A non-intrusive, ultra-wideband, coaxial diagnostic for measurement of waveform directionality
Brief summary describing PhD project. Intended audience is graduate advisor at Texas Tech University and PhD committee members.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Brief summary describing PhD project. Intended audience is graduate advisor at Texas Tech University and PhD committee members.
Probabilistic Safety Assessment (PSA) is used extensively to evaluate the risks associated with complex engineering systems like Nuclear Power Plants (NPPs). Current PSA models are based on the Event-Tree/Fault-Tree (ET/FT) methodology. ET and FT models are static and are based on Boolean logic approaches. In the past, concerns have been raised in the literature regarding the capability of the traditional static modelling approaches to adequately account for the impact of process, hardware, software, firmware and human interactions on the stochastic system behaviour. To overcome the limitations of the traditional approach to PSA, several dynamic PSA methodologies have been proposed. One of the dynamic PSA methodologies used for dynamic evaluations is Dynamic Event Tree (DET) framework which can be used to assess the impact of the parameter variability and scenario dynamics on the PSA model for the initiating event. The DET framework couples the stochastic model (number of component/trains that start on demand, operator action timing, etc.) with a Thermal-Hydraulic (TH) model of the plant. This paper explores the use of DET along with a case study on advanced reactor. The initiating event selected for the study was Class IV power supply failure event. The TH analysis considering uncertainty in various parameters was performed using RELAP5 and Reactor Analysis and Virtual control ENvironment (RAVEN) tool. Based on the uncertainty analysis, it is concluded that the peak clad temperatures (PCT) are within the limits in all the code runs implying a high-degree of safety margin. However, variation in time to reach the PCT was observed among the code runs and the mean time to reach the PCT was found to be around 8590sec (approximately 2.4 hours). Hence, sufficient time margin is available for human intervention and the operator might have a relatively stress-free state during such an accident scenario. Due to the static nature of the traditional PSA models, the safety margin available was lesser, whereas, with the help of dynamic PSA models, one can demonstrate that the actual available safety margin is more in the present case study and is valuable input from the design point of view.
Modern industrial systems are now fitted with several sensors for condition monitoring. This is advantageous because these sensors can provide mass amounts of data that have the potential for aiding in tasks such as fault detection, diagnosis, and prognostics. However, the information valuable for performing these tasks is often clouded in noise and must be mined from high-dimensional data structures. Therefore, this dissertation presents a data analytics framework for performing these condition monitoring tasks using high-dimensional data. Demonstrations of this framework are detailed for challenges related to power generation systems in automobiles, power plants, and aircraft engines. These implementations leverage data collected from state-of-the-art, industry class test-rigs. Results indicate the ability of this framework to develop effective methodologies for condition monitoring of complex systems.
Electric vehicles (EVs) use electricity as their primary fuel or to improve the efficiency of conventional vehicle designs. EVs include all-electric vehicles, also referred to as battery electric vehicles (BEVs), and plug-in hybrid electric vehicles (PHEVs). In colloquial references, these vehicles are called electric cars, or simply EVs, even though some of these vehicles still use liquid fuels in conjunction with electricity. EVs are known for providing instant torque and a quiet driver experience. Other types of electric-drive vehicles not covered here include hybrid electric vehicles, which are powered by a conventional engine and an electric motor that uses energy stored in a battery that is charged by regenerative braking, not by plugging in, and fuel cell electric vehicles, which use a propulsion system similar to electric vehicles, where energy stored as hydrogen is converted to electricity by the fuel cell.
This document is intended for public release and to be used in an intern senior project. The document explains how yokogawa recorders are programmed in hardware configurator. hardware configurator is used to program the hardware parameters of the recorders.
Electric vehicles (EVs) use electricity as their primary fuel or to improve the efficiency of conventional vehicle designs. EVs include all-electric vehicles, also referred to as battery electric vehicles (BEVs), and plug-in hybrid electric vehicles (PHEVs). In colloquial references, these vehicles are called electric cars, or simply EVs, even though some of these vehicles still use liquid fuels in conjunction with electricity. EVs are known for providing instant torque and a quiet driver experience. Other types of electric-drive vehicles not covered here include hybrid electric vehicles, which are powered by a conventional engine and an electric motor that uses energy stored in a battery that is charged by regenerative braking, not by plugging in, and fuel cell electric vehicles, which use a propulsion system similar to electric vehicles, where energy stored as hydrogen is converted to electricity by the fuel cell. This is the French translation of NREL/FS-5400-87125.
A Documented Safety Analysis (DSA) is a Department of Energy (DOE) construct that defines the extent to which a nuclear facility can be operated safely. It includes a description of hazards, safe boundaries, and hazard controls. The authors assert that a Digital Safety Analysis (DgSA) is far superior to a legacy DSA for several reasons: • The underling database is structured such that it is possible to perform a comprehensive design review and safety analysis by iterating systematically across a hierarchy of linked objects versus a redundant and spotty review by entities of various abilities under unknown resource and schedule constraints. • The analysis of a new design can discover elements that are similar to elements in previous designs. The discovery of similarities is made possible by using the same structure for the underlying database for each new DgSA. The “prior learning” from previous designs is then applied automatically to new designs. • Outputs from the DgSA are from a single source to ensure consistency among various views of the same information. After the DgSA is released, the continued use of a single source implements a configuration management program to ensure consistency between the design basis, the design, the built system, and system procedures. • The development of the DgSA is agile in that any change in a linked object triggers an analysis of impacts on other linked objects and updates of linked objects are made accordingly. After the DgSA is released, the continued maintenance of these links and objects automates the “unreviewed safety question” process.
Explore the source record for details and available documents.
This presentation, Risk-Based, Graded Approach to Insider Threat Mitigation: Human Measures, introduces a structured framework for managing insider threat risk using internationally recognized guidance from the International Atomic Energy Agency (IAEA) Nuclear Security Series No. 8-G (Rev. 1) and the Joint Statement on Mitigating Insider Threats (INFCIRC/908). The presentation emphasizes that effective insider threat mitigation (ITM) depends on both positional controls, which manage inherent risk based on access, authority, and knowledge, and human measures, which address residual risk reflected in behavior, motivation, and reliability. Using a risk-informed and graded approach, the presentation outlines methods for identifying and prioritizing high-risk positions, applying layered organizational controls, and integrating human reliability mechanisms such as the Behavior Observation Program (BOP), Fitness-for-Duty (FFD) evaluations, Employee Assistance Programs (EAP), and Nuclear Security Culture (NSC). The human-focused portion examines behavioral and organizational indicators of opportunity, vulnerability, motivation, and crisis, demonstrating how early detection, deterrence, and response can prevent insider events. The session concludes with a case review of the Millstone Nuclear Power Station incident involving engineer George Galatis. The case illustrates how weak leadership and a poor safety culture can create conditions for failure and how a comprehensive ITM framework could have altered the outcome. The objective of this presentation is to help practitioners apply a risk-based, graded philosophy to human factors and promote a culture of accountability, communication, and resilience within nuclear organizations.
Over the past year, the Qubit Engineering team has pushed the frontiers of power‑grid optimization, working in close collaboration with Oak Ridge National Laboratory (ORNL) and the Tennessee Valley Authority (TVA). Their progress is reflected in three newly submitted conference papers, “Unified Relational GNN Architecture for AC Optimal Power Flow Calculations in Electric Grids,” “Graph‑Based Attention Mechanisms for Solving the AC Optimal Power Flow Problem in Electrical‑Power Networks,” and “Enhanced Power‑Grid Maintenance Planning and Quantum‑Inspired Combinatorial Prospects.” These publications showcase state‑of‑the‑art graph‑neural‑network methods for AC‑OPF and novel quantum‑inspired heuristics for maintenance scheduling. Beyond the academic results, the Qubit team has converted the research into two production‑grade tools built on TVA data: Neuro‑Grid, an AI‑driven power‑flow simulator that provides instant, interactive full‑grid load‑flow visualizations, and Quanta‑Grid, a quantum‑inspired maintenance‑scheduling engine to support logistics optimization for power utilities. Together, these advances demonstrate how Qubit’s partnership with ORNL and TVA is delivering practical, physics‑grounded analytics for next‑generation grid management.
Not Available
Abstract Gasoline compression ignition (GCI) is a cost-effective approach to achieving diesel-like efficiencies with low emissions. The fundamental architecture of the two-stroke Achates Power Opposed-Piston (OP) Engine enables GCI by decoupling piston motion from cylinder scavenging, allowing for flexible and independent control of cylinder residual fraction and temperature leading to improved low-load combustion. In addition, the high peak cylinder pressure and noise challenges at high-load operation are mitigated by the lower brake mean effective pressure (BMEP) operation and faster heat release for the same pressure rise rate of the OP Engine. These advantages further solidify the performance benefits of the OP Engine and demonstrate the near-term feasibility of advanced combustion technologies, enabled by the opposed-piston architecture. This paper presents initial results from steady-state testing on a brand new 2.7-L OP GCI multi-cylinder engine (MCE) designed for light-duty truck applications. Successful GCI operation calls for a high compression ratio (CR), leading to higher combustion stability at low loads, higher efficiencies, and lower cycle HC + NOX emissions. Initial results show a cycle average brake thermal efficiency (BTE) of 31.7%, which is already greater than 11% conventional engines, after only ten weeks of testing. Emissions results suggest that Tier 3 Bin 160 levels can be achieved using a traditional diesel after-treatment system. Combustion noise was well controlled at or below the United States Council for Automotive Research limits. In addition, initial results on catalyst light-off mode with GCI are also presented.
The revised Institute of Electrical and Electronics Engineers (IEEE) 1547-2018, Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces, was published in April 2018. This standard is one of the foundational documents in the United States needed for integrating distributed energy resources (DERs), including solar energy systems, and energy storage systems with the electric distribution grid. The revised standard contains 11 chapters (clauses) and 8 annexes that comprise 136 pages. The revision is significantly different from the 2003 version, and it contains new concepts and new technical requirements. Each clause specifies information or requirements that apply to certain aspects that are important to the interconnection of DERs to the electric power system. Implementing the requirements necessitates a careful study of the underlying technical concepts and requires appropriate information to calculate relevant settings and configurations. This document provides informative material on the requirements related to electrical power quality in IEEE Std 1547-2018, with the intent to equip the reader with basic knowledge and background information to improve understanding and use of the requirements specified.
A vehicle system includes an engine, a transmission, a differential, and a waste heat recovery (WHR) drive that converts thermal energy into mechanical and electrical energy. The WHR drive can include a WHR power unit structured to convert thermal energy into rotation of a WHR drive shaft. A motor/generator having a motor/generator shaft can selectively operate as a motor or a generator. A mechanical linkage is structured to selectively link an output shaft to one of the WHR drive shaft and the motor/generator drive shaft independently of the other of the WHR drive shaft and the motor/generator drive shaft. The output shaft is selectively coupled to one of the engine, the transmission, or the differential. The vehicle system may also include a traction motor to provide drive to the vehicle. The output shaft can be selectively coupled to the traction motor or the engine.
Traditional control theory-based methods require tailored engineering for each system and constant fine-tuning. In power plant control, one often needs to obtain a precise representation of the system dynamics and carefully design the control scheme accordingly. Model-free Reinforcement learning (RL) has emerged as a promising solution for control tasks due to its ability to learn from trial-and-error interactions with the environment. It eliminates the need for explicitly modeling the environment’s dynamics, which is potentially inaccurate. However, the direct imposition of state constraints in power plant control raises challenges for standard RL methods. To address this, we propose a chance-constrained RL algorithm based on Proximal Policy Optimization for supervisory control. Our method employs Lagrangian relaxation to convert the constrained optimization problem into an unconstrained objective, where trainable Lagrange multipliers enforce the state constraints. In conclusion, our approach achieves the smallest distance of violation and violation rate in a load-follow maneuver for an advanced Nuclear Power Plant design.
Renewable water power, including hydropower and marine energy, will play a key role in building a reliable and flexible 100% clean energy future. That future needs a larger, modern workforce - one that's more diverse, equitable, and inclusive - to power and improve these technologies. And researchers at the National Renewable Energy Laboratory (NREL) are committed to fostering tomorrow's water power workforce through science, technology, engineering, and mathematics (STEM) and workforce development programs. Through events, online resources, and more, the lab aims to engage and inspire careers in water power.
This software is an advanced chatbot system that integrates the Model Context Protocol (MCP) to provide intelligent electrical power system analysis and automated visualization generation. The system enables users to interact with complex electrical engineering tools through natural language, automatically analyzes power system data for voltage violations and grid health assessment, and generates professional interactive HTML dashboards and reports. Key features include dynamic tool discovery from MCP servers, multi-LLM provider support, intelligent data interpretation using large language models, automated chart generation, and a web-based interface for real-time analysis. The software bridges sophisticated electrical engineering analysis with user-friendly interfaces, making power system diagnostics accessible through conversational AI.
This report summarizes the design and application of an outdoor power line sensor testbed (OPLST) with a real-time simulator and power meter to compare a potential transformer (PT) and current transformer (CT) versus an advanced line-post sensor. The OPLST was created to validate advanced medium-voltage (20/34.5 kV) outdoor power line sensors used in electrical distribution systems. Electrical utilities have installed metering and relay-protection transformers like PTs and CTs for several decades. The PTs/CTs are iron core measurement transformers based on the electromagnetic induction principle and provide reliable data in normal grid operation. However, new outdoor power line sensors (OPLS) using other technologies like voltage divider, Rogowski coil and optical principles have become available and may have favorable performance and costs compared to PTs/CTs. Therefore, the importance of testing these technologies with the PT/CT, to compare the measured phase voltage/current at different power grid scenarios is crucial to understand the performance of these new OPLS. For this study a G&W Electric Model CVS-36-O power line sensor was chosen as the OPLS to test with voltage/current signals. An OPAL-RT Technologies Model OP4510 real-time simulator and Schweitzer Engineering Laboratories Model SEL-735 power meter were installed with the 20/34.5 kV OPLST to compare the measured transient events collected from an advanced OPLS and the PT/CT. This system is installed at the Distributed Energy Communications and Control (DECC) lab, Oak Ridge National Laboratory (ORNL). The simulator generated different power grid scenarios (electrical faults, capacitor bank operation, service restoration, etc.), and its analog-output signals were connected to the voltage/current amplifiers that feed the 20/34.5 kV aerial cable loop through the PT/CT devices. Additional PT/CT devices were also wired with the medium voltage aerial cable loop to measure the phase current/voltage signals and server as references. After each test, common format for transient data exchange (COMTRADE) files were collected from the SEL-735 power meter and used to compare the performance of the OPLS with the PT/CT. The behavior of analog signals, harmonic components, total harmonic distortion and crest factors were assessed and found favorable for the G&W sensor as compared to the reference PT/CT.