Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Deviation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Evaluation of Magnetic Diagnostics for MHD Equilibrium Reconstruction of LHD Discharges

Equilibrium reconstruction is the process of determining the set of parameters of an MHD equilibrium that minimize the difference between expected and experimentally observed signals. This is routinely performed in axisymmetric devices, such as tokamaks, and the reconstructed equilibrium solution is then the basis for analysis of stability and transport properties. The V3FIT code [1] has been developed to perform equilibrium reconstruction in cases where axisymmetry cannot be assumed, such as in stellarators. The present work is focused on using V3FIT to analyze plasmas in the Large Helical Device (LHD) [2], a superconducting, heliotron type device with over 25 MW of heating power that is capable of achieving both high-beta ({approx}5%) and high density (>1 x 10{sup 21}/m{sup 3}). This high performance as well as the ability to drive tens of kiloamperes of toroidal plasma current leads to deviations in the equilibrium state from the vacuum flux surfaces. This initial study examines the effectiveness of using magnetic diagnostics as the observed signals in reconstructing experimental plasma parameters for LHD discharges. V3FIT uses the VMEC [3] 3D equilibrium solver to calculate an initial equilibrium solution with closed, nested flux surfaces based on user specified plasma parameters. This equilibrium solution is then used to calculate the expected signals for specified diagnostics. The differences between these expected signal values and the observed values provides a starting {chi}{sup 2} value. V3FIT then varies all of the fit parameters independently, calculating a new equilibrium and corresponding {chi}{sup 2} for each variation. A quasi-Newton algorithm [1] is used to find the path in parameter space that leads to a minimum in {chi}{sup 2}. Effective diagnostic signals must vary in a predictable manner with the variations of the plasma parameters and this signal variation must be of sufficient amplitude to be resolved from the signal noise. Signal effectiveness can be defined for a specific signal and specific reconstruction parameter as the dimensionless fractional reduction in the posterior parameter variance with respect to the signal variance. Here, {sigma}{sub i}{sup sig} is the variance of the ith signal and {sigma}{sub j}{sup param} param is the posterior variance of the jth fit parameter. The sum of all signal effectiveness values for a given reconstruction parameter is normalized to one. This quantity will be used to determine signal effectiveness for various reconstruction cases. The next section will examine the variation of the expected signals with changes in plasma pressure and the following section will show results for reconstructing model plasmas using these signals.

30 DIRECT ENERGY CONVERSION↗

Efficiency limits for photoelectrochemical water-splitting

Theoretical limiting efficiencies have a critical role in determining technological viability and expectations for device prototypes, as evidenced by the photovoltaics community’s focus on detailed balance. However, due to their multicomponent nature, photoelectrochemical devices do not have an equivalent analogue to detailed balance, and reported theoretical efficiency limits vary depending on the assumptions made. Here we introduce a unified framework for photoelectrochemical device performance through which all previous limiting efficiencies can be understood and contextualized. Ideal and experimentally realistic limiting efficiencies are presented, and then generalized using five representative parameters—semiconductor absorption fraction, external radiative efficiency, series resistance, shunt resistance and catalytic exchange current density—to account for imperfect light absorption, charge transport and catalysis. Finally, we discuss the origin of deviations between the limits discussed herein and reported water-splitting efficiencies. This analysis provides insight into the primary factors that determine device performance and a powerful handle to improve device efficiency.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

About the deformation of ferroelectric hystereses

Studying ferroelectric hafnium oxide with focus on memory applications for the past years, discussions frequently involved the shape of measured polarization hystereses, its relation to the device performance, and how to optimize it. A perfect model-like hysteresis is of nearly rectangular shape and all deviations from this situation have to have a certain physical origin. Different phenomena and their impact on the shape of the polarization hystereses were reported in literature: Aging, imprint, fatigue, or dielectric interface layers to name a few examples. A collection of these phenomena is not easily found up to now. Thus, filling or at least reducing this gap is one of the goals of this work. Moreover, observing a pinched, slanted, or displaced hysteresis, it is quite tempting to try the reverse approach: a derivation of potential structural origins for this curve shape. First, the basics of the dynamic hysteresis measurement and the ferroelectric memories are briefly reviewed. The figures of interest are derived to ensure a proper assessment of imperfections in the hysteresis shape and their influence. It is discussed how a closer look on the polarization loop helps to draw conclusions on what might have caused such a shape or at least how to rule out some phenomena if the expected indications are not reflected in the present curve. Of course, further structural or electrical studies, as they are exemplarily pointed out, are indispensable to find the root cause(s) for the deviations from the ideal hysteresis. But sophisticated methods are not always accessible straightaway and, moreover, a pointer on where to start is always helpful. Especially, the transient currents recorded during a dynamic hysteresis measurement are stressed as a valuable instrument for this purpose. Despite their known potential, these currents are seldom shown in literature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spatiotemporal filtering of MR-temperature artifacts arising from bowel motion during transurethral MR-HIFU

Purpose: Transurethral MR-HIFU is a minimally invasive image-guided treatment for localized prostate cancer that enables precise targeting of tissue within the gland. The treatment is performed within a clinical MRI to obtain real-time MR thermometry used as an active feedback to control the spatial heating pattern in the prostate and to monitor for potential damage to surrounding tissues. This requires that the MR thermometry measurements are an accurate representation of the true tissue temperature. The proton resonance frequency shift thermometry method used is sensitive to tissue motion and changes in the local magnetic susceptibility that can be caused by the motion of air bubbles in the rectum, which can impact the performance of transurethral MR-HIFU in these regions of the gland. Methods: A method is proposed for filtering of temperature artifacts based on the temporal variance of the temperature, using empirical and dynamic positional knowledge of the ultrasonic heating beam, and an estimation of the measurement noise. A two-step correction strategy is introduced which eliminates artifact-detected temperature variations while keeping the noise level low through spatial averaging. Results: The filter has been evaluated by postprocessing data from five human transurethral ultrasound treatments. The two-step correction process led to reduced final temperature standard deviation in the prostate and rectum areas where the artifact was located, without negatively affecting areas distal to the artifact. The performance of the filter was also found to be consistent across all six of the data sets evaluated. The evaluation of the detection criterion parameter M determined that a value of M = 3 achieves a conservative filter with minimal loss of spatial resolution during the process. Conclusions: The filter was able to remove most artifacts due to the presence of moving air bubbles in the rectum during transurethral MR-HIFU. A quantitative estimation of the filter capabilities shows a systematic improvement in the standard deviation of the corrected temperature maps in the rectum zone as well as in the entire acquired slice.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laboratory evaluation of open source and commercial electrical conductivity sensor precision and accuracy: How do they compare?

Variation in the electrical conductivity (EC) of water can reveal environmental disturbance and natural dynamics, including factors such as anthropogenic salinization. Broader application of open source (OS) EC sensors could provide an inexpensive method to measure water quality. While studies show that other water quality parameters can be robustly measured with sensors, a similar effort is needed to evaluate the performance of OS EC sensors. To address this need, we evaluated the accuracy (mean error, %) and precision (sample standard deviation) of OS EC sensors in the laboratory via comparison to EC calibration standards using three different OS and OS/commercial-hybrid (OS/C) EC sensors and data logger configurations and two commercial (C) EC sensors and data logger configurations. We also evaluated the effect of cable length (7.5 m and 30 m) and sensor calibration on OS sensor accuracy and precision. We found a significant difference between OS sensor mean accuracy (3.08%) and all other sensors combined (9.23%). Our study also found that EC sensor precision decreased across all sensor configurations with increasing calibration standard EC. There was also a significant difference between OS sensor mean precision (2.85 μS/cm) and the mean precision of all other sensors combined (9.12 μS/cm). Cable length did not affect OS sensor precision. Furthermore, our results suggest that future research should include evaluating how performance is impacted by combining OS sensors with commercial data loggers as this study found significantly decreased performance in OS/commercial-hybrid sensor configurations. To increase confidence in the reliability of OS sensor data, more studies such as ours are needed to further quantify OS sensor performance in terms of accuracy and precision across different settings and OS sensor and data collection platform configurations.

54 ENVIRONMENTAL SCIENCES↗

Quantifying Grain Level Stress-Strain Behavior for AM40 via Instrumented Microindentation

ABSTRACT Microindentation is performed on hot isostatic pressed (HIP) Mg-Al (AM40) alloy samples produced by high-pressure die cast (HPDC) process for the purpose of quantifying the mechanical properties of the α-Mg grains. The process of obtaining elastic modulus and hardness from indentation load-depth curves is well established in the literature. A new inverse method is developed to extract plastic properties in this study. The method utilizes empirical yield strength-hardness relationship reported in the literature together with finite element modeling of the individual indentation. Due to the shallow depth of the indentation, indentation size effect (ISE) is taken into account when determining plastic properties. The stress versus strain behavior is determined for a series of indents. The resulting average values and standard deviations are obtained for future use as input distributions for microstructure-based property prediction of AM40.

AM40↗

System and method for controlling a vision guided robot assembly

A method includes the following steps: actuating a robotic arm to perform an action at a start position; moving the robotic arm from the start position toward a first position; determining from a vision process method if a first part from the first position will be ready to be subjected to a first action by the robotic arm once the robotic arm reaches the first position; commencing the execution of the visual processing method for determining the position deviation of the second part from the second position and the readiness of the second part to be subjected to a second action by the robotic arm once the robotic arm reaches the second position; and performing a first action on the first part using the robotic arm with the position deviation of the first part from the first position predetermined by the vision process method.

42 ENGINEERING↗

Lumen Maintenance and Light Loss Factors: Consequences of Current Design Practices for LED's

Synopsis: Light loss factors are used to help lighting systems meet quantitative design criteria throughout the life of the installation, but they also influence energy use. As the light sources currently being specified continue to evolve, it is necessary to reevaluate the methods used in calculating light loss factors, as well as carefully consider the consequences of different product performance attributes. Because of the unique operating characteristics of LEDs and lack of a comprehensive lifetime rating—as well as the problematic relationship between lifetime and lumen maintenance—determining an appropriate lamp lumen depreciation (LLD) factor for LED products is difficult. As a result, a unique solution has been advocated: when quantity of light is an important design consideration, the IES recommends using an LLD of not greater than 0.70. This method deviates from the typical practice for conventional sources of using the ratio of mean to initial lumen output, and can misrepresent actual performance, increase energy use, and inhibit comparisons between products. This paper discusses the complications related to LLD and LEDs, compares the performance of conventional and LED products, and examines alternatives to a maximum LLD of 0.70 for LEDs.

Energy Efficiency↗

Deep-Learning-Based Koopman Modeling for Online Control Synthesis of Nonlinear Power System Transient Dynamics

Power system stability and control have become more challenging due to the increasing uncertainty associated with renewable generation. Here, the performance of conventional control is highly driven by the physics-based offline-developed dynamic models that can deviate from the actual system characteristics under different operating conditions and/or configurations. Data-driven approaches based on online measurements can be a better solution to addressing these issues by capturing real-time operation conditions. This article describes a novel fully data-driven probabilistic framework to derive a linear representation of postcontingency grid dynamics and online prescribe control based on the derived model to enhance transient stability. The complex nonlinear power system dynamics is approximated by a linear model by using multiple neural network modules that infer distributions of the observations and introducing a Koopman layer to sample possible Koopman linear models from the inferred distributions. The trained model features linearity that can be easily incorporated into the existing linear control design paradigm and ease the controller design process. The effectiveness of Koopman-based control designs is validated through comparative case studies, which demonstrate increased prediction accuracy and control performance when applied to a power system with heterogeneous generator dynamics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Project Dinos I: A joint lensing–dynamics constraint on the deviation from the power law in the mass profile of massive ellipticals

The mass distribution in massive elliptical galaxies encodes their evolutionary history, thus providing an avenue to constrain the baryonic astrophysics in their evolution. The power-law assumption for the radial mass profile in ellipticals has been sufficient to describe several observables to the noise level, including strong lensing and stellar dynamics. In this paper, we quantitatively constrained any deviation, or the lack thereof, from the power-law mass profile in massive ellipticals through joint lensing–dynamics analysis of a large statistical sample with 77 galaxy–galaxy lens systems. We performed an improved and uniform lens modelling of these systems from archival Hubble Space Telescope imaging using the automated lens modelling pipeline dolphin. We combined the lens model posteriors with the stellar dynamics to constrain the deviation from the power law after accounting for the line-of-sight lensing effects, a first for analyses on galaxy–galaxy lenses. We find that the Sloan Lens ACS Survey lens galaxies with a mean redshift of 0.2 are consistent with the power-law profile within 1.1σ (2.8σ) and the Strong Lensing Legacy Survey lens galaxies with a mean redshift of 0.6 are consistent within 0.8σ (2.1σ), for a spatially constant (Osipkov–Merritt) stellar anisotropy profile. We adopted the spatially constant anisotropy profile as our baseline choice based on previous dynamical observables of local ellipticals. However, spatially resolved stellar kinematics of lens galaxies are necessary to differentiate between the two anisotropy models. Future studies will use our lens models to constrain the mass distribution individually in the dark matter and baryonic components.

79 ASTRONOMY AND ASTROPHYSICS↗

Modular Hydronic Room Conditioning System (CRADA NFE-24-10120 Final Report)

This project presents the development and validation of high-fidelity numerical models for fin-tube heat exchangers to enable accurate performance prediction and informed design optimization. The modeling framework integrates detailed geometric specifications, thermophysical property data, and system-level constraints to simulate the heat exchanger’s behavior under a range of operating conditions. The model is calibrated using real-world product specifications and validated against experimental data collected from controlled cooling and heating tests. In cooling mode, the model captures the overall trends in capacity and outlet air temperature but tends to underpredict latent effects, especially at lower air flow rates. In heating mode, the simulation consistently overestimates both the thermal capacity and outlet air temperature, indicating the need for refinement in air-side heat transfer assumptions. Despite these deviations, the model provides a solid foundation for optimization, allowing key design variables to be tuned within physical and performance-based constraints. This research advances the ability to simulate, validate, and optimize fin-tube heat exchanger designs with greater confidence and efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modular Hydronic Room Conditioning System

This project presents the development and validation of high-fidelity numerical models for fin-tube heat exchangers to enable accurate performance prediction and informed design optimization. The modeling framework integrates detailed geometric specifications, thermophysical property data, and system-level constraints to simulate the heat exchanger’s behavior under a range of operating conditions. The model is calibrated using real-world product specifications and validated against experimental data collected from controlled cooling and heating tests. In cooling mode, the model captures the overall trends in capacity and outlet air temperature but tends to underpredict latent effects, especially at lower air flow rates. In heating mode, the simulation consistently overestimates both the thermal capacity and outlet air temperature, indicating the need for refinement in air-side heat transfer assumptions. Despite these deviations, the model provides a solid foundation for optimization, allowing key design variables to be tuned within physical and performance-based constraints. This research advances the ability to simulate, validate, and optimize fin tube heat exchanger designs with greater confidence and efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Irreversible Electroporation of Renal Cell Carcinoma: A First-in-Man Phase I Clinical Study

Purpose: Irreversible electroporation (IRE) is a newly developed nonthermal tissue-ablation technique in which high-voltage electrical pulses of microsecond duration are applied to induce irreversible permeabilisation of the cell membrane, presumably through nanoscale defects in the lipid bilayer, leading to apoptosis. The purpose of this study was to assess the feasibility and safety of ablating renal cell carcinoma (RCC) tissue by IRE. Methods: Six patients scheduled for curative resection of RCC were included. IRE was performed during anaesthesia immediately before the resection with electrographic synchronisation. Central haemodynamics were recorded before and 5 min after electroporation. Five-channel electrocardiography (ECG) was used for detailed analysis of ST waveforms. Blood sampling and 12-lead ECG were performed before, during, and at scheduled intervals after the intervention. Results: Analysis of ST waveforms and axis deviations showed no relevant changes during the entire study period. No changes in central haemodynamics were seen 5 min after IRE. Similarly, haematological, serum biochemical, and ECG variables showed no relevant differences during the investigation period. No changes in cardiac function after IRE therapy were found. One case of supraventricular extrasystole was encountered. Initial histopathologic examination showed no immediate adverse effects of IRE (observation of delayed effects will require a different study design). Conclusion: IRE seems to offer a feasible and safe technique by which to treat patients with kidney tumours and could offer some potential advantages over current thermal ablative techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Learning Topological Operations on Meshes with Application to Block Decomposition of Polygons

We present a learning based framework for mesh quality improvement on unstructured triangular and quadrilateral meshes. Our model learns to improve mesh quality according to a prescribed objective function purely via self-play reinforcement learning with no prior heuristics. The actions performed on the mesh are standard local and global element operations. The goal is to minimize the deviation of the node degrees from their ideal values, which in the case of interior vertices leads to a minimization of irregular nodes.

97 MATHEMATICS AND COMPUTING↗

Frameless Angiogram-Based Stereotactic Radiosurgery for Treatment of Arteriovenous Malformations

Purpose: Stereotactic radiosurgery (SRS) is an effective alternative to microsurgical resection or embolization for definitive treatment of arteriovenous malformations (AVMs). Digital subtraction angiography (DSA) is the gold standard for pretreatment diagnosis and characterization of vascular anatomy, but requires rigid frame (skull) immobilization when used in combination with SRS. With the advent of advanced proton and image-guided photon delivery systems, SRS treatment is increasingly migrating to frameless platforms, which are incompatible with frame-based DSA. Without DSA as the primary image, target definition may be less than optimal, in some cases precluding the ability to treat with a frameless system. This article reports a novel solution. Methods and Materials: Fiducial markers are implanted into the patient's skull before angiography. Angiography is performed according to the standard clinical protocol, but, in contrast to the previous practice, without the rigid frame. Separate images of a specially designed localizer box are subsequently obtained. A target volume projected on DSA can be transferred to the localizer system in three dimensions, and in turn be transferred to multiple CT slices using the implanted fiducials. Combined with other imaging modalities, this 'virtual frame' approach yields a highly precise treatment plan that can be delivered by frameless SRS technologies. Results: Phantom measurements for point and volume targets have been performed. The overall uncertainty of placing a point target to CT is 0.4 mm. For volume targets, deviation of the transformed contour from the target CT image is within 0.6 mm. The algorithm and software are robust. The method has been applied clinically, with reliable results. Conclusions: A novel and reproducible method for frameless SRS of AVMs has been developed that enables the use of DSA without the requirement for rigid immobilization. Multiple pairs of DSA can be used for better conformality. Further improvement, including using nonimplanted fiducials, is potentially feasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Resolution Measurement of Soil Thermal Properties and Moisture Content Using a Novel Heated Fiber Optics Approach

Hydrological parameters are scale dependent. Efficient monitoring techniques capable of measuring hydrological parameters, such as soil moisture content (θ), over a wide range of spatial scales are essential for understanding the complexity of water and energy movement across the landscape. Techniques to measure θ over spatial scales in the range from centimeters to thousands of meters, however, are sorely lacking. Recent improvements in the distributed temperature sensing (DTS) technology supported the development of novel techniques to fill that gap. However, improvements in the accuracy and applicability of DTS techniques are still needed. This study investigates the possibility of improving the accuracy of the fiber optics dual-probe heat-pulse (FO-DPHP) DTS technique by using a new design to maintain the spacing between the FO-DPHP probes and by introducing a novel data interpretation approach. The accuracy of the novel FO-DPHP design was tested at different θ in a sand column experiment. The FO-DPHP measurements obtained using traditional and novel data interpretation approaches were compared against independent measurements from several calibrated soil water content (EC5) sensors. Monte-Carlo analyses were also performed to assess the impact of DTS measurement errors on the accuracy achieved using the data interpretation approaches. The novel design and data interpretation approach allowed for accurate measurements of soil thermal properties and θ without the need to perform a hard-to-achieve soil-specific calibration. Measured θ had mean errors and standard deviations <0.03 and <0.01 m 3 m -3 , respectively, for moisture conditions ranging from dry to near saturation. The standard deviation in the measured heat capacity was <0.01 MJ m -3 K -1 .

42 ENGINEERING↗

The Q{sub weak}{sup p} Experiment A Test for Physics Beyond the Standard Model via a Precision Measurement of the Proton Weak Charge

The Qweak collaboration is currently preparing a measurement of the proton's weak charge Q{sub w}{sup p} = (1-4 sin{sup 2} {theta}{sub w}) at the Thomas Jefferson National Accelerator Facility (TJNAF). The experiment has been designed to produce a 4.1% measurement of the weak charge, via a 2.5% measurement of the parity violating asymmetry in the number of elastically scattered 1 GeV electrons from protons, at forward angles. At the proposed precision, the experiment would produce a 0.3% measurement of the weak mixing angle at a momentum transfer of {approx_equal}0.16 GeV, making it the most precise stand alone measurement of the weak mixing angle at low momentum transfer. In combination with other parity measurements, Qweak will also provide a high precision determination of the weak charges of the up and down quarks. Our proposed measurement of Q{sub w}{sup 2} will be performed with significantly smaller statistical and systematic errors than existing low Q{sup 2} data. Any significant deviation from the Standard Model prediction at low momentum transfer (Q{sup 2}) would be a signal of new physics, whereas agreement would place new and significant constraints on possible Standard Model extensions. The experiment is currently being prepared for installation, beginning in late 2009, and data taking beginning in mid 2010.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multi-reference vibration correlation methods

State-specific vibration correlation methods beyond the vibrational multi-configuration self-consistent field (VMCSCF) approximation have been developed, which allow for the accurate calculation of state energies for systems suffering from strong anharmonic resonances. Both variational multi-reference configuration interaction approaches and an implementation of approximate 2nd order vibrational multi-reference perturbation theory are presented. The variational approach can be significantly accelerated by a configuration selection scheme, which leads to negligible deviations in the final results. Relaxation effects due to the partitioning of the correlation space and the performance of a VMCSCF modal basis in contrast to a standard modal basis obtained from vibrational self-consistent field theory have been investigated in detail. Benchmark calculations based on high-level potentials are provided for the propargyl cation and cis-diazene.

74 ATOMIC AND MOLECULAR PHYSICS↗