At least 469 records · Page 26

Cost and Performance Baseline for Fossil Energy Plants Supplement: Sensitivity to CO 2 Capture Rate in Coal-Fired Power Plants

The cost and performance of various plants designed to meet a range of carbon dioxide (CO 2 ) emissions are evaluated in this report by varying the CO 2 capture rate. The base cases for these designs are the supercritical (SC) pulverized coal (PC) plant from the National Energy Technology Laboratory’s (NETL) report “Cost and Performance Baseline for Fossil Energy Plants, Volume 1a: Bituminous Coal (PC) and Natural Gas to Electricity, Revision 3” and the General Electric Energy (GEE) integrated gasification combined cycle (IGCC) plant in NETL’s report, “Cost and Performance Baseline for Fossil Energy Plants, Volume 1b: Bituminous Coal (IGCC) to Electricity, Revision 2 – Year Dollar Update.” The chosen SC PC plants were based on the Case B12B, differing only in the addition of a bypass flow path that allows for an appropriate portion of the flue gas stream exiting the desulfurization step to be directed towards the stack, which reduces the amount CO 2 captured in the Cansolv process. The chosen IGCC plants were based on the Case B5B, differing by bypassing (either partially or entirely) the water gas shift reactors and thereby reducing the amount of CO 2 captured in the Selexol process. The major components of the underlying CO 2 capture technology in the plants were preserved with minimal modifications to the overall processes. The SC PC cases include up-to-date cost and performance information from recent vendor quotes whereas the IGCC performance and cost are based upon the older quotes used for the Revision 2 report, with standard adjustments made to update the costs to 2011 dollars.

01 COAL, LIGNITE, AND PEAT↗

Pilot Scale Operation and Testing of Syngas Chemical Looping For Hydrogen Production

The Syngas Chemical looping (SCL) process provides efficient and economic means to utilize the abundant fossil reserve of coal. The main problem associated with coal utilization is the CO 2 emissions resulting from its combustion. Even though CO 2 regulation or carbon tax is currently not in place, its enforcement is expected in the near future. Such a greenhouse gas emission control, if adopted in current power plant systems, will drive the efficiency down and increase the cost of electricity, due to the energy and capital-intensive nature of current CO 2 separation techniques. This highlights the need to develop technologies that present a solution to the rising cost of electricity in the future. The integrated gasification combined cycle (IGCC) presents an improvement to the above predicament, but it is capital intensive due to the extensive unit operations involved. The efficiency for a CO 2 capture incorporated IGCC system is around ~32%, resulting in approximately 45% increase in cost of electricity. This is definitely a better path to traverse than the conventional pulverized coal (PC) power plants as it has improved economics and efficiencies accompanied by product flexibility. The SCL process advances the benefits even further when integrated with the IGCC process. The SCL process removes the expensive WGS system and CO 2 separation columns, thereby saving on capital and operational expenses. This integration results in a 12 – 21% increase in efficiency accompanied by a reduction in cost of electricity by 15 – 28%, over conventional IGCC systems. Therefore, SCL process provides the best route to harness the energy from coal. The overall project objective was to construct and operate a syngas chemical looping pilot scale test unit at the NCCC. The project scope of work was divided into 3 phases. In Phase I, cold flow model studies using a 1:1 scale acrylic test unit constructed at Particulate Solids Research, Inc. (PSRI) was successfully completed confirming robust solid flow control is achievable in the non-mechanical system design. In Phase II, the high pressure, high temperature, chemical looping reactor was successfully designed with all necessary equipment and safety instrumentation/controls specified to allow for fabrication, site construction, and assembly to commence in Phase III. In Phase III, the SCL pilot plant was successfully assembled and all necessary functional checks and pre-startup safety reviews completed. During unit commission over the course of 200 hours of testing, operational issues were observed with premix burner used for system startup. With the grants awarded by the National Energy Laboratory (NETL) and the Ohio Development Services Agency (ODSA) under awards DE-FE0023915 and D-14-18, the SCL pilot unit underwent three auxiliary equipment modifications to resolve all of the startup operational issues encountered. The unit was successfully demonstrated with 300+hr continuous operation. Key results obtained include high syngas conversion of 97.95% with 16.03% oxygen carrier conversion in the moving bed reducer and >99% purity H 2 produced from the moving bed oxidizer.

01 COAL, LIGNITE, AND PEAT↗

Improving Coal Power Economics: Retrofitting Flameless Pressurized Oxy-Combustion with Integral CO2 Capture

Presentation discussing Flameless Pressurized Oxy-combustion (FPO) technology's: philosophy and performance vs. traditional combustion, added value, and development path. Also overviewed is the large pilot planning with an update on DOE Project DE-FE0031580, cycle diagram, and plan for commercial-scale cycle. A summary of the projected cost of electricity for FPO with carbon capture, comparing to pulverized coal technology. New-build and retrofit FPO with PRB coal is compared. FPO new-build retrofit potential outlook for commercialization is addressed.

Reineck, Peter↗

Conversion of Coal Wastes and Coal Plus Other Opportunity Fuel Mixtures, Such as Coal Plus Municipal Solids, to Produce Electricity and/or Liquid Fuels

For the foreseeable future, the Nation’s energy demand will continue to come largely from indigenous fossil energy resources and hydrocarbon fuels. Specifically waste coal plus other opportunity fuels need to be utilized as a feedstock to eliminate a waste stream and optimized to maximize energy yield and cleanly minimize pollutant emissions. Modular equipment is needed for installation in coal preparation locations, military installations, and research park facilities. Thermal decomposition of coal, biomass, and mixed solid waste (MSW) have been shown to reduce a waste stream while providing liquid and gaseous fuel products with low pollutant emissions. However, thermal decomposition processes have several challenges associated with preprocessing biomass and MSW, feeding and conveying material into the reactor, and post processing of syngas to remove undesirable products while upgrading to increase yield of high value products. Increasing total energy output from power plants by utilizing biomass and mixed wastes ultimately lowers energy costs, harmful environmental impacts of emissions, and has significant impacts on the energy security and sustainability of the U.S. economy. Entrained flow gasifiers (EFGs) produce very little CH4 and a wide range of H2/CO ratios (0.5–2.0) but are limited in their ability to effectively feed large biomass or MSW particles into the reactor. A solution to the feeding problems is to use pyrolysis torrefaction (PT) for conversion of waste materials to create a feedstock similar to coal and capable of grinding down and mixing with the coal feed. Mainstream experimentally explored reaction pathways for the conversion of coal waste plus municipal solids (CWPMS) and demonstrated a bench-scale reactor used for torrefaction of the municipal solid waste (MSW) to create a coal-like feed for blending with the coal waste. The material was processed in a pilot-scale EFG to determine product yield and emissions with CWPMS fuels, as well as the ash content and slagging properties of these feedstocks. The PT-EFG system was experimentally validated, where emissions and yield data were used to develop a high-fidelity process model and economic analysis. The following was accomplished in the Phase I: Determined optimal torrefaction process conditions for MSW and biomass through TGA; maximized heating value of fuel while maximizing final mass of torrefied product Demonstrated torrefaction of MSW and biomass feedstocks at 334°C, pulverized to uniform 74 µm particle size, and processed into coal-like feedstocks Demonstrated 8 lb/h pilot-scale EFG using MSW and biomass blends with waste coal; demonstrated 100% biomass in EFG Determined major effects of MSW torrefaction and co-gasifying high-ash coal waste-MSW blends have on pilot-scale EFG Demonstrated blending low-ash, low-sulfur torrefied biomass with high-ash waste bituminous and anthracite refuse coals generates a higher quality syngas compared to syngas from high-ash waste coals Demonstrated a high carbon conversion (> 99.5%) and syngas with 29.47% H2 content, and 0% CH4 content; greater water–gas shift occurs in EFG than predicted by equilibrium ASPEN Plus model Blended lower-ash, high-alkali biomass MSW to lower slag viscosities of the high-ash coal refuse sufficiently for better slag flow compared to feeding the high-ash coal Used low-sulfur biomass to greatly reduce the EFG syngas H2S concentrations and produce non-leachable slag and quench water with very little organic and trace metal contamination Developed a process model and TEA showing the modular PT EFG is cost competitive to existing power plants with the advantage of using low- or negative-value feedstocks such as waste coal stockpiles and non-landfilled MSW; providing a large incentive to implement an economical PT-EFG process

30 DIRECT ENERGY CONVERSION↗

Biomass Torrefaction for Coal-Biomass Cofiring

This unit process considers the mass/energy inputs, mass outputs, and air emissions for the torrefaction of biomass, which is the partial gasification of biomass (without oxygen), to enable cofiring at a pulverized coal power plant. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=178A2769-00F1-4D21-82FF-4D86F6BDA56C

09 BIOMASS FUELS↗

EXPC Plant CCS Retrofit, Construction

Material inputs for retrofitting an existing pulverized coal (EXPC) power plant with carbon capture and sequestration (CCS). To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=03FD6C0E-5DA6-4455-9374-78A247D946BB

01 COAL, LIGNITE, AND PEAT↗

Operation of NETL Baseline SCPC Power Plant

The operations of the NETL baseline Supercritical Pulverized Coal (SCPC) power plants with or without carbon capture and sequestration (CCS) on the basis of 1 MWh electricity output. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=B5A2EB6F-4FBC-4883-922C-BE720FAC5A80

01 COAL, LIGNITE, AND PEAT↗

Operation of NETL Baseline SubCPC Power Plant

The operations of the NETL baseline Subcritical Pulverized Coal (SubCPC) power plants with or without carbon capture and sequestration (CCS) on the basis of 1 MWh electricity output. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=726C064C-F978-49EB-931C-5F69AD92BD5C

01 COAL, LIGNITE, AND PEAT↗

SCPC Power Plant, Construction

Material input for the construction of the NETL baseline supercritical pulverized coal (SCPC) plant with or without carbon capture and sequestration (CCS). To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=404A3685-9CEF-4095-91EB-44CCF08D24F4

01 COAL, LIGNITE, AND PEAT↗

Combined Sorbent/WGS-based CO 2 Capture Process with Integrated Heat Management for IGCC Systems

Southern Research has developed a combined CO 2 capture water-gas shift (WGS) process for integrated gasification combined cycle (IGCC) applications. A highly efficient regenerable magnesium based sorbent was prepared to remove CO 2 . It offers high and stable CO 2 capacity with minimum requirement for temperature and pressure swings. Under optimized conditions, the sorbents achieved up to 8 mmol/g of CO 2 working capacity and remained stable over 500 cycles of adsorption and regeneration. The selected WGS process achieved 96% CO per pass conversion and remained isothermal during the test duration that lasted over 500 cycles. The approach showed potential to reduce cost of electricity (COE) compared to the baseline carbon capture approaches. The process is for bench-scale and pilot development. In a commercial embodiment, syngas from the gasifier is cooled to warm gas conditions. It then enters the CO 2 sorbent-shift reactor that uses an efficient MgO-based CO 2 sorbent and a commercial catalyst to shift the CO to CO 2 and capture 90% + of the carbon. Using a dual-bed arrangement, the sorbent is regenerated periodically by a combination of pressure and temperature swing to maintain steady state conditions and produce a 95+ % CO 2 stream for sequestration. The hydrogen rich syngas is sent to the IGCC for power production. In addition to consolidating CO 2 capture with WGS, the proposed process reduces parasitic energy losses by operating at warm gas temperatures and reduces parasitic plant load (i.e., steam and auxiliary power) by reducing energy required for regeneration. The project consisted of 3 budget periods (BP) of laboratory-scale research and testing with go/no-go decisions after BP-1 and BP-2. In the 12 month BP-1, it was shown show that one promising sorbent maintained the required CO 2 capacity and durability of >1.5 mmol/g over 100 cycles. Also based on sorbent and WGS experiments in separate reactors and combined reactor modeling, it was shown that the process had the potential to capture 90% of the CO 2 at a lower than conventional amine-based approach. In the 18 month BP-2, a lab scale combined sorbent/WGS reactor system was built, commissioned, and tested with the promising sorbent from BP-1. 90% carbon capture was demonstrated over 100 cycles and it was shown that the process continued to have potential to capture 90% of the carbon at a cost that was less than the conventional amine-based approach. In the 6 month BP-3, a long term test was conducted using the best SR sorbent. The required durability of > 2 mmol/g was demonstrated after 500 cycles. Also, 90% carbon capture and 96% CO conversion was maintained over 1000 cycles. A technical and economic feasibility study was carried out to compare the proposed pre-combustion approach to a gasification plant employing a conventional pre-combustion approach and a conventional pulverized caol (PC) plant employing a conventional post combustion CO 2 capture approach.

01 COAL, LIGNITE, AND PEAT↗

Eliminating the Derate of Carbon Capture Retrofits

One of the more significant issues related to carbon capture retrofits pertains to the reduction in net power output (derate) due to the large parasitic power load required for appreciable levels of carbon capture. Post-combustion capture (PCC) has been shown to reduce the net plant efficiency of an equivalent plant without capture by 20 percent or more. Yet, post-combustion amine scrubbing is anticipated to be the most viable near-term technology for reducing carbon dioxide (CO 2 ) emissions from existing coal plants. This study attempts to quantify auxiliary load replacement options for existing pulverized coal (PC) boilers to reduce the effects caused by steam and power requirements of the CCS systems and the resulting derated output of the existing plant. While individual retrofit options are highly plant-specific and, therefore, subject to unique optimization pathways, each of the proposed cases in this study attempts to examine the most promising configurations for each repowering technology.

Chou, Vincent↗

Techno-Economic Analysis of CO 2 Capture-Ready Coal-Fired Power Plants

This analysis evaluates CO 2 capture-ready supercritical pulverized coal units. Cost and performance results are presented for capture-ready coal units that achieve a 30-year average emission rate of 1,000 Lb CO 2 /MWh. The analysis also includes a detailed discussion of the specific elements that comprise a capture-ready unit, as well as different design strategies to minimize costs. The benefits of R&D advances such as 2nd generation CO 2 capture, and additional revenue from CO 2 sales for enhanced oil recovery, are also presented, and are compared to other baseload generation options, such as natural gas combined cycle and nuclear.

01 COAL, LIGNITE, AND PEAT↗

Cost and Performance Baseline for Fossil Energy Plants - Volume 3b: Low Rank Coal to Electricity: Combustion Cases

The Cost and Performance Baseline for Fossil Energy Power Plants Study, Volume 3b: Low Rank Coal to Electricity establishes performance and cost data for fossil energy power systems, specifically pulverized coal (PC) and circulating fluidized bed combustor (CFBC) plants all with and without carbon capture and sequestration. The analyses were performed on a consistent technical and economic basis that accurately reflects current market conditions. The study serves as a benchmark to track the progress of DOE Advanced Power Systems R&D and as a baseline for analyzing fossil energy plant options.

01 COAL, LIGNITE, AND PEAT↗

Cost and Performance Baseline for Fossil Energy Plants - Volume 3c: Natural Gas Combined Cycle at Elevation

The Cost and Performance Baseline for Fossil Energy Power Plants Study, Volume 3b: Low Rank Coal to Electricity establishes performance and cost data for fossil energy power systems, specifically pulverized coal (PC) and circulating fluidized bed combustor (CFBC) plants all with and without carbon capture and sequestration. The analyses were performed on a consistent technical and economic basis that accurately reflects current market conditions. The study serves as a benchmark to track the progress of DOE Advanced Power Systems R&D and as a baseline for analyzing fossil energy plant options.

03 NATURAL GAS↗

Cost and Performance Baseline for Fossil Energy Plants, Volume 1: Bituminous Coal and Natural Gas to Electricity, Revision 2a

Objective is to establish baseline performance and cost estimates for today’s fossil energy plants, it is necessary to look at the current state of technology. Such a baseline can be used to benchmark the progress of the Fossil Energy RD&D portfolio. This study provides an accurate, independent assessment of the cost and performance for Pulverized Coal (PC) Combustion, Integrated Gasification Combined Cycles (IGCC), and Natural Gas Combined Cycles (NGCC), all with and without carbon dioxide (CO 2 ) capture and sequestration assuming that the plants use technology available today.

20 FOSSIL-FUELED POWER PLANTS↗

Cost and Performance of PC and IGCC Plants for a Range of Carbon Dioxide Capture - Rev. 1

The objective of this study was to establish the cost and performance for a range of carbon dioxide (CO 2 ) capture levels for new supercritical (SC) pulverized coal (PC) and integrated gasification combined cycle (IGCC) power plants. The SC PC cases (Case 1 series) utilize Fluor’s Econamine FG Plus SM process for post-combustion CO 2 capture via temperature swing absorption with a 30 wt% monoethanolamine (MEA) solution as the chemical solvent. The IGCC cases (Case 2 series) employ a slurry-fed, entrained-flow General Electric Energy (GEE) gasifier and leverage UOP’s (formerly Universal Oil Products) two-stage Selexol™ process for bulk CO 2 capture and selective hydrogen sulfide (H 2 S) removal via pressure swing absorption. The Selexol™ process uses dimethyl ether of polyethylene glycol (DEPG) as a physical solvent for pre-combustion capture.

01 COAL, LIGNITE, AND PEAT↗

Enabling Staged Pressurized Oxy-Combustion: Improving Flexibility and Performance at Reduced Cost

Introduction: The staged pressurized oxy-combustion (SPOC) process, developed by Washington University in St. Louis (WUSTL), is an oxy-combustion carbon capture technology that employs a steam power cycle to generate electricity. As with atmospheric-pressure oxy-combustion processes, carbon dioxide (CO 2 ) capture rates of 90% or higher can be achieved. The staged-combustion approach of the SPOC process, when operated at elevated gas pressure, allows for near elimination of flue gas recycle (FGR) and leads to significant improvements in efficiency and reduced costs. The primary goal of this project was to investigate the potential for SPOC for flexible operation beyond the capabilities of conventional coal-fired power plants, particularly those employing carbon capture and storage (CCS). Oxy-combustion differs from conventional coal combustion in that the combustion of coal is carried out using oxygen as opposed to air. The resultant flue gas is a mixture of primarily CO 2 and water, greatly simplifying CO 2 capture. As SPOC does the oxy-combustion process under pressure, it is higher efficiency and lower cost than atmospheric oxy-combustion. The project was led by the Electric Power Research Institute, Inc., with the assistance of WUSTL, Doosan Babcock (DBL – boiler plant original equipment manufacturer), and Air Liquide (AL – air separation experts). The specific objectives of the project were to: (1) Evaluate the SPOC concept and develop a risk-based approach to the heating surface layout ensuring that performance (gas and steam side), manufacturing, transportation, and plant erection considerations were fully accounted for in the system design. (2) Improve the technology to ensure its performance and cost potential are substantially better than today’s baseline pulverized coal power plant with post-combustion capture (PCC) or atmospheric oxy-combustion, and show progress toward performance commensurate with projected commercial operation, including 90% or more CO 2 capture. (3) Address critical technology gaps and improving overall system performance for the technology. (4) Perform combustion tests at scale under commensurate pressure to the commercial operating system validate combustor and advance the SPOC combustion modeling tools that will facilitate full-scale design. Combustion Testing: Testing was initially carried out at atmospheric pressure with methane to ensure that all systems were correctly operating. Following this, the testing then proceeded to moderate pressure operation at 4 bara, where different stoichiometric conditions were used across an extended heat input range, showing that a stable flame could be maintained. Testing then proceeded at 10 and 15 bara where it was shown that the ignition system needed to be replaced at these operating conditions. When testing recommenced, a similar stable flame shape was achieved, without any methane support, and the full 100 kWth coal oxy-combustion was demonstrated. Heat flux measurements showed 400 kW/m 2 (0.126 MMBtu/hr-ft 2 ) from the flame, within the 450 kW/m 2 (0.142 MMBtu/hr-ft 2 ) preferred limit defined by DBL for the full-scale design case. Carbon monoxide and carbon-in-ash measurements showed that complete combustion was possible with ultra-low excess oxygen at 1 vol % in the product flue gas. This allowed the full-scale models to be calculated based on this level of excess oxygen, improving the performance of the system as lower feed oxygen is produced in the air separation unit (ASU), saving auxiliary power. Full-Scale Design: The full-scale design is sized to deliver 550 MWe net electrical power output to allow direct comparison with the National Energy Technology Laboratory (NETL) baseline cases using the same Montana Powder River Basin (PRB) fuel. The cases used for direct comparison are: Case S12A (supercritical [SC] coal without CO 2 capture), Case S12B (SC coal with PCC at 90% CO 2 capture, and Case S12F (atmospheric oxy-combustion SC coal with 90% CO 2 capture). The SPOC stages were configured to be identical arrangements, allowing for a more straightforward design, construction, and control strategy. Each stage consists of two PVs, the first being the combustor PV module and the second being the convective PV module. The combustor module is the tallest vessel, with local coal feeding equipment and the burner FGR and oxygen plenums at the top and ash management at the bottom. The combustor module is effectively an open cross section with membrane tubes around the circumference – this unobstructed slender profile ensures that the relatively slower burnout mechanism needed for the low-speed turbulent mixing burner can proceed unimpeded and that molten ash will not attach to any surfaces at an angle to the predominant flue gas flow. The steam turbine used in the SPOC design is essentially the same unit utilized in the atmospheric oxy-combustion case except the degree of heat recovery possible allows the low-pressure (LP) feedwater heater train to be eliminated. This is a result of being able to capture the latent heat of evaporation of the moisture produced in the combustion (normally lost to the stack). The SPOC system outperforms the NETL atmospheric oxy-combustion baseline case by 3.3% points and the PCC case by 7.5% points. This performance increase is mainly a result of the improved heat recovery possible from the product flue gas and from the reduced auxiliary power consumption from the ASU and the CO 2 compression and purification unit over the atmospheric equivalent. The combined improvement in boiler efficiency and reduction in the steam turbine heat rate resulted in a net improvement in the overall plant efficiency by 0.61%, to 35.6% on a HHV basis. This relatively small improvement in plant efficiency between sub-bituminous and bituminous coals shows the value of useful moisture latent heat recovery offered by the SPOC system when using low rank fuels. Flexibility and Turndown: The SPOC system has inherent high turndown capabilities because of a demonstrated high range of combustion stability and the ability to bypass stages, thereby reducing steam generation rates proportionally without altering firing rates in operating stages. ASU units do not generally offer significant turndown opportunities as they are limited by the performance of the compression plant. The baseline SPOC design has a 2-train ASU configuration, needed to be able to meet the 10,500 tonnes per day duty, that can deliver efficient turndown points between 85–100% load with both trains operating, and at 45–50% load with a single train operating. Outside these operating points, the flexibility and efficiency are limited and may be uncompetitive at loads below 45% as the ASU systems are unable to turndown beyond 85% for the base case and 70% for the flexible case. The ASU cold box for the flexible case was designed to operate at loads between 40-100%, below this operating range the purity of the produced oxygen cannot be guaranteed, resulting in additional load for the CPU equipment. The additional power consumption of these cases yields an uneconomic operating condition with poor efficiency when operating at low loads such as 25% and 12%. To address this flexibility constraint, AL evaluated how the ASU configuration could be altered to deliver efficient oxygen supply over the load range. This involved integrating the compressor duties across both ASU trains into a shared duty arrangement with multiple compressors, strategically sized to deliver the duty required across all load ranges between 40–100% by enabling different combinations of the main air compressors and the booster air compressors. The oxygen purity cannot be guaranteed below 40% load for each train – the power consumption at 25% and 12% loads were estimated based on the multi-compressor configuration at maximum turndown as these load cases were not considered in the flexible ASU design. With a different cold box configuration, i.e. number of trains, the entire load range could be delivered within oxygen purity specifications. Although there is a small efficiency reduction at full load, there are significant improvements in overall plant performance during low-load operation. The exact ASU configuration needed will therefore be dependent on the expected operating profile of the unit. Economic Analysis: Cost estimates for the baseline and the flexible cases were developed using NETL baseline case data for common BOP items and an Association for the Advancement of Cost Engineering International Class 5 (conceptual/screening study) assessment of key components unique to the SPOC system. The capital, operating, and maintenance costs were assessed along with the first-year power cost, levelized cost of electricity, and CO 2 captured and avoided cost for the SPOC cases were compared against the relevant NETL baseline cases in January 2019 dollars. Both SPOC cases achieve a lower cost that the alternative NETL baseline cases (with the flexible SPOC case being slightly higher than the baseline SPOC case due to the compounded impact of higher capital costs and lower efficiency at full load). The SPOC cases deliver a lower cost of CO 2 avoided than the NETL baseline cases due to greater efficiency in generating low-carbon power. However, the cost of CO 2 captured is higher because the higher efficiency of the SPOC process generates less CO 2 , hence less needs to be captured, resulting in a high capital cost being shared over a reduced CO 2 quantity. The flexible ASU adds 1.6% overall to the plant cost in comparison to the baseline case, but the efficiency improvements at loads below 50% are significant. Subsequently, depending on the plant load-profile expectation, the flexible ASU would be beneficial if the plant spends a significant portion of its operating life below 50% load. This kind of operating profile is likely to be required for all fossil plants when more renewable electricity generators are installed on the local grid, particularly solar power that can be predicted ahead of time, allowing for appropriate pricing signals to be incorporated into the diurnal cycle. R&D Recommendations: SPOC, while a promising technology, is a relatively recent concept and, as such, operability issues of combustor design and steam-side integration for such systems at a scale relevant to commercial deployment have not been evaluated. WUSTL has conducted extensive small pilot-scale (100 kWth) research to understand and advance pressurized oxy-combustion processes, including investigation of combustion and flame characteristics, radiative heat flux, burner operability, turn down, char burnout, ash characteristics, water-wash column operation, etc. for pressurized oxy-combustion systems. Nonetheless, at this stage in the development of the SPOC process, what is needed is a large-scale pilot plant that can serve to study pressurized oxy-combustion systems and components at a scale commensurate with the maturity of the technology. A scale of 10 MWth, which includes steam-side integration and two stages would yield essential information with respect to heat transfer characteristics both in the radiative and convective sections of the pressure vessels, and the ability to operate the fuel staging process. In addition, while modeling results indicate that combustion and flame characteristics improve with scale, direct studies of the combustor at this scale will ensure that the models can be relied upon for scale up to commercial scale. Furthermore, a detailed analysis must be performed to understand the scaling aspects of key components and systems.

20 FOSSIL-FUELED POWER PLANTS↗