Search NASA⌕ Search

SEARCH · Search NASA

Results for “Position Sensitive Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

SU-C-207A-02: Proton Radiography Using Pencil Beam Scanning and a Novel, Low-Cost Range Telescope

Purpose: While the energy of therapeutic proton beams can be adjusted to penetrate to any given depth in water, range uncertainties arise in patients due in part to imprecise knowledge of the stopping power of protons in human tissues [1]. Proton radiography is one approach to reduce the beam range uncertainty [2], thereby allowing for a reduction in treatment margins and dose escalation. Methods: The authors have adapted a novel detector technology based on Micromesh Gaseous Structure (“Micromegas”) for proton therapy beams and have demonstrated fine spatial and time resolution of magnetically scanned proton pencil beams, as well as wide dynamic range for dosimetry [3]. The authors have constructed a prototype imaging system comprised of 5 Micromegas layers. Proton radiographs were obtained downstream of solid water assemblies. The position-sensitive monitor chambers in the IBA proton delivery nozzle provide the beam entrance position. Results: Our technique achieves spatial resolution as low as 300 µm and water-equivalent thickness (WET) resolution as good as 0.02% (60 µm out of 31 cm total thickness). The dose delivered to the patient is kept below 2 cGy. The spatial resolution as a function of sample rate and number of delivered protons is found to be near the theoretical Cramer-Rao lower bound. By extrapolating the CR bound, we argue that the imaging dose could be further lowered to 1 mGy, while still achieving submillimeter spatial resolution, by achievable instrumentation and beam delivery modifications. Conclusion: For proton radiography, high spatial and WET resolution can be achieved, with minimal additional dose to patient, by using magnetically scanned proton pencil beams and Micromegas detectors.

60 APPLIED LIFE SCIENCES↗

Advanced readout methods for superheated emulsion detectors

Superheated emulsions develop visible vapor bubbles when exposed to ionizing radiation. They consist in droplets of a metastable liquid, emulsified in an inert matrix. The formation of a bubble cavity is accompanied by sound waves. Evaporated bubbles also exhibit a lower refractive index, compared to the inert gel matrix. These two physical phenomena have been exploited to count the number of evaporated bubbles and thus measure the interacting radiation flux. Systems based on piezoelectric transducers have been traditionally used to acquire the acoustic (pressure) signals generated by bubble evaporation. Such systems can operate at ambient noise levels exceeding 100 dB; however, they are affected by a significant dead time (>10 ms). An optical readout technique relying on the scattering of light by neutron-induced bubbles has been recently improved in order to minimize measurement dead time and ambient noise sensitivity. Beams of infra-red light from light-emitting diode (LED) sources cross the active area of the detector and are deflected by evaporated bubbles. The scattered light correlates with bubble density. Planar photodiodes are affixed along the detector length in optimized positions, allowing the detection of scattered light from the bubbles and minimizing the detection of direct light from the LEDs. A low-noise signal-conditioning stage has been designed and realized to amplify the current induced in the photodiodes by scattered light and to subtract the background signal due to intrinsic scattering within the detector matrix. The proposed amplification architecture maximizes the measurement signal-to-noise ratio, yielding a readout uncertainty of 6% (±1 SD), with 1000 evaporated bubbles in a detector active volume of 150 ml (6 cm detector diameter). In this work, we prove that the intensity of scattered light also relates to the bubble size, which can be controlled by applying an external pressure to the detector emulsion. This effect can be exploited during the readout procedure to minimize shadowing effects between bubbles, which become severe when the latter are several thousands. The detector we used in this work is based on superheated C-318 (octafluorocyclobutane), emulsified in 100 μm ± 10% (1 SD) diameter drops in an inert matrix of approximately 150 ml. The detector was operated at room temperature and ambient pressure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of measurement and simulation of ATLAS cavern radiation background

Sixteen Medipix2 pixel detector based (MPX) devices were operated at various positions within the ATLAS detector and cavern continuously from early 2008 up to 2013. In addition to photons, each MPX detector is capable to detect charged particles, and neutrons as it is covered with a mask of converter materials dividing its area into regions sensitive to thermal or fast neutrons. The MPX detector network was effectively used for real-time measurements of the spectral characteristics and composition of complex radiation fields in ATLAS. This article reports comparison of the results of measurements performed with MPX detectors during the LHC operation period in 2010 and 2011 with Monte Carlo simulations results from the FLUGG and GCALOR codes. For the purpose of this comparison, the MPX detectors were operated in tracking mode with low threshold (8–10 keV) allowing one to distinguish among particle categories based on the recognition of track patterns left by the particles in the MPX sensitive layer. The comparison of measurements with simulations shows that the agreement between measured and simulated data is satisfactory in most cases within a factor of two.

47 OTHER INSTRUMENTATION↗

First narrow-band search for continuous gravitational waves from known pulsars in advanced detector data

Spinning neutron stars asymmetric with respect to their rotation axis are potential sources of continuous gravitational waves for ground-based interferometric detectors. In the case of known pulsars a fully coherent search, based on matched filtering, which uses the position and rotational parameters obtained from electromagnetic observations, can be carried out. Matched filtering maximizes the signal-to-noise (SNR) ratio, but a large sensitivity loss is expected in case of even a very small mismatch between the assumed and the true signal parameters. For this reason, narrow-band analyses methods have been developed, allowing a fully coherent search for gravitational waves from known pulsars over a fraction of a hertz and several spin-down values. In this paper we describe a narrow-band search of eleven pulsars using data from Advanced LIGO's first observing run. While we have found several initial outliers, further studies show no significant evidence for the presence of a gravitational wave signal. Lastly, we have placed upper limits on the signal strain amplitude lower than the spin-down limit for 5 of the 11 targets over the bands searched: in the case of J1813-1749 the spin-down limit has been beaten for the first time. For an additional 3 targets, the median upper limit across the search bands is below the spin-down limit. This is the most sensitive narrow-band search for continuous gravitational waves carried out so far.

79 ASTRONOMY AND ASTROPHYSICS↗

Apparent brightness of stars and lasers

Foremost among issues affecting the potential use of astrometric techniques to locate and track laser-carrying spacecraft is the apparent brightness of a laser relative to reference stars. Broadband detectors offer improved sensitivity to stars, but not to lasers. The important and fundamental step of calibrating laser and star brightnesses according to detector spectral sensitivity is performed for four representative kinds of broadband detectors, located above and below the atmosphere. Stars are identified according to parameters traditionally used by astronomers: temperature and apparent brightness at visible wavelengths. These are translated into an energy and photon flux for each kind of broadband detector and are then compared with the corresponding flux from a laser. The comparisons are also given as magnitude correction factors. Astrometrists typically characterize the sensitivity of their instruments in terms of the precision with which they can make a relative measurement of position and the minimum brightness needed to achieve that precision. Given this information and the instruments's spectral sensitivity, the calculations described can be used to infer the detectability of a laser and the precision with which it could be located and tracked. Since the limiting brightness quoted for a particular instrument is typically firm to within 4.0 dB, judging a laser's detectability by its visible brightness alone could lead to serious underestimation of the requirements on its effective radiated power. The laser brightness corrections given solve this problem.

Schumaker, B. L.↗

The WIDe-angle GEocoronal Telescope (WIDGET)

We describe the WIDe-angle GEocoronal Telescope, or WIDGET. The telescope is designed to image the cold plasma constituent of the magnetosphere, the plasmasphere, by imaging the He II 304 A emission. It utilizes a spherical normal incidence f/2 mirror with a microchannel plate imaging detector positioned near the focal point of the mirror. The instrument has a 30-deg field of view with a .5-1-deg angular resolution. The mirror has a multilayer coating which, combined with an Al/C filter and the detector response, provides a peak sensitivity of approximately 0.5 ct/sec/Rayleigh/bin at 304 A with a bandpass of about 60 A. The instrument will be flown on a sounding rocket in the Fall of 1992 as a test of its capabilities. It can easily be adapted to different wavelengths (584, 834, and 1216 A) using suitable mirror coatings and filters. In this way, a series of WIDGETs could image different aspects of the inner magnetosphere simultaneously, thus providing a more unified picture of this complex region.

Cotton, Daniel↗

A method for correcting aspect solution errors in ROSAT HRI observations of compact sources

X-ray point sources observed with the ROSAT High Resolution Imager (HRI) often appear elongated over scales of approximately 5 sec-10 sec from the image core. This elongation has been attributed to errors in the attitude correction as the satellite is wobbled during the observations, and affects sources with both soft and hard X-ray spectra. In this paper, I report the results of an attempt to rid a high signal-to-noise observation of the soft X-ray point source HZ 43 of its characteristic elongation. I divided the observation into 181 separate images, each containing photons from only a small region on the detector through which the source passed during the satellite's wobble. By measuring the positions of the individual image centroids, I found clear evidence for systematic offsets from a common mean by up to approximately +/- 3 sec in both right ascension and declination as a function of phase in the satellite wobble. Shifting the subimages to a common center and then restacking them into a single image measurably improved the symmetry of the point-spread function. HRI observations are wobbled primarily to smooth out variations in the pixel-to-pixel sensitivity of the detector and also to extend the lifetime of the microchannel plates in the detector since these decay at a given location as a function of the number of photons detected. However, the elongations introduced by the aspect errors inhibit the identification of possible extended X-ray emission associated with sources such as pulsars and active galactic nuclei. In light of these results, I suggest that until the aspect errors are understood, observations of compact sources, where this effect may be important, should not be wobbled.

Morse, Jon A.↗

Search for Dark Matter with the LZ Experiment

Overwhelming evidence from astrophysical observations indicates that only 20% of the matter in the universe consists of ordinary matter, while the remaining 80% is made of some form of matter called "dark matter''. Although these indirect astrophysical observations convince us that dark matter exists, dark matter has not yet been directly observed. The standard model of particle physics, which has been very successful in explaining the properties of ordinary matter, can neither explain dark matter's presence nor its properties. The discovery and identification of dark matter would have a profound impact on cosmology, astronomy, and particle physics. A leading dark matter candidate consistent with all astrophysical data is a weakly interacting massive particle (WIMP). WIMPs could be detected through their interactions with atomic nuclei in specially designed detectors. Since the collision rates are expected to be very small (a few collisions per year for a 1-ton detector), large detectors with low backgrounds and excellent detection capability for rare collisions are needed to gain knowledge of the nature of dark matter. With dark matter experiments such as the LZ experiment, we are in a position to detect and study this dark matter through sensitive terrestrial direct detection experiments. If no discovery is made with LZ, it will be very difficult to reconcile the sensitivity limit of this experiment with most conventional WIMP scenarios, and alternate paradigms will have to be strongly considered for dark matter. The main focus of the U-M dark matter group over the past two years was on design validation and fabrication for the LZ project, followed by commissioning and operation of the LZ dark matter experiment, and the analysis of the science data during the following funding cycle. The U-M dark matter group had identified two key areas to contribute to the LZ project: the design and fabrication of a radon removal element for the xenon circulation system, and the execution and coordination of prototyping and design validation performed by the small xenon chamber group.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effect of detector dead time on the performance of optical direct-detection communication links

Avalanche photodiodes (APDs) operating in the Geiger mode can provide a significantly improved single-photon detection sensitivity over conventional photodiodes. However, the quenching circuit required to remove the excess charge carriers after each photon event can introduce an undesirable dead time into the detection process. The effect of this detector dead time on the performance of a binary pulse-position-modulated (PPM) channel is studied by analyzing the error probability. It is shown that, when background noise is negligible, the performance of the detector with dead time is similar to that of a quantum-limited receiver. For systems with increasing background intensities, the error rate of the receiver starts to degrade rapidly with increasing dead time. The power penalty due to detector dead time is also evaluated and shown to depend critically on badkground intensity as well as dead time. Given the expected background strength in an optical channel, therefore, a constraint must be placed on the bandwidth of the receiver to limit the amount of power penalty due to detector dead time.

Chen, C.-C.↗

Effect of Detector Dead Time on the Performance of Optical Direct-Detection Communication Links

Avalanche photodiodes (APDs) operating in the Geiger mode can provide a significantly improved single-photon detect ion sensitivity over conventional photodiodes. However, the quenching circuit required to remove the excess charge carriers after each photon event can introduce an undesirable dead time into the detection process. The effect of this detector dead time on the performance of a binary pulse-position-modulted (PPM) channel is studied by analyzing the error probability. It is shown that, when back- ground noise is negligible, the performance of the detector with dead time is similar to that o f a quantum-limited receiver. For systems with increasing background intensities, the error rate of the receiver starts to degrade rapidly with increasing dead time. The power penalty due to detector dead time is also evaluated and shown to depend critically on background intensity as well as dead time. Given the expected background strength in an optical channel, therefore, a constraint must be placed on the bandwidth of the receiver to limit the amount of power penalty due to detector dead time.

Chen, C.-C.↗

Heated Surface Temperatures Measured by Infrared Detector in a Cascade Environment

Investigators have used infrared devices to accurately measure heated surface temperatures. Several of these applications have been for turbine heat transfer studies involving film cooling and surface roughness, typically, these measurements use an infrared camera positioned externally to the test section. In cascade studies, where several blades are used to ensure periodic flow, adjacent blades block the externally positioned camera's views of the test blade. To obtain a more complete mapping of the surface temperatures, researchers at the NASA Glenn Research Center fabricated a probe with an infrared detector to sense the blade temperatures. The probe size was kept small to minimize the flow disturbance. By traversing and rotating the probe, using the same approach as for total pressure surveys, one can find the blade surface temperatures. Probe mounted infrared detectors are appropriate for measuring surface temperatures where an externally positioned infrared camera is unable to completely view the test object. This probe consists of a 8-mm gallium arsenide (GaAs) lens mounted in front of a mercury-cadmium-zinc-tellurium (HgCdZnTe) detector. This type of photovoltaic detector was chosen because of its high sensitivity to temperature when the detector is uncooled. The particular application is for relatively low surface temperatures, typically ambient to 100 C. This requires a detector sensitive at long wavelengths. The detector is a commercial product enclosed in a 9-mm-diameter package. The GaAs lens material was chosen because of its glass-like hardness and its good long-wavelength transmission characteristics. When assembled, the 6.4-mm probe stem is held in the traversing actuator. Since the entire probe is above the measurement plane, the flow field disturbance in the measurement plane is minimized. This particular probe body is somewhat wider than necessary, because it was designed to have replaceable detectors and lenses. The signal for the detector is fed through the hollow probe body. The detector's signal goes to an externally mounted preamplifier. The detector assembly, along with a preamplifier, is calibrated as a function of the surface temperature for various detector temperatures. The output voltage is a function of both the detector and object temperatures.

Boyle, Robert J.↗

Development of a hardened THz energy meter for use on the kilojoule-scale, short-pulse OMEGA EP laser

A highly adaptable and robust terahertz (THz) energy meter is designed and implemented to detect energetic THz pulses from high-intensity (>10 18 W/cm 2 ) laser–plasma interactions on the OMEGA EP. THz radiation from the laser driven target is detected by a shielded pyrometer. A second identical pyrometer is used for background subtraction. The detector can be configured to detect THz pulses in the 1 mm to 30 μm (0.3- to 10-THz) range and pulse energies from joules to microjoules via changes in filtration, aperture size, and position. Additional polarization selective filtration can also be used to determine the THz pulse polarization. The design incorporates significant radiation and electromagnetic pulse shielding to survive and operate within the OMEGA EP radiation environment. We describe the design, operational principle, calibration, and testing of the THz energy meter. The pyrometers were calibrated using a benchtop laser and show linear sensitivity to up to 1000 nJ of absorbed energy. Furthermore, the initial results from four OMEGA EP THz experiments detected up to ~15 μJ at the detector, which can correspond to hundreds of mJ depending on THz emission and reflection models.

47 OTHER INSTRUMENTATION↗

Bayesian Exploration and Surrogate Emulation of Nonlinear Beam-Response Geometry in the LBNF Beamline

Next-generation long-baseline neutrino experiments aim to achieve multi-MW proton beam power while reducing accelerator-induced systematic uncertainties. At Fermilab, the LBNF beamline is designed for 1.2 MW operation with PIP-II and is upgradeable to 2.4 MW. DUNE will probe the three-flavor neutrino paradigm and search for CP violation, requiring precise neutrino-flux normalization and improved control of accelerator-related uncertainties. Within the LBNF beamline, the System for On-Axis Neutrino Detection (SAND) will constrain flux uncertainties using precision near-detector measurements, while the Muon Monitor System (MuMS) will provide beamline diagnostics sensitive to the proton beam, target, and horn configuration. However, the pion phase space relevant for DUNE depends simultaneously on many correlated parameters, including beam centroid, beam width, horn current and alignment, target position, optics shifts, and radiation-induced changes. Consequently, MuMS observables exhibit nonlinear and coupled responses that are difficult to characterize using traditional one-parameter scans. To address this challenge, we are developing a Bayesian Exploration framework coupled to physics-informed surrogate emulators trained on Geant4 beamline simulations. Gaussian-process emulators provide both fast predictions and uncertainty estimates, enabling adaptive selection of new simulation points in beam-parameter space. As an initial demonstration, we construct surrogate emulators for MuMS response observables using a verified simulation campaign spanning proton-beam steering conditions. The emulators reproduce the simulated dependence of MuMS centroid and gradient observables while providing predictive uncertainties, and serve as the foundation for future multidimensional exploration including beam width, horn current, and additional beamline parameters. This work establishes a framework for uncertainty-aware beam monitoring, adaptive simulation campaigns, and rapid beam-response inference for future DUNE operations.

Ganguly, Sudeshna [Fermilab] (ORCID:00000003163482↗

Solar maximum mission/ultraviolet spectrometer and polarimeter studies

This final report for NASA Contract No. NAS8-35921 describes various studies performed for the Ultraviolet Spectrometer and Polarimeter (UVSP) experiment, one of several instruments on the Solar Maximum Mission (SMM) satellite which was launched on 14 February 1980. The UVSP consisted primarily of a Gregorian telescope and an Ebert-Fastie spectrometer with a polarimeter that could be inserted into the light path. The spacecraft and most of the instruments, including the UVSP, operated successfully until 23 November 1980, when part of the SMM attitude control system (fine pointing control) failed. The UVSP was then unable to observe the Sun until 18 April 1984, when the SMM was visited by the space shuttle and the attitude control module was replaced by astronauts. The SMM mission ended when the spacecraft reentered the atmosphere of the Earth and was thereby destroyed on 2 December 1989. The topics covered in this report include the following: (1) ultraviolet stellar polarimetry (probably the first such attempted measurement); no polarization as detected and the upper limits, based on the sensitivity as determined by the observed count rate, are rather high; (2) an investigation into the possible position of the UVSP wavelength drive after it became stuck on 26 April 1985; (3) fast timing tests for sit-and-state observations involving one or two detectors; (4) development of computer subroutines to allow the calculation of the component of the SMM spacecraft orbital velocity along the line of sight to the Sun at any desired time during the 1984/1985 period when the UVSP wavelength drive was operating properly; (5) listing of published research papers; (6) description of the UVSP catalog of observations; and (7) description of UVSP calibration report and data users guide.

Henze, William, Jr.↗

Machine Learning-based Cyber-Physical Anomaly Detection in Wide Area Voltage Control Systems

Wide-area voltage control systems (WAVCS) are widely deployed in power grid to improve the voltage stability in transmission system using Flexible AC Transmission System (FACTS) devices. The WAVCS relies on wide-area measurement and control signals for closed-loop control of FACTS devices to improve the transient voltage stability in power grid in real-time. Since the WAVCS utilizes a cyber-layer communication during its normal operation, they are susceptible to cyber attacks from adversaries which can lead to a voltage collapse if the attacks go undetected and unmitigated. This paper proposes a supervised machine learning (ML)-based anomaly detection algorithm for detecting various stealthy cyber attacks in the context of WAVCS cybersecurity. In particular, a fuzzy logic-based wide-area controller, as proposed by the Bonneville Power Administration (BPA), is implemented on the Kundur’s four machine two-area system that is integrated with a static var compensator (SVC) to improve voltage profile on sensitive buses. Later, different types of data integrity attacks, including pulse and ramp attacks, are considered on the wide-area measurement and control signals to analyze the performance of the proposed anomaly detector. Our experimental evaluation shows a promising performance with a high true-positive rate (more than 99%) and low false-negative rate (less than 1%) while exhibiting a small prediction time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Room PET Scanner for Natural Environment Neuroscience Research

A room size PET scanner for neuroscience research is proposed in which subjects can move about freely in a natural environment. This scanner, termed RoomPET, would open new frontiers in the study of dynamic brain function. The key to a feasible system is PET detectors with a limited vertical dimension that may translate up and down to keep the brain in the field of view. Head position can be tracked by an array of video cameras, providing real-time data to guide detector motion and for motion-corrected image reconstruction. For a point in the center of the room and centered within the vertical field of view of the detectors, geometric sensitivity ranges between 4 and 18% for room widths of 2 to 3 m and detectors with vertical dimensions of 15 to 40 cm. Spatial resolution is dominated by annihilation photon non-colinearity due to the large detector separation. This non-colinearity contribution for F-18 is 4.4 and 6.6 mm full width at half maximum (FWHM) at the center of 2 ×2 and 3×3m 2 rooms, respectively, for a line of response orthogonal to the opposite walls. With pixelated scintillation crystal elements 2 mm on a side the system resolution for F-18 radiotracers is estimated at 4.5 and 6.7 mm FWHM for room widths of 2 and 3 m, respectively. A RoomPET system would advance the understanding of brain function in healthy humans and in those with neurological diseases, disorders and brain injury.

Smith, Mark F.↗

Investigation into Practical Implementations of a Zero Knowledge Protocol.

In recent years, the concept of Zero Knowledge Protocols (ZKP) as a useful approach to nuclear warhead verification has become increasingly popular. Several implementations of ZKP have been proposed, driving technology development toward proof of concept demonstrations. Whereas proposed implementations seem to fall within the general class of template-based techniques, all physical implementations of ZKPs proposed to date have a complication: once the instrumentation is prepared, it is no longer authenticatable; the instrument physically contains sensitive information. In this work we explore three different concepts that may offer more authenticatable and practical ZKP implementations and evaluate the sensitive information that may be at risk when doing so: sharing a subset of detector counts in a preloaded image (with spatial information removed), real-time image subtraction, and a new concept, CONfirmation using a Fast-neutron Imaging Detector with Anti-image NULL-positive Time Encoding (CONFIDANTE). CONFIDANTE promises to offer an almost ideal implementation of ZKP: a positive result is indicated by a constant rate at all times enabling the monitoring party the possibility of full access to the instrument before, during, and after confirmation. A prototype of CONFIDANTE was designed, built, and its performance evaluated in a series of measurements of several objects including a set of plutonium dioxide Hemispheres. Very encouraging results proving feasibility are presented. 1 Rebecca is currently a graduate student in Nuclear Engineering at UC Berkeley

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A field-ionization neutral detector - FIND

The field ionization neutral detector FIND operates according to the following principle: Neutral atoms are attracted toward the field ionization tips since they are polarized by the electric field of the tips. The atoms are singly ionized and repelled by the positive potential of the tips toward the detector situated behind a grid at ground potential. The ions deposit in the detector their kinetic energies, typically 26 keV, corresponding to the potential difference between the ionization region and the detector. Laboratory results show that FIND can have the resolution, sensitivities and durability required to perform in situ measurements of neutral H and He fluxes in interplanetary space, cometary halos and exospheres.

Curtis, C. C.↗