ALTERNATIVE AND ENHANCED CHEMICAL CLEANING: CORROSION STUDIES RESULTS: FY2010

Due to the need to close High Level Waste storage tanks, chemical cleaning methods are needed for the removal of sludge heel materials remaining at the completion of mechanical tank cleaning efforts. Oxalic acid is considered the preferred cleaning reagent for heel dissolution of iron-based sludge. However, the large quantity of chemical reagents added to the tank farm from oxalic acid based cleaning has significant downstream impacts. Optimization of the oxalic acid cleaning process can potentially reduce the downstream impacts from chemical cleaning. To optimize oxalic acid usage, a detailed understanding of the chemistry of oxalic acid based sludge dissolution is required. Additionally, other acidic systems may be required for specific waste components that have low solubility in oxalic acid, and as a means to reduce oxalic acid usage in general. Electrochemical corrosion studies were conducted with 1 wt. % oxalic acid at mineral acid concentrations above and below the optimal conditions for this oxalic acid concentration. Testing environments included pure reagents, pure iron and aluminum phases, and sludge simulants. Mineral acid concentrations greater than 0.2 M and temperatures greater than 50 C result in unacceptably high corrosion rates. Results showed that manageable corrosion rates of carbon steel can be achieved at dilute mineral acid concentrations (i.e. less than 0.2 M) and low temperatures based on the contact times involved. Therefore, it is recommended that future dissolution and corrosion testing be performed with a dilute mineral acid and a less concentrated oxalic acid (e.g., 0.5 wt.%) that still promotes optimal dissolution. This recommendation requires the processing of greater water volumes than those for the baseline process during heel dissolution, but allows for minimization of oxalic acid additions. The following conclusions can be drawn from the test results: (1) In both nitric and sulfuric acid based reagents, the low temperature and dilute concentration environment resulted in carbon steel corrosion rates that were less than 150 mpy. These rates are manageable in that chemical cleaning processes could proceed for limited time without significant wall loss. Further optimization of the Alternative Enhance Chemical Cleaning (AECC) process should focus on testing in solutions of this dilute concentration and low temperature regime. (2) In general, for the nitric acid based reagent, the aluminum oxide phase environments resulted in higher corrosion rates than the iron oxide phase environments. (3) In general, for the sulfuric acid based reagent, the iron oxide phase environments resulted in higher corrosion rates than the aluminum oxide phase environments. (4) In general, for the nitric acid based reagent, the HM sludge simulant environments resulted in higher corrosion rates than the PUREX sludge simulant environments. This result agrees with the previous observation that the aluminum oxide phases are more aggressive than the iron oxide phase environments in the nitric acid reagent. (5) Pitting was more likely to occur in the sulfuric acid based reagents than in the nitric acid based reagents. (6) Pitting occurred only in the iron based pure oxide phases and the sludge simulants. No pitting was observed in the aluminum based pure oxide phases. (7) Pitting tended to occur more frequently in tests that involved the dilute mineral acid reagent. (8) Pitting was more severe at the higher temperature for a given mineral acid concentration. (9) Pitting was more severe at a higher mineral acid concentration for a given temperature. (10) Based on the combined results of the open circuit potential and cathodic polarization testing, there was a low propensity for hydrogen evolution in solutions where sludge has been dissolved.

08 HYDROGEN↗

Corrosion study of bare and coated stainless steel

A program was conducted at Kennedy Space Center from February 1968 to February 1971 to evaluate the performance of austenitic stainless steel alloys used in fluid systems lines. For several years, there had been numerous failures of stainless steel hardware caused by pitting and stress corrosion cracking. Several alloys were evaluated for effectiveness of certain sacrificial-type protective coverings in preventing corrosion failures. Samples were tested in specially designed racks placed 91 meters (100 yards) above high-tide line at Cape Kennedy. It is concluded that: (1) unprotected tubing samples showed evidence of pitting initiation after 2 weeks; (2) although some alloys develop larger pits than others, it is probable that the actual pitting rate is independent of alloy type; (3) the deepest pitting occurred in the sheltered part of the samples; and (4) zinc-rich coatings and an aluminum-filled coating have afforded sacrificial protection against pitting for at least 28 months. It is believed that a much longer effective coating life can be expected.

Morrison, J. D.↗

Microcrater investigations on lunar rock 12002

Relative ages of 26 submillimeter-sized pits from an equilibrium population in rock 12002 were measured by determining the densities of pits 0.7 microns in diameter and larger on the submillimeter-sized pits. Production rates for 0.7 micron diameter pits were determined from solar-flare track exposure age measurements, and the data for rock 12002 are consistent with previously obtained data for sample 15205 if a lower meteoroid flux prevailed in the past. Metal mounds or spherules within a microcrater pit glass were found to have a meteoritic composition, and an impact lining consisting of protruding crystals was observed. The crystals apparently developed during exposure to space immediately after the 200-micron diameter pit was formed by impact into an olivine grain.

Hartung, J. B.↗

Weathering of basaltic rocks under cold, arid conditions - Antarctica and Mars

The processes taking part in the chemical weathering of nonvesicular dolerite cobbles producing etch pits and secondary minerals including clays, under cold arid conditions of high-altitude ice-free areas of Victoria Land (Antarctica) are investigated as a possible analog to processes that produced the pitted rocks and clay minerals on Mars. Results suggest that the pits in the dolerite cobbles are formed by the dissolution of the rock by rare snow-melt water during the austral summer, followed by wind erosion of weathered material. The upper interior walls of the pits are lined with a yellow precipitate consisting of illite and quartz mixture, while the pit bottoms contain alteration products including Fe-rich clay minerals and soluble salts. A model is proposed for rock pitting on Mars analogous to that of the Antarctic dolerites.

Allen, C. C.↗

Possible occurrence and origin of massive ice in Utopia Planitia

F. M. Costard recently discovered a large field of possible thermokarst depressions near latitude 45 deg N, longitude 270 deg, in western Utopia Planitia. Oval to circular pits are typically 300-1000 m across and approximately 25 m deep; larger depressions, 3-5 km across, are compound and seem to have formed by coalescence of smaller pits. Small domical hills occur on the floors of two pits. These depressions characteristically have steep, scalloped edges and one or more inner benches. Truncation relations of the benches suggest a discontinuous, lenslike stratification of the material in which the pits are developed. Based on a close analogy in form and scale with coalesced thawlake basins (alases) on Earth, the Martian pits may have formed by thermophysical interactions of pooled water with ice-rich permafrost. This interpretation is not unique; sublimation of ice-rich permafrost or possibly even eolian processes acting on ice-free material might have formed the pits. However, the regional setting contains many other indications of massive ice. Some of these features are examined.

Kargel, J. S.↗

Gear Damage Detection Using Oil Debris Analysis

The purpose of this paper was to verify, when using an oil debris sensor, that accumulated mass predicts gear pitting damage and to identify a method to set threshold limits for damaged gears. Oil debris data was collected from 8 experiments with no damage and 8 with pitting damage in the NASA Glenn Spur Gear Fatigue Rig. Oil debris feature analysis was performed on this data. Video images of damage progression were also collected from 6 of the experiments with pitting damage. During each test, data from an oil debris sensor was monitored and recorded for the occurrence of pitting damage. The data measured from the oil debris sensor during experiments with damage and with no damage was used to identify membership functions to build a simple fuzzy logic model. Using fuzzy logic techniques and the oil debris data, threshold limits were defined that discriminate between stages of pitting wear. Results indicate accumulated mass combined with fuzzy logic analysis techniques is a good predictor of pitting damage on spur gears.

Dempsey, Paula J.↗

Exploration of Planetary Skylights and Tunnels

While planetary pits and caves have been fiction for a century, they have been seen from orbit only in the last few years. These discoveries exceed the fantasies in diversity, scale, and abundance. For pits and caves, this is the age of discovery, ranging from a few pits on the Moon and Mars in 2009 to hundreds within the time of this research, with many more to come. Pits with subsurface voids have been confirmed on the Moon and Mars and indicated on Venus, Phobos, Eros, Gaspra, Ida, Enceladus, and Europa. Compelling next steps are surface and subsurface exploration.Pits and caves are opportunistic study targets for unique origins, geology, and climate that will broadly impact planetary science. Holes on Mars are of particular interest because their interior caves are relatively protected from the harsh surface, making them good candidates to contain Martian life. Pits are prime targets for possible future spacecraft, robots, and even human interplanetary explorers. Caves and caverns could be ready-_made shelters for future Moon and Mars explorers and colonists. Discoveries to date look down from on high with satellites but cannot reveal the wonders of caves. They cannot enter, touch, or view pits up close. Genuine exploration is only achievable through surface missions. Robotic missions can assess suitability for safe entry and habitation, plus inform techniques for developing subsurface infrastructure.Missions into planetary voids redefine the future of exploration, science, and habitation beyond Earth. We can reach this future only by targeting specific technological advancement now. Prior missions and current roadmap priorities target regions of benign terrain. While in-cave concepts have been postulated, the critical technologies have not been identified and demonstrated.While robotic exploration of skylights and caves can seek out life, investigate geology and origins, and open the subsurface of other worlds to humankind, it is a daunting venture. Planetary voids present perilous terrain requiring innovative technologies for access, exploration, and modeling. These same technologies are broadly applicable to explorations of rough and/or subsurface planetary environments, including caves, craters, cliffs, and rock fields. This research speculates on the possibilities and means of such exploration with fundamental contributions to exploring, modeling, and visualizing this new class of large-scale, highly three-dimensional concave planetary features.

Whittaker, Red↗

Surface Topography of 'Hotspot' Regions from a Single Cell SRF Cavity

Performance of SRF cavities are limited by non-linear localized effects. The variation of local material characters between "hot" and "cold" spots is thus of intense interest. Such locations were identified in a BCP-etched large-grain single-cell cavity and removed for examination by high resolution electron microscopy (SEM), electron-back scattering diffraction microscopy (EBSD), optical microscopy, and 3D profilometry. Pits with clearly discernable crystal facets were observed in both "hotspot" and "coldspot" specimens. The pits were found in-grain, at bi-crystal boundaries, and on tri-crystal junctions. They are interpreted as etch pits induced by surface crystal defects (e.g. dislocations). All "coldspots" examined had qualitatively low density of etching pits or very shallow tri-crystal boundary junction. EBSD revealed the crystal structure surrounding the pits via crystal phase orientation mapping, while 3D profilometry gave information on the depth and size of the pits. In addition, a survey of the samples by energy dispersive X-ray analysis (EDX) did not show any significant contamination of the samples surface.

36 MATERIALS SCIENCE↗

Appurtenance Influence on Type III Hanford Single-Shell Tank Structural Integrity

The interim stabilized Hanford Single Shell Tanks (SSTs) are currently undergoing a state of the art analysis to assess the structural integrity of the waste storage tanks, for cleanup and closure operations, considering their adverse thermal histories and an updated seismic hazard for the Hanford Site near Richland, Washington. The SSTs contain a variety of ancillary pits, piping, piping supports, risers, equipment, and penetrations known as appurtenances. These appurtenances may alter the structural response and ultimately could affect the structural integrity of the SSTs. An important challenge to the structural analysis of the SSTs is determining the impact of these appurtenances on structural integrity. To achieve this, the various appurtenances were reviewed and bounding appurtenance configurations for SST Types II and III tank designs were analyzed using finite element software. The bounding configurations for the Type II tanks considered four heavy offset pits with a central pit with and without a 36-inch diameter central post-construction penetration and four 42-inch diameter offset penetrations. The bounding configuration for the Type III tanks is a tank with two heavy offset pits and one heavy central pit. For each bounding configuration two finite element models are developed: a seismic analysis model and a thermal and operating loads analysis (TOLA) model. The TOLA models include a Type II or III thermal history, concrete cracking and thermal degradation, reinforcement yielding, and soil plasticity. Additionally, operating loads such as internal waste pressure and concentrated and distributed soil surface loads are applied to the TOLA model. The seismic model treats the tank concrete as linear elastic based on the present day degraded concrete properties. Also, in the seismic model the soil is treated as linear elastic while special techniques are used in the soil above the tank dome and along the tank wall to avoid soil arching and achieve the proper soil pressure on the tank walls. Seismic time histories (in the horizontal and vertical directions) are applied to the seismic model. The American Concrete Institute (ACI) has code requirements for nuclear safety-related concrete structures (ACI-349-06) that are used to evaluate the structural integrity of the SSTs. ACI-349-06 recommends evaluating factored load combinations against reduced tank section capacities to account for both loading and material uncertainties. From both the TOLA and seismic models the structural demands (forces and moments) are extracted from sections throughout the tank under the appropriate load combinations. These demands are compared against the ACI-349-06 capacities at each of the sections. This ratio of demand to capacity is reported as a measure of structural integrity. The Type II and Type III appurtenances configurations are found to increase the demand to capacity ratios in local regions near the appurtenances. Away from the appurtenances the influence on structural integrity is minor. A comparison of the Type II and III results show that even though the Type II offset pits weight less, they have a larger impact on the structural integrity of the tanks due to their locations. Finally, lessons learned from the Type II and Type III appurtenance analysis, and their application to the more complex Type IV structural integrity analysis, will be discussed.

appurtenances↗

In-service inspection of radioactive waste tanks at the Savannah River Site - 15410

Liquid radioactive wastes from the Savannah River Site (SRS) separation process are stored in large underground carbon steel tanks. The high level wastes are processed in several of the tanks and then transferred by piping to other site facilities for further processing before they are stabilized in a vitrified or grout waste form. Based on waste removal and processing schedules, many of the tanks, will be required to be in service for times exceeding the initial intended life. Until the waste is removed from storage, transferred, and processed, the materials and structures of the tanks must maintain a confinement function by providing a barrier to the environment and by maintaining acceptable structural stability during design basis events, which include loadings from both normal service and abnormal (e.g., earthquake) conditions. A structural integrity program is in place to maintain the structural and leak integrity functions of these waste tanks throughout their intended service life. In-service inspection (ISI) is an essential element of a comprehensive structural integrity program for the waste tanks at the Savannah River Site (SRS). The ISI program was developed to determine the degree of degradation the waste tanks have experienced due to service conditions. As a result of the inspections, an assessment can be made of the effectiveness of corrosion controls for the waste chemistry, which precludes accelerated localized and general corrosion of the waste tanks. Ultrasonic inspections (UT) are performed to detect and quantify the degree of general wall thinning, pitting and cracking as a measure of tank degradation. The results from these inspections through 2013, for the 27 Type III/IIIA tanks, indicate no reportable in-service corrosion degradation in the primary tank (i.e., general, pitting, or cracking). The average wall thickness for all tanks remains above the manufactured nominal thickness minus 0.25 millimeter and the largest pit identified is approximately 1.70 millimeter deep (i.e., less than 10% through-wall). Improvements to the inspection program were recently instituted to provide additional confidence in the degradation rates. Thickness measurements from a single vertical strip along the accessible height of the primary tank have been used as a baseline to compare historical measurements. Changes in wall thickness and pit depths along this vertical strip are utilized to estimate the rate of corrosion degradation. An independent review of the ISI program methodology, results, and path forward was held in August 2009. The review recommended statistical sampling of the tanks to improve the confidence of the single strip inspection program. The statistical sampling plan required that SRS increase the amount of area scanned per tank. Therefore, in addition to the baseline vertical strip that is obtained for historical comparisons, four additional randomly selected vertical strips are inspected. To date, a total of 104 independent vertical strips along the height of the primary tank have been completed. A statistical analysis of the data indicates that at this coverage level there is a 99.5% confidence level that one of the worst 5% of all the vertical strips was inspected. That is, there is a relatively high likelihood that the SRS inspection program has covered one of the most corroded areas of any of the Type III/IIIA waste tanks. These data further support the conclusion that there are no significant indications of wall thinning or pitting. Random sampling will continue to increase the confidence that one of the worst 5% has been inspected. In order to obtain the additional vertical strips, and minimize budget and schedule impacts, data collection speed for the UT system was optimized. Prior to 2009, the system collected data at a rate of 32 square centimeters per minute. The scan rate was increased to 129 - 160 square centimeters per minute by increasing the scanner step and pixel sizes in the data acquisition set-up. Laboratory testing was utilized to optimize the scan index/pixel size such that the requirements for wall thinning and pit detection were still maintained. SRS continues to evaluate improvements to ultrasonic equipment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Study on the corrosion residual strength of the 1.0 wt.% Ce modified AZ91 magnesium alloy

The effect of corrosion on the tensile behaviour of the 1.0 wt.% Ce modified AZ91 magnesium alloy was investigated by the immersion of the test bar in 3.5 wt.% NaCl aqueous solution for 0, 12, 40, 108, 204, 372 and 468 h with the subsequent tensile tests in this paper. The fractography was analyzed by scanning electron microscopy. The results show that pitting corrosion should be responsible for the drop of the corrosion residual strength within the testing time. The depth of the corrosion pits was statistically and quantitatively obtained by an optical microscopy and the maximal value was recorded as the extreme depth of the corrosion pit. Furthermore, the corrosion residual strength is linearly dependent on the extreme depth of the corrosion pit, which can be attributed to the loss of cross-sectional area and the emergence of stress concentration caused by the initiation and development of corrosion pits.

36 MATERIALS SCIENCE↗

CORROSION TESTING IN SIMULATED TANK SOLUTIONS

Three simulated waste solutions representing wastes from tanks SY-102 (high nitrate, modified to exceed guidance limits), AN-107, and AY-102 were supplied by PNNL. Out of the three solutions tested, both optical and electrochemical results show that carbon steel samples corroded much faster in SY-102 (high nitrate) than in the other two solutions with lower ratios of nitrate to nitrite. The effect of the surface preparation was not as strong as the effect of solution chemistry. In areas with pristine mill-scale surface, no corrosion occurred even in the SY-102 (high nitrate) solution, however, corrosion occurred in the areas where the mill-scale was damaged or flaked off due to machining. Localized corrosion in the form of pitting in the vapor space of tank walls is an ongoing challenge to overcome in maintaining the structural integrity of the liquid waste tanks at the Savannah River and Hanford Sites. It has been shown that the liquid waste condensate chemistry influences the amount of corrosion that occurs along the walls of the storage tanks. To minimize pitting corrosion, an effort is underway to gain an understanding of the pitting response in various simulated waste solutions. Electrochemical testing has been used as an accelerated tool in the investigation of pitting corrosion. While significant effort has been undertaken to evaluate the pitting susceptibility of carbon steel in various simulated waste solutions, additional effort is needed to evaluate the effect of liquid waste supernates from six Hanford Site tanks (AY-101, AY-102, AN-102, AN-107, SY-102 (high Cl{sup -}), and SY-102 (high nitrate)) on carbon steel. Solutions were formulated at PNNL to replicate tank conditions, and in the case of SY-102, exceed Cl{sup -} and NO{sub 3}{sup -} conditions, respectively, to provide a contrast between in and out of specification limits. The majority of previous testing has been performed on pristine polished samples. To evaluate the actual tank carbon steel surface, efforts are needed to compare the polished surfaces to corroded and mill-scale surfaces, which are more likely to occur in application. Additionally, due to the change in liquid waste levels within the tanks, salt deposits are highly likely to be present along the tank wall. When the level of the tank decreases, a salt deposit will form as the solution evaporates. The effects of this pre-existing salt, or supernate deposit, are unknown at this time on the corrosion effect and thus require investigation. Additionally, in the presence of radiation, moist air undergoes radiolysis, forming a corrosive nitric acid condensate. This condensate could accelerate the corrosion process in the vapor space. To investigate this process, an experimental apparatus simulating the effects of radiation was designed and constructed to provide gamma irradiation while coupons are exposed to a simulate tank solution. Additionally, ammonia vapors will also be introduced to further represent the tank environment.

36 MATERIALS SCIENCE↗

Vapor Space Corrosion Testing Simulating The Environment Of Hanford Double Shell Tanks

As part of an integrated program to better understand corrosion in the high level waste tanks, Hanford has been investigating corrosion at the liquid/air interface (LAI) and at higher areas in the tank vapor space. This current research evaluated localized corrosion in the vapor space over Hanford double shell tank simulants to assess the impact of ammonia and new minimum nitrite concentration limits, which are part of the broader corrosion chemistry limits. The findings from this study showed that the presence of ammonia gas (550 ppm) in the vapor space is sufficient to reduce corrosion over the short-term (i.e. four months) for a Hanford waste chemistry (SY102 High Nitrate). These findings are in agreement with previous studies at both Hanford and SRS which showed ammonia gas in the vapor space to be inhibitive. The presence of ammonia in electrochemical test solution, however, was insufficient to inhibit against pitting corrosion. The effect of the ammonia appears to be a function of the waste chemistry and may have more significant effects in waste with low nitrite concentrations. Since high levels of ammonia were found beneficial in previous studies, additional testing is recommended to assess the necessary minimum concentration for protection of carbon steel. The new minimum R value of 0.15 was found to be insufficient to prevent pitting corrosion in the vapor space. The pitting that occurred, however, did not progress over the four-month test. Pits appeared to stop growing, which would indicate that pitting might not progress through wall.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

WRPS Hanford Update [Slides]

The purpose of this report is to coordinate with the staff from WRPS, the current contract holder for operations at the Hanford site to better inform design decisions for the Autonomous systems for Hanford waste tank handling project. The project goals are to support risk reduction associated with monitoring, inspection and mapping of Hanford tank underground pits and includes: 1. A pit mock-up demonstration of Idaho National Laboratory’s (INL) Autonomous Pit Exploration System (APES) technology, which has two configurations: A. The Autonomous Robotic Arm, which is a proposed collaboration with Florida International University (FIU) and has capabilities to visually inspect, monitor, map and conduct simple tool manipulation tasks in the tank pits, and B. The robotic crawler configuration, which has capabilities to deploy to the bottom of the pits and conduct closer and bottom-up visual inspections. 2. An Implementation Plan that identifies Hanford site-wide application of the INL remote robotics technologies to enhance the performance of the tank farm systems and the characterization of the waste they contain to mitigate risk and optimize the overall waste mission. 3. A first-of-a-kind environmental digital twin will be produced. Digital twins to date require permanently installed sensors in order to produce asset specific predictions. This project will use the intermittent signals during inspections from deployed sensors on robotic systems to produce the data sets used by AI/ML to enable predictions of issues on tanks.

42 - ENGINEERING↗

Aging Hanford Nuclear Waste Using Carbon Dioxide to Evaluate Corrosion at Lower pH Limits - 18467

Samples of Hanford Nuclear Reservation (HNR) tank waste and simulated Hanford tank waste were exposed to carbon dioxide gas (CO{sub 2}) in the laboratory in order to decrease the pH of the solution. Sodium hydroxide is required to be added to some tanks according to waste handling specifications to keep tanks protected from pitting corrosion, but the maximum-allowed volume in some tanks is currently approaching capacity. Decreasing the pH of tank solutions using CO{sub 2} gas mimics the environmental exposure chemistry, does not add sodium, and allows for testing on solutions currently categorized as out-of-specification according to technical waste handling documents. Legacy alloy A537 Class 1 carbon steel was used to construct the AN tanks on the HNR and was utilized for this testing. The planned testing of three solutions included a simulant for feasibility and a waste solution from Tank 241-AN-102 (AN-102), taken in 2013, which was run in duplicate. The solutions were evaluated for corrosion potential using cyclic potentiodynamic polarization (CPP) scans to determine the propensity for stress corrosion cracking and pitting corrosion. Results in all solutions showed that pitting potential was low when the pH was above 11 and temperatures were below 40 deg. C. As solution pHs dipped into the 10- 10.5 range, there were mixed results. CPP scans were initially run at the higher temperature of 50 deg. C, accelerating corrosion rates. Solution pHs that did not indicate corrosion were further exposed to CO{sub 2}. Solutions with mixed or positive pitting results were rerun at 40 deg. C. The first failed run on the tank solution was seen when testing the duplicate sample at 50 deg. C and a pH of 13.01. When this solution was retested at 40 deg. C, the CPP scan did not show corrosion. A mixed corrosion result was obtained from a scan run at the final pH of 10 when tested at 50 deg. C. Upon completion of testing a visual inspection of the coupon did not show corrosion products on its surface. These results provide assurance that tanks containing slightly reduced pHs are still protected from pitting corrosion. Tank integrity assurance at a lower pH limit in Tank AN-102 could slow sodium addition and the rising volume of hazardous waste. Other benefits of reducing the pH specification would be reduced costs associated with retrieving and storing smaller volumes of hazardous waste, a reduced number of radiation exposure events (required for pH modification of tank waste), and a potential for a decreased volume required to be immobilized for long-term storage in a vitrified (glass) phase. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Chloride-Induced Stress Corrosion Cracking Characteristics of the Used Nuclear Fuel Canister Material

The used nuclear fuel (UNF) dry storage systems are located in the coastal and lake/river-side regions, the service time of which is 60 years and more. One type of dry storage systems is composite of a thin-walled austenitic stainless steel (SS) welded canister and a concrete overpack. The air flows through the canister surface and brings away the decay heat. Meanwhile, the air brings the salt species into the canister and make them deposit on the surface. The salt deposit will be deliquescent when absorbing the moisture air, being corrosive to the surface. NRC and other programs claimed that chloride induced stress corrosion cracking (CISCC) would lead to the canister failure, being one of the major technical gaps for extended dry storage systems. CISCC is induced by the combined influence of the aggressive environment (chloride ions in our case) and tensile stresses (residual stresses in our case) on the susceptible materials (the austenitic SS in our case). Chrome (Cr), as one of the chemical compositions of SSs, plays an important role in the corrosion resistance. It can form a chrome-rich inner barrier oxide layer to prevent the SS from corrosion. However, chloride ions can easily break down the barrier and accelerate dissolution of the underlying metal, the phenomena of which is pitting corrosion. Pitting is the precursor to CISCC as which provides the combination of a local aggressive solution chemistry and a stress concentrating feature. Accordingly, CISCC invariably originates from the pits, and cracks that have nucleated on pit walls can grow around the pit and coalesce to form a complete through-crack. Significant tensile residual stresses, caused by the welding process, exist throughout the thickness of the canister wall. Enos and Bryan found that large residual stresses were in the full-scale mockup container simulating a canister, which supports the SCC propagation. It is therefore interesting to achieve a good knowledge about the effect of welding on the durability of SSs, especially in the corrosive environment. In order to understand the fundamental of the cracking behaviors, it's vital to elucidate the microstructure and microchemistry of cracking. This study focused on observing the CISCC characteristics of the UNF canister material exposed to the humid environment with salt deposit. Extensive micro-characteristics have been achieved by the techniques include focused ion beam/ scanning electron microscope (FIB/SEM), transmission electron microscopy (TEM), energy dispersive spectroscopy (EDS), and optical profiler. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MECHANISTIC UNDERSTANDING OF CAUSTIC CRACKING OF CARBON STEELS

Liquid waste generated by the PUREX process for separation of nuclear materials is concentrated and stored in Type IV single-shell carbon steel tanks at the Savannah River Site (SRS). The Type IV tanks for this waste do not have cooling coils and have not undergone heat treatment to stress-relieve the tanks. After the waste is concentrated by evaporation, it becomes very alkaline and can cause stress corrosion cracking (SCC) and pitting corrosion of the tank materials. SRS has experienced leakage from non-stress-relieved waste tanks constructed of A285 carbon steel and pitting of A212 carbon steel tanks in the vapor space. An investigation of tank materials has been undertaken at SRS to develop a basic understanding of caustic SCC of A285 and A212 grade carbon steels exposed to aqueous solutions, primarily containing sodium hydroxide (NaOH), sodium nitrate (NaNO{sub 3}), and sodium nitrite (NaNO{sub 2}) at temperatures relevant to the operating conditions of both the F and H area plants. This report presents the results of this corrosion testing program. Electrochemical tests were designed using unstressed coupons in a simulated tank environment. The purpose of this testing was to determine the corrosion susceptibility of the tank materials as a function of chemical concentration, pH, and temperature. A285 and A516 (simulates A212 carbon steel) coupons were used to investigate differences in the corrosion of these carbon steels. Electrochemical testing included measurement of the corrosion potential and polarization resistance as well as cyclic potentiodynamic polarization (CPP) testing of coupons. From the CPP experiments, corrosion characteristics were determined including: corrosion potential (E{sub corr}), pitting or breakdown potential (E{sub pit}), and repassivation potential (E{sub prot}). CPP results showed no indications of localized corrosion, such as pitting, and all samples showed the formation of a stable passive layer as evidenced by the positive hysteresis during the scan. Analysis of the CPP data was performed to compare the corrosion susceptibility of the samples under different environmental conditions. Test results indicated that the most important factors affecting corrosion of the steel are the solution temperature, hydroxide concentration, and the material used in constructing the tanks. Variables that did not significantly affect the corrosion susceptibility of the steel were the nitrate or nitrite concentration and the atmosphere in the tank. The passivation current of the coupons increased exponentially with temperature. Longer-term studies of the passivation current are suggested based on results from the literature for iron in highly caustic environments. Polarization resistance studies showed a significant increase in corrosion rate at 125 C and 12 M hydroxide concentration when compared with tests at lower temperatures and lower hydroxide concentrations. Within the temperature and pH range of these tests, iron oxide, Fe{sub 3}O{sub 4}, becomes unstable and could account for the increased corrosion susceptibility. The applicability of these conditions should be confirmed and detailed surface studies should be conducted to determine the corrosion resistance of A285 and A516 carbon steels under these conditions. Surface science studies should also be conducted to determine the role of the carbon steel composition in preventing corrosion under these conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Improving Abundance Estimates of Spring–Summer Snake River Chinook Salmon for Fisheries Management

Abstract The Columbia River basin is home to a run of spring–summer Chinook Salmon Oncorhynchus tshawytscha that returns to the Snake River drainage of Idaho, Oregon, and Washington in the Pacific Northwest. Historically, the run was one of the more productive throughout the Columbia River basin. However, Snake River spring–summer Chinook Salmon have experienced declines in abundance due to overfishing, habitat degradation, and dams. Several stocks are listed as threatened under the U.S. Endangered Species Act and are supported by mitigation hatcheries funded by Idaho Power Company, the Lower Snake River Compensation Plan, and the Bonneville Power Administration. To maximize tribal and state harvest of returning hatchery adults, minimize impacts on wild fish, and ensure that enough hatchery fish return to meet broodstock needs, careful fisheries management is required. Since 2008, managers have used hatchery adults, PIT-tagged as juveniles and detected at Lower Granite Dam, to generate adult abundance estimates. In season, these estimates inform state and tribal harvest shares and ensure that broodstock needs are met. Postseason, they provide smolt-to-adult survival and return rates. Since 2012, parentage-based tagging (PBT) has provided an alternative method to estimate stock- and age-specific returns at Lower Granite Dam, since returning hatchery adults sampled at Lower Granite Dam can be assigned to their parents. We compared stock-specific abundance estimates between PIT- and PBT-derived methodologies for return years 2016–2019. Across all years, PIT tag estimates accounted for 65% of the PBT-based estimates at Lower Granite Dam across all age-groups and release sites combined. This underrepresentation across all groups equated to 49,833 fish that were not accounted for in PIT tag abundance estimates. It is clear that PBT-based estimates should aide in-season harvest management and postseason run reconstruction to avoid the known bias of estimates from PIT tags, especially during years of low returns when increased accuracy is critical.