Search NASA⌕ Search

SEARCH · Search NASA

Results for “Periodic Heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Lewis number effect on the propagation of premixed flames in closed tubes

The evolution of a premixed flame under conditions of confinement is studied theoretically. The analysis is based on a hydrodynamic model in which the flame is treated as a surface of discontinuity. The flame structure is assumed to be quasi-steady with a high activation energy and a large heat release. Its resolution in the postignition period yields a coupled system of equations for the determination of the pressure and the burning rate. The analysis also resolves the thermal and flow fields on either side of the flame and determines the instantaneous location of the flame front together with the overall time required for the flame to reach the end of the tube. The results indicate that qualitatively distinct behaviors are possible for mixtures depending on whether their Lewis numbers Le are less or greater than one.

Mcgreevy, J. L.↗

Effects of the Mount Pinatubo eruption on the radiative and chemical processes in the troposphere and stratosphere

The Lawrence Livermore National Laboratory two-dimensional zonally-averaged chemical-radiative-transport model of the global atmosphere was used to study the effects of the 15 June 1991 eruption of the Mt. Pinatubo volcano on stratospheric processes. SAGE 2 time-dependent aerosol surface area density and optical extinction data were used as input into the model. By 22 December 1991, a maximum equatorial change of -1.8 percent in column ozone was derived from heterogeneous chemical processes that convert NO(x) into HNO3 on sulfuric acid aerosols. Radiative feedbacks from increased aerosol optical thickness independently changes column ozone by approximately -3.5 percent for the same period. This occurs from increasing the net heating of the lower stratosphere, which indirectly increases chemical reaction rates via their temperature dependence and from changes in actinic fluxes, which directly modify photodissociation rates. Including both heterogeneous and radiative effects changes column ozone by -5.5 percent. The model-derived change overestimates the decrease in column ozone relative to the TOMS instrument on the Nimbus 7 satellite. Maximum local ozone decreases of 12 percent were derived in the equatorial region, at 25 km. Model-derived column NO2 peaked (-14 percent) at 30 deg S in October 1991. The timing of the NO2 peak is consistent with observation, but the model underestimates the magnitude of the decrease. Local concentrations of NO(x) (NO + NO2), ClO(x) (Cl + ClO), and HO(x) (OH + HO2), in the lower stratosphere between 30 deg S and 30 deg N, were calculated to have changed by -40 percent, +100 to +160 percent, and +120 to +140 percent respectively.

Kinnison, Douglas E.↗

Improvements in Thermal Protection Sizing Capabilities for TCAT: Conceptual Design for Advanced Space Transportation Systems

The Thermal Calculation Analysis Tool (TCAT), originally developed for the Space Systems Design Lab at the Georgia Institute of Technology, is a conceptual design tool capable of integrating aeroheating analysis into conceptual reusable launch vehicle design. It provides Thermal Protection System (TPS) unit thicknesses and acreage percentages based on the geometry of the vehicle and a reference trajectory to be used in calculation of the total cost and weight of the vehicle design. TCAT has proven to be reasonably accurate at calculating the TPS unit weights for in-flight trajectories; however, it does not have the capability of sizing TPS materials above cryogenic fuel tanks for ground hold operations. During ground hold operations, the vehicle is held for a brief period (generally about two hours) during which heat transfer from the TPS materials to the cryogenic fuel occurs. If too much heat is extracted from the TPS material, the surface temperature may fall below the freezing point of water, thereby freezing any condensation that may be present at the surface of the TPS. Condensation or ice on the surface of the vehicle is potentially hazardous to the mission and can also damage the TPS. It is questionable whether or not the TPS thicknesses provided by the aeroheating analysis would be sufficiently thick to insulate the surface of the TPS from the heat transfer to the fuel. Therefore, a design tool has been developed that is capable of sizing TPS materials at these cryogenic fuel tank locations to augment TCAT's TPS sizing capabilities.

Olds, John R.↗

Performance of Water Recirculation Loop Maintentance Components for the Advanced Spacesuit Water Membrane Evaporator

Water loop maintenance components to maintain the water quality of the Advanced Spacesuit Water Membrane Evaporation (SWME) water recirculation loop have undergone a comparative performance evaluation with a second SWME water recirculation loop with no water quality maintenance. Results show the benefits of periodic water maintenance. The SWME is a heat rejection device under development at the NASA Johnson Space Center to perform thermal control for advanced spacesuits. One advantage to this technology is the potential for a significantly greater degree of tolerance to contamination when compared to the existing Sublimator technology. The driver for the evaluation of water recirculation maintenance components was to further enhance this advantage through the leveraging of fluid loop management lessonslearned from the International Space Station (ISS). A bed design that was developed for a UTAS military application, and considered for a potential ISS application with the Urine Processor Assembly, provided a low pressure drop means for water maintenance in a recirculation loop. The bed design is coupled with high capacity ion exchange resins, organic adsorbents, and a cyclic methodology developed for the Extravehicular Mobility Unit (EMU) Transport Water loop. The maintenance cycle included the use of a biocide delivery component developed for ISS to introduce a biocide in a microgravity-compatible manner for the Internal Active Thermal Control System (IATCS). The leveraging of these water maintenance technologies to the SWME recirculation loop is a unique demonstration of applying the valuable lessons learned on the ISS to the next generation of manned spaceflight Environmental Control and Life Support System (ECLSS) hardware.

Rector, Tony↗

Performance of Water Recirculation Loop Maintenance Components for the Advanced Spacesuit Water Membrane Evaporator

Water loop maintenance components to maintain the water quality of the Advanced Spacesuit Water Membrane Evaporation (SWME) water recirculation loop have undergone a comparative performance evaluation with a second SWME water recirculation loop with no water quality maintenance. Results show the benefits of periodic water maintenance. The SWME is a heat rejection device under development at the NASA Johnson Space Center to perform thermal control for advanced spacesuits. One advantage to this technology is the potential for a significantly greater degree of tolerance to contamination when compared to the existing Sublimator technology. The driver for the evaluation of water recirculation maintenance components was to further enhance this advantage through the leveraging of fluid loop management lessons learned from the International Space Station (ISS). A bed design that was developed for a UTAS military application, and considered for a potential ISS application with the Urine Processor Assembly, provided a low pressure drop means for water maintenance in a recirculation loop. The bed design is coupled with high capacity ion exchange resins, organic adsorbents, and a cyclic methodology developed for the Extravehicular Mobility Unit (EMU) Transport Water loop. The maintenance cycle included the use of a biocide delivery component developed for ISS to introduce a biocide in a microgravity compatible manner for the Internal Active Thermal Control System (IATCS). The leveraging of these water maintenance technologies to the SWME recirculation loop is a unique demonstration of applying the valuable lessons learned on the ISS to the next generation of manned spaceflight Environmental Control and Life Support System (ECLSS) hardware.

Rector, Tony↗

Solar energy system performance evaluation. Seasonal report for SEECO Lincoln, Lincoln, Nebraska

The Solar Engineering and Equipment Company (SEECO) Lincoln solar energy system, designed for space heating only, is described and its operational performance for a 12 month period from April 1979 through March 1980 is evaluated. The system met 27 percent of the space heating load; however, system losses into the heated space from the storage bin and ductwork were significant. Reducing these losses would add appreciably to the system's efficiency. Net fossil energy savings were 11.31 million BTUs.

Source record↗

STS-1 Nominal Cycle 3 March/April Launch, Ascent Base Convective Heating Environments

Ascent base convective heating environments were determined for the nominal ascent trajectory for the STS-1 Cycle 3 March/April launch period. Both first and second stage environments are defined for all base heating DFI locations and design body points of interest. An identical format to the STS-1 dispersed trajectory environment was followed throughout. As expected, STS-1 nominal environments are generally less severe than those determined for the high loft and low loft dispersed trajectory conditions. The reduction in cold wall heating with the nominal trajectory varies for each base location analyzed, but, in general, was approximately twenty percent.

Bender, R. L., Jr.↗

Observations Indicate That Clouds Amplify Mechanisms of Southern Ocean Heat Uptake

Abstract The Southern Ocean has absorbed most of the excess heat associated with anthropogenic greenhouse gas emissions. Since Southern Ocean observations are sparse in certain regions and seasons, much of our knowledge of ocean heat uptake is based on climate model simulations. However, climate models still inadequately represent some properties of Southern Ocean clouds, and they have not identified the mechanisms by which clouds may affect Southern Ocean heat uptake (SOHU). Here, we use the ERA5 and JRA‐55 reanalyses to assess the influence of clouds and other atmospheric processes on SOHU from 1979 to 2020. We find that years with the highest SOHU between 45° and 65°S are dominated by ocean heat uptake anomalies during winter and spring, but not during summer or fall. Winter and spring cloud cover are up to 7% higher when SOHU is up to 5.5 W/m 2 higher than the climatological seasonal mean, with the largest increases in the South Pacific Ocean. Clouds also contain more liquid water. These changes in cloud properties increase downwelling longwave radiation, amplifying ocean heat uptake. Cloud changes are also concomitant with a more stable lower atmosphere, which suppresses turbulent heat fluxes out of the surface. Overall, we find that SOHU is likely not mediated by enhanced surface shortwave absorption over the observational time period. A better understanding of how atmospheric processes impact ocean heat uptake may help improve our understanding of ocean heat uptake mechanisms in the current generation of climate models.

54 ENVIRONMENTAL SCIENCES↗

Thermal analysis of M552 experiment for materials processing in space

Analytical and experimental studies made of heat flow in the exothermic brazing unit in the M552 experiment are described. The emphasis of the studies was placed on heat flow in the tube and the sleeve during a period from ignition to the time when the brazing alloy solidifies. Experiments were made of three specimens tested in a ground-based laboratory. Heat flow was determined by thermocouples. The analytical study covered two phases: (1) the effect of reduced gravity on heat flow in the exothermic brazing unit; and (2) the development of analytical models. The major mode of heat transfer was conduction and the effect of gravity was minimal. Good agreements were obtained between experimental and analytical results indicating the soundness of the analytical models.

Muraki, T.↗

Explosive Boiling at Very Low Heat Fluxes: A Microgravity Phenomenon

The paper presents experimental observations of explosive boiling from a large (relative to bubble sizes) flat heating surface at very low heat fluxes in microgravity. The explosive boiling is characterized as either a rapid growth of vapor mass over the entire heating surface due to the flashing of superheated liquid or a violent boiling spread following the appearance of single bubbles on the heating surface. Pool boiling data with saturated Freon 113 was obtained in the microgravity environment of the space shuttle. The unique features of the experimental results are the sustainability of high liquid superheat for long periods and the occurrence of explosive boiling at low heat fluxes (0.2 to 1.2 kW/sq m). For a heat flux of 1.0 kW/sq m a wall superheat of 17.9 degrees C was attained in ten minutes of heating. This was followed by an explosive boiling accompanied with a pressure spike and a violent bulk liquid motion. However, at this heat flux the vapor blanketing the heating surface could not be sustained. Stable nucleate boiling continued following the explosive boiling.

Hasan, M. M.↗

A study of the evolution of the surface heat flux off the southeast coast of the United States during a cold air outbreak using satellite remote sensing data

Attention is given to the contribution of the marine boundary layer to storm development via a study of the evolution of the spatial distribution of the heat flux during a cold-air outburst (CAO) which occurred during the GALE Field Program period in a 550,000-sq-km area off the southeast coast of the United States. The study focuses on a CAO that occurred in the period February 24-26, 1986. During the CAO, the area averaged total surface heat flux ranged from 190 W/sq m to 1114 W/sq m. The high value was characterized by a lower average surface air and dew-point temperatures and a higher average surface wind speed. In general, the surface heat flux increased as the sea-surface temperatures on the continental shelf increased. It reached the maximum over the Gulf Stream, and then decreased over the eastern portions of the Gulf Stream and over the Sargasso Sea. The configuration conforms with some of the earlier findings of Bane and Osgoode (1989) and Blanton et al. (1989).

Vukovich, Fred M.↗

Heat Transport Hysteresis Generated Through Frequency Switching of a Time-Dependent Temperature Gradient

A stochastic energetics framework is applied to examine how periodically shifting the frequency of a time-dependent oscillating temperature gradient affects heat transport in a nanoscale molecular model. We specifically examine the effects that frequency switching, i.e., instantaneously changing the oscillation frequency of the temperature gradient, has on the shape of the heat transport hysteresis curves generated by a particle connected to two thermal baths, each with a temperature that is oscillating in time. Analytical expressions are derived for the energy fluxes in/out of the system and the baths, with excellent agreement observed between the analytical expressions and the results from nonequilibrium molecular dynamics simulations. We find that the shape of the heat transport hysteresis curves can be significantly altered by shifting the frequency between fast and slow oscillation regimes. We also observe the emergence of features in the hysteresis curves such as pinched loops and complex multi-loop patterns due to the frequency shifting. The presented results have implications in the design of thermal neuromorphic devices such as thermal memristors and thermal memcapacitors.

36 MATERIALS SCIENCE↗

An intercomparison of measured and modeled canopy parameters during the variable water-stressed period of FIFE 1989 using an hybrid biosphere-remote sensing model

The measured atmospheric parameters and the fluxes of latent and sensible heat across the biosphere-atmosphere interface collected during the water-stressed period of the First ISLSCP Field Experiment (FIFE) were compared with those calculated by an experimental version of the Biosphere-Atmosphere Transfer Scheme (Ex-BATS). It is shown that the brightness temperature (T(B)) values observed near the surface during FIFE 1987 are closely correlated to in-canopy temperatures calculated by Ex-BATS. The 1987 near-surface observations of T(B) are also well correlated to AVHHR channels 4 and 5 measurements. An inverted form of Ex-BATS was applied to determine the associated required in-canopy temperatures, T(icr), and regressions between T(icr) and T(B) found from the 1987 data were applied to the 1989 observed T(B) at a different site. The T(icr) so estimated showed excellent correlation to the 1989 model calculated T(icr).

Cooper, H. J.↗

Using Thin-Film Thermometers as Heaters in Thermal Control Applications

A cryogenic sensor maintains calibration at approximately equal to 4.2 K to better than 2 mK (< 0.5 percent resistance repeatability) after being heated to approximately equal 40 K with approximately equal 0.5 W power. The sensor withstands 4 W power dissipation when immersed in liquid nitrogen with verified resistance reproducibility of, at worst, 1 percent. The sensor maintains calibration to 0.1 percent after being heated with 1-W power at approximately equal 77 K for a period of 48 hours. When operated with a readout scheme that is capable of mitigating the self-heating calibration errors, this and similar sensors can be used for precision (mK stability) temperature control without the need of separate heaters and associated wiring/cabling.

Cho, Hyung J.↗

End-Use Savings Shapes Measure Documentation: Thermostat Control for Load Shifting in Large Offices

This documentation focuses on a single end-use savings shape measure - thermostat control for load shifting. The thermostat control for load shifting measure applies heating and cooling temperature setpoint adjustment for pre-conditioning before the peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start time of the peak window, and then adjusts the thermostat cooling or heating setpoints by a specified offset value from original schedules to precool or preheat the space , for a specified length of time before the start of peak window, and thus shifts load in the peak window to the pre-conditioning period. The measure is flexible and allows users to adjust the heating and cooling offset values and length of pre-conditioning period, but for this study, the load shifting strategy is applied as pre-cooling only (adjusting only cooling setpoints). The default adjustment for cooling setpoints is set to -1 degrees Celsius , and the default duration of pre-cooling is 1 hour. This measure is applicable to large offices equipped with electric HVAC system, which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shifting measure demonstrates -1% daily peak demand reduction and 0% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tidal Heating in Multilayered Terrestrial Exoplanets

The internal pattern and overall magnitude of tidal heating for spin-synchronous terrestrial exoplanets from 1 to 2.5 R(sub E) is investigated using a propagator matrix method for a variety of layer structures. Particular attention is paid to ice-silicate hybrid super-Earths, where a significant ice mantle is modeled to rest atop an iron-silicate core, and may or may not contain a liquid water ocean. We find multilayer modeling often increases tidal dissipation relative to a homogeneous model, across multiple orbital periods, due to the ability to include smaller volume low viscosity regions, and the added flexure allowed by liquid layers. Gradations in parameters with depth are explored, such as allowed by the Preliminary Earth Reference Model. For ice-silicate hybrid worlds, dramatically greater dissipation is possible beyond the case of a silicate mantle only, allowing non-negligible tidal activity to extend to greater orbital periods than previously predicted. Surface patterns of tidal heating are found to potentially be useful for distinguishing internal structure. The influence of ice mantle depth and water ocean size and position are shown for a range of forcing frequencies. Rates of orbital circularization are found to be 10-100 times faster than standard predictions for Earth-analog planets when interiors are moderately warmer than the modern Earth, as well as for a diverse range of ice-silicate hybrid super-Earths. Circularization rates are shown to be significantly longer for planets with layers equivalent to an ocean-free modern Earth, as well as for planets with high fractions of either ice or silicate melting.

celestial mechanics↗

Long-term trends in connected thermostat performance

Internet-connected thermostats (CTs) control heating and cooling systems in about 30% of North American homes, and capture half of annual thermostat sales. In 2017 the U.S. Environmental Protection Agency created a program to certify the performance of ENERGY STAR® Connected Thermostats. To demonstrate compliance with energy-saving criteria, thermostat vendors must submit performance summaries for a representative sample of up to 1250 homes. Vendors must then re-submit results from a new, representative sample every six months in order to maintain their ENERGY STAR certification. This procedure has created a unique record of each thermostat’s long-term performance in response to changes in weather, customer demographics, building stock, and algorithms. Our analysis covers submissions from 13 different vendors, who submitted data up to 7 times over four years. We found that these semi-annual samples generated relatively stable trends for comfort temperatures and Heating, Ventilating and Air Conditioning (HVAC) runtimes over the study period. However, some vendors achieved consistently more energy-conserving comfort temperatures and shorter HVAC runtimes than others. The most recent submission runtimes averaged 700 hours for heating and 1,300 hours for cooling, but some vendors achieved runtimes as much as 17% below the mean. This implies lower energy consumption is due in large part to more successful algorithms and control strategies used by those vendors.

Meier, Alan↗

Vertical Profiles of Latent Heat Release and Their Retrieval for TOGA COARE Convective Systems Using a Cloud Resolving Model, SSM/I, and Ship-borne Radar Data

Latent heating profiles associated with three (TOGA COARE) Tropical Ocean and Global Atmosphere Coupled Ocean Atmosphere Response Experiment active convective episodes (December 10-17 1992; December 19-27 1992; and February 9-13 1993) are examined using the Goddard Cumulus Ensemble (GCE) Model and retrieved by using the Goddard Convective and Stratiform Heating (CSH) algorithm . The following sources of rainfall information are input into the CSH algorithm: Special Sensor Microwave Imager (SSM/1), Radar and the GCE model. Diagnostically determined latent heating profiles calculated using 6 hourly soundings are used for validation. The GCE model simulated rainfall and latent heating profiles are in excellent agreement with those estimated by soundings. In addition, the typical convective and stratiform heating structures (or shapes) are well captured by the GCE model. Radar measured rainfall is smaller than that both estimated by the GCE model and SSM/I in all three different COARE IFA periods. SSM/I derived rainfall is more than the GCE model simulated for the December 19-27 and February 9-13 periods, but is in excellent agreement with the GCE model for the December 10-17 period. The GCE model estimated stratiform amount is about 50% for December 19-27, 42% for December 11-17 and 56% for the February 9-13 case. These results are consistent with large-scale analyses. The accurate estimates of stratiform amount is needed for good latent heating retrieval. A higher (lower) percentage of stratiform rain can imply a maximum heating rate at a higher (lower) altitude. The GCE model always simulates more stratiform rain (10 to 20%) than the radar for all three convective episodes. SSM/I derived stratiform amount is about 37% for December 19-27, 48% for December 11-17 and 41% for the February 9-13 case. Temporal variability of CSH algorithm retrieved latent heating profiles using either GCE model simulated or radar estimated rainfall and stratiform amount is in good agreement with that diagnostically determined for all three periods. However, less rainfall and a smaller stratiform percentage estimated by radar resulted in a weaker (underestimated) latent heating profile and a lower maximum latent heating level compared to those determined diagnostically. Rainfall information from SSM/I can not retrieve individual convective events due to poor temporal sampling. Nevertheless, this study suggests that a good 4r, rainfall retrieval from SSM/I for a convective event always leads to a good latent heating retrieval. Sensitivity testing has been performed and the results indicate that the SSM/I derived time averaged stratiform amount may be underestimated for December 19-27. Time averaged heating profiles derived from SSM/I, however, are not in bad agreement with those derived by soundings for the December 10-17 convective period. The heating retrievals may be more accurate for longer time scales provided there is no bias in the sampling.

Tao, Wei-Kuo↗