Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Optically detected, single nanoparticle mass spectrometer with pre-filtered electrospray nanoparticle source

An instrument designed for non-destructive mass analysis of single trapped nanoparticles is described. The heart of the instrument is a 3D quadrupole (Paul) trap constructed to give optical access to the trap center along ten directions, allowing passage of lasers for particle heating and detection, particle injection, collection of scattered or fluorescent photons for particle detection and mass analysis, and collection of particles on TEM grids for analysis, as needed. Nanoparticles are injected using an electrospray ionization (ESI) source, and conditions are described for spraying and trapping polymer particles, bare metal particles, and ligand stabilized particles with masses ranging from 200 kDa to >3 GDa. Conditions appropriate to ESI and injection of different types of particles are described. The instrument is equipped with two ion guides separating the ESI source and nanoparticle trap. The first ion guide is mostly to allow desolvation and differential pumping before the particles enter the trap section of the instrument. The second is a linear quadrupole guide, which can be operated in mass selective or mass band-pass modes to limit transmission to species with mass-to-charge ratios in the range of interest. With a little experience, the design allows injection of single particles into the trap upon demand.

36 MATERIALS SCIENCE↗

Detecting chaos in particle accelerators through the frequency map analysis method

The motion of beams in particle accelerators is dominated by a plethora of non-linear effects, which can enhance chaotic motion and limit their performance. The application of advanced non-linear dynamics methods for detecting and correcting these effects and thereby increasing the region of beam stability plays an essential role during the accelerator design phase but also their operation. After describing the nature of non-linear effects and their impact on performance parameters of different particle accelerator categories, the theory of non-linear particle motion is outlined. The recent developments on the methods employed for the analysis of chaotic beam motion are detailed. In particular, the ability of the frequency map analysis method to detect chaotic motion and guide the correction of non-linear effects is demonstrated in particle tracking simulations but also experimental data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The impact of detection rate changes and correlations on random-coincidence background measurements

Coincidence detection of multiple particles emitted during an experiment can yield a new depth of understanding of the underlying process under study. However, the probability of detecting particles that are generated from the same physical event within a given coincidence time window is generally much lower than that of detecting particles that appear in the same coincidence time window, but were not created from the same physical event, and are therefore detected randomly in coincidence with each other. Thus, accurate and precise methods of measuring this random-coincidence background are essential for a wide variety of fields of science. A method to determine this background directly using the data themselves without any additional experimental run time or fake signals introduced in the data was recently established (O’Donnell, 2016). This method yields a statistical uncertainty on the random-coincidence background that is orders of magnitude smaller than that of the true coincidence data, though the potential for systematic errors of backgrounds from this method was never explored. In this work, we discuss common varieties of correlated and uncorrelated changes in the detection rates of each particle detected in an experiment. Here we demonstrate here that a correlation between particle detection rates from, for example, an incident particle beam that initiates a physical process of interest, creates systematic errors in the random-coincidence background measurement. We also discuss the impact of a variety of other realistic scenarios for rate changes in experiments. Lastly, a method is introduced to correct for errors in the random-coincidence background from any source, yielding an optimization between statistical precision and eliminating potential lingering systematic errors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of Saturn ring particles on Pioneer 11

The detection of particles near the rings of Saturn by the meteoroid detection instrument on board Pioneer 11 is discussed. The instrument consists of 234 penetration detectors, distributed between two independent data channels each of which is designed to become inhibited for a period of 77 min after the registration of a penetration event in that channel. At least four particles penetrated the detectors in the 4.5 h period around Saturn periapsis at radial distances between 1.36 and 3.1 Saturn radii, a radial distribution inconsistent with the gravitational focusing of meteoroids. The detection of particles which may have been part of the E ring before the crossing of the ring plane suggests that this ring may be 1800 km thick, with an optical thickness greater than 10 to the -8th.

Humes, D. H.↗

Elementary Ion Optics with Applications to Electromagnetic Spectrometers

This lecture, intended for physics graduate students, represents an introduction to ion optics with applications to the electromagnetic spectrometers used in nuclear astrophysics research. A particular radiative capture reaction is chosen to illustrate the requirements of such spectrometers.

43 PARTICLE ACCELERATORS↗

Study of the characteristics of a piezoelectric lead zirconate titanate radiation detector using a pulsed xenon source

The detector characteristics of piezoelectric lead zirconate titanate (PZT) were studied by directly irradiating a multilayered PZT detector with 400 MeV/n xenon ions. An extracted beam was processed with a rotating slit. Thus, passed through {approx}10{sup 3} xenon ions were available for 50 to 250 {mu}s. The effect of polarization on the output signal was discussed, and the optimal electrode configuration was determined. The output signal appeared as an isolated pulse whose amplitude was qualitatively understood by the Bethe-Bloch formula. However, the calculated and the observed values differed depending on the rotation speed of the slit. A process that can explain the differences is presented here. The output signal appearing beyond the range of 400 MeV/n xenon ion beam was discussed. The sensitivity was compared with that obtained with hypervelocity collision of dust.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of preferential particle orientation in the atmosphere. Development of an alternative polarization lidar system

Increasing interest in polarimetric characterization of atmospheric aerosols has led to the development of complete sample-measuring (Mueller) polarimeters that are capable of measuring the entire backscattering phase matrix of a probed volume. The Mueller polarimeters consist of several moving parts, which limit measurement rates and complicate data analysis. In this paper, we present the concept of a less complex polarization lidar setup for detection of preferential orientation of atmospheric particulates. On the basis of theoretical considerations of data inversion stability and propagation of measurement uncertainties, an optimum optical configuration is established for two modes of operation (with either a linear or a circular polarized incident laser beam). We discovered that the conceptualized setup falls in the category of incomplete sample-measuring polarimeters and uses four detection channels for simultaneous measurement of the backscattered light. Likewise, the expected performance characteristics are discussed through an example of a typical aerosol with a small fraction of particles oriented in a preferred direction. As a result, the theoretical analysis suggests that achievable accuracies in backscatter cross-sections and depolarization ratios are similar to those with conventional two-channel configurations, while in addition preferential orientation can be detected with the proposed four-channel system for a wide range of conditions.

43 PARTICLE ACCELERATORS↗

Development of a Time-tagged Neutron Source for SNM Detection

Associated particle imaging (API) is a powerful technique for special nuclear material (SNM) detection and characterization of fissile material configurations. A sealed-tube neutron generator has been under development by Lawrence Berkeley National Laboratory to reduce the beam spot size on the neutron production target to 1 mm in diameter for a several-fold increase in directional resolution and simultaneously increases the maximum attainable neutron flux. A permanent magnet 2.45 GHz microwave-driven ion source has been adopted in this time-tagged neutron source. This type of ion source provides a high plasma density that allows the use of a sub-millimeter aperture for the extraction of a sufficient ion beam current and lets us achieve a much reduced beam spot size on target without employing active focusing. The design of this API generator uses a custom-made radial high voltage insulator to minimize source to neutron production target distance and to provide for a simple ion source cooling arrangement. Preliminary experimental results showed that more than 100 µA of deuterium ions have been extracted, and the beam diameter on the neutron production target is around 1 mm.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modeling and Detection of Ice Particle Accretion in Aircraft Engine Compression Systems

The accretion of ice particles in the core of commercial aircraft engines has been an ongoing aviation safety challenge. While no accidents have resulted from this phenomenon to date, numerous engine power loss events ranging from uneventful recoveries to forced landings have been recorded. As a first step to enabling mitigation strategies during ice accretion, a detection scheme must be developed that is capable of being implemented on board modern engines. In this paper, a simple detection scheme is developed and tested using a realistic engine simulation with approximate ice accretion models based on data from a compressor design tool. These accretion models are implemented as modified Low Pressure Compressor maps and have the capability to shift engine performance based on a specified level of ice blockage. Based on results from this model, it is possible to detect the accretion of ice in the engine core by observing shifts in the typical sensed engine outputs. Results are presented in which, for a 0.1 percent false positive rate, a true positive detection rate of 98 percent is achieved.

May, Ryan D.↗

Particle and Smoke Detection on ISS for Next Generation Smoke Detectors

Rapid fire detection requires the ability to differentiate fire signatures from background conditions and nuisance sources. Proper design of a fire detector requires detailed knowledge of all of these signal sources so that a discriminating detector can be designed. Owing to the absence of microgravity smoke data, all current spacecraft smoke detectors were designed based upon normal-g conditions. The removal of buoyancy reduces the velocities in the high temperature zones in flames, increasing the residence time of smoke particles and consequently allowing longer growth time for the particles. Recent space shuttle experiments confirmed that, in some cases, increased particles sizes are seen in low-gravity and that the relative performance of the ISS (International Space Station) and space-shuttle smoke-detectors changes in low-gravity; however, sufficient particle size information to design new detectors was not obtained. To address this issue, the SAME (Smoke Aerosol Measurement Experiment) experiment is manifested to fly on the ISS in 2007. The SAME experiment will make measurements of the particle size distribution of the smoke particulate from several typical spacecraft materials providing quantitative design data for spacecraft smoke detectors. A precursor experiment (DAFT: Dust Aerosol measurement Feasibility Test) flew recently on the ISS and provided the first measurement of the background smoke particulate levels on the ISS. These background levels are critical to the design of future smoke detectors. The ISS cabin was found to be a very clean environment with particulate levels substantially below the space shuttle and typical ground-based environments.

Urban, David L.↗

Simulation for Iron Calorimeter prototype detector of India-based Neutrino Observatory

The India-based Neutrino Observatory (INO) collaboration is proposing to build a 50 kton magnetized iron calorimeter (ICAL) detector in an underground laboratory to be located in South India. As a first step towards building the ICAL detector, a 35 ton prototype of the same design has been set up on the surface to track cosmic ray muons. This paper discusses the prototype detector geometry simulation by GEANT4, and the detector response to the cosmic muons. We have developed a track fitting procedure based on the Kalman Filter technique for the prototype detector when the detector is exposed to single muon tracks. The relevant track parameters i.e., momentum, direction and charge are reconstructed and analyzed. Finally we show the resolution of reconstructed momenta.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of an ultra low power CMOS pixel sensor for a future neutron personal dosimeter

Despite a continuously increasing demand, neutron electronic personal dosimeters (EPDs) are still far from being completely established because their development is a very difficult task. A low-noise, ultra low power consumption CMOS pixel sensor for a future neutron personal dosimeter has been implemented in a 0.35 {mu}m CMOS technology. The prototype is composed of a pixel array for detection of charged particles, and the readout electronics is integrated on the same substrate for signal processing. The excess electrons generated by an impinging particle are collected by the pixel array. The charge collection time and the efficiency are the crucial points of a CMOS detector. The 3-D device simulations using the commercially available Synopsys-SENTAURUS package address the detailed charge collection process. Within a time of 1.9 {mu}s, about 59% electrons created by the impact particle are collected in a cluster of 4 x 4 pixels with the pixel pitch of 80 {mu}m. A charge sensitive preamplifier (CSA) and a shaper are employed in the frond-end readout. The tests with electrical signals indicate that our prototype with a total active area of 2.56 x 2.56 mm{sup 2} performs an equivalent noise charge (ENC) of less than 400 e - and 314 {mu}W power consumption, leading to a promising prototype. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of Gas Solid Fluidized Bed Dynamics with Non-Spherical Particles

One of the largest challenges for 21st century is to fulfill global energy demand while also reducing detrimental impacts of energy generation and use on the environment. Gasification is a promising technology to meet the requirement of reduced emissions without compromising performance. Coal gasification is not an incinerating process; rather than burning coal completely a partial combustion takes place in the presence of steam and limited amounts of oxygen. In this controlled environment, a chemical reaction takes place to produce a mixture of clean synthetic gas. Gas-solid fluidized bed is one such type of gasification technology. During gasification, the mixing behavior of solid (coal) and gas and their flow patterns can be very complicated to understand. Many attempts have taken place in laboratory scale to understand bed hydrodynamics with spherical particles though in actual applications with coal, the particles are non-spherical. This issue drove the documented attempt presented here to investigate fluidized bed behavior using different ranges of non-spherical particles, as well as spherical. For this investigation, various parameters are controlled that included particle size, bed height, bed diameter and particle shape. Particles ranged from 355 µm to 1180 µm, bed diameter varied from 2 cm to 7 cm, two fluidized beds with diameters of 3.4 cm and 12.4 cm, for the spherical and non-spherical shaped particles that were taken into consideration. Pressure drop was measured with increasing superficial gas velocity. The velocity required in order to start to fluidize the particle is called the minimum fluidization velocity, which is one of the most important parameters to design and optimize within a gas-solid fluidized bed. This minimum fluidization velocity was monitored during investigation while observing variables factors and their effect on this velocity. From our investigation, it has been found that minimum fluidization velocity is independent of bed height for both spherical and non-spherical particles. Further, it decrease with decreasing particle size and decreases with decreasing bed diameter. Shadow sizing, a non-intrusive imaging and diagnostic technology, was also used to visualize flow fields inside fluidized beds for both spherical and non- spherical particles and to detect the particle sizes.

09 BIOMASS FUELS↗

ATS-6 - UCSD auroral particles experiment

The University of California at San Diego Auroral Particles Experiment aboard Applications Technology Satellite-6 (ATS-6) is discussed. The experiment is designed to investigate the time development of geomagnetic substorm particles, the confinement and loss of such particles, and the roles of plasma wave instabilities and characteristic system periodicities in substorm and general magnetospheric processes. The instrumentation includes a complement of five electrostatic charged particle detectors. Two detector assemblies are capable of rotation through 220 deg. The electrostatic curved plate energy/unit charge analyzers are ovoid, requiring particles to be bent only 55 deg to obtain azimuthal focusing. The inside of the plates is serrated to eliminate particles striking the sides. A post-analysis electrostatic lens consisting of two wire grids, one at the potential of the inner plate and one at the potential of ground, focuses particles strongly upon the center of the sensor. A spiraltron particle sensor detects the charged particles. The system has an energy range of five orders of magnitude with a lower extreme of less than 1 eV. Preliminary data are presented to illustrate phenomena which are observed as a result of the novel features described.

Mauk, B. H.↗