Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pressure drop”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Thermal structure of the atmosphere of Venus from Pioneer Venus radio occultations

The processing and analysis results from 87 radio occultation experiments performed with the Pioneer Venus Orbiter are detailed. Atmospheric structure data were obtained with S-band (2293 MHz) and X-band (8407 MHz) signals transmitted through the 40 and 85 km levels of the Venus atmosphere. Latitudes of -68 to 88 deg at solar zenith angles of 8-166 deg were explored. The conversion of the data into acceptable form for the barometric equation to use the perfect gas law to obtain the temperature profiles is described. The temperature structures were more dependent on latitude than solar illumination conditions, with the greatest changes occurring in the circumpolar region. The polar tropopause altitude was about 4.8 km above its value at lower altitudes, with a temperature drop of 60 K and a pressure drop of 240 mb.

Kliore, A. J.↗

History of water on Mars - A biological perspective

A general scenario is developed for the history of liquid water on the surface of Mars, according to which the history of water on Mars can be divided into four epochs based on the fundamental temperature and pressure characteristics. In Epoch I, the mean annual temperature is assumed to have been above freezing and the pressure to have been above 1 atm; liquid water was widespread and life could have arisen and become abundant. In Epoch II, the mean annual temperature fell below freezing, but peak temperatures were above freezing; In Epoch II ice-covered lakes could have provided a habitat for life. In Epoch III, both the mean and the peak temperatures were below freezing, and only transient liquid water would be possible; under these conditions, microbial ecosystems living in endolithic rock 'greenhouses' could have continued to survive. Finally, in Epoch IV, the pressure dropped to near the triple point pressure of water; at this stage, life on the surface of Mars would have become extinct.

Mckay, Christopher P.↗

Shear coaxial injector instability mechanisms

Although stable operating regimes for cryogenic coaxial injectors have been empirically determined, there is no knowledge of the spray characteristics corresponding to stable operation, or the physical processes which produce the atomization patterns that result in stable or unstable operation. The current engineering method for determining the stable operating regime of a cryogenic coaxial injector is the 'hydrogen temperature ramping' method, however there is no definitive knowledge of whether the hydrogen temperature influences the chamber stability by decreasing the injected gas velocity, by affecting a recirculation region at the base of the LOX Post, or by changing the pressure drop across the injector, allowing chamber pressure oscillations to couple to the fuel feed system. Results for the injector response from a linearized lumped-element model are presented as a function of temperature and frequency. LDV measurements in the recess region at the base of the LOX post show reverse flow indicative of a recirculation region. Finally, Phase Doppler Particle Analyzer (PDPA) measurements of droplet size and velocity distributions are discussed for a coaxial injector element similar to the SSME preburner element operating with water and air at atmospheric pressure and liquid and gaseous nitrogen at 20 bars.

Kaltz, T.↗

Flow rate/pressure drop data gathered from testing a sample of the Space Shuttle Strain Isolation Pad (SIP): Effects of ambient pressure combined with tension and compression conditions

Tests were conducted on a sample of strain isolation pad (SIP) typical of that used in the shuttle orbiter thermal protection system to determine the characteristics of SIP internal flow. Data obtained were pressure drop as a function of flow rate for a range of ambient pressures representing various points along the Shuttle trajectory and for stretched and compressed conditions of the SIP. Flow was in the direction of the weave parallel to most of the fibers. The data are plotted in several standard engineering formats in order to be of maximum utility to the user. In addition to providing support to the Space Shuttle Program, these data are a source of experimental information on flow through fiberous (rather than the more usual sand bed type) porous media.

Springfield, R. D.↗

Two-Phase Flow in Filters and Orifices: In preparation for Measurements on ISS Packed Bed Reactor Experiment-Water Recovery Series (PBRE-WRS)

Understanding the hydrodynamics of adiabatic two-phase flows in packed bed reactors offers numerous benefits. It enables the optimization of chemical reactions rates and products, crucial for pharmaceuticals and energy production industries. Additionally, this understanding aids in designing more efficient and compact reactors, reducing space and resource requirements. Insights gained from studying such flows in microgravity contribute to advancements of space technologies and the enhancement of our capabilities for undertaking future long duration safe, and sustainable space exploration missions. The Packed Bed Reactor Experiment-Water Recovery Series (PBRE-WRS) is a flight experiment planned for operation on the Microgravity Science Glove box (MSG) facility of the International Space Station (ISS). The objective of the experiment is to validate hydrodynamic models at a range of gas and liquid flow rates. The microgravity environment allows for measurement and observation of aspects of fluid dynamics that are unique when compared to observations made in full or partial gravity environments. The experiment consists of testing two-phase flow hydrodynamics in three different filters, four (4) orifices and one check valve test articles. The experiment utilizes the hardware of the previously flown PBRE and PBRE-2 with packed beds of different packings materials and sizes. The fluid system of the PBRE-WRS consists of a nitrogen gas delivery and water delivery subsystems. The gas delivery subsystem can accommodate two ranges of gas flow rates, just as for the water delivery system. The nitrogen gas loop is open whereas the water loop is closed. Gas is separated from the water using a gas-liquid phase separator which is located in the water delivery module. Preliminary results from ground testing show the pressure drop increasing at different rates with the liquid and gas flow rates in the Brine filter. In this work, a detailed system description is presented along with a summary of results from ground performance testing of different test sections in an end-to-end preflight testing campaign.

Packed Bed Reactor Experiment↗

Voxel Based Three-Dimensional Topology Optimization of Heat Exchanger Fins

Increasing interest in novel aircraft propulsion systems and potential for unwanted heat generation, or capture and reuse of waste heat, may require increasingly lightweight and high performing heat exchangers. Advances in manufacturing technologies have shown potential to create complex designs, but design tools need more flexibility. This study utilizes genetic algorithm-driven topology optimization to develop high performance heat exchanger fins for critical applications such as aerospace. The solid domain is generated using voxel representation where a voxel value of 1 indicates the solid domain and a voxel value of 0 refers to the fluid domain. The use of voxel representation somewhat matches the digitization of a model that is required to fabricate using additive manufacturing, and also allows for a highly unconstrained geometry. To test the topology optimization approach, a three-dimensional(3D)baseline offset strip fin geometry in steady laminar flow(Reynolds number = 215)with conjugate heat transfer(simultaneous solution of solid and fluid temperature fields)is optimized. New designs are generated using the genetic algorithm (GA) and sent to evaluation by the CFD software OpenFOAM; then the GA sorts and selects the reproduction pool for the following generation. This process is repeated for 60 generations. The study also investigates the effect off in material on the performance of the GA and the resulting designs. The results show that the optimal designs have overall performance improvement of 18% relative to the baseline. Additionally, a fin constructed of a lower conductivity material (such as an Inconel super alloy that might be necessary for waste heat recovery applications)results in lower overall performance improvement (11%)and optimal designs with higher pressure drop relative to their baseline, and relative to optimal designs produced using higher conductivity materials.

3D Optimization↗