Search NASA⌕ Search

SEARCH · Search NASA

Results for “ROOFS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Quantum computing approach for building surface sunlit in urban-scale energy modeling

Solar shadow calculations are needed in building energy modeling and performance simulation of PV systems installed on roofs or facades of buildings. We present a quantum computing approach for calculation of building surface sunlit fractions by recasting solar visibility as a binary optimization problem solved by quantum annealing. Each triangulated surface centroid is encoded as a binary qubit indicating sunlit or shaded status. Geometric visibility constraints are derived from the Möller-Trumbore intersection algorithm and converted into a constrained quadratic binary model compatible with contemporary quantum annealers. The coefficients were embedded to D-Wave quantum computer. To demonstrate feasibility, we conducted a case study in San Francisco for a target building with 52 triangles and roughly 2700 nearby triangles within 50 m evaluated at representative winter and summer solar positions. The results demonstrated that quantum annealing can reliably calculate and distinguish sunlit from shaded surfaces. Quantum samples achieved average accuracy exceeding 92.4 %, with the aggregate surface-level agreement approaching 99.9 %. The outputs of quantum computers agreed closely with classical algorithms, indicating practical feasibility and promising scalability. Finally, the hourly sunlit fractions of building surfaces can be obtained for urban energy modelling. This is the first study to apply quantum computing to the solar shadow and building surface sunlit calculation. It introduces a new paradigm that differs fundamentally from traditional approaches.

Deng, Zhipeng↗

Improving energy efficiency while reducing anthropogenic heat from buildings: how retrofits influence the building stock and urban microclimate in Los Angeles

Anthropogenic heat (AH) from buildings contributes to urban overheating, especially during heat waves, yet building retrofit studies usually evaluate energy savings without assessing impacts on AH. This study quantifies how common building retrofit measures affect both building energy use and AH emissions across the City of Los Angeles. Using a bottom-up urban building energy modeling framework coupled with high-resolution local weather from the Weather Research and Forecasting model with Building Effect Parameterization (WRF-BEP), we evaluate eleven retrofit measures and two multi-measure retrofit packages. HVAC and LED lighting retrofits provide the largest city-wide annual site energy savings, while roof coating is most effective for reducing AH. A package optimized for energy savings reduces summer site energy use by about 32% (2.3 TWh), while a package incorporating AH-focused measures reduces the total AH by over 50% (137 PJ) with minimal difference in energy savings. The AH-aware package produces substantially greater urban cooling, reducing mean near-surface air temperature by up to 0.62 ℃ and peak temperature by up to 3.79 ℃. These results show that retrofit strategies selected only for energy savings may overlook major opportunities for urban heat mitigation. The study provides a framework for integrating AH into building retrofit planning and urban heat resilience policy.

Anthropogenic heat↗

New trends in solar: A comparative study assessing the attitudes towards the adoption of rooftop PV

The factors affecting the adoption of conventional solar PV have been broadly addressed in the recent literature. However, it is still to determine the public's acceptance of innovations of the traditional solar PV architecture. Building applied photovoltaic technology (BAPV) is a technological innovation that can be installed over existing building surfaces. This study compares an evaluation of the conscious and subconscious attitudinal, control and normative beliefs of American homeowners when randomly primed with two brochures depicting the purchasing, installation, and commissioning of solar PV systems, developed according to the characteristics of conventional and an adhesive “plug and play” BAPV system. The survey instrument (N = 400 survey participants) was designed in consonance to the Theory of Planned Behavior (TPB). When comparing the direct measures for each solar PV technology, no significant differences were found. This may indicate that for those unfamiliar with PV technology, placing an adhesive backing module on the roof is standard procedure and does not impact purchasing intentions. The evaluation further showed that unlike the subconscious control beliefs, social norms and attitudes have a significant impact on forming intentions to adopt solar PV. The implications of these findings for strategy, policy and future research are explored.

14 SOLAR ENERGY↗

Addressing the soft cost challenge in U.S. small-scale solar PV system pricing

Solar photovoltaic (PV) prices have fallen significantly over the past two decades. These price reductions have relied primarily on falling system hardware costs. Future reductions in PV prices - which are needed to ensure that enough PV will be deployed to meet global clean energy objectives - will require reductions in non-hardware or 'soft' costs, particularly in markets with relatively high soft costs such as the United States. In this article, we draw insights from the literature on which factors affect soft costs for small-scale PV systems in the United States. The literature shows that soft costs tend to be lower for systems that are larger, installed during new construction, installed by more experienced installers, installed in more concentrated markets and in more competitive markets, installed in markets where customers receive more quotes, or installed in markets with less onerous permitting requirements. We identify three marketplace design strategies that policymakers could pursue to address the soft cost challenge in the United States and similar markets: encourage the expansion of quote platforms; encourage or require that PV system installation be integrated into the new construction and roof replacement process; and encourage the expansion of customer aggregation models such as Solarize campaigns and community solar.

14 SOLAR ENERGY↗

A review of challenges, barriers, and opportunities for large-scale deployment of cool surfaces

Major urban centers are warming due to a combination of global and local phenomena. City governments are increasingly adopting strategies to mitigate the causes and impacts of extreme heat on their populations. Among these strategies are high solar-reflectance (cool) surfaces installed on building roofs and walls. Use of cool surfaces is a cost-effective and simple strategy that replaces conventional darker surfaces with surfaces that have a high reflectance to shortwave (solar) energy. This report reviews the recent history of cool-surface deployment efforts. This includes peer-reviewed literature, conference proceedings, and grey literature to identify challenges and barriers to wide-scale deployment of cool surfaces. We have also researched heat action plans and programs from cities and different codes and standards, as well as available incentive and rebate programs. The review identifies challenges, barriers, and opportunities associated with large-scale deployment of cool surfaces and categorize them broadly as being related to product development & performance or policies & mandates. It provides a foundation upon which we intend to build a roadmap for rapidly accelerating future deployments of cool surfaces. Finally, this roadmap will address identified challenges and incorporate lessons learned from historical efforts to generate a practical and actionable plan.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of flammable volume in the case of a catastrophic leak of R-32 from a rooftop unit

With the effort to use alternative refrigerants with lower global warming potential (GWP), the majority of these alternative refrigerants are classified as slightly flammable. Here in this paper we report on the numerical evaluation of a catastrophic leak scenario of R-32 refrigerant from a 3-ton roof top air conditioning unit (RTU) which serves a 12.2 × 9.14 × 2.4 m room. A full rupture of a 6.35 mm (¼ inch) pipe downstream of the evaporator coil is simulated. Two separate cases with refrigerant releases of 1.81 kg and 3.62 kg charge have been studied. The two charges are released in 10.2 and 20.4 s, respectively, just after the end of a unit cooling cycle. The flammable volume inside the room existed only for about 40 s with a maximum flammable volume inside the room of 1.12% of the total room volume for the 3.62 kg charge case.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Printable, emissivity-adaptive and albedo-optimized covering for year-round energy saving

Radiative cooling uses high-emissivity materials to passively cool the surface of outdoor objects, such as building roofs on hot days. The issue of overcooling with this technology on cold days can be addressed by structures with thermal emissivity that is adaptive to temperature. Despite recent advances in temperature-adaptive structures, great challenges remain in their fabrication feasibility and unoptimized solar heating that may override the radiative cooling benefit. Here, in this work, we develop a printable, emissivity-adaptive and albedo-optimized covering (PEAC) based on recyclable materials with roll-to-roll fabrication. A PEAC automatically switches its sky-window emissivity from 0.25 to 0.85 when the surface temperature exceeds a pre-set transition temperature, delivering an albedo optimized for maximal year-round energy saving or thermal comfort in a given climate.

36 MATERIALS SCIENCE↗

Energy savings and cost-benefit analysis of the new commercial building standard in China

In this study, a comprehensive comparison of the commercial building energy efficiency standard between the previous 2005 version and the new proposed version is conducted, including the energy efficiency analysis and cost-benefit analysis. To better understand the tech-economic performance of the new Chinese standard, energy models were set up based on a typical commercial office building in Chinese climate zones. The building energy standard in 2005 is used as the baseline for this analysis. Key building technologies measures are analyzed individually, including roof, wall, window, lighting and chiller and so on and finally whole building cost-benefit analysis was conducted. Results show that the new commercial building energy standard demonstrates good cost-effective performance, with whole building payback period around 4 years.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Economic and environmental feasibility of recycling flexible plastic packaging from single stream collection

As demand for plastic increases, there is an urgent need to ramp up its collection and recycling rate. This study reports results of a pilot study in the United States to recycle flexible plastic packaging (FPP) from single stream curbside collection focusing on both the economic feasibility and carbon footprint. To explore the marketability of recycled FPP, four down-stream market pathways were studied, including roof coverboard, plastic pellets, pallets, and film. In this work, results indicated that (1) the cleaning and pelletizing process at reclaimers contributed the most to the total greenhouse gas (GHG) emissions of recycled FPP products, and (2) the GHG emissions of recycled FPP products in all four pathways are lower than the comparator products. Therefore, using a higher percentage of recycled FPP substituted in a product can result in greater GHG emission reductions. All the recycled FPP products also showed favorable economics compared to their direct competitors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Methodology for Estimating Solar Potential on Multiple Building Rooftops for Photovoltaic Systems

In this paper, a methodology for estimating solar potential on multiple building rooftops is presented. The objective of this methodology is to estimate the daily or monthly solar radiation potential on individual buildings in a city/region using Light Detection and Ranging (LiDAR) data and a geographic information system (GIS) approach. Conceptually, the methodology is based on the upward-looking hemispherical viewshed algorithm, but applied using an area-based modeling approach. The methodology considers input parameters, such as surface orientation, shadowing effect, elevation, and atmospheric conditions, that influence solar intensity on the earth s surface. The methodology has been implemented for some 212,000 buildings in Knox County, Tennessee, USA. Based on the results obtained, the methodology seems to be adequate for estimating solar radiation on multiple building rooftops. The use of LiDAR data improves the radiation potential estimates in terms of the model predictive error and the spatial pattern of the model outputs. This methodology could help cities/regions interested in sustainable projects to quickly identify buildings with higher potentials for roof-mounted photovoltaic systems.

14 SOLAR ENERGY↗

Connecting the resource nexus to basic urban service provision – with a focus on water-energy interactions in New York City

Urban water and energy systems are crucial for sustainably meeting basic service demands in cities. Therefore, this paper proposes and applies a technology-independent “reference resource-to-service system” framework for concurrent evaluation of urban water and energy system interventions and their ‘nexus’ or ‘interlinkages’. In a concrete application, data that approximate New York City conditions are used to evaluate a limited set of interventions in the residential sector, spanning from low-flow toilet shifts to extensive green roof installations. Results indicate that interventions motivated primarily by water management goals can considerably reduce energy use and contribute to mitigation of greenhouse gas emissions. Similarly, energy efficiency interventions can considerably reduce water use in addition to lowering emissions. However, interventions yielding the greatest reductions in energy use and emissions are not necessarily the most water conserving ones, and vice versa. Useful further research, expanding the present analysis should consider a broader set of resource interactions, towards a full climate, land, energy and water (CLEW) nexus approach. Overall, assessing the impacts, trade-offs and co-benefits from interventions in one urban resource system on others also holds promise as support for increased resource efficiency through integrated decision making.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Hybrid photovoltaic/thermal (PV/T) solar systems simulation with Simulink/Matlab

The purpose of this work consists in thermodynamic modeling of hybrid photovoltaic-thermal (PV/T) solar systems, pursuing a modular strategy approach provided by Simulink/Matlab. PV/T solar systems are a recently emerging solar technology that allows for the simultaneous conversion of solar energy into both electricity and heat. This type of technology present some interesting advantages over the conventional ''side-by-side'' thermal and PV solar systems, such as higher combined electrical/thermal energy outputs per unit area, and a more uniform and aesthetical pleasant roof area. Despite the fact that early research on PV/T systems can be traced back to the seventies, only recently it has gained a renewed impetus. In this work, parametric studies and annual transient simulations of PV/T systems are undertaken in Simulink/Matlab. The obtained results show an average annual solar fraction of 67%, and a global overall efficiency of 24% (i.e. 15% thermal and 9% electrical), for a typical four-person single-family residence in Lisbon, with p-Si cells, and a collector area of 6 m{sup 2}. A sensitivity analysis performed on the PV/T collector suggests that the most important variable that should be addressed to improve thermal performance is the photovoltaic (PV) module emittance. Based on those results, some additional improvements are proposed, such as the use of vacuum, or a noble gas at low-pressure, to allow for the removal of PV cells encapsulation without air oxidation and degradation, and thus reducing the PV module emittance. Preliminary results show that this option allows for an 8% increase on optical thermal efficiency, and a substantial reduction of thermal losses, suggesting the possibility of working at higher fluid temperatures. The higher working temperatures negative effect in electrical efficiency was negligible, due to compensation by improved optical properties. The simulation results are compared with experimental data obtained from other authors and perform reasonably well. The Simulink modeling platform has been mainly used worldwide on simulation of control systems, digital signal processing and electric circuits, but there are very few examples of application to solar energy systems modeling. This work uses the modular environment of Simulink/Matlab to model individual PV/T system components, and to assemble the entire installation layout. The results show that the modular approach strategy provided by Matlab/Simulink environment is applicable to solar systems modeling, providing good code scalability, faster developing time, and simpler integration with external computational tools, when compared with traditional imperative-oriented programming languages. (author)

14 SOLAR ENERGY↗

Lighting and visual comfort performance of commercially available tubular daylight devices

Tubular daylight devices (TDDs) require a much smaller roof opening than conventional skylights and, because of their highly reflective tube, they can deliver daylight farther away from the building envelope. This can provide lighting energy savings, increasing resilience in new and existing buildings. Different types and configurations are available amongst commercially available TDDs, including domes/diffusers with varying optical properties and the diameter of the TDD. This paper presents a comprehensive experimental evaluation of the lighting and visual comfort performance of multiple configurations of commercially available TDDs, varying dome type (prismatic and clear), diffuser type (Fresnel and prismatic), and diameter (53 and 35 cm), under a range of environmental conditions (different times of day/year, sky cover). Based on illuminance measurements, estimated lighting energy use is also presented. Results indicate that, for clear sky, light levels increase and energy use decreases with solar altitude (e.g., 16 Wh/m 2 daily energy use intensity on a high maximum daily solar altitude (MDSA) day and 34 Wh/m 2 on a low MDSA day) and TDD diameter (e.g., 34 Wh/m 2 and 69 Wh/m 2 for 53 cm and 35 cm TDDs, respectively, for low MDSA). The daily illuminance profile is more rounded for prismatic domes and has higher peaks for clear domes; this translates into a somewhat higher average daily useful daylight illuminance (DUDI) for prismatic domes (86 %) when compared to clear domes (80 %). No clear impact of diffuser type was apparent. In conclusion, measurements indicated no discomfort glare for any of the conditions tested.

14 SOLAR ENERGY↗

Comparing land surface temperature and mean radiant temperature for urban heat mapping in Philadelphia

Many cities are experiencing more frequent extreme heat during hot summers. With the rise of global temperature, the thermal comfort in urban areas become even worse. Quantitative information of the spatial distributions of urban heat has become increasingly important for resilience and adaptation to climate change in cities. This study compares satellite-derived land surface temperature (LST) and urban microclimate modeling-based mean radiant temperature (Tmrt) for mapping the urban heat distributions in Philadelphia, Pennsylvania, USA. Here, the LST was estimated based on Landsat 8 thermal imagery with a spatial resolution of around 100 m, while the Tmrt was simulated based on high resolution LiDAR and national aerial imagery program multispectral aerial imageries with a spatial resolution of 1 m. Result shows that both LST and Tmrt show a similar general pattern of the urban heat across the study area, while the Tmrt presents much more details of the heat variations street by street and neighborhood by neighborhood. The LST tends to have a stronger relationship with the Tmrt on building roofs, which are usually not the place for human activities. This studyprovides evidence for choosing more appropriate metrics in urban heat-related studies.

54 ENVIRONMENTAL SCIENCES↗

Construction materials as a waste management solution for cellulose sludge

Sustainable waste management system for effluents treatment sludge has been a pressing issue for pulp and paper sector. Recycling is always recommended in terms of environmental sustainability. Following an approach of waste valorisation, this work aims to demonstrate the technical viability of producing fiber-cement roof sheets incorporating cellulose primary sludge generated on paper and pulp mills. From the results obtained with preliminary studies it was possible to verify the possibility of producing fiber-cement sheets by replacing 25% of the conventional used virgin long fiber by primary effluent treatment cellulose sludge. This amount of incorporation was tested on an industrial scale. Environmental parameters related to water and waste, as well as tests for checking the quality of the final product was performed. These control parameters involved total solids in suspension, dissolved salts, chlorides, sulphates, COD, metals content. In the product, parameters like moisture, density and strength were controlled. The results showed that it is possible to replace the virgin long fibers pulp by primary sludge without impacts in final product characteristics and on the environment. This work ensures the elimination of significant waste amounts, which are nowadays sent to landfill, as well as reduces costs associated with the standard raw materials use in the fiber-cement industrial sector.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radiative cooling and thermoregulation in the earth’s glow

Efficient passive radiative cooling of buildings requires an unimpeded view of the sky. However, vertical facades of buildings mostly see terrestrial features that become broadband-radiative heat sources in the summer and heat sinks in the winter. The resulting summertime terrestrial heat gain by buildings negates or overwhelms their narrowband longwave infrared (LWIR) radiative cooling to space, while the wintertime terrestrial heat loss causes overcooling. We show that selective LWIR emitters on vertical building facades can exploit the differential transmittance of the atmosphere toward the sky and between terrestrial objects to achieve higher summertime cooling and wintertime heating than conventionally used broadband emitters. The impact of this novel and passive thermoregulation is comparable to that of painting dark roofs white and is achievable with both novel and commonplace materials. Our findings represent new and remarkable opportunities for materials design and untapped thermoregulation of entities ranging from buildings to human bodies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Structural Uncertainty in the Sensitivity of Urban Temperatures to Anthropogenic Heat Flux

One key source of uncertainty for weather and climate models is structural uncertainty arising from the fact that these models must simplify or approximate complex physical, chemical, and biological processes that occur in the real world. However, structural uncertainty is rarely examined in the context of simulated effects of anthropogenic heat flux in cities. Using the Weather Research and Forecasting (WRF) model coupled with a single-layer urban canopy model, it is found that the sensitivity of urban canopy air temperature to anthropogenic heat flux can differ by an order of magnitude depending on how anthropogenic heat flux is released to the urban environment. Moreover, varying model structures through changing the treatment of roof-air interaction and the parameterization of convective heat transfer between the canopy air and the atmosphere can affect the sensitivity of urban canopy air temperature by a factor of 4. Urban surface temperature and 2-m air temperature are less sensitive to the methods of anthropogenic heat flux release and the examined model structural variants than urban canopy air temperature, but their sensitivities to anthropogenic heat flux can still vary by as much as a factor of 4 for surface temperature and 2 for 2-m air temperature. Our study recommends using temperature sensitivity instead of temperature response to understand how various physical processes (and their representations in numerical models) modulate the simulated effects of anthropogenic heat flux.

54 ENVIRONMENTAL SCIENCES↗