Search NASA⌕ Search

SEARCH · Search NASA

Results for “Position Sensitive Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Improving Chirped Fiber Bragg Grating Resolution for Position-Sensitive Sensors in Shock- and Detonation-Driven Experiments

Chirped fiber Bragg gratings (CFBGs) are robust diagnostic sensors that are widely used to track detonation-driven and shock wave propagation. CFBGs are inscribed with a linearly chirped periodic index of refraction changes that alter the Bragg wavelength along the length of the probe. The light return of each individual Bragg element is captured by a detector at a unique time to map the full reflected spectrum. The CFBG spectrum is measured with a dispersive Fourier transform of the reflected light that temporally stretches the spectrum to increase spatial resolution and make a one-to-one map of the wavelength on a time axis. Here, we propose an improvement of CFBG temporal resolution by incorporating two co-linear laser pulses with orthogonal polarization states and a 5 ns time offset. The two separate signals were split and tracked by two separate detectors. An oscilloscope captured good separation in the signals, and two separate spectrograms were generated and interleaved in the post-processing of the data. This novel technique doubled the CFBG temporal resolution and led to a doubled location resolution. As a proof-of-concept of this technique, the resolution improvement was compared between standard CFBG measurements and the two polarization states method on a position-sensitive CFBG sensor. CFBG resolution doubling will advance sensor capabilities and will have a direct impact on improving capture and analysis in dynamic, high-explosive experiments.

42 ENGINEERING↗

High Precision Track-Based Alignment of the Tracking Detector of the g-2 Experiment

In order for the analysis of data from the tracking detector to reduce the systematic uncertainty on the a_μ measurement and improve the sensitivity to a muon electric dipole moment, the internal position of the tracking modules must be known to a high level of precision. Track-based alignment was implemented with data from Run 1 using the Millepede II framework. An overview of the alignment methods, as well as the verification of alignment with simulation, will be given. A significant improvement in the mean p-value distribution and the fraction of reconstructed tracks after the alignment was achieved. A comparison of the accuracy in the determination of the beam's spatial distribution as a function of time will be presented before and after the alignment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and Development of an Automated Instrument for Measuring Radioactivity in an Excavator Bucket - 16246

Increasing interest and emphasis is being given to the presence of radioactive contamination in the environment and the methods by which this contamination can be remediated. Radioactive contamination may arise from industrial process including the operation of nuclear facilities. It may also arise from the enhancement of naturally occurring radioactive material by industrial processes. An area of particular concern is the remediation of soil and rubble with radioactive contamination. Traditional methods of soil remediation involve sampling followed by the excavation of areas where contamination is found. The soil removal process is normally very inefficient and can involve multiple handling of excessive quantities of soil and ultimately an over estimate of the quantity of soil with radioactive contamination. In order to both minimize material handling and to reduce the final volume of contaminated material, which must be handled for disposal, a sensitive instrument has been developed and tested which is designed to measure the radioactive content of an excavator bucket. The instrument detector is positioned automatically just above the open top of the bucket and the measurement employs a high efficiency sodium iodide crystal which has a graded shadow shield to reduce the effect of background radioactivity. The measurement efficiency is enhanced as the detector is located in close proximity to the soil in the bucket and the thick steel shell of the bucket acts as a shield to further reduce the effect of background from the ground below. The method has obvious advantages over methods, which attempt to measure the potentially radioactive soil through the shielding provided by the thick steel bucket shell. As the first stage of the bucket measurement the excavator operator fills the bucket and locates it in a designated position with the open top of the bucket facing upwards, close to the operator cab. A measurement technician, located outside the danger area of the excavator boom, begins the measurement using a tablet computer with a wireless connection to the instrument. The shielded detector is moved from a storage position above the operator cab to the measurement position close to the open surface of the excavator bucket. Once the measurement is completed in typically one to two minutes, the detector is repositioned in its storage location and the measurement data is transmitted to the tablet computer. At this point the measurement technician makes the decision based on the measurement results as to how to disposition the bucket contents. Typically contaminated material will be transferred to a vehicle for off-site disposal. Alternatively, and this is the great advantage of this technique, uncontaminated material may be returned directly to the site of the excavation without the need for further handling. The development, detailed design and preliminary testing of the instrument are described. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-T-442: Sensitivity of Quality Assurance Tools to Delivery Errors On a Magnetic Resonance-Imaging Guided Radiation Therapy (MR-IGRT) System

Purpose: To test the sensitivity of the quality assurance (QA) tools actively used on a clinical MR-IGRT system for potential delivery errors. Methods: Patient-specific QA procedures have been implemented for a commercially available Cobalt-60 MR-IGRT system. The QA tools utilized were a MR-compatible cylindrical diode-array detector (ArcCHECK) with a custom insert which positions an ionization chamber (Exradin A18) in the middle of the device, as well as an in-house treatment delivery verification program. These tools were tested to investigate their sensitivity to delivery errors. For the ArcCHECK and ion chamber, a baseline was established with a static field irradiation to a known dose. Variations of the baseline were investigated which included rotated gantry, altered field size, directional shifts, and different delivery time. In addition, similar variations were tested with the automated delivery verification program that compared the treatment parameters in the machine delivery logs to the ones in the plan. To test the software, a 3-field conformal plan was generated as the baseline. Results: ArcCHECK noted at least a 13% decrease in passing rate from baseline in the following scenarios: gantry rotation of 1 degree from plan, 5mm change in field size, 2mm lateral shift, and delivery time decrease. Ion chamber measurements remained consistent for these variations except for the 5 second decrease in delivery time scenario which resulted in an 8% difference from baseline. The delivery verification software was able to detect and report the simulated errors such as when the gantry was rotated by 0.6 degrees, the beam weighting was changed by a percent, a single multileaf collimator was moved by 1cm, and the dose was changed from 2 to 1.8Gy. Conclusion: The results show that the current tools used for patient specific QA are capable of detecting small errors in RT delivery with presence of magnetic field.

60 APPLIED LIFE SCIENCES↗

GRAPH — an readout ASIC for large MCP based detectors

We present a programmable 16 channel, mixed signal, low power readout ASIC, having the project historically named Gigasample Recorder of Analog waveforms from a PHotodetector (GRAPH). It is designed to read large aperture single photon imaging detectors using micro channel plates for charge multiplication, and measuring the detector's response on crossed strips anodes to extrapolate the incoming photon position. Each channel consists of a fast, low power and low noise charge sensitive amplifier, which provides a myriad of coarse and fine programmable options for gain and shaping settings. Further, the amplified signal is recorded using, to our knowledge novel, the Hybrid Universal sampLing Architecture (HULA) ADC. A kind of mixed signal double buffer memory, that enables concurrent waveform recording, and selected event digitized data extraction. The sampling frequency is freely adjustable between few kHz up to 125 MHz, while the chip's internal digital memory holds a history 2048 samples for each channel, with a digital headroom of 12 bits. An optimized region of interest sample-read algorithm allows to extract the information just around the event pulse peak, while selecting the next event, thus substantially reducing the operational dead time. The chip is designed in 130 nm TSMC CMOS technology, and its power consumption is around 47 mW per channel.

47 OTHER INSTRUMENTATION↗

Search for α decay of Te 104 with a novel recoil-decay scintillation detector

A search for superallowed α decay of N = Z nuclei Te 104 and Xe 108 was carried out using a novel recoil-decay scintillator detector at the tandem accelerator facility at the Japan Atomic Energy Agency (JAEA). In this study, inorganic crystal scintillation material YAP:Ce (yttrium aluminum perovskite) coupled to a position-sensitive photomultiplier tube (PSPMT) was implemented for the first time in a radioactive decay experiment. Residues from the fusion-evaporation reaction Ni 58 + Fe 54 → Xe * 112 were separated by the JAEA Recoil Mass Separator (RMS) and implanted into the YAP:Ce crystal. α decays of neutron-deficient tellurium isotopes were identified and proton emission of I 109 was observed. The α -decay chain Xe 109 → Te 105 → Sn 101 was recorded with a time interval of 960 ns between two α pulses. Position localization in the crystal for decays and ions in the energy range from hundreds of keV to 60 MeV was achieved with an accuracy of 0.67 mm, proving that this detector is capable of making temporal and spatial correlations for fast decay events. No conclusive evidence was found for the decay chain Xe 108 → Te 104 → Sn 100 within 3 days of experiment. However, two events were observed with properties consistent with the reported observation at the Fragment Mass Analyzer (FMA), but with a separation between signals of less than 4 ns. The cross section limit of 130 pb was obtained for production of two events of Xe 108 , about an order of magnitude below the expectation based on earlier cross section measurements and the HIVAP fusion-evaporation code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-T-602: Patient-Specific Online Dose Verification Based On Transmission Detector Measurements

Purpose: Intensity modulated radiotherapy requires a comprehensive quality assurance program in general and ideally independent verification of dose delivery. Since conventional 2D detector arrays allow only pre-treatment verification, there is a debate concerning the need of online dose verification. This study presents the clinical performance, including dosimetric plan verification in 2D as well as in 3D and the error detection abilities of a new transmission detector (TD) for online dose verification of 6MV photon beam. Methods: To validate the dosimetric performance of the new device, dose reconstruction based on TD measurements were compared to a conventional pre-treatment verification method (reference) and treatment planning system (TPS) for 18 IMRT and VMAT treatment plans. Furthermore, dose reconstruction inside the patient based on TD read-out was evaluated by comparing various dose volume indices and 3D gamma evaluations against independent dose computation and TPS. To investigate the sensitivity of the new device, different types of systematic and random errors for leaf positions and linac output were introduced in IMRT treatment sequences. Results: The 2D gamma index evaluation of transmission detector based dose reconstruction showed an excellent agreement for all IMRT and VMAT plans compared to reference measurements (99.3±1.2)% and TPS (99.1±0.7)%. Good agreement was also obtained for 3D dose reconstruction based on TD read-out compared to dose computation (mean gamma value of PTV = 0.27±0.04). Only a minimal dose underestimation within the target volume was observed when analyzing DVH indices (<1%). Positional errors in leaf banks larger than 1mm and errors in linac output larger than 2% could clearly identified with the TD. Conclusion: Since 2D and 3D evaluations for all IMRT and VMAT treatment plans were in excellent agreement with reference measurements and dose computation, the new TD is suitable to qualify for routine treatment plan verification. Funding Support, Disclosures, and Conflict of Interest: COIs: Frank Lohr: Elekta: research grant, travel grants, teaching honoraria IBA: research grant, travel grants, teaching honoraria, advisory board C-Rad: board honoraria, travel grants Frederik Wenz: Elekta: research grant, teaching honoraria, consultant, advisory board Zeiss: research grant, teaching honoraria, patent Hansjoerg Wertz: Elekta: research grant, teaching honoraria IBA: research grant.

61 RADIATION PROTECTION AND DOSIMETRY↗

New detector for use in fast neutron radiography

We have developed and tested a new type detector for use in the fast neutron (FN) imaging radiography applications. FN radiography is generally used for nondestructive material testing, medical and biology applications, border patrol, transportation and cargo screening tasks. It is complementary to other types of radiography, providing additional information on light element content of the material samples. Distinct from other FN imagers presently known, our device implements a neutron-sensitive scintillator attached to a position-sensitive photomultiplier tube (PSPMT), and operates in an event-by-event readout mode, acquiring energy, timing, and pulse shape information for all detected radiation events. The information is used to help separate events of FN interactions in the scintillator from the background events caused by the electronics noise and by the other types of background radiation. Selection of pure fast neutron events in the final image allows us to achieve ultimate image contrast and resolution, as compared with other types of FN imaging devices operating most commonly in an integration mode, in which the detector?s dark noise and radiation background dilute the images. The detector performance for FN imaging application was tested using D-D neutron generator, designed and manufactured by Adelphi Technology, Inc. This essentially point-like neutron source operates in continuous mode producing up to 109 of 2.5 MeV neutrons per second. Samples made of metals plastic and other material were used to measure the detector resolution, efficiency and uniformity. Results of these tests are presented and discussed. Fig. 1 shows one of the test FN radiographic images obtained using the sample made of 11 styrene plastic strips. All strips are squares 4.8 x 4.8 mm2 with six different lengths 10 to 60 mm with 10 mm increment. [A] [B] [C] Fig. 1. [A]-layout of the test sample; [B]-raw FN shadow image of the sample; [C]-map of the plastic strips as they appear on the image, with measured FN absorption factor shown in percent. Both X and Y position resolution of the FN imaging detector are estimated to be less than 0.5 mm (sigma) based on the analysis of the edges of the strip shadows in the plot. Because this detector shows the fraction-of-a-millimeter resolution desirable for most of FN applications, and is built using radiation hard materials, we believe it could be a good alternative to other FN imaging systems based on CCD or solid state detectors. In addition, having a sub-nanosecond timing resolution, it is suitable for the time-of-flight energy-resolved FN imaging.

Popov, V.↗

Characterization of a collimated neutron imager for low-rate fast neutron imaging

Spatial localization of special nuclear materials (SNM) via their neutron signatures amidst background requires knowledge of the background neutron environment or a means of separating a source from background based on low amounts of information. This requirement has created the need for characterizing the spatial distribution of the cosmogenic neutron background. Neutron scatter cameras have been developed and optimized for rapid detection of high activity sources, but have low imaging efficiency, making it difficult to use them to characterize low rate diffuse sources, such as the neutron background. The Low Intensity Neutron Imaging System (LINIS) is a collimated neutron imager that has been designed and optimized for imaging diffuse cosmogenic neutron background in the energy range of 0.5–15 MeV. LINIS operates using 16 liquid scintillation detectors shielded by ultra-high molecular weight polyethylene cylindrical collimators in a staggered orientation and rotates to 7 discrete positions, giving it roughly 2π sensitivity. Finally, LINIS has been characterized using (α, n) and fission neutron sources using two imaging techniques for neutron source localization, simple backprojection and Maximum Likelihood Expectation Maximization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sequential x-ray diffraction topography at 1-BM x-ray optics testing beamline at the advanced photon source

We report progress on implementation and commissioning of sequential X-ray diffraction topography at 1-BM Optics Testing Beamline of the Advanced Photon Source to accommodate growing needs of strain characterization in diffractive crystal optics and other semiconductor single crystals. The setup enables evaluation of strain in single crystals in the nearly-nondispersive double-crystal geometry. Si asymmetric collimator crystals of different crystallographic orientations were designed, fabricated and characterized using in-house capabilities. Imaging the exit beam using digital area detectors permits rapid sequential acquisition of X-ray topographs at different angular positions on the rocking curve of a crystal under investigation. Results on sensitivity and spatial resolution are reported based on experiments with high-quality Si and diamond crystals. The new setup complements laboratory-based X-ray topography capabilities of the Optics group at the Advanced Photon Source.

43 PARTICLE ACCELERATORS↗

Simultaneous ambient pressure x-ray photoelectron spectroscopy and grazing incidence x-ray scattering in gas environments

We have developed an experimental system to simultaneously measure surface structure, morphology, composition, chemical state, and chemical activity for samples in gas phase environments. This is accomplished by simultaneously measuring x-ray photoelectron spectroscopy (XPS) and grazing incidence x-ray scattering in gas pressures as high as the multi-Torr regime while also recording mass spectrometry. Scattering patterns reflect near-surface sample structures from the nano-scale to the meso-scale, and the grazing incidence geometry provides tunable depth sensitivity of structural measurements. Scattered x rays are detected across a broad range of angles using a newly designed pivoting-UHV-manipulator for detector positioning. At the same time, XPS and mass spectrometry can be measured, all from the same sample spot and under ambient conditions. To demonstrate the capabilities of this system, we measured the chemical state, composition, and structure of Ag-behenate on a Si(001) wafer in vacuum and in O 2 atmosphere at various temperatures. These simultaneous structural, chemical, and gas phase product probes enable detailed insights into the interplay between the structure and chemical state for samples in gas phase environments. The compact size of our pivoting-UHV-manipulator makes it possible to retrofit this technique into existing spectroscopic instruments installed at synchrotron beamlines. Because many synchrotron facilities are planning or undergoing upgrades to diffraction limited storage rings with transversely coherent beams, a newly emerging set of coherent x-ray scattering experiments can greatly benefit from the concepts we present here.

47 OTHER INSTRUMENTATION↗

Resolution and sensitivity of a Fabry-Perot interferometer with a photon-number-resolving detector

With photon-number resolving detectors, we show compression of interference fringes with increasing photon numbers for a Fabry-Perot interferometer. This feature provides a higher precision in determining the position of the interference maxima compared to a classical detection strategy. We also theoretically show supersensitivity if N-photon states are sent into the interferometer and a photon-number resolving measurement is performed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method and system for controlling the position of a beam of light

An method and system for laser beam tracking and pointing is based on a conventional position sensing detector (PSD) or quadrant cell but with the use of amplitude-modulated light. A combination of logarithmic automatic gain control, filtering, and synchronous detection offers high angular precision with exceptional dynamic range and sensitivity, while maintaining wide bandwidth. Use of modulated light enables the tracking of multiple beams simultaneously through the use of different modulation frequencies. It also makes the system resistant to interfering light sources such as ambient light. Beam pointing is accomplished by feeding back errors in the measured beam position to a beam steering element, such as a steering mirror. Closed-loop tracking performance is superior to existing methods, especially under conditions of atmospheric scintillation.

47 OTHER INSTRUMENTATION↗

Uniformity measurements and new positioning algorithms for wavelength-shifting fiber neutron detectors

Wavelength-shifting (WLS) fiber scintillator detectors were successfully installed at two neutron powder diffractometers at the Spallation Neutron Source (SNS). But, they have the following second-order disadvantages: (i). they cannot have both high efficiency and images free of ghosting (position misassignment) concomitantly; (ii). the apparent detection efficiency and spatial resolution are not uniform. These issues are related to the diffusion of scintillation photons and the fluctuation in the number of photons (quantum noise) collected by photo-multiplier tubes (PMTs). Therefore, to mitigate these two issues, we developed two statistics-based positioning algorithms, i.e., a centroid algorithm (CEA) and a correlation algorithm (CA). Compared with the generally used maximum-photon algorithm (MPA), CEA eliminates the ghosting with only about a 10% loss in detection efficiency, and provides better uniformity in detection efficiency and intrinsic background. CA can effectively eliminate ghosting too, but the loss of efficiency at the group boundaries of PMTs is large. Our results indicate that both algorithms can reduce the influence of quantum noise on the neutron positioning.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vapor-Phase-Gating-Induced Ultrasensitive Ion Detection in Graphene and Single-Walled Carbon Nanotube Networks

Designing ultrasensitive detectors often requires complex architectures, high-voltage operations, and sophisticated low-noise measurements. Here, it is shown that simple low-bias two-terminal DC-conductance values of graphene and single-walled carbon nanotubes are extremely sensitive to ionized gas molecules. Incident ions form an electrode-free, dielectric- or electrolyte-free, bias-free vapor-phase top-gate that can efficiently modulate carrier densities up to ≈0.6 × 10 13 cm -2 . Surprisingly, the resulting current changes are several orders of magnitude larger than that expected from conventional electrostatic gating, suggesting the possible role of a current-gain inducing mechanism similar to those seen in photodetectors. These miniature detectors demonstrate charge–current amplification factor values exceeding 10 8 A C -1 in vacuum with undiminished responses in open air, and clearly distinguish between positive and negative ions sources. At extremely low rates of ion incidence, detector currents show stepwise changes with time, and calculations suggest that these stepwise changes can result from arrival of individual ions. Lastly, these sensitive ion detectors are used to demonstrate a proof-of-concept low-cost, amplifier-free, light-emitting-diode-based low-power ion-indicator.

36 MATERIALS SCIENCE↗

The BetaCage, an ultra-sensitive screener for surface contamination

Material screening for identifying low-energy electron emitters and alpha-decaying isotopes is now a prerequisite for rare-event searches (e.g., dark-matter direct detection and neutrinoless double-beta decay) for which surface radiocon-tamination has become an increasingly important background. The BetaCage, a gaseous neon time-projection chamber, is a proposed ultra-sensitive (and nondestructive) screener for alpha-and beta-emitting surface contaminants to which existing screening facilities are insufficiently sensitive. Sensitivity goals are 0.1 betas keV{sup −1} m{sup −2} day{sup −1} and 0.1 alphas m{sup −2} day{sup −1}, with the former limited by Compton scattering of photons in the screening samples and (thanks to tracking) the latter expected to be signal-limited; radioassays and simulations indicate backgrounds from detector materials and radon daughters should be subdominant. We report on details of the background simulations and detector design that provide the discrimination, shielding, and radiopurity necessary to reach our sensitivity goals for a chamber with a 95 × 95 cm{sup 2} sample area positioned below a 40 cm drift region and monitored by crisscrossed anode and cathode planes consisting of 151 wires each.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of 1eNp0π Charged-Current Electron Neutrino Cross Section on Argon in the NuMI Beam at ICARUS

The Short-Baseline Neutrino (SBN) Program is designed to probe short-baseline neutrino anomalies, including the LSND electron neutrino excess and the MiniBooNE low-energy excess. Essential to interpreting these anomalies and to the success of future experiments like DUNE, is the precise measurement of neutrino-argon interaction cross sections. The program utilizes two liquid argon time projection chamber (LArTPC) detectors: the Short-Baseline Near Detector (SBND) located 110 meters downstream from the Booster Neutrino Beam (BNB) target, and the ICARUS detector positioned 600 meters downstream. Additionally, the ICARUS detector lies off-axis to the NuMI beamline, providing a unique, high-statistics flux of electron neutrinos and sensitivity to energies that overlap with the DUNE spectrum. To analyze the data from these detectors, we have begun employing a machine-learning-based reconstruction algorithm referred to as “Scalable Particle Imaging with Neural Embeddings” (SPINE). SPINE has shown improvement in the ability to reconstruct the properties of final state particles in the detector, like the particle ID and momentum, with the potential to enhance the quality of measurements achievable within the SBN Program e.g., the resolution on kinematics used in differential cross section extraction. This poster presents progress toward measuring the electron neutrino argon interaction cross section in the 1eNp0π topology using the NuMI beam, highlighting the impact of SPINE through the ability to select signal events across a wide kinematic range without sacrificing background rejection power.

Carber, Dan [Colorado State U.] (ORCID:00090006451↗