Distributed Antenna-Coupled TES for FIR Detectors Arrays

We describe a new architecture for a superconducting detector for the submillimeter and far-infrared. This detector uses a distributed hot-electron transition edge sensor (TES) to collect the power from a focal-plane-filling slot antenna array. The sensors lay directly across the slots of the antenna and match the antenna impedance of about 30 ohms. Each pixel contains many sensors that are wired in parallel as a single distributed TES, which results in a low impedance that readily matches to a multiplexed SQUID readout These detectors are inherently polarization sensitive, with very low cross-polarization response, but can also be configured to sum both polarizations. The dual-polarization design can have a bandwidth of 50The use of electron-phonon decoupling eliminates the need for micro-machining, making the focal plane much easier to fabricate than with absorber-coupled, mechanically isolated pixels. We discuss applications of these detectors and a hybridization scheme compatible with arrays of tens of thousands of pixels.

antenna↗

Modulation Transfer Function of Infrared Focal Plane Arrays

Modulation transfer function (MTF) is the ability of an imaging system to faithfully image a given object. The MTF of an imaging system quantifies the ability of the system to resolve or transfer spatial frequencies. In this presentation we will discuss the detail MTF measurements of 1024x1024 pixels mid -wavelength and long- wavelength quantum well infrared photodetector, and 320x256 pixels long- wavelength InAs/GaSb superlattice infrared focal plane arrays (FPAs). Long wavelength Complementary Barrier Infrared Detector (CBIRD) based on InAs/GaSb superlattice material is hybridized to recently designed and fabricated 320x256 pixel format ROIC. The n-type CBIRD was characterized in terms of performance and thermal stability. The experimentally measured NE delta T of the 8.8 micron cutoff n-CBIRD FPA was 18.6 mK with 300 K background and f/2 cold stop at 78K FPA operating temperature. The horizontal and vertical MTFs of this pixel fully delineated CBIRD FPA at Nyquist frequency are 49% and 52%, respectively.

long-wave infrared↗

TES-Based X-Ray Microcalorimeter Performances Under AC Bias and FDM for Athena

Athena is a European X-ray observatory, scheduled for launch in 2028. Athena will employ a high-resolution imaging spectrometer called X-ray integral field unit (X-IFU), consisting of an array of 4000 transition edge sensor (TES) microcalorimeter pixels. For the readout of X-IFU, we are developing frequency domain multiplexing, which is the baseline readout system. In this paper, we report on the performance of a TES X-ray calorimeter array fabricated at Goddard Space Flight Center (GSFC) at MHz frequencies for the baseline of X-IFU detector. During single-pixel AC bias characterization, we measured X-ray energy resolutions (at 6 keV) of about 2.9 eV at both 2.3 and 3.7 MHz. Furthermore, in the multiplexing mode, we measured X-ray energy resolutions of about 2.9 eV at 1.3 and 1.7 MHz.

Transition edge sensors X-ray microcalorimeter Fre↗

Reduced-Scale Transition-Edge Sensor Detectors for Solar and X-Ray Astrophysics

We have developed large-format, close-packed X-ray microcalorimeter arrays fabricated on solid substrates, designed to achieve high energy resolution with count rates up to a few hundred counts per second per pixel for X-ray photon energies upto 8 keV. Our most recent arrays feature 31-micron absorbers on a 35-micron pitch, reducing the size of pixels by about a factor of two. This change will enable an instrument with significantly higher angular resolution. In order to wire out large format arrays with an increased density of smaller pixels, we have reduced the lateral size of both the microstrip wiring and the Mo/Au transition-edge sensors (TES). We report on the key physical properties of these small TESs and the fine Nb leads attached, including the critical currents and weak-link properties associated with the longitudinal proximity effect.

Arrays↗

Gain calibrating nonuniform image-array data using only the image data

An algorithm is developed for calibrating the spatial nonuniformity of image-array (CCD-type) detectors. Like other techniques this approach uses multiple, spatially displaced images. In circumstances where high-precision flat fields are not available by other means (i.e., sky flats) this technique is advantageous as it uses the data frames for gain calibration even when the array images extended, nonuniform, sources. Numerical experiments and direct observations with intrinsically uniform and quite nonuniform detectors show that this algorithm is useful when data frames are crowded with sources - circumstance where 'median filtering' flatfielding techniques often fail. The algorithm described is robust and efficiently uses information from multiple data frames to determine pixel gain variations, using visible and IR array observations of extended sources.

Kuhn, J. R.↗

Toward Large Field-Of-View High-Resolution X-Ray Imaging Spectrometers: Microwave Multiplexed Readout of 28 TES Microcalorimeters

We performed small-scale demonstrations at GSFC of high-resolution Xray TES microcalorimeters read out using a microwave SQUID multiplexer. This work is part of our effort to develop detector and readout technologies for future space-based X-ray instruments such as the microcalorimeter spectrometer envisaged for Lynx, a large mission concept under development for the Astro 2020 Decadal Survey. In this paper we describe our experiment, including details of a recently designed, microwave-optimized low-temperature setup that is thermally anchored to the 55mKstage of our laboratory ADR. Using aROACH2 FPGA at room temperature, we read out pixels of a GSFC-built detector array via a NIST-built multiplexer chip with Nb coplanar waveguide resonators coupled to rf-SQUIDs. The resonators are spaced 6 MHz apart (at ∼ 5.9 GHz) and have quality factors of ∼ 15,000. In our initial demonstration, we used flux-ramp modulation frequencies of 125 kHz to read out 5 pixels simultaneously and achieved spectral resolutions of 2.8-3.1 eV FWHM at 5.9 keV. Our subsequent work is ongoing: to-date we have achieved a median spectral resolution of 3.4 eV FWHM at 5.9 keV while reading out 28 pixels simultaneously with flux-ramp frequencies of 160 kHz. We present the measured system-level noise and maximum slew rates and briefly describe our future development work.

Yoon, W.↗

Heat Sinking, Cross Talk, and Temperature Stability for Large, Close-Packed Arrays of Microcalorimeters

We are developing large, close-packed arrays of x-ray transition-edge sensor (TES) microcalorimeters. In such a device, sufficient heat sinking is important to to minimize thermal cross talk between pixels and to stabilize the bath temperature for all pixels. We have measured cross talk on out 8 x 8 arrays and studied the shape and amount of thermal crosstalk as a function of pixel location and efficiency of electrothermal feedback. In this presentation, we will compare measurements made on arrays with and without a backside, heat-sinking copper layer, as well as results of devices on silicon-nitride membranes and on solid substrates, and we will discuss the implications for energy resolution and maximum count rate. We will also discuss the dependence of pulse height upon bath temperature, and the measured and required stability of the bath temperature.

Imoto, Naoko↗

Toward Large FOV High-Resolution X-Ray Imaging Spectrometer: Microwave Multiplexed Readout of 32 TES Microcalorimeters

We performed a small-scale demonstration at GSFC of high-resolution x-ray TES microcalorimeters read out using a microwave SQUID multiplexer. This work is part of our effort to develop detector and readout technologies for future space based x-ray instruments such as the microcalorimeter spectrometer envisaged for Lynx, a large mission concept under development for the Astro 2020 Decadal Survey. In this paper we describe our experiment, including details of a recently designed, microwave-optimized low-temperature setup that is thermally anchored to the 50 mK stage of our laboratory ADR. Using a ROACH2 FPGA at room temperature, we simultaneously read out 32 pixels of a GSFC-built detector array via a NIST-built multiplexer chip with Nb coplanar waveguide resonators coupled to RF SQUIDs. The resonators are spaced 6 MHz apart (at approx. 5.9 GHz) and have quality factors of approximately 15,000. Using flux-ramp modulation frequencies of 160 kHz we have achieved spectral resolutions of 3 eV FWHM on each pixel at 6 keV. We will present the measured system-level noise and maximum slew rates, and briefly describe the implications for future detector and readout design.

Yoon, Wonsik↗

Mechanical Design and Development of TES Bolometer Detector Arrays for the Advanced ACTPol Experiment

The next generation Advanced ACTPol (AdvACT) experiment is currently underway and will consist of four Transition Edge Sensor (TES) bolometer arrays, with three operating together, totaling 5800 detectors on the sky. Building on experience gained with the ACTPol detector arrays, AdvACT will utilize various new technologies, including 150 mm detector wafers equipped with multichroic pixels, allowing for a more densely packed focal plane. Each set of detectors includes a feedhorn array of stacked silicon wafers which form a spline pro le leading to each pixel. This is then followed by a waveguide interface plate, detector wafer, back short cavity plate, and backshort cap. Each array is housed in a custom designed structure manufactured from high purity copper and then gold plated. In addition to the detector array assembly, the array package also encloses cryogenic readout electronics. We present the full mechanical design of the AdvACT high frequency (HF) detector array package along with a detailed look at the detector array stack assemblies. This experiment will also make use of extensive hardware and software previously developed for ACT, which will be modi ed to incorporate the new AdvACT instruments. Therefore, we discuss the integration of all AdvACT arrays with pre-existing ACTPol infrastructure.

Advanced ACTPol (AdvACT)↗

Short wavelength 128 by 128 focal plane arrays for remote sensing applications

Short-wavelength (1-2.5-micron) 128x128 focal plane arrays have been fabricated and demonstrated with high pixel yields and dark-current-limited performance. The detector material is HgCdTe grown by LPE on a sapphire substrate which yields high-performance uniform detectors. The detector arrays were characterized at temperatures of 80-150 K; the peak quantum efficiency at 2.4 microns is 80 percent. The multiplexer is a Reticon FET switch with output amplifiers. It is noted that the long-term goal of this project is to develop a 150x1000 mosaicked focal plane for use in the HIRIS instrument on the Earth Observing System.

Bothwell, Mary↗

A laboratory verification sensor

The use of a variant of the Hartmann test is described to sense the coalignment of the 36 primary mirror segments of the Keck 10-meter Telescope. The Shack-Hartmann alignment camera is a surface-tilt-error-sensing device, operable with high sensitivity over a wide range of tilt errors. An interferometer, on the other hand, is a surface-height-error-sensing device. In general, if the surface height error exceeds a few wavelengths of the incident illumination, an interferogram is difficult to interpret and loses utility. The Shack-Hartmann aligment camera is, therefore, likely to be attractive as a development tool for segmented mirror telescopes, particularly at early stages of development in which the surface quality of developmental segments may be too poor to justify interferometric testing. The constraints are examined which would define the first-order properties of a Shack-Hartmann alignment camera and the precision and range of measurement one could expect to achieve with it are investigated. Fundamental constraints do arise, however, from consideration of geometrical imaging, diffraction, and the density of sampling of images at the detector array. Geometrical imagining determines the linear size of the image, and depends on the primary mirror diameter and the f-number of a lenslet. Diffraction is another constraint; it depends on the lenslet aperture. Finally, the sampling density at the detector array is important since the number of pixels in the image determines how accurately the centroid of the image can be measured. When these factors are considered under realistic assumptions it is apparent that the first order design of a Shack-Hartmann alignment camera is completely determined by the first-order constraints considered, and that in the case of a 20-meter telescope with seeing-limited imaging, such a camera, used with a suitable detector array, will achieve useful precision.

Vaughan, Arthur H.↗

CdTe Focal Plane Detector for Hard X-Ray Focusing Optics

The demand for higher resolution x-ray optics (a few arcseconds or better) in the areas of astrophysics and solar science has, in turn, driven the development of complementary detectors. These detectors should have fine pixels, necessary to appropriately oversample the optics at a given focal length, and an energy response also matched to that of the optics. Rutherford Appleton Laboratory have developed a 3-side buttable, 20 millimeter x 20 millimeter CdTe-based detector with 250 micrometer square pixels (80 x 80 pixels) which achieves 1 kiloelectronvolt FWHM (Full-Width Half-Maximum) @ 60 kiloelectronvolts and gives full spectroscopy between 5 kiloelectronvolts and 200 kiloelectronvolts. An added advantage of these detectors is that they have a full-frame readout rate of 10 kilohertz. Working with NASA Goddard Space Flight Center and Marshall Space Flight Center, 4 of these 1 millimeter-thick CdTe detectors are tiled into a 2 x 2 array for use at the focal plane of a balloon-borne hard-x-ray telescope, and a similar configuration could be suitable for astrophysics and solar space-based missions. This effort encompasses the fabrication and testing of flight-suitable front-end electronics and calibration of the assembled detector arrays. We explain the operation of the pixelated ASIC readout and measurements, front-end electronics development, preliminary X-ray imaging and spectral performance, and plans for full calibration of the detector assemblies. Work done in conjunction with the NASA Centers is funded through the NASA Science Mission Directorate Astrophysics Research and Analysis Program.

X-ray↗

James Webb Space Telescope Near-Infrared Spectrograph: Dark Performance of the First Flight Candidate Detector Arrays

The James Webb Space Telescope (JWST) Near Infrared Spectrograph (NIRSpec) incorporates two 5 micron cutoff (lambda(sub co) = 5 micron) 2048x2048 pixel Teledyne HgCdTe HAWAII-2RG sensor chip assemblies. These detector arrays, and the two Teledyne SIDECAR application specific integrated circuits that control them, are operated in space at T approx. 37 K. This article focuses on the measured performance of the first flight-candidate, and near-flight candidate, detector arrays. These are the first flight-packaged detector arrays that meet NIRSpec's challenging 6 e(-) rms total noise requirement.

Rauscher, Bernard J.↗

A new color correlation method applied to XRF Al/Si ratios and other lunar remote sensing data

Orbital X-ray fluorescence Al/Si intensity ratios, corrected for variations in solar activity, are correlated with normal albedo, elevation measurements from laser altimetry data, and gamma ray data in the 2.75-8.60 MeV range. Each of these data sets is placed into a digital array consisting of 1/4 deg latitude by 1/4 deg longitude pixels. Information relative to the correlation of Al/Si ratios with each of the other data sets is presented in the following forms: (1) histograms are given for each data set to show the frequency distribution within the areas of common coverage; (2) density plots are produced from the plot of a two-dimensional array consisting of the Al/Si ratio vs the other parameter value for each pixel; and (3) color correlation maps are produced by placing the two-dimensional array into a 3 x 3 matrix consisting of nine equal subarrays containing an equal number of data points.

Clark, P. E.↗

The Kepler DB, a Database Management System for Arrays, Sparse Arrays and Binary Data

The Kepler Science Operations Center stores pixel values on approximately six million pixels collected every 30-minutes, as well as data products that are generated as a result of running the Kepler science processing pipeline. The Kepler Database (Kepler DB) management system was created to act as the repository of this information. After one year of ight usage, Kepler DB is managing 3 TiB of data and is expected to grow to over 10 TiB over the course of the mission. Kepler DB is a non-relational, transactional database where data are represented as one dimensional arrays, sparse arrays or binary large objects. We will discuss Kepler DB's APIs, implementation, usage and deployment at the Kepler Science Operations Center.

McCauliff, Sean↗

Large format imaging arrays for the Atacama Cosmology Telescope

We describe progress in the fabrication, characterization, and production of detector arrays for the Atacama Cosmology Telescope (ACT). The completed ACT instrument is specified to image simultaneously at 145, 225, and 265 GHz using three 32x32 filled arrays of superconducting transition edge sensors (TES) read out with time-division-multiplexed SQUID amplifiers. We present details of the pixel design and testing including the optimization of the electrical parameters for multiplexed readout. Using geometric noise suppression and careful tuning of operation temperature and device bias resistance, the excess noise in the TES devices is balanced with detector speed for interfacing with the ACT optics. The design also accounts for practical tolerances such as transition temperature gradients and scatter that occur in the production of multiple wafers to populate fully the kilopixel cameras. We have developed an implanted absorber layer compatible with our silicon-on-insulator process that allows for tunable optical resistance with requisite on-wafer uniformity and wafer-to-wafer reproducibility. Arrays of 32 elements have been tested in the laboratory environment including electrical, optical, and multiplexed performance. Given this pixel design, optical tests and modeling are used to predict the performance of the filled array under anticipated viewing conditions. Integration of the filled array of pixels with a tuned backshort and dielectric plate in front of the array maximize absorption and the focal plane and suppress reflections. A mechanical design for the build of the full structure is completed and we report on progress toward the construction of a prototype array for first light on the ACT.

Chervenak, J. A.↗

Sub-pixel Spatial Resolution Micro-roughness Measurements with Interlaced Stitching

In this paper we describe a method to increase the spatial resolution of surface micro-roughness measurements. As the surface specifications for precision optics become more demanding, the metrology instruments must cover a broad spatial frequency range. Generally, multiple instruments are used to cover the full range of the specifications. For example, a Fizeau interferometer would be used to test low spatial frequency surface errors, a white light interferometer would be used for mid spatial frequency errors, and an AFM would be used for high spatial frequency errors. For some precision optics, three instruments would be necessary. However, in many applications, an increase in the spatial resolution of a metrology instrument could negate the need for multiple instruments. A solution to increase the spatial resolution of micro-roughness measurements obtained using white light interferometry with "interlaced stitching" will be presented. In "interlaced stitching", multiple interferometric measurements are made as the optic under test (or the CCD array) is laterally shifted at sub-pixel increments. The measurements are then combined to construct a measurement with higher spatial resolution. Initial results obtained while implementing a similar process used to increase the spatial resolution of measurements made with a commercially available Fizeau interferometer will be presented.

Mooney, James T.↗

Quantifying the Effect of Cosmic Ray Showers on the X-IFU Energy Resolution

The X-ray Integral Field Unit (X-IFU) will operate an array of more than 3000 Transition Edge Sensor pixels at 90 mK with an unprecedented energy resolution of 2.5 eV at 7 keV. In space, primary cosmic rays and secondary particles produced in the instrument structure will continuously deposit energy on the detector wafer and induce fluctuations on the pixels’ thermal bath. We have investigated through simulations of the X-IFU readout chain how these fluctuations eventually influence the energy measurement of X-ray photons. Realistic timelines of thermal bath fluctuations at different positions in the array are generated as a function of a thermal model and the expected distribution of the deposited energy of the charged particles. These are then used to model the TES response to these thermal perturbations and their influence on the onboard energy reconstruction process. Overall, we show that with adequate heatsinking, the main energy resolution degradation effect remains minimal and within the associated resolution allocation of 0.2 eV. We further study how a dedicated triggering algorithm could be put in place to flag the rarer large thermal events.

P. Peille↗