Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION FALL OUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Chlorine Worth Study in Support of PF-4 Operations [Slides]

The primary concern of this study is if experiments can be designed/conducted to provide technical justification to NCS in order to increase mass limits. This goal is in direct support of 30 pits per year mission, one of the top priorities for NNSA. The accelerated timeline is as follows: Initial tasking, June 2020; preliminary design completion (CED-1 equivalent), November 2020; final design completion (CED-2 equivalent), March 2021; part receipt and inspection completion (CED-3a equivalent), October 2021; experiment execution (CED-3b equivalent), December 2021; experiment documentation write-up completion (start CED-4a equivalent), January 2022; and ICSBEP target (CED-4a equivalent), Fall 2022.

2019 ARCHIMEDES LDRD project↗

Advanced Test Reactor Neutron Dosimetry Report - Cycle 175B-1

Results of neutron dosimetry measurements in ATR for cycle 175B-1 are presented. A single set of cobalt and nickel wires were installed in numerous irradiation locations for the duration of the cycle. The specific activity of these wire segments can be used in conjunction with the presented cycle history information to determine the thermal- and fast-neutron fluence rates for each irradiation position during the cycle using the referenced standard test methods.

175B↗

SU-E-T-435: Development and Commissioning of a Complete System for In-Vivo Dosimetry and Range Verification in Proton Therapy

Purpose: In-vivo dose and beam range verification in proton therapy could play significant roles in proton treatment validation and improvements. Invivo beam range verification, in particular, could enable new treatment techniques one of which, for example, could be the use of anterior fields for prostate treatment instead of opposed lateral fields as in current practice. We have developed and commissioned an integrated system with hardware, software and workflow protocols, to provide a complete solution, simultaneously for both in-vivo dosimetry and range verification for proton therapy. Methods: The system uses a matrix of diodes, up to 12 in total, but separable into three groups for flexibility in application. A special amplifier was developed to capture extremely small signals from very low proton beam current. The software was developed within iMagX, a general platform for image processing in radiation therapy applications. The range determination exploits the inherent relationship between the internal range modulation clock of the proton therapy system and the radiological depth at the point of measurement. The commissioning of the system, for in-vivo dosimetry and for range verification was separately conducted using anthropomorphic phantom. EBT films and TLDs were used for dose comparisons and range scan of the beam distal fall-off was used as ground truth for range verification. Results: For in-vivo dose measurement, the results were in agreement with TLD and EBT films and were within 3% from treatment planning calculations. For range verification, a precision of 0.5mm is achieved in homogeneous phantoms, and a precision of 2mm for anthropomorphic pelvic phantom, except at points with significant range mixing. Conclusion: We completed the commissioning of our system for in-vivo dosimetry and range verification in proton therapy. The results suggest that the system is ready for clinical trials on patient.

07 ISOTOPE AND RADIATION SOURCES↗

A regional nuclear conflict would compromise global food security

A limited nuclear war between India and Pakistan could ignite fires large enough to emit more than 5 Tg of soot into the stratosphere. Climate model simulations have shown severe resulting climate perturbations with declines in global mean temperature by 1.8 °C and precipitation by 8%, for at least 5 y. Here we evaluate impacts for the global food system. Six harmonized state-of-the-art crop models show that global caloric production from maize, wheat, rice, and soybean falls by 13 (±1)%, 11 (±8)%, 3 (±5)%, and 17 (±2)% over 5 y. Total single-year losses of 12 (±4)% quadruple the largest observed historical anomaly and exceed impacts caused by historic droughts and volcanic eruptions. Colder temperatures drive losses more than changes in precipitation and solar radiation, leading to strongest impacts in temperate regions poleward of 30°N, including the United States, Europe, and China for 10 to 15 y. Integrated food trade network analyses show that domestic reserves and global trade can largely buffer the production anomaly in the first year. Persistent multiyear losses, however, would constrain domestic food availability and propagate to the Global South, especially to food-insecure countries. By year 5, maize and wheat availability would decrease by 13% globally and by more than 20% in 71 countries with a cumulative population of 1.3 billion people. In view of increasing instability in South Asia, this study shows that a regional conflict using <1% of the worldwide nuclear arsenal could have adverse consequences for global food security unmatched in modern history.

54 ENVIRONMENTAL SCIENCES↗

The Voltage Boost Enabled by Luminescence Extraction in Solar Cells

A new physical principle has emerged to produce record voltages and efficiencies in photovoltaic cells, 'luminescence extraction.' This is exemplified by the mantra 'a good solar cell should also be a good LED.' Luminescence extraction is the escape of internal photons out of the front surface of a solar cell. Basic thermodynamics says that the voltage boost should be related to concentration ratio, C, of a resource by ..delta..V=(kT/q)ln{C}. In light trapping, (i.e. when the solar cell is textured and has a perfect back mirror) the concentration ratio of photons C={4n2}, so one would expect a voltage boost of ..delta..V=kT ln{4n2} over a solar cell with no texture and zero back reflectivity, where n is the refractive index. Nevertheless, there has been ambiguity over the voltage benefit to be expected from perfect luminescence extraction. Do we gain an open circuit voltage boost of ..delta..V=(kT/q)ln{n2}, ..delta..V=(kT/q)ln{2n2}, or ..delta..V=(kT/q)ln{4n2}? What is responsible for this voltage ambiguity ..delta..V=(kT/q)ln{4}=36mVolts? We show that different results come about, depending on whether the photovoltaic cell is optically thin or thick to its internal luminescence. In realistic intermediate cases of optical thickness the voltage boost falls in between; ln{n2}q..delta..V/kT)<;ln{4n2}.

14 SOLAR ENERGY↗

Luminescence Properties of FZ Silicon Irradiated with Swift Heavy Ions

The optical properties of float-zone (FZ) silicon irradiated with swift heavy ions (SHI) are studied. In the low-temperature photoluminescence spectra, a broad peak in the range 1.3–1.5 μm is evident along with the well-known X, W, W', R, and C lines. In this case, it is found that, as the irradiation dose is increased in the range 3 × 10{sup 11}–10{sup 13} cm{sup –2}, the photoluminescence peak falls and narrows and, at the same time, its maximum shifts to longer wavelengths.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The use of a silicon strip detector dose magnifying glass in stereotactic radiotherapy QA and dosimetry

Purpose: Stereotactic radiosurgery/therapy (SRS/SRT) is the use of radiation ablation in place of conventional surgical excision to remove or create fibrous tissue in small target volumes. The target of the SRT/SRS treatment is often located in close proximity to critical organs, hence the requirement of high geometric precision including a tight margin on the planning target volume and a sharp dose fall off. One of the major problems with quality assurance (QA) of SRT/SRS is the availability of suitable detectors with the required spatial resolution. The authors present a novel detector that they refer to as the dose magnifying glass (DMG), which has a high spatial resolution (0.2 mm) and is capable of meeting the stringent requirements of QA and dosimetry in SRS/SRT therapy. Methods: The DMG is an array of 128 phosphor implanted n{sup +} strips on a p-type Si wafer. The sensitive area defined by a single n{sup +} strip is 20x2000 {mu}m{sup 2}. The Si wafer is 375 {mu}m thick. It is mounted on a 0.12 mm thick Kapton substrate. The authors studied the dose per pulse (dpp) and angular response of the detector in a custom-made SRS phantom. The DMG was used to determine the centers of rotation and positioning errors for the linear accelerator's gantry, couch, and collimator rotations. They also used the DMG to measure the profiles and the total scatter factor (S{sub cp}) of the SRS cones. Comparisons were made with the EBT2 film and standard S{sub cp} values. The DMG was also used for dosimetric verification of a typical SRS treatment with various noncoplanar fields and arc treatments when applied to the phantom. Results: The dose per pulse dependency of the DMG was found to be <5% for a dpp change of 7.5 times. The angular response of the detector was investigated in the azimuthal and polar directions. The maximum polar angular response was 13.8% at the gantry angle of 320 deg., which may be partly due to the phantom geometry. The maximum azimuthal angular response was 15.3% at gantry angles of 90 deg. and 270 deg. The angular response at the gantry angle of 180 deg. was 6.3%. A correction function was derived to correct for the angular dependence of the detector, which takes into account the contribution of the azimuthal and polar angular response at different treatment couch positions. The maximum positioning errors due to collimator, gantry, and couch rotation were 0.2{+-}0.1, 0.4{+-}0.1, and 0.4{+-}0.2 mm, respectively. The SRS cone S{sub cp} agrees very well with the standard data with an average difference of 1.2{+-}1.1%. Comparison of the relative intensity profiles of the DMG and EBT2 measurements for a simulated SRS treatment shows a maximum difference of 2.5%. Conclusions: The DMG was investigated for dose per pulse and angular dependency. Its application to SRS/SRT delivery verification was demonstrated. The DMG with its high spatial resolution and real time capability allows measurement of dose profiles for cone applicators down to 5 mm in diameter, both accurately and rapidly as required in typical SRS/SRT deliveries.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nonstationarity of the Efficiency Coefficient and Heating Temperatures of Water in Flat-Plate Solar Collectors

A one-dimensional nonstationary three-element distributed thermal model of a flat-plate collector with allowance for time variation of the temperatures through the “thickness” of the elements and along the length of the solar collector (SC) has been developed and software-implemented. The main data in this model consist of the thermophysical and overall parameters of the collector elements, heat carrier inlet velocity, solar radiation density, and ambient and sky temperature. To decrease the calculation variants, the variation ranges of mass flow of the heat carrier and its flow velocity were estimated for the characteristic parameters of the heat-removal channels of flat-plate SCs. It has been found that the specific mass flows of water in flat-plate SCs are 2.5–10 g/(s m{sup 2}), and the water flow velocity is 0.0005–0.002 m/s. It is shown that the instantaneous efficiency coefficient and temperature of the heat carrier can fall outside stationary values within 1–3 h. However, the daily efficiency coefficients of the SC do not fall outside the stationary values even within a day. The developed flat-plate SC model can be used to estimate the influence of the thermophysical and overall parameters of the elements, as well as the parameters of the environment, on its thermophysical characteristics when developing flat-plate SCs and methods for experimentally determining their characteristics.

14 SOLAR ENERGY↗

The Cali Meteorite: Luminescence of a recently fallen H/L ordinary chondrite

The Cali meteorite fall occurred on 6 July 2007 at 21h33m+-1m UTC. Some specimens were recovered just after their fall so they are extremely fresh materials. Mineral analysis and bulk chemistry revealed that the measured abundances for most elements closely match the values recorded for other ordinary chondrites classified as H/L. We present here thermoluminescence studies of this recently fallen meteorite in order to get additional information on the radiation environment, and the thermal history of this meteorite. Such information is revealed to be complementary with the range of orbital elements deduced from eyewitness reports of the fireball.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Circumstellar {sup 12}C/{sup 13}C isotope ratios from millimeter observations of CN and CO: Mixing in carbon- and oxygen-rich stars

A survey of the {sup 12}C/{sup 13}C ratio toward circumstellar envelopes has been conducted at millimeter wavelengths using the facilities of the Arizona Radio Observatory (ARO). The ratios were obtained for a sample of local C- and O-rich asymptotic giant branch and supergiant stars from observations of the {sup 12}C and {sup 13}C isotopologues of CO and CN, respectively. The J = 1 {yields} 0 transitions of both molecules were observed at {lambda} = 3 mm using the ARO 12 m telescope, while the J = 2 {yields} 1 lines of the two species were measured using the ARO Sub-Millimeter Telescope (SMT) at {lambda} = 1 mm. The {sup 12}C/{sup 13}C ratios were determined from the CO data by modeling both transitions simultaneously with a circumstellar radiative transfer code, which can account for the high opacities present in the emission from this species. In the case of CN, the hyperfine structure was used to evaluate opacity effects. Ratios obtained independently from CO and CN are in good agreement. For the C-rich envelopes, the ratios fall in the range {sup 12}C/{sup 13}C {approx} 25-90, while the O-rich shells have values of 10-35. Ratios of {sup 12}C/{sup 13}C {approx} 3-14 are found for the supergiant stars, with the exception of VY CMa, where the values lie in the range 25-46. All ratios obtained in this study are {<=} 89, the solar value, suggesting that substantial carbon-13 enrichment may be currently occurring in the local interstellar medium. A qualitative model was constructed based on first and third dredge-up convective mixing that can reproduce the observed ratios. Substantial mixing of H-burning products must occur to explain the ratios in the O-rich objects, while a wide range of {sup 12}C/{sup 13}C values can be generated by only a few percent mixing of He-burning ashes in the C-rich case. The {sup 12}C/{sup 13}C ratios obtained in this study should help improve stellar yield models and contribute to the understanding of Galactic chemical evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

ANGULAR MOMENTUM AND GALAXY FORMATION REVISITED: EFFECTS OF VARIABLE MASS-TO-LIGHT RATIOS

We rederive the relation between the specific angular momentum j {sub *} and the mass M {sub *} of the stellar matter in galaxies of different morphological types. This is a revision of the j {sub *}-M {sub *} diagram presented in our recent comprehensive study of galactic angular momentum. In that work, we estimated j {sub *} from kinematic and photometric data that extended to large radii and M {sub *} from near-infrared luminosities L{sub K} with an assumed universal mass-to-light ratio M {sub *}/L{sub K} . However, recent stellar population models show large variations in M {sub *}/L{sub K} correlated with B – V color. In the present work, we use this correlation to estimate M {sub *}/L{sub K} and hence M {sub *} from the measured B – V and L{sub K} . Our revised j {sub *}-M {sub *} diagram is similar to our previous one; both disk-dominated and elliptical galaxies follow nearly parallel sequences with j{sub ⋆}∝M{sub ⋆}{sup α} and α = 0.6 ± 0.1. However, the offset between the sequences is now a factor of about 5, some 30% larger than before (and close to the offset found by Fall in 1983). Thus, our new results place even tighter constraints on the loss of specific angular momentum by galactic disks over their lifetimes.

79 ASTRONOMY AND ASTROPHYSICS↗

THE MAJOR GEOEFFECTIVE SOLAR ERUPTIONS OF 2012 MARCH 7: COMPREHENSIVE SUN-TO-EARTH ANALYSIS

During the interval 2012 March 7–11 the geospace experienced a barrage of intense space weather phenomena including the second largest geomagnetic storm of solar cycle 24 so far. Significant ultra-low-frequency wave enhancements and relativistic-electron dropouts in the radiation belts, as well as strong energetic-electron injection events in the magnetosphere were observed. These phenomena were ultimately associated with two ultra-fast (>2000 km s{sup −1}) coronal mass ejections (CMEs), linked to two X-class flares launched on early 2012 March 7. Given that both powerful events originated from solar active region NOAA 11429 and their onsets were separated by less than an hour, the analysis of the two events and the determination of solar causes and geospace effects are rather challenging. Using satellite data from a flotilla of solar, heliospheric and magnetospheric missions a synergistic Sun-to-Earth study of diverse observational solar, interplanetary and magnetospheric data sets was performed. It was found that only the second CME was Earth-directed. Using a novel method, we estimated its near-Sun magnetic field at 13 R{sub ⊙} to be in the range [0.01, 0.16] G. Steep radial fall-offs of the near-Sun CME magnetic field are required to match the magnetic fields of the corresponding interplanetary CME (ICME) at 1 AU. Perturbed upstream solar-wind conditions, as resulting from the shock associated with the Earth-directed CME, offer a decent description of its kinematics. The magnetospheric compression caused by the arrival at 1 AU of the shock associated with the ICME was a key factor for radiation-belt dynamics.

79 ASTRONOMY AND ASTROPHYSICS↗

The FE-I4 Pixel Readout Chip and the IBL Module

FE-I4 is the new ATLAS pixel readout chip for the upgraded ATLAS pixel detector. Designed in a CMOS 130 nm feature size process, the IC is able to withstand higher radiation levels compared to the present generation of ATLAS pixel Front-End FE-I3, and can also cope with higher hit rate. It is thus suitable for intermediate radii pixel detector layers in the High Luminosity LHC environment, but also for the inserted layer at 3.3 cm known as the 'Insertable B-Layer' project (IBL), at a shorter timescale. In this paper, an introduction to the FE-I4 will be given, focusing on test results from the first full size FE-I4A prototype which has been available since fall 2010. The IBL project will be introduced, with particular emphasis on the FE-I4-based module concept.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Clues to the Nature of Massive Star Explosions from GRB X-ray afterglows

X-ray afterglows of long gamma-ray bursts (GRBs) provide some insights into the details of massive star explosions. Clues to the nature of the progenitors can be found from the ''canonical'' phases of X-ray afterglows, including the initial steeply falling phase seen in many X-ray afterglows, the flat 'plateau' phase, and the X-ray flares. The data point to extended central engine activity lasting much longer than the duration of the prompt gamma-ray emission, possibly indicating that the stellar collapse is protracted by fall-back of material for many hours after the explosion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Systematic study of multifragmentation in asymmetric colliding nuclei

We present a complete systematically theoretical study of multifragmentation for asymmetric colliding nuclei for heavy-ion reactions in the energy range between 50 MeV/nucleon and 600 MeV/nucleon by using soft and hard equations of state. This study is performed within an isospin-dependent quantum-molecular dynamics model. To see the effect of mass asymmetry, simulations are carried out in the absence of Coulomb interactions. Coulomb interactions enhance the production of fragments by about 20%. We envision an interesting outcome for large asymmetric colliding nuclei. Although nearly symmetric nuclei depict a well-known trend for rising and falling with a peak around E=100 MeV/nucleon, this trend, however, is completely missing for large asymmetric nuclei. Therefore, experiments are needed to verify this prediction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

FORMATION OF GLOBULAR CLUSTERS IN ATOMIC-COOLING HALOS VIA RAPID GAS CONDENSATION AND FRAGMENTATION DURING THE EPOCH OF REIONIZATION

We investigate the formation of metal-poor globular clusters (GCs) at the center of two dark matter halos with M{sub halo}∼4×10{sup 7} M{sub ⊙} at z>10 using cosmological radiation-hydrodynamics simulations. We find that very compact (≲1 pc) and massive (∼6×10{sup 5} M{sub ⊙}) clusters form rapidly when pristine gas collapses isothermally with the aid of efficient Lyα emission during the transition from molecular-cooling halos to atomic-cooling halos. Because the local free-fall time of dense star-forming gas is very short (≪1 Myr), a large fraction of the collapsed gas is turned into stars before stellar feedback processes blow out the gas and shut down star formation. Although the early stage of star formation is limited to a small region of the central star-forming disk, we find that the disk quickly fragments due to metal enrichment from supernovae. Sub-clusters formed in the fragmented clouds eventually merge with the main cluster at the center. The simulated clusters closely resemble the local GCs in mass and size but show a metallicity spread that is much wider than found in the local GCs. We discuss a role of pre-enrichment by Pop III and II stars as a potential solution to the latter issue. Although not without shortcomings, it is encouraging that a naive blind (not tuned) cosmological simulation presents a possible channel for the formation of at least some massive GCs.

79 ASTRONOMY AND ASTROPHYSICS↗

EVIDENCE OF HOT HIGH VELOCITY PHOTOIONIZED PLASMA FALLING ON ACTIVELY ACCRETING T TAURI STARS

The He II (1640 Å) line and the resonance doublet of N V (UV1) provide a good diagnostic tool to constrain the excitation mechanism of hot (T{sub e} > 40,000 K) atmospheric/magnetospheric plasmas in T Tauri stars (TTSs). Making use of the data available in the Hubble Space Telescope archive, this work shows that there are at least two distinct physical components contributing to the radiation in these tracers: the accretion flow sliding on the magnetosphere and the atmosphere. The N V profiles in most sources are symmetric and at rest with respect to the star. The velocity dispersion of the profile increases from non-accreting (σ = 40 km s{sup –1}) to accreting (σ = 120 km s{sup –1}) TTSs, suggesting that the macroturbulence field in the line formation region decreases as the stars approach the main sequence. Evidence of the N V line being formed in a hot solar-like wind has been found in RW Aur, HN Tau, and AA Tau. The He II profile has a strong narrow component that dominates the line flux; the dispersion of this component ranges from 20 to 60 km s{sup –1}. Current data suggest that both accretion shocks and atmospheric emission might contribute to the line flux. In some sources, the He II line shows a broad and redward-shifted emission component often accompanied by semiforbidden O III] emission that has a critical electron density of ∼3.4 × 10{sup 10} cm{sup 3}. In spite of their different origins (inferred from the kinematics of the line formation region), N V and He II fluxes are strongly correlated, with only the possible exception of some of the heaviest accretors.

79 ASTRONOMY AND ASTROPHYSICS↗

Dosimetric comparison of flattened and unflattened beams for stereotactic ablative radiotherapy of stage I non-small cell lung cancer

Purpose: To compare contribution and accuracy of delivery for two flattening filter free (FFF) beams of the nominal energy 6 and 10 MV and a 6 MV flattened beam for early stage lung cancer. Methods: For each of 11 patients with stage I nonsmall cell lung cancer three volumetric modulated arc therapy plans were prepared utilizing a 6 MV flattened photon beam (X6FF) and two nonflattened beams of nominal energy 6 and 10 MV (X6FFF, X10FFF). Optimization constraints were set to produce dose distributions that meet the criteria of the RTOG-0915 protocol. The radiation schedule used for plan comparison in all patients was 50 Gy in five fractions. Dosimetric parameters of planning target volume (PTV) and organs-at-risk and delivery times were assessed and compared. All plans were subject to verification using Delta{sup 4} unit (Scandidos, Sweden) and absolutely calibrated gafchromic films in a thorax phantom. Results: All plans had a qualitatively comparable outcome. Obtained dose distributions were conformal (CI < 1.17) and exhibited a steep dose fall-off outside the PTV. The ratio of monitor units for FFF versus FF plans in the authors' study ranged from 0.95 to 1.21 and from 0.93 to 1.25 for X6FFF/X6FF and X10FFF/X6FF comparisons, respectively. The ratio systematically increased with increasing size of the PTV (up to +25% for 150 cm{sup 3} PTV). Yet the integral dose to healthy tissue did not follow this trend. Comparison of cumulative dose volume histograms for a patient's body showed that X6FFF plans exhibit improved conformity and reduced the volume of tissue that received more than 50% of the prescription dose. Parameters related to dose gradient showed statistically significant improvement. CI{sub 50%}, CI{sub 60%}, CI{sub 80%}, and CI{sub 100%} were on average reduced by 4.6% (p < 0.001), 4.6% (p = 0.002), 3.1% (p = 0.002), and 1.2% (p = 0.039), respectively. Gradient measure was on average reduced by 4.2% (p < 0.001). Due to dose reduction in the surrounding lung tissue, the V{sub 20} {sub Gy} and V{sub 12.5} {sub Gy} were reduced by 5.5% (p = 0.002) and 4.5% (p < 0.001). These dosimetric improvements in the fall-off were not observed for the X10FFF plans. Differences in sparing of normal tissues were not found to be statistically significant for either of the two FFF beams. Mean beam-on times were 111 s (2SD = 11 s) for X10FFF, 128 s (2SD = 19 s) for X6FFF, and X6FF plans required on average 269 s (2SD = 71 s). While the mean dose rate was 1555 ± 264 and 1368 ± 63 MU/min, for X10FFF and X6FFF, plans using the conventional X6FF were delivered with the constant maximum dose rate of 600 MU/min. Verification of all plans showed acceptable and comparable results for all plans in homogeneous as well as heterogeneous phantoms. Mean GS (3%, 2 mm) using the Delta{sup 4} phantom were 98.9% (2SD = 3.2%), 99.2% (2SD = 2.3%), and 99.2% (2SD = 2.3%) for X6FFF, X6FF, and X10FFF modalities. Verification using a thorax phantom showed GS > 98% in all cases. Conclusions: The use of FFF beams for stereotactic radiation therapy of nonsmall cell lung cancer patients yielded dose distributions qualitatively comparable to flattened beams and significantly reduced treatment delivery time. Utilizing the X6FFF beam improved conformity of dose distribution. On the other hand, X10FFF beam offered a slight improvement in treatment efficiency, and lower skin and peripheral dose. All effects were relatively small.

62 RADIOLOGY AND NUCLEAR MEDICINE↗