabrication, which together sum to 58% of the total capex of silicon module manufacturing. In addition, thin wafers directly and significantly reduce variable costs. However, introducing 50 μm thin free-standing wafers into today’s manufacturing lines result in cracking, creating a yield-based disincentive. Due to the brittle nature of silicon, wafer breakage is the major concern due to the high stress that is induced during processes in manufacturing lines. In this paper, we describe an improved method for edge micro-crack detection that can help enable low-capex, thin free-standing Si wafers. We present a method of detecting and measuring cracks along wafer edges by using a dark-field IR scattering imaging technique which enables detection of edge cracks at the micron scale.

14 SOLAR ENERGY↗

Chance-constrained Service Restoration for Distribution Networks with Renewables

Power systems operation is facing great challenges from natural disasters and cyber-attacks. It is critical but also difficult to enhance the reliability and resilience against extreme events. To better response to inevitable outages or blackouts, service restoration in distribution networks is important to minimize the disastrous impacts of catastrophic events. The increasing penetration of distributed energy resources (DERs) provides new opportunities to expedite the restoration process. However, the coordination with conventional distribution system control devices and the uncertainty and variability of intermittent renewable energy resources requires new operation and control strategies for distribution service restoration (DSR). This paper develops an optimal bottom-up DSR strategy by coordinating DERs with voltage regulators and capacitor banks. The chance-constrained (CC) programming approach is used to model the probabilistic output limit of solar radiation and PV generation. The Markov's inequality and Latin hypercube sampling techniques are applied to convert and incorporate the chance constraints into the DSR optimization problem. The CC-DSR problem is formulated as a mixed integer convex programming problem, considering various operational cost functions and bidirectional three-phase unbalanced load flow. Simulation results on the modified IEEE 13-node test feeder system demonstrate the effectiveness and flexibility of the bottom-up DSR strategy.

Chance constrained optimization, Distribution serv↗

Interannual Variability of the North Polar Vortex in the Lower Stratosphere During the UARS Mission

Northern winters since the 1991 launch of UARS are compared to earlier years (1978 -1991) with respect to the potential for formation of Polar Stratospheric Clouds and for isolation of the north polar vortex. Daily NMC temperature minima at 465 K late in the winter of 1993-94 and again in December 1994 were the lowest values experienced during these times of the year (since 1978). Northern PV gradients were unusually strong in 1991-92 prior to late January and throughout the winter in both 1992-93 and 1994-95. Of all northern winters since 1978, 1994-95 with its early extended cold spell and persistently strong PV gradients most resembled the Antarctic winter lower stratosphere. Even so, temperatures was never as low, nor was the polar vortex as large, as during a typical southern winter. Judged by daily temperature minima and PV gradients at 465 K, meteorological conditions in the Arctic winter lower stratosphere during the UARS period were more conducive to vortex ozone loss by heterogeneous chemistry than in most previous winters since 1978-79.

Zurek, R. W.↗

Clean Energy Manufacturing: U.S. Competitiveness and State Policy Strategies (Presentation)

The capital intensive nature of clean energy technologies suggests that manufacturing clean energy equipment has the potential to support state and local economic development efforts. However, manufacturing siting decisions tend to be complex and multi-variable decision processes that require in-depth knowledge of specific markets, the logistical requirements of a given technology, and insight into global clean tech trends. This presentation highlights the potential of manufacturing in supporting economic development opportunities while also providing examples of the financial considerations affecting manufacturing facility siting decisions for wind turbine blades and solar PV. The presentation also includes discussion of other more qualitative drivers of facility siting decisions as gleaned from NREL industry interviews and discusses strategies state and local policymakers may employee to bolster their chances of successfully attracting clean energy manufacturers to their localities.

14 SOLAR ENERGY↗

Clear Sky Irradiance Year-to-Year Variations and Trends: Preprint

Solar radiation data for seven SURFRAD stations for the period 1996-2018 show an increase in irradiance under clear skies over time, with an interannual variability of the increase. A popular implementation of a clear sky model provided modeled irradiances for comparison with the SURFRAD data under conditions screened for clear skies. The use of the clear sky model, which did not consider year-to-year variances in atmospheric turbidity, was found problematic for resolving small changes in irradiance important for determining PV system degradation over three or five years, but less problematic for a period of ten years.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Mixture-process variable approach to optimize a microemulsion electrokinetic chromatography method for the quality control of a nutraceutical based on coenzyme Q10

In recent years, multivariate optimization has played an increasing role in analytical method development. ICH guidelines recommend using statistical design of experiments to identify the design space, in which multivariate combinations of composition variables and process variables have been demonstrated to provide quality results. Considering a microemulsion electrokinetic chromatography method (MEEKC), the performance of the electrophoretic run depends on the proportions of mixture components (MCs) of the microemulsion and on the values of process variables (PVs). In the present work, for the first time in the literature, a mixture-process variable (MPV) approach was applied to optimize a MEEKC method for the analysis of coenzyme Q10 (Q10), ascorbic acid (AA), and folic acid (FA) contained in nutraceuticals. The MCs (buffer, surfactant-cosurfactant, oil) and the PVs (voltage, buffer concentration, buffer pH) were simultaneously changed according to a MPV experimental design. A 62-run MPV design was generated using the I-optimality criterion, assuming a 46-term MPV model allowing for special-cubic blending of the MCs, quadratic effects of the PVs, and some MC-PV interactions. The obtained data were used to develop MPV models that express the performance of an electrophoretic run (measured as peak efficiencies of Q10, AA, and FA) in terms of the MCs and PVs. Contour and perturbation plots were drawn for each of the responses. Finally, the MPV models and criteria for the peak efficiencies were used to develop the design space and an optimal subregion (i.e., the settings of the mixture MCs and PVs that satisfy the respective criteria), as well as a unique optimal combination of MCs and PVs.

Coenzyme Q10↗

Residential Solar Adoption Timelines and Impacts from the COVID-19 Pandemic

In this study we evaluate PII and other PV adoption timelines from 2017-2021. We use project-level data collected by the National Renewable Energy Laboratory (NREL) for the Solar Time-Based Residential Analytics and Cycle Time Estimator (SolarTRACE). Additionally, we conducted a survey of 171 AHJs about their experiences, challenges, and process changes during the first 18 months of the COVID-19 pandemic. The survey findings were supplemented with follow up interviews with 5 AHJs from 4 states. We find that the pandemic moderately increased the duration and variability of pre-install timelines (contract signing to install), particularly in the permit review phase (permit submit to approval). In contrast, post-install timelines (install to final utility interconnection) continued to decline during the pandemic. The net result is that overall project timelines (contract signing to final interconnection) continued to decline during the pandemic. Our findings suggest that AHJs and installers faced challenges throughout the pandemic but ongoing improvements in PII processes - particularly post-install processes - more than offset these challenges. Furthermore, the pandemic may have catalyzed or accelerated a widespread adoption of online/electronic permitting, among other process efficiency improvements.

14 SOLAR ENERGY↗

Advanced HVAC System for Smart Grid

Rocky Research (Boulder City, NV) has developed an advanced roof top air conditioning unit (RTU) with the potential for providing smart grid functions such as regulation services and PV integration. The RTU contains advanced technologies that have been demonstrated to enable 1) improved coefficient of performance (COP) during start-up transients, 2) improved steady-state efficiency, and 3) blending of DC and AC power with high conversion efficiency. Technologies incorporated by Rocky Research include a pulsing thermal expansion valve (PTXV) to dynamically optimize refrigerant flow, a variable frequency drive (VFD) for the compressor, and on-board integrated power conversion electronics for inverting and blending DC and AC power.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cybersecurity Risk Profiles for Distributed Energy Resource Management Systems

Managing the digitalization of increasingly diversity energy resources is a complex challenge for energy systems planners and managers. As the penetration of solar photovoltaics (PV) and other distributed renewable energy resources (DERs) expands, distributed energy resource management systems (DERMS) will play an increasingly important role in managing, monitoring, and controlling DERs as electric systems before more distributed, interconnected, and networked. However, the cybersecurity implications of DERMS deployments are not well understood today. A lack of understanding around the cybersecurity implications of DERMS deployments and variability in the security posture of DERMS vendors, owners, and operators could introduce new security risks to evolving electric power systems. This paper describes cybersecurity attack scenarios on DERMS, identifies related cybersecurity standards and guidelines, reviews the security features of state-of-the-art DERMS solutions, and offers cybersecurity guidance for DERMS vendors, owners, and operators to protect DERMS' unique capabilities. Standardizing cybersecurity requirements for DERMS could help improve the security of DERMS integrations and improve innovations that are more secure by design. The cybersecurity guidance found in this paper is intended to offer a unified approach and lay the foundation for future standardization of DERMS cybersecurity to reduce risk to the solar industry and other renewable energy stakeholders when integrating these technologies with electric power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantifying Resolution Implications for Agent-based Distributed Energy Resource Customer Adoption Models

In this report we explore tradeoffs of top-down and bottom-up methods in their precision and computational burden using NREL's dGen model, an agent-based model of residential and non-residential distributed PV adoption. In particular, we assess the role of agent resolution in instantiating statistically-representative populations in the model--and the resulting variance of model projections at the state, sector and county levels. Running the model for a single state with fixed macroeconomic assumptions, we vary both the number of agents instantiated and the number of unique simulations. Notably, in each run we introduce sources of uncertainty in cumulative DPV adoption results during agent instantiation as we stochastically sample agent attributes from localized building characteristic and solar resource distributions. We find three key trends which guide what can be expected of results. First, precision of the model projections, as measured by the variance of the unique simulations increased as a function of the number of agents sampled, though with diminishing returns to scale. The result is expected given the Law of Large Numbers. Second, the mean or expected value of projections decreased as the number of agents instantiated increased. Empirically, aggregate DPV capacities projected by dGen are 7% lower on average at a 10-agent resolution compared to 1-agent resolutions, and up to 10% lower in the non-residential sector. We attribute this outcome to a system sizing scheme that biases lower cumulative installed capacity as agent resolution increases when roof size and load are not positively correlated. Finally, the variance of model projections differed by sector, where variance was substantially larger in the commercial sector, largely due to differences in parameterization by sector. We explain the larger variance in the non-residential sector as an outcome of the greater variance in building uses and load shapes as compared to the residential sector, and we find that a resolution on the order of 100-agents per county would be necessary to bring non-residential variance in line with residential variance at a 2-agent resolution. We propose that further research explore increasing precision and agent resolution in the non-residential sector. Moreover, given that days of intensive computing may be required to resolve a suitable estimate even at the extent of a single state within acceptable levels of precision, to promote computational efficiency we also suggest more clearly quantifying sources of variability at the county level such that resolution can by dynamically increased where county level results are least precise.

14 SOLAR ENERGY↗

Optimal Distribution System Voltage Regulation using State Estimation and DER Grid-Support Functions

Increasing solar energy penetrations may create challenges for distribution system operations because production variability can lead to large voltage deviations or protection system miscoordination. Instituting advanced management systems on distribution systems is one promising method for combating these challenges by intelligently controlling distribution assets to regulate voltage and ensure protection safety margins. While it is generally not the case today, greater deployment of power system sensors and interoperable distributed energy resources (DER)e.g., photovoltaic (PV) inverters, energy storage systems (ESS), electric vehicles (EVs)will enable situational awareness, control, and optimization of distribution systems. In this work, a control system was created which measures power system parameters to estimate the status of a feeder, forecasts the distribution state over a short-term horizon, and issues optimal set point commands to distribution-connected equipment to regulate voltage and protect the system. This two-year project integrated multiple research innovations into a management system designed to safely allow PV penetrations of 50% or greater. The integrated software was demonstrated through extensive real-time (RT) and power hardware-in-the-loop studies and a field demonstration on a live power system with a 684 kVA PV system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stratosphere-to-Troposphere Transport Revealed by Ground-based Lidar and Ozonesonde at a Midlatitude Site

This paper presents ozone structures measured by a ground-based ozone lidar and ozonesonde at Huntsville, Alabama, on 27-29 April 2010 originating from a stratosphere-to-troposphere transport event associated with a cutoff cyclone and tropopause fold. In this case, the tropopause reached 6 km and the stratospheric intrusion resulted in a 2-km thick elevated ozone layer with values between 70 and 85 ppbv descending from the 306-K to 298-K isentropic surface at a rate of 5 km day1. The potential temperature was provided by a collocated microwave profiling radiometer. We examine the corresponding meteorological fields and potential vorticity (PV) structures derived from the analysis data from the North American Mesoscale model. The 2-PVU (PV unit) surface, defined as the dynamic tropopause, is able to capture the variations of the ozone tropopause estimated from the ozonesonde and lidar measurements. The estimated ozone/PV ratio, from the measured ozone and model derived PV, for the mixing layer between the troposphere and stratosphere is approximately 41 ppbv/PVU with an uncertainty of approximately 33%. Within two days, the estimated mass of ozone irreversibly transported from the stratospheric into the troposphere is between 0.07 Tg (0.9 10(exp33) molecules) and 0.11 Tg (1.3 10(exp33) molecules) with an estimated uncertainty of 59%. Tropospheric ozone exhibited enormous variability due to the complicated mixing processes. Low ozone and large variability were observed in the mid-troposphere after the stratospheric intrusion due to the westerly advection including the transition from a cyclonic system to an anticyclonic system. This study using high temporal and vertical-resolution measurements suggests that, in this case, stratospheric air quickly lost its stratospheric characteristics once it is irreversibly mixed down into the troposphere.

Kuang, Shi↗

Optimization of a Virtual Power Plant to Provide Frequency Support.

Increasing the penetration of distributed renewable sources, including photovoltaic (PV) sources, poses technical challenges for grid management. The grid has been optimized over decades to rely upon large centralized power plants with well-established feedback controls, but now non-dispatchable, renewable sources are displacing these controllable generators. This one-year study was funded by the Department of Energy (DOE) SunShot program and is intended to better utilize those variable resources by providing electric utilities with the tools to implement frequency regulation and primary frequency reserves using aggregated renewable resources, known as a virtual power plant. The goal is to eventually enable the integration of 100s of Gigawatts into US power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-Timescale Integrated Dynamics and Scheduling for Solar (MIDAS-Solar) (Final Technical Report)

Solar photovoltaic (PV) installations have experienced unprecedented growth in the United States. PV will become not only an energy producer but also a necessary provider of ancillary services at multiple timescales. Conventional methods to simulate power systems operations - such as long-term production simulation (which typically considers schedules from hours to minutes by using an optimization framework) and short-term transient studies (which simulate dynamics from seconds to sub-seconds using state variables and differential equations) - are not sufficient for studying the multiple-timescale variation of solar generation and its impact on system reliability. Long-term system economics and short-term system dynamics are highly coupled, particularly when the penetration level of renewable generation is extremely high, because the uncertainty and variability of solar generation will impact both power system steady-state and dynamic performance. This project helps meet and exceed the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Solar Energy Technologies Office goal of systems integration by directly addressing this stability and reliability challenge for power grid planning and operation. We have developed a temporally comprehensive, closed-loop simulation model, named Multi-timescale Integrated Dynamics and Scheduling (MIDAS), that seamlessly simulates power system operations from economic scheduling (day-ahead to hours) to dynamic response analysis (seconds to sub-seconds). For schedules with very high levels of inverter-based resources (IBRs), up to and including 100%, the stability of grid controls has been evaluated through electromagnetic transient (EMT) simulations and power-hardware-in-the-loop (PHIL) simulations of key transient events at key schedule points. Specifically, MIDAS provides: 1) a closed-loop simulation framework for simulating timescales from economic scheduling to dynamic stability analysis; 2) machine learning-based stability assessment; 3) EMT modeling and analysis for large-scale power systems; 4) MIDAS PHIL test bed. We worked with Hawaii Electric Companies to apply the MIDAS study framework to a Maui grid study. The entire island's transmission system was modeled in detail - from a yearly scheduling model, to a second-level frequency dynamic model, down to a sub-second-scale EMT model to address critical stability issues. The project demonstrated how MIDAS can help system planners and operators assess system reliability and stability while the power grid is marching toward a high-renewable, high-IBR future. In this Maui grid study, we found that 100% instantaneous IBR operation is achievable in EMT simulation and PHIL testing, and grid planners and operators might need new analysis/simulation tools to assess grid reliability and stability in the scheduling stage. MIDAS will bring Maui and other systems closer to 100% clean and stable energy futures. (In this study, we examined transient stability. Other topics necessary for 100% IBR operation, such as protection and resource adequacy, were not examined.)

100% Renewables↗

Channel Access in Erlang

We have developed an Erlang language implementation of the Channel Access protocol. Included are low-level functions for encoding and decoding Channel Access protocol network packets as well as higher level functions for monitoring or setting EPICS process variables. This provides access to EPICS process variables for the Fermilab Acnet control system via our Erlang-based front-end architecture without having to interface to C/C++ programs and libraries. Erlang is a functional programming language originally developed for real-time telecommunications applications. Its network programming features and list management functions make it particularly well-suited for the task of managing multiple Channel Access circuits and PV monitors.

Nicklaus, Dennis J.↗

Comparing Outdoor to Indoor Performance for Bifacial Modules Affected by Polarization-Type Potential-Induced Degradation

Bifacial photovoltaic (PV) modules have the advantage of using light reflected off of the ground to contribute to power production. Predicting the energy gain is challenging and requires complex models to do so accurately. Often, module degradation over time is neglected in models for the sake of simplicity or is underestimated. Comparing outdoor and indoor current–voltage (I–V) performance for bifacial modules is more challenging than for monofacial modules, as there are additional variables to consider such as rear albedo non-uniformity, cell mismatch, and their effects on temperature. This challenge is compounded when heterogeneous degradation modes occur, such as polarization-type potential-induced degradation (PID-p). To examine the effects of PID-p on I–V predictions using an empirical data-driven approach, 16 bifacial PERC modules are installed outdoors on racks with different albedo conditions. A subset is exposed to high-voltage biases of −1500 V or +1500 V. Outdoor data are traced at irradiance ranges of 150–250 W/m 2 , 500–600 W/m 2 , and 900–1000 W/m 2 . These curves are corrected using control module temperature, wire resistivity, and module resistance measured indoors. We examine several methods to transform indoor I–V curves to accurately, and more simply than existing methods, approximate outdoor performance for bifacial modules without and with varying levels of PID-p degradation. This way, bifacial performance modeling can be more accessible and informed by fielded, degraded modules. Distributions of percent errors between indoor and outdoor performance parameters and Mean Absolute Percent Errors (MAPEs) are used to assess method quality. Results including low-irradiance data (150–250 W/m 2 ) are discussed but are filtered for quantifying method quality as these data introduce substantial errors. The method with the most optimal tradeoff between low MAPE and analysis simplicity involves measuring the front side of a module indoors at an irradiance equal to plane-of-array irradiance plus the product of module bifaciality and albedo irradiance. This method gives MAPE values of 1–6.5% for non-degraded and 1.6–5.9% for PID-p degraded module performance.

14 SOLAR ENERGY↗