Search NASA⌕ Search

SEARCH · Search NASA

Results for “Padding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

A quantum encryption design featuring confusion, diffusion, and mode of operation

Abstract Quantum cryptography—the application of quantum information processing and quantum computing techniques to cryptography has been extensively investigated. Two major directions of quantum cryptography are quantum key distribution (QKD) and quantum encryption, with the former focusing on secure key distribution and the latter focusing on encryption using quantum algorithms. In contrast to the success of the QKD, the development of quantum encryption algorithms is limited to designs of mostly one-time pads (OTP) that are unsuitable for most communication needs. In this work we propose a non-OTP quantum encryption design utilizing a quantum state creation process to encrypt messages. As essentially a non-OTP quantum block cipher the method stands out against existing methods with the following features: 1. complex key-ciphertext relation (i.e. confusion) and complex plaintext-ciphertext relation (i.e. diffusion); 2. mode of operation design for practical encryption on multiple blocks. These features provide key reusability and protection against eavesdropping and standard cryptanalytic attacks.

97 MATHEMATICS AND COMPUTING↗

Identification of genetic loci that control mammary tumor susceptibility through the host microenvironment

The interplay between host genetics, tumor microenvironment and environmental exposure in cancer susceptibility remains poorly understood. Here we assessed the genetic control of stromal mediation of mammary tumor susceptibility to low dose ionizing radiation (LDIR) using backcrossed F1 into BALB/c (F1Bx) between cancer susceptible (BALB/c) and resistant (SPRET/EiJ) mouse strains. Tumor formation was evaluated after transplantation of non-irradiated Trp53-/- BALB/c mammary gland fragments into cleared fat pads of F1Bx hosts. Genome-wide linkage analysis revealed 2 genetic loci that constitute the baseline susceptibility via host microenvironment. However, once challenged with LDIR, we discovered 13 additional loci that were enriched for genes involved in cytokines, including TGFβ1 signaling. Surprisingly, LDIR-treated F1Bx cohort significantly reduced incidence of mammary tumors from Trp53-/- fragments as well as prolonged tumor latency, compared to sham-treated controls. We demonstrated further that plasma levels of specific cytokines were significantly correlated with tumor latency. Using an ex vivo 3-D assay, we confirmed TGFβ1 as a strong candidate for reduced mammary invasion in SPRET/EiJ, which could explain resistance of this strain to mammary cancer risk following LDIR. Our results open possible new avenues to understand mechanisms of genes operating via the stroma that affect cancer risk from external environmental exposures.

59 BASIC BIOLOGICAL SCIENCES↗

Self-healing SEI enables full-cell cycling of a silicon-majority anode with a coulombic efficiency exceeding 99.9%

Despite active developments, full-cell cycling of Li-battery anodes with >50 wt% Si (a Si-majority anode, SiMA) is rare. The main challenge lies in the solid electrolyte interphase (SEI), which when formed naturally (nSEI), is fragile and cannot tolerate the large volume changes of Si during lithiation/delithiation. An artificial SEI (aSEI) with a specific set of mechanical characteristics is henceforth designed; we enclose Si within a TiO 2 shell thinner than 15 nm, which may or may not be completely hermetic at the beginning. In situ TEM experiments show that the TiO 2 shell exhibits 5× greater strength than an amorphous carbon shell. Void-padded compartmentalization of Si can survive the huge volume changes and electrolyte ingression, with a self-healing aSEI + nSEI. The half-cell capacity exceeds 990 mA h g -1 after 1500 cycles. To improve the volumetric capacity, we further compress SiMA 3-fold from its tap density (0.4 g cm -3 ) to 1.4 g cm -3 , and then run the full-cell battery tests against a 3 mA h cm -2 LiCoO 2 cathode. Despite some TiO 2 enclosures being inevitably broken, 2× the volumetric capacity (1100 mA h cm -3 ) and 2× the gravimetric capacity (762 mA h g -1 ) of commercial graphite anode is achieved in stable full-cell battery cycling, with a stabilized areal capacity of 1.6 mA h cm -2 at the 100th cycle. The initial lithium loss, characterized by the coulombic inefficiency (CI), is carefully tallied on a logarithmic scale and compared with the actual full-cell capacity loss. In conclusion, it is shown that a strong, non-adherent aSEI, even if partially cracked, facilitates an adaptive self-repair mechanism that enables full-cell cycling of a SiMA, leading to a stabilized coulombic efficiency exceeding 99.9%.

25 ENERGY STORAGE↗

Does one need to polish electrodes in an eight pattern? Automation provides the answer

Automation of electrochemical measurements can accelerate the discovery of new electroactive materials. One of the hurdles to automated electrochemical measurement is the pretreatment of electrodes because mechanical polishing is usually conducted manually. Here we investigate the automation of electrochemical measurements using a robotic arm. We demonstrate automated mechanical polishing using a station with a moving polishing pad and evaluate the effect of different polishing patterns. Our automatic method improved the corroded electrodes, and we found the effect of pattern was not significant, which diverges from the current common belief amongst practitioners that a figure eight pattern is best for pretreatment. This research is a step toward automating electrochemistry experiments without human intervention.

Yoshikawa, Naruki [University of Toronto, ON (Cana↗

FABRICATION OF BISMUTH NANOWIRE DEVICES USING FOCUSED ION BEAM MILLING

In this work, a focused ion beam (FIB) milling process has been developed to fabricate 50 nm Bi nanowire and transistor structures using FEI-200 dual beam FIB system. For the fabrication, 50 nm bismuth film was thermally evaporated through EBL patterned PMMA windows onto SiO{sub 2} substrates with pre-defined contact pads. Bi nanowire widths ranging from 30 nm to 100 nm have been successfully fabricated by milling out unwanted areas using 30 KeV Ga+ ion beam. A single-pixel-line ion beam blanking technique has been utilised to fabricate Bi nanowire as small as 30 nm in diameter and few micrometers long. In order to form good ohmic contacts for sub 50 nm bismuth nanowires, a drill-and-fill process has been developed using FIB to sputter away the surface oxide of bismuth after the in-situ platinum nanowire contacts deposition. To our knowledge, this is the first time a focused ion beam process has been used to fabricate bismuth nanowire. The fabricated Bi nanowires were electrically characterised using a semiconductor analyser that showed good ohmic contact to the electrodes. In this paper, the fabrication experiments and the characterisation results for Bi nanowires as small as 50 nm in diameter are presented. Several FIB issues involved in Bi device making and ohmic contacts to Bi nanowires will also be discussed.

36 MATERIALS SCIENCE↗

Punchless Drawing of Magnesium Alloy Sheet under Cold Condition and its Computation

The punchless drawing with Maslennikov's technique was applied to the circular cup drawing of magnesium alloy AZ31B sheet under cold condition. The elastic rubber ring was used instead of the 'hard' punch, where the compressed ring dragged the sheet inward the die cavity. Attainable circumferential strain of the blank was increased by this technique with repetitive drawing operation. Thickness of the rubber pad affected little the attainable strain. The shape appearance became better when a harder rubber was used. The cup forming by single drawing operation was also tested using a small die shoulder radius. The LDR of 1.250 was obtained with the straight cup wall. Further, the computation of the punchless drawing was also conducted for the single drawing operation. The computed deformation pattern was well consistent with the corresponding experimental result.

36 MATERIALS SCIENCE↗

Diffractive physics in ALICE at the LHC

Diffractive and photon induced physics is a research area with a remarkable discovery potential at the LHC. ALICE has started a program to exploit its unique capabilities to study the subject in both proton-proton and heavy ion collisions. We discuss some aspects of a new sub-detector for the ALICE experiment at the LHC. This detector would enhance the performance of ALICE to address some relevant topics on this matter. It consists of four stations of scintillator pads that would tag the diffractive gap more efficiently.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A new detector array for diffractive physics in ALICE at the LHC

We discuss some aspects of a new sub-detector for the ALICE experiment at the LHC. This detector would enhance the capabilities of ALICE to study several topics of diffractive as well as of photon induced physics. It consists of four stations of scintillator pads that would tag the diffractive gap more efficiently.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Overview of Silicon Detectors in STAR: Present and Future

The STAR experiment at RHIC aims to study the QCD phase transition and the origin of the spin of the proton. Its main detector for charged particle track reconstruction is a Time Projection Chamber, which has been supplemented with a silicon detector involving two different technologies, in particular double-sided silicon strip and silicon drift technology. STAR is preparing now for a new Silicon Vertex Detector, using double-sided silicon strip, single-sided silicon strip-pads, and CMOS monolithic active pixel sensors technology, planned to take data in 2014. We give an overview of the design, calibration and performances of the silicon detectors used by the STAR experiment in the past and the expected performances of the future silicon detector upgrade.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Contactless monitoring of Ge content and B concentration in ultrathin single and double layer Si{sub 1-x}Ge{sub x} epitaxial films using multiwavelength micro-Raman spectroscopy

Non-contact monitoring of Ge content and B concentration in single and double Si{sub 1-x}Ge{sub x} epitaxial layers on Si(100) device wafers was attempted using high-resolution, multiwavelength micro-Raman spectroscopy. The Ge content and B concentration determined by secondary ion mass spectroscopy (SIMS) depth profiling showed very strong correlation with the position and full-width-at-half-maximum of the Si-Si peak from the Si{sub 1-x}Ge{sub x} epitaxial layers as determined by Raman measurements. High resolution X-ray diffraction (HRXRD) characterization was done for all wafers to determine Ge and B sensitivity and form comparisons with Raman and SIMS analysis. The non-destructive, in-line monitoring of Ge content and B concentration of single and double Si{sub 1-x}Ge{sub x} epitaxial layers with thickness ranging from 5 {approx} 120 nm, on small area monitoring pads, was successfully demonstrated by multiwavelength micro-Raman spectroscopy during epitaxial process optimization, material property verification, and quality control applications.

36 MATERIALS SCIENCE↗

Picosecond laser structuring of thin film platinum layers covered with tantalum pentoxide isolation

A thin film layer system consisting of platinum (Pt) as conductive layer on a glass substrate and tantalum pentoxide as isolating layer on top of the platinum is attractive for designing biocompatible conductor paths and contact pads for bio sensor chips. For the flexible and rapid patterning of the conductive and the isolating layers, both, the complete removal and the selective ablation of the individual thin films were investigated using ultra-short laser pulses with about 10 ps pulse duration and 1064 nm wavelength at low laser fluences. A platinum film covered with tantalum pentoxide shows a significantly lower ablation threshold than a single Pt film on glass alone when illuminated from the front side. Furthermore, we explored that the tantalum pentoxide film can be removed by glass side illumination from the Pt film, without affecting the Pt film and leaving the Pt film on the glass substrate intact. Those ablation phenomena occur at laser fluences of about 0.2 J/cm{sup 2}, far below the evaporation limit of platinum. We present a detailed ablation threshold value examination for the structuring of these layer systems by front side and glass side irradiation for different film thicknesses. Furthermore, we discuss the possible underlying physical mechanisms of these ablation phenomena.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Intermetallic compound formation at Cu-Al wire bond interface

Intermetallic compound (IMC) formation and evolution at Cu-Al wire bond interface were studied using focused ion beam /scanning electron microscopy, transmission electron microscopy (TEM)/energy dispersive x-ray spectroscopy (EDS), nano beam electron diffraction (NBED) and structure factor (SF) calculation. It was found that discrete IMC patches were formed at the Cu/Al interface in as-packaged state and they grew toward Al pad after high temperature storage (HTS) environment at 150 Degree-Sign C. TEM/EDS and NBED results combined with SF calculation revealed the evidence of metastable {theta} Prime -CuAl{sub 2} IMC phase (tetragonal, space group: I4m2, a = 0.404 nm, c= 0.580 nm) formed at Cu/Al interfaces in both of the as-packaged and the post-HTS samples. Two feasible mechanisms for the formation of the metastable {theta} Prime -CuAl{sub 2} phase are discussed based on (1) non-equilibrium cooling of wire bond that is attributed to highly short bonding process time and (2) the epitaxial relationships between Cu and {theta} Prime -CuAl{sub 2}, which can minimize lattice mismatch for {theta} Prime -CuAl{sub 2} to grow on Cu.

36 MATERIALS SCIENCE↗

A self-reconfiguring metamorphic nanoinjector for injection into mouse zygotes

This paper presents a surface-micromachined microelectromechanical system nanoinjector designed to inject DNA into mouse zygotes which are ≈90 μm in diameter. The proposed injection method requires that an electrically charged, DNA coated lance be inserted into the mouse zygote. The nanoinjector's principal design requirements are (1) it must penetrate the lance into the mouse zygote without tearing the cell membranes and (2) maintain electrical connectivity between the lance and a stationary bond pad. These requirements are satisfied through a two-phase, self-reconfiguring metamorphic mechanism. In the first motion subphase a change-point six-bar mechanism elevates the lance to ≈45 μm above the substrate. In the second motion subphase, a compliant folded-beam suspension allows the lance to translate in-plane at a constant height as it penetrates the cell membranes. The viability of embryos following nanoinjection is presented as a metric for quantifying how well the nanoinjector mechanism fulfills its design requirements of penetrating the zygote without causing membrane damage. Viability studies of nearly 3000 nanoinjections resulted in 71.9% of nanoinjected zygotes progressing to the two-cell stage compared to 79.6% of untreated embryos.

60 APPLIED LIFE SCIENCES↗

Metal-oxide-semiconductor capacitors and Schottky diodes studied with scanning microwave microscopy at 18 GHz

We measured the DC and RF impedance characteristics of micrometric metal-oxide-semiconductor (MOS) capacitors and Schottky diodes using scanning microwave microscopy (SMM). The SMM consisting of an atomic force microscopy (AFM) interfaced with a vector network analyser (VNA) was used to measure the reflection S11 coefficient of the metallic MOS and Schottky contact pads at 18 GHz as a function of the tip bias voltage. By controlling the SMM biasing conditions, the AFM tip was used to bias the Schottky contacts between reverse and forward mode. In reverse bias direction, the Schottky contacts showed mostly a change in the imaginary part of the admittance while in forward bias direction the change was mostly in the real part of the admittance. Reference MOS capacitors which are next to the Schottky diodes on the same sample were used to calibrate the SMM S11 data and convert it into capacitance values. Calibrated capacitance between 1–10 fF and 1/C{sup 2} spectroscopy curves were acquired on the different Schottky diodes as a function of the DC bias voltage following a linear behavior. Additionally, measurements were done directly with the AFM-tip in contact with the silicon substrate forming a nanoscale Schottky contact. Similar capacitance-voltage curves were obtained but with smaller values (30–300 aF) due to the corresponding smaller AFM-tip diameter. Calibrated capacitance images of both the MOS and Schottky contacts were acquired with nanoscale resolution at different tip-bias voltages.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Contact resistance and overlapping capacitance in flexible sub-micron long oxide thin-film transistors for above 100 MHz operation

In recent years new forms of electronic devices such as electronic papers, flexible displays, epidermal sensors, and smart textiles have become reality. Thin-film transistors (TFTs) are the basic blocks of the circuits used in such devices and need to operate above 100 MHz to efficiently treat signals in RF systems and address pixels in high resolution displays. Beyond the choice of the semiconductor, i.e., silicon, graphene, organics, or amorphous oxides, the junctionless nature of TFTs and its geometry imply some limitations which become evident and important in devices with scaled channel length. Furthermore, the mechanical instability of flexible substrates limits the feature size of flexible TFTs. Contact resistance and overlapping capacitance are two parasitic effects which limit the transit frequency of transistors. They are often considered independent, while a deeper analysis of TFTs geometry imposes to handle them together; in fact, they both depend on the overlapping length (L{sub OV}) between source/drain and the gate contacts. Here, we conduct a quantitative analysis based on a large number of flexible ultra-scaled IGZO TFTs. Devices with three different values of overlap length and channel length down to 0.5 μm are fabricated to experimentally investigate the scaling behavior of the transit frequency. Contact resistance and overlapping capacitance depend in opposite ways on L{sub OV}. These findings establish routes for the optimization of the dimension of source/drain contact pads and suggest design guidelines to achieve megahertz operation in flexible IGZO TFTs and circuits.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Silicon detectors for monitoring neutron beams in n-TOF beamlines

During 2014, the second experimental area (EAR2) was completed at the n-TOF neutron beam facility at CERN (n-TOF indicates neutron beam measurements by means of time of flight technique). The neutrons are produced via spallation, by means of a high-intensity 20 GeV pulsed proton beam impinging on a thick target. The resulting neutron beam covers the energy range from thermal to several GeV. In this paper, we describe two beam diagnostic devices, both exploiting silicon detectors coupled with neutron converter foils containing {sup 6}Li. The first one is based on four silicon pads and allows monitoring of the neutron beam flux as a function of the neutron energy. The second one, in beam and based on position sensitive silicon detectors, is intended for the reconstruction of the beam profile, again as a function of the neutron energy. Several electronic setups have been explored in order to overcome the issues related to the gamma flash, namely, a huge pulse present at the start of each neutron bunch which may blind the detectors for some time. The two devices were characterized with radioactive sources and also tested at the n-TOF facility at CERN. The wide energy and intensity range they proved capable of sustaining made them attractive and suitable to be used in both EAR1 and EAR2 n-TOF experimental areas, where they became immediately operational.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of electrical-erosion instrument for direct write micro-patterning on large area conductive thin films

We have developed a complete instrument to perform direct, dry, and cost-effective lithography on conductive materials, based on localized electrical discharges, which avoids using masks or chemicals typical of conventional photolithography. The technique is considered fully compatible with substrate transport based systems, like roll-to-roll technology. The prototype is based on two piezo nano-steppers coupled to three linear micro-stages to cover a large scale operation from micrometers to centimeters. The operation mode consists of a spring probe biased at low DC voltage with respect to a grounded conductive layer. The tip slides on the target layer keeping contact with the material in room conditions, allowing continuous electric monitoring of the process, and also real-time tilt correction via software. The sliding tip leaves an insulating path (limited by the tip diameter) along the material, enabling to draw electrically insulated tracks and pads. The physical principle of operation is based in the natural self-limitation of the discharge due to material removal or insulation. The so produced electrical discharges are very fast, in the range of μs, so features may be performed at speeds of few cm/s, enabling scalability to large areas. The instrument has been tested on different conducting materials as gold, indium tin oxide, and aluminum, allowing the fabrication of alphanumeric displays based on passive matrix of organic light emitting diodes without the use of masks or photoresists. We have verified that the highest potential is achieved on graphene, where no waste material is detected, producing excellent well defined edges. This allows manufacturing graphene micro-ribbons with a high aspect ratio up to 1200:1.

36 MATERIALS SCIENCE↗

In situ resistivity of endotaxial FeSi{sub 2} nanowires on Si(110)

We present in situ ultra-high vacuum measurements of the resistivity ρ of self-assembled endotaxial FeSi{sub 2} nanowires (NWs) on Si(110) using a variable-spacing two-point method with a moveable scanning tunneling microscope tip and fixed contact pad. The resistivity at room temperature was found to be nearly constant down to NW width W = 4 nm, but rose sharply to nearly double the bulk value at W = 3 nm. These data are not well-fit by a simple Fuch-Sondheimer model for boundary scattering, suggesting that other factors, possibly quantum effects, may be significant at the smallest dimensions. For a NW width of 4 nm, partial oxidation increased ρ by approximately 50%, while cooling from 300 K to 150 K decreased ρ by approximately 10%. The relative insensitivity of ρ to NW size or oxidation or cooling is attributed to a high concentration of vacancies in the FeSi{sub 2} structure, with a correspondingly short length for inelastic electron scattering, which obscures boundary scattering except in the smallest NWs. It is remarkable that the vacancy concentration persists in very small structures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗