Search NASA⌕ Search

SEARCH · Search NASA

Results for “Qualification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

CID-720 aircraft Langley Research Center preflight hardware tests: Development, flight acceptance and qualification

The testing conducted on LaRC-developed hardware for the controlled impact demonstration transport aircraft is discussed. To properly develop flight qualified crash systems, two environments were considered: the aircraft flight environment with the focus on vibration and temperature effects, and the crash environment with the long pulse shock effects. Also with the large quantity of fuel in the wing tanks the possibility of fire was considered to be a threat to data retrieval and thus fire tests were included in the development test process. The aircraft test successfully demonstrated the performance of the LaRC developed heat shields. Good telemetered data (S-band) was received during the impact and slide-out phase, and even after the aircraft came to rest. The two onboard DAS tape recorders were protected from the intense fire and high quality tape data was recovered. The complete photographic system performed as planned throughout the 40.0 sec of film supply. The four photo power distribution pallets remained in good condition and all ten onboard 16 mm high speed (400 frames/sec) cameras produced good film data.

Pride, J. D.↗

Development of design criteria and qualification tests for bypass diodes in photovoltaic applications

Design criteria have been developed for bypass diodes in p-n and Schottky barrier in photovoltaic applications. A test method for assessing conformity to the design criteria is described. Junction temperatures are defined in terms of expected worst-case field conditions, including ambient temperature and solar irradiance on the photovoltaic module. The rating criteria address the maximum allowable current and heat-sink characteristics of diodes mounted inside or outside the photovoltaic module. The method establishes worst-case module-to-diode thermal interfaces and may be adapted for laboratory or field-site experiments. A list of the design criteria is given.

Otth, D. H.↗

Qualification Testing of General Electric 50 Ah Nickel-Cadmium Cells with New Separator and New Positive Plate Processing

Forty-two 50 Ah aerospace nickel-cadmium cells were delivered to Goddard Space Flight Center (GSFC) by General Electric (GE) in February, 1985, for the purpose of evaluating and qualifying a new nylon separator material Pellon 2536, and the new GE Positive Plate Nickel Attack Control Passivation process. Testing began in May, 1985, at the Naval Weapons Support Center (NWSC) in Crane, Indiana with standard initial evaluation tests. Life cycling in both Low Earth Orbit (LEO) and Geosynchronous Orbit (GEO) began in July, 1985, with approximately 1200 LEO cycles complete at this writting. Early test results show that cells with positive plate passivation exhibit higher than normal charge voltage characteristics. Other aspects of performance were nominal.

Morrow, G. W.↗

Aerospace nickel-cadmium cell separator qualifications program

The present space qualified nylon separator, Pellon 2505 ML, is no longer available for aerospace nickel-cadmium (NiCd) cells. As a result of this anticipated unavailability, a joint Government program between the Air Force Space Division and the Naval Research Laboratory was established. Four cell types were procured with both the old qualified and the new unqualified separators. Acceptance, characterization, and life cycling tests are to be performed at the Naval Weapons Support Center, Crane, Ind. (NWSC/Crane). The scheduling and current status of this program are discussed and the progress of testing and available results are projected.

Francis, R. W.↗

Qualification of S-glass/epoxy thermal isolator bands

Unidirectional fiberglass reinforced epoxy structures have been evaluated as thermal isolator tension straps for the charge-coupled devices on the Hubble Space Telescope's Wide Field/Planetary Camera. Mechanical and thermal properties are reported for filament-wound S-2 glass in a generic epoxy resin and compared to S-901 glass bands used on a previous camera. Measurements were performed on very small paper clip-shaped bands. Probably the smallest in length and have a load carrying mean cross sectional area of only 0.00024 square inches.

Bauer, Jerry↗

Qualification testing of General Electric 50 Ah nickel-cadmium cells with Pellon 2536 separator and passivated positive plates

Forty-two 50 Ah nickel-cadmium cells were delivered to the Goddard Space Flight Center (GSFC) by General Electric (GE) in February, 1985 for the purpose of evaluating and qualifying a nonwoven nylon separator material, Pellon 2536, and the GE positive plate nickel attack control gas passivation process. Testing began May, 1985 at the Naval Weapons Support Center (NWSC) in Crane, Indiana with GSFC standard initial evaluation tests. Life cycling in both Low Earth Orbit (LEO) and Geosynchronous Orbit (GEO) began in July, 1985 with approximately 6500 LEO cycles and three GEO eclipse seasons completed. After early problems in maintaining test pack temperature control, all packs are performing well but are exhibiting higher than normal charge voltage characteristics.

Morrow, George W.↗

Qualification of room-temperature-curing epoxy adhesives for spacecraft structural applications

An adhesive-bonding test program is being conducted in order to develop structural adhesives applicable to JPL spacecraft. A noteworthy application for such an adhesive will be JPL's Galileo mission, whose trajectory will involve the circumnavigation of the planet Venus prior to Jupiter rendezvous, and will accordingly require stringent temperature and radiation environment requirements. The baseline adhesive for the test program is the EA 934 room temperature-cure epoxy, which has been widely used as a 'space-qualified' material.

Carpenter, Alain↗

Qualification Motor no. 8 (QM-8), volume 1

All inspection and instrumentation data indicate that the QM-8 static test firing conducted 20 January 1989 was successful. Ambient temperature at T-0 was 28 F. With two flights successfully accomplished, this final test in the redesigned solid rocket motor (RSRM) program certified that the design meets motor performance requirements under extreme cold conditions. This test was a prerequisite to the third flight. The entire test article was cold conditioned at 20 to 25 F for approximately 31 days to assure a maximum propellant mean bulk temperature (PMBT) of 40 F, making it the lowest PMBT in the history of the program. This extreme condition also presented the opportunity to certify critical components at low temperatures. Certification of field joint and igniter heaters, adhesive bondline integrity, flex bearing performance, flight instrumentation performance, RSRM seal performance, and LSC and nozzle plug performance was accomplished. Prior to motor ignition, the field joints were maintained between 75 to 130 F, the igniter-to-case joint was maintained between 75 to 123 F, and the case-to-nozzle joint was maintained between 75 to 120 F. QM-8 was tested with induced side loads to simulate the strut loads experienced during ignition and maximum aerodynamic loading conditions. The ability of the safe and arm device to change position from safe-to-arm and arm-to-safe was certified. Ballistics performance was certified at the lower limits. Values were within specification requirements. Nozzle performance was nominal with typical erosion. The use of Fiberite carbon-cloth phenolic was certified. The water deluge system, CO2 quench, and other test equipment performed as planned during all required test operations.

Garecht, D. M.↗

Field joint environmental protection system vibration/pressurization qualification

The procedures used and results obtained from vibration testing the redesigned solid rocket motor (RSRM) field joint environmental protection system (FJEPS), hereafter referred to as the joint protection system (JPS) are documented. The major purposes were to certify that the flight-designed JPS will withstand the dynamic environmental conditions of the redesigned solid rocket booster, and to certify that the cartridge check valve (vent valve) will relieve pressure build-up under the JPS during the initial 120 sec of flight. Also, an evaluation of the extruded cork insulation bonding was performed after the vibration testing.

Cook, M.↗

Field joint protection system rain qualification test report

This report documents the procedures, performance, and results obtained from the Field Joint Protection System (FJPS) rain test. This test was performed to validate that the flight configuration FJPS prevents the accumulation of moisture in the redesigned solid rocket motor (RSRM) field joints when subjected to simulated prelaunch natural rain environments. The FJPS test article was exposed to rain simulation for approximately 50 minutes. During the test, water entered through the open upper end of the systems tunnel and was funneled down between the tunnel and case. A sealant void at the moisture seal butt splice allowed this water to flow underneath the FJPS. The most likely cause of voids was improper bondline preparation, particularly on the moisture seal surface. In total, water penetrated underneath approximately 60 percent of the FJPS circumference. Because the test article was substantially different from flight configuration (no systems tunnel closeout), results of this test will not affect current flight motors. Due to the omission of systems tunnel covers and systems tunnel floor plate closeout, the test assembly was not representative of flight hardware and resulted in a gross overtest. It is therefore recommended that the test be declared void. It is also recommended that the test be repeated with a complete closeout of the systems tunnel, sealed systems tunnel ends, and improved adhesive bondline preparation.

Cook, M.↗

Codes and modalities in multiple resources - A success and a qualification

The relevance of codes and modalities in a multiple-resource model to the prediction of task interference was investigated in an experiment in which either verbal or spatial decision tasks, responded to with either voice or key press, were time-shared with second-order tracking. Results indicate the importance of the dichotomy between verbal and spatial processing codes in accounting for task interference. Interference with tracking was consistently greater, and difficulty/performance trade-offs were stronger, when the spatial decision task was performed and the manual response was used. A review of the literature on the interference between a continuous visual task and a discrete task whose modality is either auditory or visual suggests that scanning produces a dominant cost to intramodal configurations when visual channels are separated in space. In absence of visual separation, the differences between cross-modal and intramodal performance may be best accounted for by a mechanism of preemption.

Wickens, Christopher D.↗

Cable coupling lightning transient qualification

Simulated lightning strike testing of instrumentation cabling on the redesigned solid rocket motor was performed. Testing consisted of subjecting the lightning evaluation test article to simulated lightning strikes and evaluating the effects of instrumentation cable transients on cables within the system tunnel. The maximum short-circuit current induced onto a United Space Boosters, Inc., operational flight cable within the systems tunnel was 92 A, and the maximum induced open-circuit voltage was 316 V. These levels were extrapolated to the worst-case (200 kA) condition of NASA specification NSTS 07636 and were also scaled to full-scale redesigned solid rocket motor dimensions. Testing showed that voltage coupling to cables within the systems tunnel can be reduced 40 to 90 dB and that current coupling to cables within the systems tunnel can be reduced 30 to 70 dB with the use of braided metallic sock shields around cables that are external to the systems tunnel. Testing also showed that current and voltage levels induced onto cables within the systems tunnel are partially dependant on the cables' relative locations within the systems tunnel. Results of current injections to the systems tunnel indicate that the dominant coupling mode on cables within the systems tunnel is not from instrumentation cables but from coupling through the systems tunnel cover seam apertures. It is recommended that methods of improving the electrical bonding between individual sections of the systems tunnel covers be evaluated. Further testing to better characterize redesigned solid rocket motor cable coupling effects as an aid in developing methods to reduce coupling levels, particularly with respect to cable placement within the systems tunnel, is also recommended.

Cook, M.↗

JPS heater and sensor lightning qualification

Simulated lightning strike testing of the Redesigned Solid Rocket Motor (RSRM) field joint protection system heater assembly was performed at Thiokol Corp., Wendover Lightning Facility. Testing consisted of subjecting the lightning evaluation test article to simulated lightning strikes and evaluating the effects of heater cable transients on cables within the systems tunnel. The maximum short circuit current coupled onto a United Space Boosters, Inc. operational flight cable within the systems tunnel, induced by transients from all cables external to the systems tunnel, was 92 amperes. The maximum open-circuit voltage coupled was 316 volts. The maximum short circuit current coupled onto a United Space Boosters, Inc. operational flight cable within the systems tunnel, induced by heater power cable transients only, was 2.7 amperes; the maximum open-circuit voltage coupled was 39 volts. All heater power cable induced coupling was due to simulated lightning discharges only, no heater operating power was applied during the test. The results showed that, for a worst-case lightning discharge, the heater power cable is responsible for a 3.9 decibel increase in voltage coupling to operational flight cables within the systems tunnel. Testing also showed that current and voltage levels coupled onto cables within the systems tunnel are partially dependant on the relative locations of the cables within the systems tunnel.

Cook, M.↗

Qualification of room-temperature-curing structural adhesives for use on JPL spacecraft

An evaluation is made of the comparative advantages of numerous room temperature-cure structural primers and adhesives applicable to spacecraft structures. The EA 9394 adhesive and BR 127 primer were chosen for use in all primary structure bonding on the Galileo spacecraft, in virtue of adequate room-temperature lap shear and peel strengths and superior mechanical properties above 200 F. EA 9394 also offers superior work life, shelf-life, and storage properties, by comparison with the EA 934 alternative.

Carpenter, Alain↗

Qualification and life testing of a flight design hydrazine arcjet system

This paper describes the design and the requirements of a low-power hydrazine arc jet system and presents the results of tests on the system's performance, vibration, and lifetime. The system consists of an arcjet, catalyst bed, power control unit, and interconnecting power cable. Operating at 1.4 kW input power, the system provides a minimum of 450 sec mission average specific impulse, yielding greater than a 100 kg propellant savings over standard monopropellant or bipropellant systems used on communication satellites.

Knowles, S. C.↗

Space shuttle redesigned solid rocket motor Certificate of Qualification (COQ) data report

The Space Shuttle Redesigned Solid Rocket Motor (RSRM) Certification Program provides confidence that the RSRM and its components/subsystems meet or exceed Mission Oriented Requirements when manufactured per design requirements and specified/approved processes. Certification is based on documented results of tests, analyses, inspections, similarity, and demonstrations. Evidencing information is provided to certify that each RSRM component/subsystem satisfies design, mission related requirements and objectives.

Duersch, Fred, Jr.↗

Qualification of the gritblast assembly and process for the inside diameter of the RSRM forward and aft domes

This gritblast assembly shall be used when refurbishing the Inside Diameter (ID) of RSRM forward and aft domes. Initial blasting is used to remove corrosion and adhesive not removed during the insulation washout. Final blasting is conducted just prior to part finalization in order to remove residual contamination and prepare the ID surface for bonding. The media used in this gritblaster is DuPont Zirclean Blasting Abrasive. It is possible to use other media in this gritblast assembly, however the only facility that has the control capability for this assembly is the Zirclean blast booth. This blast booth can not use other media without the occurrence of contamination. This automated process shall replace the manually controlled gritblasting that is currently in operation. Manual gritblasting does not provide the consistency, control, and safety that an automated process is capable of delivering.

Nolan, Michael J.↗