RF Harmonic Kicker R&D Demonstration and Its Application to the RCS Injection of the EIC

The Rapid Cycling Synchrotron (RCS) of the Electron-Ion Collider (EIC) at Brookhaven National Laboratory (BNL) is an accelerating component of the electron injection complex, which provides polarized electrons in electron-ion collisions in the main Electron Storage Ring (ESR). We present the injection scheme into the RCS based on an ultra-fast harmonic kicker, whose "five odd-harmonic modes" prototype was developed in the context of the Jefferson Lab EIC (JLEIC) conceptual design. In its early stage of R&D, the sharp (~3 ns width) waveform construction, beam dynamics, and pulsed power operation with short ramping time (~10 us) will be discussed together with the fabrication work of the JLEIC prototype.

Park, G. -T.↗

Analysis of Low RRR SRF Cavities

Recent findings in the superconducting radio-frequency (SRF) community have shown that introducing certain impurities into high-purity niobium can improve quality factors and accelerating gradients. Success has been found in nitrogen-doping, diffusion of the native oxide into the niobium surface, and thin films of alternate superconductors atop a niobium bulk cavity. We question why some impurities improve RF performance while others hinder it. The purpose of this study is to characterize the impurity profile of niobium with a low residual resistance ratio (RRR) and correlate these impurities with the RF performance of low RRR cavities so that the mechanism of recent impurity-based improvements can be better understood and improved upon. Additionally, we perform a low temperature bake on the low RRR cavity to evaluate how the intentional addition of oxygen to the RF layer affects performance. We have found that low RRR cavities experience low temperature-dependent BCS resistance behavior more prominently than their high RRR counterparts. The results of this study have the potential to unlock a new understanding on SRF materials.

43 PARTICLE ACCELERATORS↗

Analysis of Low RRR SRF Cavities

Recent findings in the superconducting radio-frequency (SRF) community have shown that introducing certain impurities into high-purity niobium can improve quality factors and accelerating gradients. Success has been found in nitrogen-doping, diffusion of the native oxide into the niobium surface, and thin films of alternate superconductors atop a niobium bulk cavity. We question why some impurities improve RF performance while others hinder it. The purpose of this study is to characterize the impurity profile of niobium with a low residual resistance ratio (RRR) and correlate these impurities with the RF performance of low RRR cavities so that the mechanism of recent impurity-based improvements can be better understood and improved upon. Additionally, we performed surface treatments, low temperature baking and nitrogen-doping, on low RRR cavities to evaluate how the intentional addition of more impurities to the RF layer affects performance. We have found that low RRR cavities experience low temperature-dependent BCS resistance behavior more prominently than their high RRR counterparts. The results of this study have the potential to unlock a new understanding on SRF materials.

43 PARTICLE ACCELERATORS↗

Simulated Lorentz Force Detuning Compensation With A Double Lever Tuner On A Dressed ILC/1.3 GHZ Cavity At Room Temperature

Pulsed SRF linacs with high accelerating gradients experience large frequency shifts caused by Lorentz force detuning (LFD). A piezoelectric actuator with a resonance control algorithm can maintain the cavity frequency at the nominal level, thus reducing the RF power. This study uses a double lever tuner with a piezoelectric actuator for compensation and another piezoelectric actuator to simulate the effects of the Lorentz force pulse. A double lever tuner has an advantage by increasing the stiffness of the cavity-tuner system, thus reducing the impact of LFD. The tests are conducted at room temperature and with a dressed 1.3 GHz 9-cell cavity.

43 PARTICLE ACCELERATORS↗

Pressurized Gas Beam Monitor for Extremely High Intensities – Phase II

A novel pressurized gas-filled multi-RF-cavity beam profile monitor has been studied that is simple and robust in high-radiation environments. Charged particles passing through each RF-cavity in the monitor produce intensity-dependent ionized plasma, which changes the gas permittivity. Standard RF techniques to measure the change in quality factor (Q) and frequency (f) as a function of time are then used to determine the change in permittivity and corresponding beam intensity in each cavity in the profile monitor. The sensitivity to beam intensity is adjustable using gas pressure and RF gradient. The performance of the gas-filled beam profile monitor has been numerically simulated to evaluate the sensitivity of permittivity measurements and the effectiveness of calibration strategies. An entire multi-RF-cavity system has been designed and a demonstration test has been prepared.

43 PARTICLE ACCELERATORS↗

Electron beam emittance at operational intensity in fourth-generation synchrotron light sources

For synchrotron light sources, the brightness of user X-ray beams is primarily determined by the electron beam emittance and energy spread at operational intensity. A common feature of fourth-generation synchrotrons is the short length of electron bunches combined with a very small transverse beam size. Consequently, the particle density is much higher than in machines of previous generations, leading to strong collective effects that significantly increase the emittance and limit the achievable brightness at operational beam intensity. In this article, we summarize our studies of the emittance scaled with the beam energy and intensity, taking into account the effects of intrabeam scattering, beam-impedance interaction, and bunch lengthening provided by higher-harmonic RF systems, to identify optimal combinations of machine and beam parameters.

43 PARTICLE ACCELERATORS↗

Modeling for the phased injector upgrade for 12 GeV CEBAF

The upcoming Jefferson Lab K-Long experiment at Hall D will require unique beam conditions with a much lower bunch repetition rate and atypically high bunch charge. To optimize the Continuous Electron Beam Accelerator Facility (CEBAF) injector for this experiment, we performed Multi-Objective Genetic Optimization (MGO) using General Particle Tracer (GPT) to determine the magnetic elements and RF settings necessary for the K-long bunch charge (0.64 pC) at 200 kV. We also investigated the transmission and beam characteristics of low to high charge per bunch electron beams through the injector for simultaneous operations of all four CEBAF Halls and characterized the transmission as a function of the photocathode laser spot size and pulse length. Our findings provide valuable insights into optimizing the CEBAF injector for the Jefferson Lab K-Long experiment, as well as for other experiments with similar beam conditions

Kazimi, R.↗

Nb3Sn Superconducting Cavity Developments for Heavy-ion Beams

Nb3Sn has been identified as the most promising next-generation superconducting material for accelerator cavities. This is due to the higher critical temperature (Tc = 18 K) of Nb3Sn compared to niobium (Tc = 9.2 K), which leads to greatly reduced RF losses in the cavity during 4.5 K operation. This allows two important changes during cavity and cryomodule design. First, the higher Tc leads to negligible BCS losses when operated at 4.5 K, which allows for a higher frequency to be used, translating to significantly smaller cavities and cryomodules. Second, the reduced dissipated power lowers the required cryogenic cooling capacity, meaning that cavities can feasibly be operated on 5-10 W cryocoolers instead of a centralized helium refrigeration plant. These plants and distribution systems are costly and complex, requiring skilled technicians for operation and maintenance. These fundamental changes present an opportunity for a paradigm shift in how low-beta linacs are designed and operated. Fabrication and testing results of first prototypes are discussed.

Petersen, T. [Argonne]↗

SRF cavity instability detection with machine learning at CEBAF

During the operation of the Continuous Electron Beam Accelerator Facility (CEBAF), one or more unstable superconducting radio-frequency (SRF) cavities often cause beam loss trips while the unstable cavities themselves do not necessarily trip off. The present RF controls for the legacy cavities report at only 1 Hz, which is too slow to detectfast transient instabilities during these trip events. These challenges make the identification of an unstable cavity out of the hundreds installed at CEBAF a difficult and time-consuming task. To tackle these issues, a fast data acquisition system (DAQ) for the legacy SRF cavities has been developed, which records the sample at 5 kHz. An unsupervised learning framework has been developed to identify anomalous SRF cavity behavior. We will discuss the present status of the DAQ system and our framework, along with recent successes in detecting anomalous cavity behavior. Overall, our method offers a practical solution for identifying unstable SRF cavities, contributing to increased beam availability and machine reliability.

Accelerator Physics↗

Magnetic field mapping of superconducting radio frequency cavities

Superconducting radio frequency (SRF) cavities are the fundamental building blocks of modern particle accelerators. Niobium is the material of choice to build such cavities. These cavities require a cryogenic cool-down to ~2 ? 4 K for optimum performance minimizing RF losses on the inner cavity surface. However, temperature-independent residual losses in SRF cavities cannot be prevented entirely. One of the major sources of residual losses is trapped magnetic flux. The flux trapping mechanism depends on different factors, such as surface preparations and cool-down conditions. We have developed a diagnostic magnetic field scanning system (MFSS) using Hall probes and anisotropic magneto-resistance sensors to study the spatial distribution of trapped flux in 1.3 GHz single-cell cavities. The first result from this newly commissioned system revealed that the trapped flux on the cavity surface might redistribute with increasing RF power. The MFSS was also able to capture significant magnetic field enhancement at specific cavity locations after a quench.

Parajuli, Ishwari↗

Accelerating cavity fault prediction using deep learning at Jefferson Laboratory

Abstract Accelerating cavities are an integral part of the continuous electron beam accelerator facility (CEBAF) at Jefferson Laboratory. When any of the over 400 cavities in CEBAF experiences a fault, it disrupts beam delivery to experimental user halls. In this study, we propose the use of a deep learning model to predict slowly developing cavity faults. By utilizing pre-fault signals, we train a long short-term memory-convolutional neural network binary classifier to distinguish between radio-frequency (RF) signals during normal operation and RF signals indicative of impending faults. We optimize the model by adjusting the fault confidence threshold and implementing a multiple consecutive window criterion to identify fault events, ensuring a low false positive rate. Results obtained from analysis of a real dataset collected from the accelerating cavities simulating a deployed scenario demonstrate the model’s ability to identify normal signals with 99.99% accuracy and correctly predict 80% of slowly developing faults. Notably, these achievements were achieved in the context of a highly imbalanced dataset, and fault predictions were made several hundred milliseconds before the onset of the fault. Anticipating faults enables preemptive measures to improve operational efficiency by preventing or mitigating their occurrence.

43 PARTICLE ACCELERATORS↗

HIGHLY-EFFICIENT 20-MW L-BAND MULTI-BEAM KLYSTRON

The overall goal of this project was to develop and demonstrate a novel two-stage multi-beam klystron (TS-MBK) for use in accelerator, medical, national security, medical, and environmental cleanup applications. The novelties embodied in the TS-MBK design include use of hollow beams to obtain strong coupling to cavities, and post acceleration after bunching to reduce the beam’s energy spread to allow an exceptional electronic efficiency that we predict can reach 90%. During Phase I of this project, Omega-P R&D refined its conceptual design of the 1.0 GHz TS-MBK, and collector design and cooling requirements for several levels of average power output. If, as was the case, it turned out that estimated costs for fabrication and testing of a full 12-beam TS-MBK prototype would exceed available Phase II funding, our Plan-B would have be adopted. In it, a single-beam version would have been designed and built, with all specifications identical to the 12-beam version, except that the average power level would be reduced by a factor of about 12. This one-beam version would still allow evaluation of the efficacy of our design concept for implementing two stages, including prevention of radiation loss at the HV gap, and for demonstrating the predicted 90% electronic efficiency and the absence of reflected electrons from the collector reaching the cathodes. But the absence of the expected industrial partner in further development of this novel RF source made it impractical for advancing the project into Phase II.

43 PARTICLE ACCELERATORS↗

Characterization of transverse electron pulse trains using RF powered traveling wave metallic comb striplines

Advancements in ultrafast electron microscopy have allowed elucidation of spatially selective structural dynamics. However, as the spatial resolution and imaging capabilities have made progress, quantitative characterization of the electron pulse trains has not been reported at the same rate. In fact, inexperienced users have difficulty replicating the technique because only a few dedicated microscopes have been characterized thoroughly. Systems replacing laser driven photoexcitation with electrically driven deflectors especially suffer from a lack of quantified characterization because of the limited quantity. The primary advantages to electrically driven systems are broader frequency ranges, ease of use and simple synchronization to electrical pumping. Here, we characterize the technical parameters for electrically driven UEM including the shape, size and duration of the electron pulses using low and high frequency chopping methods. At high frequencies, pulses are generated by sweeping the electron beam across a chopping aperture. For low frequencies, the beam is continuously forced off the optic axis by a DC potential, then momentarily aligned by a countering pulse. Using both methods, we present examples that measure probe durations of 2 ns and 10 ps for the low and high frequency techniques, respectively. Here, we also discuss how the implementation of a pulsed probe affects STEM imaging conditions by adjusting the first condenser lens.

36 MATERIALS SCIENCE↗

Multi-metallic conduction cooled superconducting radio-frequency cavity with high thermal stability

Superconducting radio-frequency cavities are commonly used in modern particle accelerators for applied and fundamental research. Such cavities are typically made of high-purity, bulk Nb and with cooling by a liquid helium bath at a temperature of ~2 K. The size, cost and complexity of operating a particle accelerator with a liquid helium refrigerator make the current cavity technology not favorable for use in industrial-type accelerators. We have developed a multi-metallic 1.495 GHz elliptical cavity conductively cooled by a cryocooler. The cavity has a ~2 µm thick layer of Nb 3 Sn on the inner surface, exposed to the rf field, deposited on a ~3 mm thick bulk Nb shell and a bulk Cu shell, of thickness $\geqslant\! 5$ mm deposited on the outer surface by electroplating. A bolt-on Cu plate 1.27 cm thick was used to thermally connect the cavity equator to the second stage of a Gifford-McMahon cryocooler with a nominal capacity of 2 W at 4.2 K. The cavity was tested initially in liquid helium at 4.3 K and reached a peak surface magnetic field of ~36 mT with a quality factor of 2 × 10 9 . The cavity cooled by the cryocooler achieved a peak surface magnetic field of ~29 mT, equivalent to an accelerating gradient of 6.5 MV m –1 . The conduction-cooled cavity could be operated in continuous-wave with as high as 5 W dissipation in the cavity for 1 h without any thermal breakdown, because of the Cu outer layer with high thermal conductivity. This result represents a paradigm shift in the technology of superconducting accelerator cavities.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

EUV FEL light source based on energy recovery linac with on-orbit laser plasma injection

We report on a week-long study of a conceptual design of EUV FEL light source based on an energy recovery linac with on-orbit laser plasma accelerator injection scheme. We carried out this study during USPAS Summer 2023 session of Unifying Physics of Accelerators, Lasers and Plasma applying the art of inventiveness TRIZ. An ultrashort Ti-sapphire laser accelerates electron beams from a gas target with mean energy of 20 MeV, which are then ramped up to 1 GeV in a five-turn scheme with a series of fixed field alternating magnets and two superconducting RF cavities (100 MeV per cavity per turn). The electron beam is then bypassed to an undulator line optimized to generate EUV light of 13.5 nm at kW level in a single pass.

43 PARTICLE ACCELERATORS↗

Harmonic Slip-Stacking

Particle accelerators employ slip-stacking configurations to store two particle beams with disparate momenta within a single ring. Additionally, A novel slip-stacking configuration employing a harmonic RF cavity was proposed and studied. Anticipated benefits of the harmonic cavity include mitigating parametric resonances, minimizing emittance growth, and significantly expanding the stable longitudinal phase-space area. By surpassing the requirements of PIP-II operation, the harmonic RF cavity will support extending slip-stacking operation for subsequent beam power upgrades of Main Injector, including a proposed cycle rate improvement. Our ongoing research will verify the simulation of harmonic slip-stacking (HSS) operation under RF phase-errors, such as those causes by beam-loading effects.

Habibeh, Mohammad↗