At least 469 records · Page 26

HESS-II reconstruction strategy and performance in the low-energy (20-150 GeV) domain

In mid-2009 a notable upgrade of the H.E.S.S. telescope system will take place: a new telescope with a 600 m{sup 2} mirror area and very-high-resolution camera (0.07 deg.) will be positioned at the centre of the present configuration, with the aim of lowering the threshold and enhance its sensitivity in the 100 GeV to several TeV energy range. HESS-II will permit the investigation of the lower energy {gamma}-ray spectra in various cosmic accelerators, giving information on the origin of the {gamma}-rays observed, and will detect AGNs with a redshift greater than 0.2 (being less affected by absorption by Extragalactic Background Light--EBL--in this energy range) and will search for new classes of very high energy {gamma}-ray emitters (pulsars, microquasars, GRB, and dark matter candidates)

79 ASTRONOMY AND ASTROPHYSICS↗

Coherency of su(1,1)-Barut-Girardello type and entanglement for spherical harmonics

Barut-Girardello coherent states corresponding to the (l-m)- and (l+m)-integer discrete irreducible representations of su(1,1) Lie algebra are calculated by the spherical harmonics Y{sub lm}({theta},{phi}). Their explicit compact forms and also, to realize the resolution of the identity, their corresponding positive definite measures on the complex plane are obtained in terms of the known functions. It is also shown that coherent states of both positive and negative representations separately lead us to construct new representation bases for su(1,1) Lie algebra. Then, it is shown that the su(1,1)-Barut-Girardello coherent states corresponding to two particles containing the spatial parity symmetries of a bipartite quantum system can be entangled in ten different ways.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of the microwave, terahertz, and far infrared spectra of monodeuterated methanol CH{sub 2}DOH up to J = 26, K = 11, and o{sub 1}

The first theoretical approach aimed at accounting for the energy levels of a non-rigid molecule displaying asymmetric-top asymmetric-frame internal rotation is developed. It is applied to a line position analysis of the high-resolution spectrum of the non-rigid CH{sub 2}DOH molecule and allows us to carry out a global analysis of a data set consisting of already available data and of microwave and far infrared transitions measured in this work. The analysis is restricted to the three lowest lying torsional levels (e{sub 0}, e{sub 1}, and o{sub 1}), to K ⩽ 11, and to J ⩽ 26. For the 8211 fitted lines, the unitless standard deviation is 2.4 and 103 parameters are determined including kinetic energy, hindering potential, and distortion effects parameters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Focal depth measurement of scanning helium ion microscope

When facing the challenges of critical dimension measurement of complicated nanostructures, such as of the three dimension integrated circuit, characterization of the focal depth of microscopes is important. In this Letter, we developed a method for characterizing the focal depth of a scanning helium ion microscope (HIM) by using an atomic force microscope tip characterizer (ATC). The ATC was tilted in a sample chamber at an angle to the scanning plan. Secondary electron images (SEIs) were obtained at different positions of the ATC. The edge resolution of the SEIs shows the nominal diameters of the helium ion beam at different focal levels. With this method, the nominal shapes of the helium ion beams were obtained with different apertures. Our results show that a small aperture is necessary to get a high spatial resolution and high depth of field images with HIM. This work provides a method for characterizing and improving the performance of HIM.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

MILLIMETER DUST EMISSION IN THE GQ LUP SYSTEM

We present SubMillimeter Array observations of the GQ Lup system at 1.3 mm wavelength with 0.''4 ({approx}60 AU) resolution. Emission is detected from the position of the primary star, GQ Lup A, and is marginally resolved. No emission is detected from the substellar companion, GQ Lup B, 0.''7 away. These data, together with models of the spectral energy distribution, suggest a compact disk around GQ Lup A with mass {approx}3 M {sub Jup}, perhaps truncated by tidal forces. There is no evidence for a gap or hole in the disk that might be the signature of an additional inner companion body capable of scattering GQ Lup B out to {approx}100 AU separation from GQ Lup A. For GQ Lup B to have formed in situ, the disk must have been much more massive and extended.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Low-Power, Radiation-Resistant, Silicon-Drift-Detector Array for Extraterrestrial Element Mapping

We are developing a modular Silicon Drift Detector (SDD) X-Ray Spectrometer (XRS) for measuring the abundances of light surface elements (C to Fe) fluoresced by ambient radiation on remote airless bodies. The value of fluorescence spectrometry for surface element mapping is demonstrated by its inclusion on three recent lunar missions and by exciting new data that have recently been announced from the Messenger Mission to Mercury. The SDD-XRS instrument that we have been developing offers excellent energy resolution and an order of magnitude lower power requirement than conventional CCDs, making much higher sensitivities possible with modest spacecraft resources. In addition, it is significantly more radiation resistant than x-ray CCDs and therefore will not be subject to the degradation that befell recent lunar instruments. In fact, the intrinsic radiation resistance of the SDD makes it applicable even to the harsh environment of the Jovian system where it can be used to map the light surface elements of Europa. In this paper, we first discuss our element-mapping science-measurement goals. We then derive the necessary instrument requirements to meet these goals and discuss our current instrument development status with respect to these requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pulse-resolved intensity measurements at a hard X-ray FEL using semi-transparent diamond detectors

Solid-state ionization chambers are presented based on thin diamond crystals that allow pulse-resolved intensity measurements at a hard X-ray free-electron laser (FEL), up to the 4.5 MHz repetition rate that will become available at the European XFEL. Due to the small X-ray absorption of diamond the thin detectors are semi-transparent which eases their use as non-invasive monitoring devices in the beam. FELs are characterized by strong pulse-to-pulse intensity fluctuations due to the self-amplified spontaneous emission (SASE) process and in many experiments it is mandatory to monitor the intensity of each individual pulse. Two diamond detectors with different electrode materials, beryllium and graphite, were tested as intensity monitors at the XCS endstation of the Linac Coherent Light Source (LCLS) using the pink SASE beam at 9 keV. The performance is compared with LCLS standard monitors that detect X-rays backscattered from thin SiN foils placed in the beam. In conclusion, the graphite detector can also be used as a beam position monitor although with rather coarse resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-C-207-01: Four-Dimensional Inverse Geometry Computed Tomography: Concept and Its Validation

Purpose: In past few years, the inverse geometry computed tomography (IGCT) system has been developed to overcome shortcomings of a conventional computed tomography (CT) system such as scatter problem induced from large detector size and cone-beam artifact. In this study, we intend to present a concept of a four-dimensional (4D) IGCT system that has positive aspects above all with temporal resolution for dynamic studies and reduction of motion artifact. Methods: Contrary to conventional CT system, projection data at a certain angle in IGCT was a group of fractionated narrow cone-beam projection data, projection group (PG), acquired from multi-source array which have extremely short time gap of sequential operation between each of sources. At this, for 4D IGCT imaging, time-related data acquisition parameters were determined by combining multi-source scanning time for collecting one PG with conventional 4D CBCT data acquisition sequence. Over a gantry rotation, acquired PGs from multi-source array were tagged time and angle for 4D image reconstruction. Acquired PGs were sorted into 10 phase and image reconstructions were independently performed at each phase. Image reconstruction algorithm based upon filtered-backprojection was used in this study. Results: The 4D IGCT had uniform image without cone-beam artifact on the contrary to 4D CBCT image. In addition, the 4D IGCT images of each phase had no significant artifact induced from motion compared with 3D CT. Conclusion: The 4D IGCT image seems to give relatively accurate dynamic information of patient anatomy based on the results were more endurable than 3D CT about motion artifact. From this, it will be useful for dynamic study and respiratory-correlated radiation therapy. This work was supported by the Industrial R&D program of MOTIE/KEIT [10048997, Development of the core technology for integrated therapy devices based on real-time MRI guided tumor tracking] and the Mid-career Researcher Program (2014R1A2A1A10050270) through the National Research Foundation of Korea funded by the Ministry of Science, ICT&Future Planning.

60 APPLIED LIFE SCIENCES↗

SU-F-T-567: Sensitivity and Reproducibility of the Portal Imaging Panel for Routine FFF QC and Patient Plan Dose Measurements

Purpose: The purpose of this work was to see if the EPID is a viable alternative to other QA devices for routine FFF QA and plan dose measurements. Methods: Sensitivity measurements were made to assess response to small changes in field size and beam steering. QA plans were created where field size was varied from baseline values (5–5.5cm, 20–20.5cm). Beam steering was adjusted by altering values in service mode (Symmetry 0–3%). Plans were measured using the Varian portal imager (aS1200 DMI panel), QA3 (Sun Nuclear), and Starcheck Maxi (PTW). FFF beam parameters as stated in Fogliata et al were calculated. Constancy measurements were taken using all 3 QC devices to measure a MLC defined 20×20cm field. Two clinical SABR patient plans were measured on a Varian Edge linac, using the Portal Dosimetry module in ARIA, and results compared with analysis made using Delta4 (ScandiDos). Results: The EPID and the Starcheck performed better at detecting clinically relevant changes in field size with the QA3 performing better when detecting similar changes in beam symmetry. Consistency measurements with the EPID and Starcheck were equivalent, with comparable standard deviations. Clinical plan measurements on the EPID compared well with Delta4 results at 3%/1mm. Conclusion: Our results show that for FFF QA measurements such as field size and symmetry, using the EPID is a viable alternative to other QA devices. The EPID could potentially be used for QC measurements with a focus on geometric accuracy, such as MLC positional QA, due to its high resolution compared to other QA devices (EPID 0.34mm, Starcheck 3mm, QA3 5mm). Good agreement between Delta4 and portal dosimetry also indicated the EPID may be a suitable alternative for measurement of clinical plans.

60 APPLIED LIFE SCIENCES↗

2D Polyhedral Template Matching for Atomic Resolution Microscopy

SAND2024-13879O The 2D Polyhedral Template Matching for Atomic Resolution Microscopy is a suite of functions for analyzing atomic resolution electron microscopy images using the 2D polyhedral template matching (2D-PTM) method. This software analyzes atomic resolution microscopy data from electron microscopic imaging or scanning probe microscopies. The primary application is for identifying different crystal phases, crystal orientations, and defect structures obtained in such atomic resolution images. Written in MATLAB and starting from an atomic resolution image, the code identifies the positions of atomic intensity peaks. It then matches predefined structural templates to the local atomic environments. Outputs include the local structural identification, the template scaling factor and rotation angle, root-mean-squared deviation (RMSD), and centrosymmetry parameter.

Medlin, Douglas↗

Improving the spatial dynamic range of digital inline particle holography

Digital in-line holography (DIH) has been proven to provide three-dimensional droplet position, size, and velocity distributions with a single-camera. This data is crucial for understanding multi-phase flows. In this work, we examine the performance of this diagnostic in the limit of very small particles, on the order of a pixel in diameter and smaller, and propose a post-processing method to improve them: Lanczos interpolation. The Lanczos interpolation kernel is the digital implementation of the Whittaker sinc filter, and strikes a compromise between maintaining the spatial frequency ceiling of the original digital image and computational cost of the interpolation. Without Lanczos interpolation, or super-sampling, the ultimate detectable particle size floor is on the order of 4 pixel widths. We show in this work that this limit can be reduced by 50% or more with super-sampling, depending upon the desired diameter accuracy, and examine the effect of super-sampling on the resulting accuracy of the extracted size and position of spherical particles. Extending this resolution limit increases the overall detection efficiency of the diagnostic. Since this increases the spatial dynamic range of the diagnostic, it can also allow a larger field-of-view to be captured with the same particle size floor.

47 OTHER INSTRUMENTATION↗

Marine Corps Base Camp Lejeune Onslow Bay Seismic Sub-bottom

Critical military training and testing on lands along the nation’s coastal and estuarine shorelines are increasingly placed at risk because of development pressures in surrounding areas, impairments due to other anthropogenic disturbances, and increasing requirements for compliance with environmental regulations. The U.S. Department of Defense (DoD) intends to enhance and sustain its training and testing assets and to optimize its stewardship of natural resources through the development and application of an ecosystem-based management approach on DoD installations. To accomplish this goal, particularly for installations in estuarine/coastal environments, the Strategic Environmental Research and Development Program (SERDP) launched the Defense Coastal/Estuarine Research Program (DCERP) as a minimum 10-year effort at Marine Corps Base Camp Lejeune (MCBCL) in North Carolina. The results of the first six years of the program (DCERP1) are presented here.The overarching objectives of DCERP are to: (1) understand the effects of military training activities, infrastructure development, and other coastal military installations; (2) develop models, tools, and indicators to evaluate ecosystem health; and (3) recommend adaptive management strategies to sustain ecosystem natural resources within the context of an active military installation.This data package includes seismic sub-bottom profile data are from the shallow (-2 to -11.5m, NAVD88) nearshore region of Onslow Beach. Data were collected in 2007 using a high-resolution Edgetech Chirp 512i (average resolution of 10-20cm). The position of each data point was related to NAD83 using RTK-GPS. Data were collected at a frequency range of 0.5-8 kHz. Heave is apparent in the seismic profiles because no swell filter was applied during acquisition or post-processing. Post-processing was performed using Chesapeake Technology SonarWiz MAP5. Georeferenced .sd files (datums: UTM, Zone 18N, meters & NAVD88, meters) were generated using IVS Fledermaus Pro ver. 7.

54 ENVIRONMENTAL SCIENCES↗

GRDC. A Collaborative Framework for Radiological Background and Contextual Data Analysis

The Radiation Mobile Analysis Platform (RadMAP) is unique in its capability to collect both high quality radiological data from both gamma-ray detectors and fast neutron detectors and a broad array of contextual data that includes positioning and stance data, high-resolution 3D radiological data from weather sensors, LiDAR, and visual and hyperspectral cameras. The datasets obtained from RadMAP are both voluminous and complex and require analyses from highly diverse communities within both the national laboratory and academic communities. Maintaining a high level of transparency will enable analysis products to further enrich the RadMAP dataset. It is in this spirit of open and collaborative data that the RadMAP team proposed to collect, calibrate, and make available online data from the RadMAP system. The Berkeley Data Cloud (BDC) is a cloud-based data management framework that enables web-based data browsing visualization, and connects curated datasets to custom workflows such that analysis products can be managed and disseminated while maintaining user access rights. BDC enables cloud-based analyses of large datasets in a manner that simulates real-time data collection, such that BDC can be used to test algorithm performance on real and source-injected datasets. Using the BDC framework, a subset of the RadMAP datasets have been disseminated via the Gamma Ray Data Cloud (GRDC) that is hosted through the National Energy Research Science Computing (NERSC) Center, enabling data access to over 40 users at 10 institutions.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Fast Computational Algorithms for Partial Differential Equations and Uncertainty Quantifications

This project concerned the construction, testing and analysis of computational algorithms for solving parameterized and stochastic partial differential equations. The study and understanding of equations of this type is of fundamental importance in numerous engineering and scientific applications. Examples include simulation of plasma dynamics in models of electric propulsion and nuclear fusion, simulation of multiphase flows, such as the flow of water, gas and oil in reservoirs, and structural analysis of the dependence of structures on materials. Parametrization is used in such settings when properties of the models such as viscosity of fluids or electric resistivity of materials are not precisely understood and instead are treated as random variables. The resulting solutions are themselves random, and having such solutions will enable engineers to use probabilistic methods to assess the likelihood of events, for example, whether a pollutant in a liquid will exceed a limit, and to use such analyses to develop ways to ensure positive outcomes. Construction of accurate (high resolution) computational solutions is expensive, requiring significant computer time and computational resources, and there is need to reduce computational cost to make simulation useful and effective. The aim of the project was to construct algorithms to efficiently compute surrogate solutions to parameterized problems to allow for efficient and accurate simulation. The technical approach used focused on two related strategies, based on rank-reduction methods and reduced-order models. These methods construct surrogate solutions of parameter-dependent models by projection or interpolation into low-dimensional approximation spaces. Cost savings are achieved if the low-dimensional spaces can be identified and constructed efficiently and if the resulting low-dimensional algebraic systems can be solved cheaply. Accomplishments include: Theoretical and empirical demonstration of the effectiveness of fast multigrid solution strategies for computing low-rank representations of parameter-dependent solutions to discrete partial differential equations, including the first proof establishing so-called textbook convergence properties for low-rank methods. Development of efficient solution algorithms for solving nonlinear parameter-dependent partial differential equations used in models of fluid dynamics. Developent of efficient algorithms for low-rank representation of solutions of time-dependent simulations of fluid dynamics using multi-dimensional tensor representations of solutions.

97 MATHEMATICS AND COMPUTING↗

Kinetic-magnetohydrodynamic description of longitudinal sound waves in a collisionless, quasineutral plasma

The time evolution of slow sound waves in a homogeneous, collisionless and quasineutral plasma, in particular their Landau damping, is investigated using the kinetic magnetohydrodynamics formulation of J.J. Ramos (J . Plasma Phys. vol. 81, 2015 p. 905810325; vol. 82, 2016 p. 905820607). In this approach, the electric field is eliminated from a closed, hybrid fluid-kinetic system that ensures automatically the fulfillment of the charge neutrality condition. Considering the time dependence of a spatial-Fourier-mode linear perturbation with wavevector parallel to the equilibrium magnetic field, this can be cast as a second-order self-adjoint problem with a continuum spectrum of real and positive squared frequencies. Therefore, a conventional resolution of the identity with a continuum basis of singular normal modes is guaranteed, which simplifies significantly a Van Kampen-like treatment of the Landau damping. The explicit form of such singular normal modes is obtained, along with their orthogonality relations. These are used to derive the damped time evolution of the fluid moments of solutions of initial-value problems, for the most general kinds of initial conditions. The non-zero parallel electric field is not used explicitly in this analysis, but it is calculated from any given solution after the later has been obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Crystal structure and substrate specificity of the [beta]-ketoacyl-acyl carrier protein synthase III (FabH) from Staphylococcus aureus

{beta}-Ketoacyl-ACP synthase III (FabH), an essential enzyme for bacterial viability, catalyzes the initiation of fatty acid elongation by condensing malonyl-ACP with acetyl-CoA. We have determined the crystal structure of FabH from Staphylococcus aureus, a Gram-positive human pathogen, to 2 {angstrom} resolution. Although the overall structure of S. aureus FabH is similar to that of Escherichia coli FabH, the primer binding pocket in S. aureus FabH is significantly larger than that present in E. coli FabH. The structural differences, which agree with kinetic parameters, provide explanation for the observed varying substrate specificity for E. coli and S. aureus FabH. The rank order of activity of S. aureus FabH with various acyl-CoA primers was as follows: isobutyryl- > hexanoyl- > butyryl- > isovaleryl- >> acetyl-CoA. The availability of crystal structure may aid in designing potent, selective inhibitors of S. aureus FabH.

36 MATERIALS SCIENCE↗

Kinetic instabilities and turbulence in photonic plasma

The purpose of this proposal was to study the statistical dynamics of plasma and demonstrate it experimentally in all-optical systems. That this was possible followed from (1) a direct mapping between the equations of plasma kinetics and the nonlinear propagation of statistical light and (2) advances in photonic technology, which enabled versatile control of the input conditions and direct imaging of the output fields. At the start of the proposal, theory exploiting the optics plasma relationship was minimal, and few experiments had been performed. By the end, the field of photonic plasma had been firmly established. There were two main themes in the proposal. The first was optical confirmation of existing plasma theory, particularly where competing theories or numerical codes needed to be distinguished. The second was the genesis of new research directions for plasma, both fundamentally and for applications. These arose naturally from the proposed projects, as experiment raises different questions than theory, while optics gives a much different perspective than material science. The photonic analogues also provide a unified language for many issues that are difficult (and expensive) to study directly, such as high-energy laser-plasma interactions. Moreover, basic imaging techniques enable measurements that are difficult, if not impossible, in material plasma. For example, Debye shielding hides internal dynamics from outside detectors while nonlinear interactions must often be inferred by deviations from linear expectations. In contrast, optics allows the creation of a wide range of spatial and spectral distributions, along with high-resolution measurements in the full position-momentum phase space.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗