Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIOACTIVE SOURCES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Prototype for Unclassified Algorithm

Continuing previous efforts to investigate and develop the Unclassified Radioisotope Algorithm, the goal of the FY19-FY20 effort was to develop a prototype detector system which uses the algorithm to confirm warhead attributes related to the presence of either weapons grade plutonium (WGPu) or highly enriched uranium (HEU). The final deliverable is a prototype attribute measurement system built with common, commercially available gamma radiation detector components, capable of confirming the presence of specific, complex radioactive sources of interest, without the collection and storage of gamma energy spectra. This is accomplished by processing each gamma pulse as it is received, applying weight values based on the energy and incrementing or decrementing scalar counters which can be compared with expected values to determine if the measured source is consistent with WGPu or HEU. This report documents the design of the prototype system as well as the development of the algorithm and performance testing results. While the previously conceptualized, simple algorithm resulted in a prohibitive amount of false positives, the goal for a simple attribute measurement system capable of verifying Ba-133 and Ra-226 (weapons grade plutonium and highly enriched uranium surrogate testing sources) at over 95% accuracy with sub 5% false positive rate was demonstrated.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Report of the Sixth Regional Review Meeting of the Radiological Security Partnership.

The Sri Lanka Atomic Energy Regulatory Commission (AERC) and the United States Department of Energy (U.S. DOE) co-hosted the 6th Regional Review Meeting on Radiological Security involving representatives from over 20 countries, the International Atomic Energy Agency (IAEA), the International Criminal Police Organization (INTERPOL), and the World Institute for Nuclear Security. The purpose of the event was to discuss the implementation of, and plans for, high-activity radioactive source security (RSS). The U.S. DOE’s National Nuclear Security Administration (NNSA) Office of Radiological Security (ORS) fully sponsored this review meeting. Participants were welcomed to Colombo, Sri Lanka, and the meeting was formally opened by Nirmali Karunarathna of the Sri Lanka Atomic Energy Regulator Council who emphasized the strong partnerships among the participants. The opening Ceremony and Lamp Lighting included dignitaries from the sponsoring countries. Robert Hilton, Deputy Chief of Mission at the U.S. Embassy in Colombo, and Kristin Hirsch of the ORS gave other opening remarks that highlighted the social benefit from radiological sources in medicine, industry, and agriculture, while stressing the importance of addressing the risks associated with the malicious use of radiological sources. Emphasis was placed on the importance of partnerships among all the participants to help ensure the success of securing radiological materials throughout the world and the opportunity to share information and experiences. AERC was acknowledged with special thanks for hosting this event. A participant list is included as Attachment A, and the meeting agenda is provided as Attachment B. All presentations were made available to participants. The following sections summarize the meeting’s presentations, discussions, issues, suggestions, and recommendations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiobiological Studies Using Cs-137 Gamma or 320 kV X Rays

There are numerous self-shielded research irradiators used in various facilities throughout the United States. The irradiators employ radioactive sources containing either 137 Cs or 60 Co and the irradiators are used for a variety of radiobiological investigations involving cellular and/or animal models. A report from the National Academy of Sciences described security issues associated with particular radiation sources and the desire for their replacement with suitable X-ray irradiators. One possible replacement would be a 320 kV X-ray irradiator. The participants in this research successfully performed in vivo radiobiological studies involving mice exposed to filtered (HVL ≈ 4 mm Cu) 320 kV X rays. Two publications (one published and one submitted at the publishing of this report) documenting key findings are provided in Appendices A and B of this report. The 320 kV X rays were found suitable for in vivo (in mice) cell survival studies and are expected to be suitable for bone marrow transplantation studies using mice but this needs to be experimentally validated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated Internal Energy Calibration by OnTheFly for AGR-5/6/7

The software program, OnTheFly, was developed at Idaho National Laboratory (INL) to keep high-purity germanium (HPGe) detectors energy calibrated during very long experiments. Over time, spectra produced from a HPGe detector will slowly stretch or contract, causing the energy calibration to change. If the energy calibration changes too much, it will cause energy lines to be misidentified. The higher the energy line the more affected they are by this change. OnTheFly tracks and adjusts the slowly changing energy calibrations so the energy lines will not be misidentified. OnTheFly was used with the Fission Product Monitoring System (FPMS) during the AGR-5/6/7 irradiation experiment performed at INL’s Advanced Test Reactor (ATR). Five HPGe detectors were used to monitor the five capsules in AGR-5/6/7. There were also two extra HPGe detectors that were maintained as spares. Before each ATR cycle of the experiment, the HPGe detectors were energy calibrated with a thorium radioactive source. During each ATR cycle, each detector would acquire data for 8 hours and then reset and acquire data for another 8 hours. After each 8-hour run, the spectra would be saved and analyzed autonomously. The results were then read by OnTheFly and used to produce a new energy calibration for each detector. The new energy calibrations were compared to the current energy calibrations and, if certain criteria were met, the new energy calibration would replace the current energy calibration. The new energy calibration would be used for future spectra. OnTheFly was run at least every couple of days but could be run as much as after each 8-hour run. OnTheFly kept the spectra energy calibrated during the ATR cycles over the 2 years and 5 months that the AGR-5/6/7 experiment ran.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Perspectives on Response to an Abnormal Radiological Event [Slides]

On May 2, 2019, a sealed radioactive source containing cesium-137 was breached at the University of Washington Harborview Research and Training (HRT) Building in downtown Seattle while attempting to recover the source for the National Nuclear Security Administration’s (NNSA’s) Off-site Source Recovery Program (OSRP). The breach of the source resulted in the contamination of personnel, large sections of the building, and a release of material to the local environment.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

The Russian Invasion of Ukraine and Nuclear Security

You have in your hands a unique publication. Voices of Ukraine is a collection of testimonies from people working in the nuclear and radioactive source sector in Ukraine. The five texts in this extract are a preview of the full volume that will be published in early 2023. The accounts presented in this extract are very different from the newspaper articles or reports you may have read about the Russian invasion of Ukraine and the attack on and occupation of the Chornobyl Exclusion Zone and Zaporizhzhia NPP. Five people share their own stories of the personal and professional dilemmas they faced: How to endure an unending shift under enemy occupation when replacement workers weren’t permitted to relieve the staff; whether to remain in your childhood home or to flee abroad; how to support your community and country while maintaining the safe operation of nuclear sites in wartime conditions? The narratives of these individuals have far-reaching consequences for the nuclear sector in Ukraine but also far beyond it.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Radon Survey of Los Alamos National Laboratory Buildings and Los Alamos County Residential Buildings

A radon survey of office spaces was of interest to LANL for several reasons. First, exposure to natural radon in LANL office spaces has been considered to be outside the regulatory reach of the federal regulations and the U.S. Department of Energy (U.S. DOE) orders, and thus has not been studied as extensively as occupational exposure to other radionuclides and is not subject to the same rigorous radiological controls. Second, a general survey of radon concentrations in LANL workspaces was of interest to management to ensure safe environments for workers and is in keeping with the intent of OSHA requirements. Though radon in LANL offices would not be derived from enhanced radioactive sources, radon exposure in general office spaces has the potential to significantly impact worker risk. The purpose of the 2009 radon survey was to measure and document indoor radon levels across a broad spectrum of office-type workspaces and neighboring homes. The measured concentrations were compared against those measured across the United States and across the world. The results were also compared against a wide variety of radiation protection thresholds such as (1) the action levels of 148 Bq m -3 (the U.S. EPA action level for public housing), (2) ≈1,200 Bq m -3 OSHA threshold for office spaces, (3) effective dose threshold of 1 mSv threshold for defining a radiological worker, (4) 50 mSv occupational effective dose limit, and (5) 0.1 mSv and 1 mSv limits for public exposures from the air pathway and all pathways, respectively.

07 ISOTOPE AND RADIATION SOURCES↗

LLE Diagnostic Resource Team for Innovative Fusion Concepts (Final Report)

The LLE Diagnostic Resource Team for Innovative Fusion Concepts provided travelling neutron diagnostics, consultancy on neutron diagnostics, and consultancy on tritium handling to fusion companies. An existing neutron detector was recalibrated for low yields and two detectors were built based on designs proven on the Omega Laser Facility. The three detectors allow measurements over a wide range of yields (from 10 to 1E7 incident neutrons). The detectors were calibrated for DD neutrons on a dedicated OMEGA shot day. Neutron detectors from the company MIFTI were also calibrated on OMEGA. MIFTI is currently using their detectors and two of our detectors on staged Z-pinch experiments at UCSD. The Team acted as consultants for the development of a liquid scintillator array to detect neutrons from muon induced fusion by NK Labs. Segments of NK Labs’ detector were tested at the LLE using radioactive sources and a DD neutron generator. The Team also acted as consultants for the design of a tritium handling system for NK Labs. A new type of neutron spectrometer was designed and built, and has completed preliminary testing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Gallium Anomaly and the BEST Experiment [Slides]

The measurements of the charged-current capture rate of neutrinos on 71 Ga from strong radioactive sources have yielded results below those expected, based on the known strength of the principal transition supplemented by theory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Report Series: Finding of Effect, and Mitigation Documentation for Building 23-702, Mercury, Area 23, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) plans to demolish Building 23-702 in the town of Mercury (Nevada State Historic Preservation Office [SHPO] Resource No. B15278), which is on the Nevada National Security Site (NNSS) in Nye County, Nevada (see Figure 1). The purpose of the undertaking is related to the modernization of Mercury for future mission needs. The NNSA/NFO will implement this undertaking in accordance with the Programmatic Agreement between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer Regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada, hereafter referred to as the Mercury PA. Building 23-702 was built in 1965 as a foil handling building for the Los Alamos Scientific Laboratory (LASL), who worked on the design and engineering of nuclear weapons and other nuclear experiments. The building appeared to have secondarily functioned as a storage for radioactive sources in the 1980s and 1990s. The building was operational until 2004, then deactivated sometime between 2005 and 2014. The town of Mercury and the immediate surrounding area have been formally determined eligible for listing in the National Register of Historic Places (National Register, NRHP) as the Mercury Historic District (MHD, SHPO Resource No. D230) under Criteria A and C for its importance in supporting nuclear testing and scientific research from 1951 through 1992. Building 23-702 was identified as a contributing element to the MHD in a 2018 architectural survey of the district (Reno et al.) and recorded on a Nevada Architectural Resource Assessment (ARA) form (Reno et al. 2017). Building 23-702 was also identified in Appendix C of the Mercury PA as a Category I contributing element, indicating that it might be individually eligible for the NRHP. It is a historic property for the purposes of compliance with Section 106 of the National Historic Preservation Act (NHPA) and subject to the stipulations of the Mercury PA.

54 ENVIRONMENTAL SCIENCES↗

A semi-supervised learning method to produce explainable radioisotope proportion estimates for NaI-based synthetic and measured gamma spectra

Quantifying the radioactive sources present in gamma spectra is an ever-present and growing national security mission and a time-consuming process for human analysts. While machine learning models exist that are trained to estimate radioisotope proportions in gamma spectra, few address the eventual need to provide explanatory outputs beyond the estimation task. In this work, we develop two machine learning models for a NaI detector measurements: one to perform the estimation task, and the other to characterize the first model’s ability to provide reasonable estimates. To ensure the first model exhibits a behavior that can be characterized by the second model, the first model is trained using a custom, semi-supervised loss function which constrains proportion estimates to be explainable in terms of a spectral reconstruction. The second auxiliary model is an out-of-distribution detection function (a type of meta-model) leveraging the proportion estimates of the first model to identify when a spectrum is sufficiently unique from the training domain and thus is out-of-scope for the model. In demonstrating the efficacy of this approach, we encourage the use of meta-models to better explain ML outputs used in radiation detection and increase trust.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TinyTPC - A Test Stand for Photosensitive Dopants

Liquid argon time projection chambers (LArTPCs) are widely used to study accelerator neutrinos. Since LArTPCs are sensitive down to 10– 100 keV, neutrino experiments' physics programs could be extended to lower energies. However, in this scale, LArTPCs' energy resolution is significantly degraded because only charge is collected efficiently. One solution is the introduction of photosensitive dopants, which convert scintillation light to ionization yield. We have built a test stand (TinyTPC) with a LArPix pixelated anode plane and an active mass of 2.1 kg to study these charge enhancements. Our plan is to measure TinyTPC’s energy resolution with and without dopants using radioactive sources. This poster presentation will discuss TinyTPC's status and goals.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TinyTPC: A Test Stand for LAr Doping

TinyTPC is a small scale liquid-argon time projection chamber (LArTPC) featuring a pixelated readout system (LArPix) designed to improve the detection of charged particles. To enhance energy measurements at MeV scales, TinyTPC will study the impact of isobutylene, a photosensitive dopant that converts light to charge, and xenon, a wavelength shifter. This presentation will detail TinyTPC's commissioning, operation, data collection methodologies, noise levels, and upcoming tests involving isobutylene, xenon, and radioactive sources.

43 PARTICLE ACCELERATORS↗

The Future of X-ray Irradiation: Addressing Supply Chain Risks and Opportunities (UUR Edition)

This study supports the Office of Radiological Security’s (ORS) mission of eliminating cesium irradiators by analyzing the supply chain for self-shielded X-ray irradiators (SSXIs), identifying potential risks, and proposing mitigation measures. The research focuses on the primary components of SSXIs, including X-ray tubes, controllers, generators, and coolers or chillers, and evaluates their vulnerabilities using a comprehensive risk matrix framework. The methodology includes subject matter expert (SME) interviews with relevant manufacturers and major stakeholders, a deep literature review, and a meta-analysis of maintenance reports provided by SSXI end users. Results show that while the SSXI market is small, it’s growing, and the highly global nature of the supply chain may create vulnerabilities for critical SSXI components (X-ray tubes are the most vulnerable, followed by generators and controllers). This research communicates necessary information to address concerns of current and future end users, especially those interested in transitioning away from radioactive sources, and informs future policy aimed at supporting the irradiation industry.

07 ISOTOPE AND RADIATION SOURCES↗

Measurement of the gas gain and understanding the gas flow in the Mu2e Tracker

The Mu2e experiment will search for the charged-lepton flavor violating (CLFV) neutrinoless conversion of a negative muon into an electron in the field of an Aluminum nucleus µ − N → e − N. The signature of this process is the emission of a monochromatic electron with an energy of 104.97 MeV. The Mu2e Tracker is a low mass straw tube detector, whose aim is to measure the position and the momentum of the electron. In past measurements, high values of currents were found in some panels of the Tracker in absence of any radioactive sources. In this report new measurements of currents, that were taken with the panel MN084 of the Mu2e Tracker are described. Moreover, the addition of a small amount of water vapour in the gas mixture and the influence of the environmental conditions on the currents of the panel are studied.

47 OTHER INSTRUMENTATION↗

Tests of LBNF Beam Monitor Prototypes for the DUNE Experiment

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline on-axis neutrino oscillation experiment that will use a beam from the Long-Baseline Neutrino Facility (LBNF) to constrain the mixing angle $$\theta_{23}$, the neutrino mass hierarchy, and the CP violating phase $\delta_{CP}$. To ensure the beam remains on-axis, the LBNF beamline will employ two ionization chamber systems: the Hadron Alignment Detection System (HADeS) for primary beam alignment and the Muon Monitoring System (MuMS) for continuous beam monitoring and neutrino flux estimation. We have constructed prototypes for these systems at the University of Texas at Austin based on a design currently used in the NuMI hadron monitor. These prototypes were tested with a radioactive source and in beam tests at Fermilab's Irradiation Test Area. We present the results of these studies and discuss ongoing efforts to optimize the HADeS and MuMS designs.

Murthy, Chinmay↗

Results from the DUNE ND-LAr 2x2 Demonstrator Run 2

The Deep Underground Neutrino Experiment (DUNE) is a cutting-edge, long-baseline experiment under construction in the United States, based on large liquid-argon time projection chambers (LArTPCs). The DUNE Near Detector LArTPC (ND-LAr) will employ a novel modular architecture using a pixelated LArPix charge readout. To validate this design and characterize detector response, the 2×2 demonstrator—an array of eight optically isolated LArTPC modules—was deployed at Fermilab in 2024. During winter 2025, the 2x2 demonstrator was operated for a second data-taking campaign (Run 2) with the aim of studying the low-energy response of the detector. Run 2 focused on calibration and response studies using a suite of deployed radioactive sources. Gamma sources (²²Na, ⁶⁰Co, and ⁸⁸Y) were used to probe module-to-module performance variations, energy resolution, and calibrations. Neutron sources (AmBe and a pulsed neutron generator) enabled studies of neutron interactions in liquid argon, including inelastic scatters and neutron capture signals, relevant for low-energy backgrounds and detector modeling. In addition, the detector was doped with ²²⁰Rn, providing Bi–Po coincidence signals that allow precise calibration of the charge and scintillation response. This poster will present results from these calibration campaigns. These studies provide critical validation of the ND-LAr modular LArTPC concept and inform calibration and reconstruction strategies for the full DUNE near detector.

Mora-Lepin, Luis [Florida State U.] (ORCID:0000000↗

Novel Electron-Bubble Tracking Detectors

Our Columbia group, in collaboration with Brookhaven and SMU, has been carrying out R&D on tracking detectors in cryogenic liquids, including neon and helium. A cryostat purchased by this Grant capable of working temperatures down to 1 K and pressures above the critical point of neon and helium has been operated with a variety of noble fluids. Gaseous Electron Multipliers (GEM) with hydrogen additives have been operated with tracks of radioactive sources read out both by electrical charge detecting electronics, and an optical camera purchased by this Grant, measuring mobility, charge yield, transitions through phase boundaries, gain limitations, and other properties. The goal is very high resolution in large volumes. The scope of the project is the provision of a high performance camera and its installation in a cryogenic facility providing pressure up to 40 atmospheres and a temperature from ambient down to about 1 K. In this section we will address the goals and results having to do with this project and particularly the performance of the camera, and provide a summary of the status of the detector project. The technical development of digital cameras has been dominated for the last forty years by the Charge-Coupled Device technology (CCD). This allows photon recording on very small pixels on silicon planes that provide high quantum efficiency in the visible spectrum, recording the charge generated by a single photon stored on one pixel with an area of order ten microns square. The area can be up to several centimeters squared, containing a million pixels or more. The stores charge is usually read out by manipulating voltage biases to shift the charge in each pixel over to the next, and eventually out of the array and sent to an external processor and memory. Mass production has brought the cost per channel down to very small values and allowed cameras to be integrated to many consumer products. Thermal noise becomes larger than one photon on a single pixel at good temperature, and demand night vision and other demanding applications has led to intense R&D over the years, and small coolers that maintain the CCD at temperatures of more than 100K below ambient are integrated into the camera package. These systems are sold in quantity to amateur astronomers with the same silicon devices used in professional systems, provided long exposure times with less than one electron noise per pixel. In our particle readout, we are imaging a three-dimensional track drifting into the readout plane over time, and we need to read out one plane after another, and we need a high rate of pixel processing. For many years, the noise in the electronic amplifier matching the CCD to the external electronics led to noise levels of many electrons, much higher than in the CCD itself. A break-through was made by providing signal gain inside the CCD, connecting to the external line, by a Electron Multiplier CCD, using a number of electron avalanche stages, each with a small, stable gain. This device was brought out just before out application for the present Grant, provided the last link in the development chain, which allowed out optical readout concept to be implemented at reason fact. In fact, we profited from the falling cost by delaying our order for about a year, which, together with the university discount, allowed us to proceed within our budget. The camera we purchase from the firm ANDOR, which introduced the technique, comes with an extensive suite of software that allows the fast readout with different integration times, and makes a very convenient use in our application. We have been able to make images of the light signals coming from out GEM electron avalanche detectors under many conditions, with tracks of different particle types. We have reconfigured the system a number of times, using the results from the camera to learn how to change the TPC drift geometry and the GEM charge amplifier to improve performance, a process that is still going on. The camera purchase with this Grant has performed reliably and just as specified by the manufacturer and has been a trouble-free element of our larger product. The ability of being able to vary the pressure and temperature over a wide range is very important for several reasons: (1) we are able to choose a fluid density to make the best compromise between a range of low energy tracks long enough to measure, and higher density to minimize the detector size for a given rate; (2) we can identify the density the allows the avalanche rate that provides sufficient signal to noise for the low-energy tracks we need to measure in a given application; and (3) we can operate at the optimum density and hydrogen admixture for light production. A special cryostat was required to operate down to 1 K with pressures up to 40 Bar, well above the critical point of Neon.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗