Search NASA⌕ Search

SEARCH · Search NASA

Results for “Patient Support System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

MO-FG-BRC-01: MR-Guided Radiation Therapy with Gadolinium Nanoparticles: From Chalkboard to First Clinical Trials

Experimental research in medical physics has expanded the limits of our knowledge and provided novel imaging and therapy technologies for patients around the world. However, experimental efforts are challenging due to constraints in funding, space, time and other forms of institutional support. In this joint ESTRO-AAPM symposium, four exciting experimental projects from four different countries are highlighted. Each project is focused on a different aspect of radiation therapy. From the USA, we will hear about a new linear accelerator concept for more compact and efficient therapy devices. From Canada, we will learn about novel linear accelerator target design and the implications for imaging and therapy. From France, we will discover a mature translational effort to incorporate theranostic nanoparticles in MR-guided radiation therapy. From Germany, we will find out about a novel in-treatment imaging modality for particle therapy. These examples of high impact, experimental medical physics research are representative of the diversity of such efforts that are on-going around the globe. J. Robar, Research is supported through collaboration with Varian Medical Systems and Brainlab AGD. Westerly, This work is supported by the Department of Radiation Oncology at the University of Colorado School of Medicine. COI: NONEK. Parodi, Part of the presented work is supported by the DFG (German Research Foundation) Cluster of Excellence MAP (Munich-Centre for Advanced Photonics) and has been carried out in collaboration with IBA.

60 APPLIED LIFE SCIENCES↗

MO-FG-BRC-02: Low-Z Switching Linear Accelerator Targets: New Options for Image Guidance and Dose Enhancement in Radiotherapy

Experimental research in medical physics has expanded the limits of our knowledge and provided novel imaging and therapy technologies for patients around the world. However, experimental efforts are challenging due to constraints in funding, space, time and other forms of institutional support. In this joint ESTRO-AAPM symposium, four exciting experimental projects from four different countries are highlighted. Each project is focused on a different aspect of radiation therapy. From the USA, we will hear about a new linear accelerator concept for more compact and efficient therapy devices. From Canada, we will learn about novel linear accelerator target design and the implications for imaging and therapy. From France, we will discover a mature translational effort to incorporate theranostic nanoparticles in MR-guided radiation therapy. From Germany, we will find out about a novel in-treatment imaging modality for particle therapy. These examples of high impact, experimental medical physics research are representative of the diversity of such efforts that are on-going around the globe. J. Robar, Research is supported through collaboration with Varian Medical Systems and Brainlab AGD. Westerly, This work is supported by the Department of Radiation Oncology at the University of Colorado School of Medicine. COI: NONEK. Parodi, Part of the presented work is supported by the DFG (German Research Foundation) Cluster of Excellence MAP (Munich-Centre for Advanced Photonics) and has been carried out in collaboration with IBA.

60 APPLIED LIFE SCIENCES↗

MO-FG-BRC-03: Design and Construction of a Dielectiric Wall Accelerator

Experimental research in medical physics has expanded the limits of our knowledge and provided novel imaging and therapy technologies for patients around the world. However, experimental efforts are challenging due to constraints in funding, space, time and other forms of institutional support. In this joint ESTRO-AAPM symposium, four exciting experimental projects from four different countries are highlighted. Each project is focused on a different aspect of radiation therapy. From the USA, we will hear about a new linear accelerator concept for more compact and efficient therapy devices. From Canada, we will learn about novel linear accelerator target design and the implications for imaging and therapy. From France, we will discover a mature translational effort to incorporate theranostic nanoparticles in MR-guided radiation therapy. From Germany, we will find out about a novel in-treatment imaging modality for particle therapy. These examples of high impact, experimental medical physics research are representative of the diversity of such efforts that are on-going around the globe. J. Robar, Research is supported through collaboration with Varian Medical Systems and Brainlab AGD. Westerly, This work is supported by the Department of Radiation Oncology at the University of Colorado School of Medicine. COI: NONEK. Parodi, Part of the presented work is supported by the DFG (German Research Foundation) Cluster of Excellence MAP (Munich-Centre for Advanced Photonics) and has been carried out in collaboration with IBA.

60 APPLIED LIFE SCIENCES↗

MO-FG-BRC-04: Ionacoustic Imaging for Particle Range Verification

Experimental research in medical physics has expanded the limits of our knowledge and provided novel imaging and therapy technologies for patients around the world. However, experimental efforts are challenging due to constraints in funding, space, time and other forms of institutional support. In this joint ESTRO-AAPM symposium, four exciting experimental projects from four different countries are highlighted. Each project is focused on a different aspect of radiation therapy. From the USA, we will hear about a new linear accelerator concept for more compact and efficient therapy devices. From Canada, we will learn about novel linear accelerator target design and the implications for imaging and therapy. From France, we will discover a mature translational effort to incorporate theranostic nanoparticles in MR-guided radiation therapy. From Germany, we will find out about a novel in-treatment imaging modality for particle therapy. These examples of high impact, experimental medical physics research are representative of the diversity of such efforts that are on-going around the globe. J. Robar, Research is supported through collaboration with Varian Medical Systems and Brainlab AGD. Westerly, This work is supported by the Department of Radiation Oncology at the University of Colorado School of Medicine. COI: NONEK. Parodi, Part of the presented work is supported by the DFG (German Research Foundation) Cluster of Excellence MAP (Munich-Centre for Advanced Photonics) and has been carried out in collaboration with IBA.

60 APPLIED LIFE SCIENCES↗

TH-AB-201-01: A Feasibility Study of Independent Dose Verification for CyberKnife

Purpose: CyberKnife irradiation is composed of tiny-size, multiple and intensity-modulated beams compared to conventional linacs. Few of the publications for Independent dose calculation verification for CyberKnife have been reported. In this study, we evaluated the feasibility of independent dose verification for CyberKnife treatment as Secondary check. Methods: The followings were measured: test plans using some static and single beams, clinical plans in a phantom and using patient’s CT. 75 patient plans were collected from several treatment sites of brain, lung, liver and bone. In the test plans and the phantom plans, a pinpoint ion-chamber measurement was performed to assess dose deviation for a treatment planning system (TPS) and an independent verification program of Simple MU Analysis (SMU). In the clinical plans, dose deviation between the SMU and the TPS was performed. Results: In test plan, the dose deviations were 3.3±4.5%, and 4.1±4.4% for the TPS and the SMU, respectively. In the phantom measurements for the clinical plans, the dose deviations were −0.2±3.6% for the TPS and −2.3±4.8% for the SMU. In the clinical plans using the patient’s CT, the dose deviations were −3.0±2.1% (Mean±1SD). The systematic difference was partially derived from inverse square law and penumbra calculation. Conclusion: The independent dose calculation for CyberKnife shows −3.0±4.2% (Mean±2SD) and our study, the confidence limit was achieved within 5% of the tolerance level from AAPM task group 114 for non-IMRT treatment. Thus, it may be feasible to use independent dose calculation verification for CyberKnife treatment as the secondary check. This research is partially supported by Japan Agency for Medical Research and Development (AMED)

60 APPLIED LIFE SCIENCES↗

A reevaluation of the vestibulo-ocular reflex: new ideas of its purpose, properties, neural substrate, and disorders

Conventional views of the vestibulo-ocular reflex (VOR) have emphasized testing with caloric stimuli and by passively rotating patients at low frequencies in a chair. The properties of the VOR tested under these conditions differ from the performance of this reflex during the natural function for which it evolved--locomotion. Only the VOR (and not visually mediated eye movements) can cope with the high-frequency angular and linear perturbations of the head that occur during locomotion; this is achieved by generating eye movements at short latency (< 16 msec). Interpretation of vestibular testing is enhanced by the realization that, although the di- and trisynaptic components of the VOR are essential for this short-latency response, the overall accuracy and plasticity of the VOR depend upon a distributed, parallel network of neurons involving the vestibular nuclei. Neurons in this network variously upon a distributed, parallel network of neurons involving the vestibular nuclei. Neurons in this network variously encode inputs from the labyrinthine semicircular canals and otoliths, as well as from the visual and somatosensory systems. The central vestibular pathways branch to contact vestibular cortex (for perception) and the spinal cord (for control of posture). Thus, the vestibular nuclei basically coordinate the stabilization of gaze and posture, and contribute to the perception of verticality and self-motion. Consequently, brainstem disorders that disrupt the VOR cause not just only nystagmus, but also instability of posture (eg, increased fore-aft sway in patients with downbeat nystagmus) and disturbance of spatial orientation (eg, tilt of the subjective visual vertical in Wallenberg's syndrome).

Review↗

Earthbound applications for NASA's physician workstation

The dream of a space probe to Mars or an astronaut colony on the moon persists. Despite years of setbacks and delays, NASA continues to lay the foundation for a new frontier in space. The necessity of a self contained health maintenance facility is an integral part of this stellar venture. As a subsystem of this health maintenance facility, the physician or astronaut workstation was envisioned as the vehicle of interface between the computer resources of the space station and the care provider. Our efforts to define and build this interface have resulted in a series of programs which can now be tested and refined using earth-based applications. The modules which have dual-use application from the NASA workstation include: patient scheduling and master patient index, pharmacy, laboratory, medical library, problem list/progress notes, and digital medical records. Our current plan is to develop these tools as objects that can be assembled in a variety of configurations. This will allow the technology to be used by the private sector where each doctor can select the starting point of his outpatient office system and add modules as he makes progress in system integration and training.

NASA Discipline Number 70-30↗

Comparison of Favorable Early-Stage Hodgkin's Lymphoma Treatments: A Single-Institution Review

Purpose: To compare outcomes of patients receiving combined-modality chemotherapy and radiation (CMT) vs. other approaches for early-stage Hodgkin's lymphoma (HL). Methods and Materials: A review of patients with nonbulky, early-stage (IA/IIA) HL treated between 1984 and 2002 was performed to determine the treatment approaches used and the outcomes obtained. Results: There were 173 adult patients with newly diagnosed early-stage HL (49% men, 51% women, median age 33 [range 17-82] years). Treatment was as follows: extended-field radiotherapy alone (EFRT) 49%; chemotherapy alone (CTA) 13%; and CMT 38%. Among CMT patients, 36% received abbreviated doxorubicin, bleomycin, vinblastine, and dacarbazine chemotherapy (three to four cycles) followed by involved-field radiotherapy. With a median follow-up of 8.3 years, the estimated 10-year relapse-free survival (RFS) and overall survival (OS) rates for the entire cohort were 78% and 85%, respectively. The 10-year RFS and OS rates for the various groups were as follows: 69% and 81% for EFRT; 78% and 84% for CTA; and 87% and 89% for CMT. The 10-year RFS rate was significantly higher (p < 0.01) among CMT patients. The use of EFRT has diminished from approximately 90% in the 1980s to virtually no use at present, whereas the use of CTA and CMT has increased significantly (p < 0.01). Conclusion: Early-stage HL treatment has changed dramatically over the past 2 decades, and our results support the superiority and continued use of CMT, specifically abbreviated-course chemotherapy and involved-field radiotherapy, as an appropriate treatment approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A second‐generation virtual‐pinhole PET device for enhancing contrast recovery and improving lesion detectability of a whole‐body PET/CT scanner

Purpose We have developed a second‐generation virtual‐pinhole (VP) positron emission tomography (PET) device that can position a flat‐panel PET detector around a patient's body using a robotic arm to enhance the contrast recovery coefficient (CRC) and detectability of lesions in any region‐of‐interest using a whole‐body PET/computed tomography (CT) scanner. Methods We constructed a flat‐panel VP‐PET device using 32 high‐resolution detectors, each containing a 4 4 MPPC array and 16 16 LYSO crystals of 1.0 1.0 3.0 mm 3 each. The flat‐panel detectors can be positioned around a patient's body anywhere in the imaging field‐of‐view (FOV) of a Siemens Biograph 40 PET/CT scanner by a robotic arm. New hardware, firmware and software have been developed to support the additional detector signals without compromising a scanner's native functions. We stepped a 22 Na point source across the axial FOV of the scanner to measure the sensitivity profile of the VP‐PET device. We also recorded the coincidence events measured by the scanner detectors and by the VP‐PET detectors when imaging phantoms of different sizes. To assess the improvement in the CRC of small lesions, we imaged an elliptical torso phantom measuring 316 228 162 mm 3 that contains spherical tumors with diameters ranging from 3.3 to 11.4 mm with and without the VP‐PET device. Images were reconstructed using a list mode Maximum‐Likelihood Estimation‐Maximization algorithm implemented on multiple graphics processing units (GPUs) to support the unconventional geometries enabled by a VP‐PET system. The mean and standard deviation of the CRC were calculated for tumors of different sizes. Monte Carlo simulation was also conducted to image clusters of lesions in a torso phantom using a PET/CT scanner alone or the same scanner equipped with VP‐PET devices. Receiver operating characteristic (ROC) curves were analyzed for three system configurations to evaluate the improvement in lesion detectability by the VP‐PET device over the native PET/CT scanner. Results The repeatability in positioning the flat‐panel detectors using a robotic arm is better than 0.15 mm in all three directions. Experimental results show that the average CRC of 3.3, 4.3, and 6.0 mm diameter tumors was 0.82%, 2.90%, and 5.25%, respectively, when measured by the native scanner. The corresponding CRC was 2.73%, 6.21% and 10.13% when imaged by the VP‐PET insert device with the flat‐panel detector under the torso phantom. These values may be further improved to 4.31%, 9.65% and 18.01% by a future dual‐panel VP‐PET insert device if DOI detectors are employed to triple its detector efficiency. Monte Carlo simulation results show that the tumor detectability can be improved by a VP‐PET device that has a single flat‐panel detector. The improvement is greater if the VP‐PET device employs a dual‐panel design. Conclusions We have developed a prototype flat‐panel VP‐PET device and integrated it with a clinical PET/CT scanner. It significantly enhances the contrast of lesions, especially for those that are borderline detectable by the native scanner, within regions‐of‐interest specified by users. Simulation demonstrated the enhancement in lesion detectability with the VP‐PET device. This technology may become a cost‐effective solution for organ‐specific imaging tasks.

Jiang, Jianyong↗

Malignant vagotonia due to selective baroreflex failure

Baroreflex failure is characterized by dramatic fluctuations of sympathetic activity and paroxysms of hypertension and tachycardia. In contrast, unopposed parasympathetic activity has not been described in patients with baroreflex failure because of concurrent parasympathetic denervation of the heart. We describe the unusual case of a patient with baroreflex failure in a setting of preserved parasympathetic control of HR manifesting episodes of severe bradycardia and asystole. Thus, parasympathetic control of the HR may be intact in occasional patients with baroreflex failure. Patients with this selective baroreflex failure require a unique therapeutic strategy for the control of disease manifestations.

Case Reports↗

SU-F-BRD-11: A Virtual Simulator Designed for Collision Prevention in Proton Therapy

Purpose: In proton therapy, collisions between patient and nozzle potentially occur in attaining minimal air gap due to the large nozzle structure. Thus, we developed software predicting the collisions of the nozzle and patient by simulating treatments. Methods: 3D modeling of a gantry inner-floor, nozzle and robotic-couch was done by using the SolidWorks based on the manufacturer’s machine data. To obtain patient body information, a 3D-scanner was utilized to scan a patient right before CT scanning. From the acquired images, a 3D-image of the patient’s body contour was reconstructed. The accuracy of the image was confirmed against the CT image for a humanoid phantom. The machine components and the virtual patient were combined on the treatment-room coordinate system, resulting in a virtual simulator. The simulator simulated the motion of its components such as rotation and translation of gantry, nozzle and couch, in real scale. Collision, if any, was examined both in static mode and dynamic mode. The static mode checks only at fixed positions of the machine’s components while dynamic mode examines while one component is in motion. Collision was notified if any voxel of two components, for example a nozzle and a patient or couch, overlapped when calculating volume locations. The event and collision point are visualized and colliding volumes are reported. Results: All components were successfully assembled and the motions could be accurately controlled. The 3D-shape of a phantom agreed with CT images within a deviation of 2 mm. Collision situations can be simulated within minutes and the results are displayed and reported. Conclusion: The developed software will be useful in improving patient safety and clinical efficiency for proton therapy. This work was supported by the National Research Foundation of Korea funded by Ministry of Science, ICT & Future Planning (2012M3A9B6055201, 2013M2A2A7043507), and Samsung Medical Center grant (GFO1130081)

60 APPLIED LIFE SCIENCES↗

SU-F-BRA-12: End-User Oriented Tools and Procedures for Testing Brachytherapy TPSs Employing MBDCAs

Purpose: To develop user-oriented tools for commissioning and dosimetry testing of {sup 192}Ir brachytherapy treatment planning systems (TPSs) employing model based dose calculation algorithms (MBDCAs). Methods: A software tool (BrachyGuide) has been developed for the automatic generation of MCNP6 input files from any CT based plan exported in DICOM RT format from Elekta and Varian TPSs. BrachyGuide also facilitates the evaluation of imported Monte Carlo (MC) and TPS dose distributions in terms of % dose differences and gamma index (CT overlaid colormaps or relative frequency plots) as well as DVHs and related indices. For users not equipped to perform MC, a set of computational models was prepared in DICOM format, accompanied by treatment plans and corresponding MCNP6 generated reference data. BrachyGuide can then be used to compare institutional and reference data as per TG186. The model set includes a water sphere with the MBDCA WG {sup 192}Ir source placed centrically and in two eccentric positions, a water sphere with cubic bone and lung inhomogeneities and a five source dwells plan, and a patient equivalent model with an Accelerated Partial Breast Irradiation (APBI) plan. Results: The tools developed were used for the dosimetry testing of the Acuros and ACE MBDCAs implemented in BrachyVision v.13 and Oncentra Brachy v.4.5, respectively. Findings were consistent with previous results in the literature. Besides points close to the source dwells, Acuros was found to agree within type A uncertainties with the reference MC results. Differences greater than MC type A uncertainty were observed for ACE at distances >5cm from the source dwells and in bone. Conclusion: The tools developed are efficient for brachytherapy MBDCA planning commissioning and testing. Since they are appropriate for distribution over the web, they will be put at the AAPM WG MBDCA’s disposal. Research co-financed by the ESF and Greek funds. NSRF operational Program: Education and Lifelong Learning Investing in Knowledge Society-Aristeia. Varian Medical Systems and Nucletron, an Elekta company provided access to TPSs for research purposes. Miss Peppa was supported by IKY-fellowships of excellence for postgraduate studies in Greece,Siemens Program.

60 APPLIED LIFE SCIENCES↗

The Autonomic Symptom Profile: a new instrument to assess autonomic symptoms

OBJECTIVE: To develop a new specific instrument called the Autonomic Symptom Profile to measure autonomic symptoms and test its validity. BACKGROUND: Measuring symptoms is important in the evaluation of quality of life outcomes. There is no validated, self-completed questionnaire on the symptoms of patients with autonomic disorders. METHODS: The questionnaire is 169 items concerning different aspects of autonomic symptoms. The Composite Autonomic Symptom Scale (COMPASS) with item-weighting was established; higher scores indicate more or worse symptoms. Autonomic function tests were performed to generate the Composite Autonomic Scoring Scale (CASS) and to quantify autonomic deficits. We compared the results of the COMPASS with the CASS derived from the Autonomic Reflex Screen to evaluate validity. RESULTS: The instrument was tested in 41 healthy controls (mean age 46.6 years), 33 patients with nonautonomic peripheral neuropathies (mean age 59.5 years), and 39 patients with autonomic failure (mean age 61.1 years). COMPASS scores correlated well with the CASS, demonstrating an acceptable level of content and criterion validity. The mean (+/-SD) overall COMPASS score was 9.8 (+/-9) in controls, 25.9 (+/-17.9) in the patients with nonautonomic peripheral neuropathies, and 52.3 (+/-24.2) in the autonomic failure group. Scores of symptoms of orthostatic intolerance and secretomotor dysfunction best predicted the CASS on multiple stepwise regression analysis. CONCLUSIONS: We describe a questionnaire that measures autonomic symptoms and present evidence for its validity. The instrument shows promise in assessing autonomic symptoms in clinical trials and epidemiologic studies.

NASA Discipline Cardiopulmonary↗

Calibration of the Gamma Knife using a new phantom following the AAPM TG51 and TG21 protocols

Purpose: To compare calibration of the Leksell Gamma Knife according to the American Association of Physicists in Medicine Task Groups 21 and 51 protocols. A new phantom was fabricated for this purpose. Its design, physical properties, and composition are described. Materials and methods: The Gamma Knife TG-51 calibration phantom is designed to be filled with water and support an ionization chamber positioned at its center. The phantom is thimble-shaped, with a 2 mm plastic wall to contain water. The phantom and chamber assembly was mounted in a LeksellTM stereotactic frame. The location of the chamber's sensitive volume was determined using computed tomography. The chamber-phantom assembly was attached to the 18 mm helmet in the Gamma Knife by the stereotactic frame. The phantom's geometry allowed radiation beams from each of the 201 Gamma Knife cobalt-60 sources to converge after an 8 cm path to the ionization chamber's sensitive volume. This is similar to the arrangement by which one calibrates the Gamma Knife using the manufacturer-supplied polystyrene phantom. Results: The phantom was attached to the Gamma Knife so that the ionization chamber was reproducibly positioned at the convergence of the radiation beams. Because of the phantom's design, the phantom could be affixed to either trunnions or the automatic patient positioning system, once mounted in the LeksellTM stereotectic frame. Comparisons using different phantoms and protocols resulted in the following calibration ratios for TG-21 in the polystyrene sphere phantom, TG-21 in the water phantom, and TG-51 in the water phantom, respectively: 1.000, 1.008, 0.986, when corrected for transmission through the plastic water reservoir wall and using the same ionization chamber. Transmission measurements using a 1 cm thickness of the same material in the Co-60 beam determined that the phantom's 2 mm plastic wall resulted in a reduction in the measured the output by 0.5%. Conclusions: Calibration of the Gamma Knife can be performed in liquid water using the AAPM TG-51 protocol and this new phantom, thereby eliminating uncertainties with respect to the composition of the manufacturer's phantom. Perturbation of calibration measurements by nonwater materials was characterized and could be corrected. Calibration values for the Gamma Knife that were obtained using the three methods for our phantoms agree to within 1.4%. TG21 and TG51 calibration of the Gamma Knife using the water phantom agreed to within 2.2%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The autonomic laboratory

The autonomic nervous system can now be studied quantitatively, noninvasively, and reproducibly in a clinical autonomic laboratory. The approach at the Mayo Clinic is to study the postganglionic sympathetic nerve fibers of peripheral nerve (using the quantitative sudomotor axon reflex test [QSART]), the parasympathetic nerves to the heart (cardiovagal tests), and the regulation of blood pressure by the baroreflexes (adrenergic tests). Patient preparation is extremely important, since the state of the patient influences the results of autonomic function tests. The autonomic technologist in this evolving field needs to have a solid core of knowledge of autonomic physiology and autonomic function tests, followed by training in the performance of these tests in a standardized fashion. The range and utilization of tests of autonomic function will likely continue to evolve.

NASA Discipline Cardiopulmonary↗

SU-F-T-91: Development of Real Time Abdominal Compression Force (ACF) Monitoring System

Purpose: Hard-plate based abdominal compression is known to be effective, but no explicit method exists to quantify abdominal compression force (ACF) and maintain the proper ACF through the whole procedure. In addition, even with compression, it is necessary to do 4D CT to manage residual motion but, 4D CT is often not possible due to reduced surrogating sensitivity. In this study, we developed and evaluated a system that both monitors ACF in real time and provides surrogating signal even under compression. The system can also provide visual-biofeedback. Methods: The system developed consists of a compression plate, an ACF monitoring unit and a visual-biofeedback device. The ACF monitoring unit contains a thin air balloon in the size of compression plate and a gas pressure sensor. The unit is attached to the bottom of the plate thus, placed between the plate and the patient when compression is applied, and detects compression pressure. For reliability test, 3 volunteers were directed to take several different breathing patterns and the ACF variation was compared with the respiratory flow and external respiratory signal to assure that the system provides corresponding behavior. In addition, guiding waveform were generated based on free breathing, and then applied for evaluating the effectiveness of visual-biofeedback. Results: We could monitor ACF variation in real time and confirmed that the data was correlated with both respiratory flow data and external respiratory signal. Even under abdominal compression, in addition, it was possible to make the subjects successfully follow the guide patterns using the visual biofeedback system. Conclusion: The developed real time ACF monitoring system was found to be functional as intended and consistent. With the capability of both providing real time surrogating signal under compression and enabling visual-biofeedback, it is considered that the system would improve the quality of respiratory motion management in radiation therapy. This research was supported by the Mid-career Researcher Program through NRF funded by the Ministry of Science, ICT & Future Planning of Korea (NRF-2014R1A2A1A10050270) and by the Radiation Technology R&D program through the National Research Foundation of Korea funded by the Ministry of Science, ICT & Future Planning (No. 2013M2A2A7038291)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-DE-207B-11: Implementation of Size-Specific 3D Beam Modulation Filters On a Dedicated Breast CT Platform Using Breast Immobilization

Purpose: To implement a 3D beam modulation filter (3D-BMF) in dedicated breast CT (bCT) and develop a method for conforming the patient’s breast to a pre-defined shape, optimizing the effects of the filter. This work expands on previous work reporting the methodology for designing a 3D-BMF that can spare unnecessary dose and improve signal equalization at the detector by preferentially filtering the beam in the thinner anterior and peripheral breast regions. Methods: Effective diameter profiles were measured for 219 segmented bCT images, grouped into volume quintiles, and averaged within each group to represent the range of breast sizes found clinically. These profiles were then used to generate five size-specific computational phantoms and fabricate five size-specific UHMW phantoms. Each computational phantom was utilized for designing a size-specific 3D-BMF using previously reported methods. Glandular dose values and projection images were simulated in MCNP6 with and without the 3DBMF using the system specifications of our prototype bCT scanner “Doheny”. Lastly, thermoplastic was molded around each of the five phantom sizes and used to produce a series of breast immobilizers for use in conforming the patient’s breast during bCT acquisition. Results: After incorporating the 3D-BMF, MC simulations estimated an 80% average reduction in the detector dynamic range requirements across all phantom sizes. The glandular dose was reduced on average 57% after normalizing by the number of quanta reaching the detector under the thickest region of the breast. Conclusion: A series of bCT-derived breast phantoms were used to design size-specific 3D-BMFs and breast immobilizers that can be used on the bCT platform to conform the patient’s breast and therefore optimally exploit the benefits of the 3D-BMF. Current efforts are focused on fabricating several prototype 3D-BMFs and performing phantom scans on Doheny for MC simulation validation and image quality analysis. Research reported in this paper was supported in part by the National Cancer Institute of the National Institutes of Health under award R01CA181081. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institue of Health.

60 APPLIED LIFE SCIENCES↗

Maternal susceptibility to nausea and vomiting of pregnancy: is the vestibular system involved?

Nausea and vomiting of pregnancy shares many characteristics with motion sickness, a vestibular dependent phenomenon. A number of physiologic changes that occur in normal pregnancy are also known to accompany nausea and vomiting in patients with motion sickness and certain vestibular disorders. This chapter summarizes some shared features of both phenomena. The unmasking of subclinical vestibular disorders may account for some cases of hyperemesis gravidarum. Hormonal effects on neurotransmitter function may also play a role in nausea and vomiting of pregnancy and in some vestibular disorders; however, the specific neural mechanisms of nausea and vomiting have not been identified. Until the neurochemical processes underlying these phenomena are understood, prevention and management will remain in the domain of astute, but so far limited, clinical observation.

NASA Discipline Neuroscience↗