Search NASA⌕ Search

SEARCH · Search NASA

Results for “SAMPLE POSITIONING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Deep Dielectric Charging of Spacecraft Polymers by Energetic Protons

The majority of research in the field of spacecraft charging concentrates on electron charging effects with little discussion of charging by protons. For spacecraft orbiting in the traditional LEO and GEO environments this emphasis on electrons is appropriate since energetic electrons are the dominant species in those orbits. But for spacecraft in orbits within the inner radiation belts or for interplanetary and lunar space probes, proton charging (center dot) effects may also be of concern. To examine bulk spacecraft charging effects in these environments several typical highly insulating spacecraft polymers were exposed to energetic protons (center dot) with energies from 1 Me V to lO Me V to simulate protons from the solar wind and from solar energetic proton events. Results indicate that effects in proton charged dielectrics are distinctly different than those observed due to electron charging. In most cases, the positive surface potential continued to increase for periods on the order of minutes to a day, followed by long time scale decay at rates similar to those observed for electron charging. All samples charged to positive potentials with substantially lower magnitudes than for equivalent electron doses. Possible explanations for the different behavior of the measured surface potentials from proton irradiation are discussed; these are related to the evolving internal charge distribution from energy dependent electron and proton transport, electron emission, charge migration due to dark current and radiation induced conductivity, and electron capture by embedded protons.

radiation induced conductivity↗

Diagnosing and Correcting Mass Accuracy and Signal Intensity Error Due to Initial Ion Position Variations in a MALDI TOFMS

Frustrated by worse than expected error for both peak area and time-of-flight (TOF) in matrix assisted laser desorption ionization (MALDI) experiments using samples prepared by electrospray deposition, it was finally determined that there was a correlation between sample location on the target plate and the measured TOF/peak area. Variations in both TOF and peak area were found to be due to small differences in the initial position of ions formed in the source region of the TOF mass spectrometer. These differences arise largely from misalignment of the instrument sample stage, with a smaller contribution arising from the non-ideal shape of the target plates used. By physically measuring the target plates used and comparing TOF data collected from three different instruments, an estimate of the magnitude and direction of the sample stage misalignment was determined for each of the instruments. A correction method was developed to correct the TOFs and peak areas obtained for a given combination of target plate and instrument. Two correction factors are determined, one by initially collecting spectra from each sample position used and another by using spectra from a single position for each set of samples on a target plate. For TOF and mass values, use of the correction factor reduced the error by a factor of 4, with the relative standard deviation (RSD) of the corrected masses being reduced to 12-24 ppm. For the peak areas, the RSD was reduced from 28% to 16% for samples deposited twice onto two target plates over two days. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reversal electron attachment ionizer for detection of trace species

An in-line reversal electron, high-current ionizer capable of focusing a beam of electrons to a reversal region and executing a reversal of the electrons, such that the electrons possess zero kinetic energy at the point of reversal, may be used to produce both negative and positive ions. A sample gas is introduced at the point of electron reversal for low energy electron-(sample gas) molecule attachment with high efficiency. The attachment process produces negative ions from the sample gas, which includes species present in trace (minute) amounts. These ions are extracted efficiently and directed to a mass analyzer where they may be detected and identified. The generation and detection of positive ions is accomplished in a similar fashion with minimal adjustment to potentials applied to the apparatus.

Bernius, Mark T.↗

Reversal electron attachment ionizer for detection of trace species

An in-line reversal electron, high-current ionizer capable of focusing a beam of electrons to a reversal region and executing a reversal of said electrons, such that the electrons possess zero kinetic energy at the point of reversal, may be used to produce both negative and positive ions. A sample gas is introduced at the point of electron reversal for low energy electron-(sample gas) molecule attachment with high efficiency. The attachment process produces negative ions from the sample gas, which includes species present in trace (minute) amounts. These ions are extracted efficiently and directed to a mass analyzer where they may be detected and identified. The generation and detection of positive ions is accomplished in a similar fashion with minimal adjustment to potentials applied to the apparatus.

Bernius, Mark T.↗

One-shot spectrometer for several elements using an integrated conical crystal analyzer

Time-resolved x-ray spectrometry using an ultrastrong x-ray source such as an x-ray free electron laser is one of the new trends in the field of x-ray physics. To achieve such time-resolved measurement, the development of an one-shot spectrometer with a wide wavelength range, high efficiency, and good energy resolution is an essential prerequisite. Here we developed an integrated conical Ge crystal analyzer consisting of several conical rings, which were connected using spline surfaces to form a single body using our previously developed hot deformation technique, which can form a Si or Ge wafer into an arbitrary and accurate shape. We simultaneously focused several characteristic lines from an alloy sample onto different positions on a small x-ray charge-coupled device with very high image brightness (gain relative to planar analyzer: 100) and a good spatial resolution of 9-13 eV. The small radius of curvature of the crystal (28-50 mm) enabled us to realize a very short sample-detector distance of 214.4 mm. The present result shows the possibility of realizing a new focusing x-ray crystal spectrograph that can control the focal position as desired.

43 PARTICLE ACCELERATORS↗

The effect of exit beam phase aberrations on parallel beam coherent x-ray reconstructions

Diffraction artifacts from imperfect x-ray windows near the sample are an important consideration in the design of coherent x-ray diffraction measurements. In this study, we used simulated and experimental diffraction patterns in two and three dimensions to explore the effect of phase imperfections in a beryllium window (such as a void or inclusion) on the convergence behavior of phasing algorithms and on the ultimate reconstruction. A predictive relationship between beam wavelength, sample size, and window position was derived to explain the dependence of reconstruction quality on beryllium defect size. Defects corresponding to this prediction cause the most damage to the sample exit wave and induce signature error oscillations during phasing that can be used as a fingerprint of experimental x-ray window artifacts. The relationship between x-ray window imperfection size and coherent x-ray diffractive imaging reconstruction quality explored in this work can play an important role in designing high-resolution in situ coherent imaging instrumentation and will help interpret the phasing behavior of coherent diffraction measured in these in situ environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Influence of Pinning Centers in the Magnetization of the Mesoscopic Superconductors

In this work, we study the mesoscopic superconducting samples with pinning centers using the time-dependent Ginzburg-Landau theory (TDGL). The pinning centers are introduced via the phenomenological function f(r) Sorensen et al. (Physica C 533, 40–43 2017). We calculated the magnetization curves M(H) for some distances d from the boundary of the sample to the position of the pinning center. From this investigation arises the relation between the first magnetic field H{sub p} and the distance d. It shows that the pinning centers located close to the boundary of the sample decrease H{sub p}, and also the existence of two regimes of the penetration of the vortices. The magnetization curves revel the existence of ruddle of jumps for low magnetic fields for small distances d, indicating a complex vortex penetration.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Novel Method for Phasor Measurement Unit Sampling Time Error Compensation

This paper focuses on a novel method for successive approximation register analog to digital converter control in synchronized phasor measurement units (PMUs). To compensate for the sampling time error caused by the division remainder between the desirable sampling rate and the oscillator frequency, a variable sampling interval control method is presented by interlacing two integers under a proposed criterion. The frequency of the onboard oscillator is monitored in real-time using the pulse per second (PPS) timing reference from global positioning system. The sampling control is adaptively adjusted each second according to the latest estimated oscillator frequency. The “saw tooth” in phasor angle error and DC offset and spikes in frequency error can be effectively eliminated by applying the proposed method. The simulation and experiment results validate the effectiveness and accuracy of the proposed method, which is believed to be able to greatly improve the performance of PPS-disciplined synchronous sampling methods in PMUs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of a facility for high-precision irradiation of cells with carbon ions

Purpose: Compared to photons, using particle radiation in radiotherapy reduces the dose and irradiated volume of normal tissues, potentially reducing side effects. The biological effect of dose deposited by particles such as carbon ions, however, differs from that of dose deposited by photons. The inaccuracy in models to estimate the biological effects of particle radiation remains the most important source of uncertainties in particle therapy. Improving this requires high-precision studies on biological effects of particle radiation. Therefore, the authors aimed to develop a facility for reproducible and high-precision carbon-ion irradiation of cells in culture. The combined dose nonuniformity in the lateral and longitudinal direction should not exceed {+-}1.5%. Dose to the cells from particles than other carbon ions should not exceed 5%. Methods: A uniform lateral dose distribution was realized using a single scatter foil and quadrupole magnets. A modulator wheel was used to create a uniform longitudinal dose distribution. The choice of beam energy and the optimal design of these components was determined using GEANT4 and SRIM Monte Carlo simulations. Verification of the uniformity of the dose distribution was performed using a scintillating screen (lateral) and a water phantom (longitudinal). The reproducibility of dose delivery between experiments was assessed by repeated measurements of the spatial dose distribution. Moreover, the reproducibility of dose-response measurements was tested by measuring the survival of irradiated HEK293 cells in three independent experiments. Results: The relative contribution of dose from nuclear reaction fragments to the sample was found to be <5% when using 90 MeV/u carbon ions. This energy still allows accurate dosimetry conforming to the IAEA Report TRS-398, facilitating comparison to dose-effect data obtained with other radiation qualities. A 1.3 mm long spread-out Bragg peak with a diameter of 30 mm was created, allowing the irradiation of cell samples with the specified accuracy. Measurements of the transverse and longitudinal dose distribution showed that the dose variation over the sample volume was {+-}0.8% and {+-}0.7% in the lateral and longitudinal directions, respectively. The track-averaged LET of 132{+-}10 keV/{mu}m and dose-averaged LET of 189{+-}15 keV/{mu}m at the position of the sample were obtained from a GEANT4 simulation, which was validated experimentally. Three separately measured cell-survival curves yielded nearly identical results. Conclusions: With the new facility, high-precision carbon-ion irradiations of biological samples can be performed with highly reproducible results.

60 APPLIED LIFE SCIENCES↗

Performance characteristics of a three-axis superconducting rock magnetometer

A series of measurements are carried out with the purpose of quantitatively determining the characteristics of a commercial 6.8 cm access superconducting rock magnetometer located in the magnetic properties laboratory at the Goddard Space Flight Center. The measurements show that although a considerable improvement in measurement speed and signal to noise ratios can be obtained using such an instrument, a number of precautions are necessary to obtain accuracies comparable with more conventional magnetometers. These include careful calibration of the sensor outputs, optimum positioning of the sample within the detection region and quantitatively establishing the degree of cross-coupling between the detector coils. In order to examine the uniformity of response for each detector, the responses are mapped as a function of position, using a small dipole.

Lienert, B. R.↗

Multiple pass gas absorption cell utilizing a spherical mirror opposite one or more pair of obliquely disposed flat mirrors

A method and apparatus for passing light bundles through a multiple pass sampling cell is disclosed. The multiple pass sampling cell includes a sampling chamber having first and second ends positioned along a longitudinal axis of the sampling cell. The sampling cell further includes an entrance opening, located adjacent the first end of the sampling cell at a first azimuthal angular position. The entrance opening permits a light bundle to pass into the sampling cell. The sampling cell also includes an exit opening at a second azimuthal angular position. The light exit permits a light bundle to pass out of the sampling cell after the light bundle has followed a predetermined path.

Pearson, Richard↗

Method for Deriving Telescope Specifications for Earth-Detecting Coronagraphs and Its Use in Prioritizing Technology Development Investments

Different potential exoplanet mission concepts require different enabling and enhancing technologies. Decisions regarding prioritizing the development of these technologies can be made using a Science-Driven Systems-Engineering framework. The white paper makes the following specific recommendations. (1) Any potential telescope/coronagraph combination should develop a wavefront stability error budget using the method described in this white paper. That error budget will inform discussions about what technology development will be needed to enable the mission. (2) Enhancing and enabling technologies requiring investment include: low noise reaction wheels or control moment gyros; micro-thruster technology; active vibration isolation; materials and design practice for making lightweight stiff structures and optical components; 200-hertz wavefront sensing and control; 500-hertz sub-picometer-precision edge sensor and position actuators; non-destructive process to quantify CTE (Coefficient of Thermal Expansion) homogeneity of 4-meter class mirrors to an uncertainty of plus or minus 1 parts per billion per degree Kelvin over a 100 by 100 sampling; laser gauge positional metrology system; and predictive active thermal control.

Space Mirror Technology↗

Laser ablation spectrometry system

This disclosure provides systems, methods, and apparatus related to laser ablation spectrometry systems. In one aspect, a system comprises a microscope, a laser, a continuous flow probe, and a gas confinement device. The laser is positioned to emit light through an objective lens of the microscope. The continuous flow probe is coupled to a spectrometer. An end of the continuous flow probe is positioned proximate a sample and between the sample and the objective lens. The gas confinement device defines a gas inlet, a chamber, a platform, a wall surrounding the platform, a plurality of vents, and a plurality of channels. Each of the plurality of vents is positioned to direct a gas substantially parallel to the platform, and each of the plurality of vents is defined in the wall. The plurality of channels is operable to provide fluid communication between the chamber and the plurality of vents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transmission diamond imaging detector

Many modern synchrotron techniques are trending toward use of high flux beams and/or beams which require enhanced stability and precise understanding of beam position and intensity from the front end of the beamline all the way to the sample. For high flux beams, major challenges include heat load management in optics (including the vacuum windows) and a mechanism of real-time volumetric measurement of beam properties such as flux, position, and morphology. For beam stability in these environments, feedback from such measurements directly to control systems for optical elements or to sample positioning stages would be invaluable. To address these challenges, we are developing diamond-based instrumented vacuum windows with integrated volumetric x-ray intensity, beam profile and beam-position monitoring capabilities. A 50 µm thick single crystal diamond has been lithographically patterned to produce 60 µm pixels, creating a >1kilopixel free-standing transmission imaging detector. This device, coupled with a custom, FPGA-based readout, has been used to image both white and monochromatic x-ray beams and capture the last x-ray photons at the National Synchrotron Light Source (NSLS). This technology will form the basis for the instrumented end-station window of the x-ray footprinting beamline (XFP) at NSLS-II.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of a Micro-Neutralization Test with the Rapid Fluorescent Focus Inhibition Test for Measuring Rabies Virus Neutralizing Antibodies

The rapid fluorescent focus inhibition test (RFFIT) is routinely used in the United States to measure rabies virus neutralizing antibodies (rVNA). RFFIT has a long history of reproducible and reliable results. The test has been modified over the years to use smaller volumes of reagents and samples, but requires a 50 µL minimum volume of test serum. To conduct pathogenesis studies, small laboratory animals such as mice are regularly tested for rVNA, but the minimum volume for a standard RFFIT may be impossible to obtain, particularly in scenarios of repeated sampling. To address this problem, a micro-neutralization test was developed previously. In the current study, the micro-neutralization test was compared to the RFFIT using 129 mouse serum samples from rabies vaccine studies. Using a cut-off value of 0.1 IU/mL, the sensitivity, specificity, and concordance of the micro-neutralization test were 100%, 97.5%, and 98%, respectively. The geometric mean titer of all samples above the cut-off was 2.0 IU/mL using RFFIT and 3.4 IU/mL using the micro-neutralization test, indicating that titers determined using the micro-neutralization test are not equivalent to RFFIT titers. Based on four rVNA-positive hamster serum samples, the intra-assay coefficient of variability was 24% and inter-assay coefficient of variability was 30.4%. These results support continued use of the micro-neutralization test to determine rabies virus neutralizing antibody titers for low-volume serum samples.

59 BASIC BIOLOGICAL SCIENCES↗

Machine learning reveals strong grid-scale dependence in the satellite N d –LWP relationship

The relationship between cloud droplet number concentration ( N d ) and liquid water path (LWP) is highly uncertain yet crucial for determining the impact of aerosol-cloud interactions (ACI) on Earth's radiation budget. The N d -LWP relationship is examined using a machine learning (ML) random forest model applied to five years of satellite data at grid resolutions ranging from 10° to 0.05° in 12 distinct regions. In the subtropics, the shape of the N d -LWP relationship switches from an inverted-V at 1° grid-resolution to an “M” shape at 0.1° resolution with decreased $\frac{\textrm{dln⁡LWP}}{\textrm{dln⁡}N_d}$ sensitivity. Tropical and midlatitude regions generally show a more positive sensitivity. Cloud sampling and filtering also influence this slope, wherein the exclusion of thin clouds, as commonly performed to reduce retrieval uncertainty, leads to strongly negative sensitivity across all regions. Precipitation is primarily responsible for driving the strength of the sensitivity, with strong positive slopes in raining clouds and negative and/or neutral responses found in non-raining clouds. A new method to compute radiative forcing from the ML model shows a robust Twomey radiative forcing across all regions and grid resolutions. However, LWP and cloud fraction adjustments to the radiative forcing, which are ∼50 % or smaller than the Twomey effect, decrease to negligible values with higher spatial resolution data. As Earth system models move toward higher spatial resolutions in the future, evaluating the LWP and CF adjustment contributions to the radiative forcing budget at these finer resolutions will be essential for evaluation and model development.

Aerosol-Cloud Interactions↗

Non-spectroscopic composition measurements of SrTiO 3 -La 0.7 Sr 0.3 MnO 3 multilayers using scanning convergent beam electron diffraction

The local atomic structure of a crystalline sample aligned along a zone axis can be probed with a focused electron probe, which produces a convergent beam electron diffraction pattern. The introduction of high speed direct electron detectors has allowed for experiments that can record a full diffraction pattern image at thousands of probe positions on a sample. By incoherently summing these patterns over crystalline unit cells, we demonstrate in this paper that in addition to crystal structure and thickness, we can also estimate the local composition of a perovskite superlattice sample. This is achieved by matching the summed patterns to a library of simulated diffraction patterns. Finally, this technique allows for atomic-scale chemical measurements without requiring a spectrometer or hardware aberration correction.

74 ATOMIC AND MOLECULAR PHYSICS↗

Detecting active comets with SDSS

Using a sample of serendipitously discovered active comets in the Sloan Digital Sky Survey (SDSS), we develop well-controlled selection criteria for greatly increasing the efficiency of comet identification in the SDSS catalogs. After follow-up visual inspection of images to reject remaining false positives, the total sample of SDSS comets presented here contains 19 objects, roughly one comet per 10 million other SDSS objects. The good understanding of selection effects allows a study of the population statistics, and we estimate the apparent magnitude distribution to r {approx} 18, the ecliptic latitude distribution, and the comet distribution in SDSS color space. The most surprising results are the extremely narrow range of colors for comets in our sample (e.g. root-mean-square scatter of only {approx}0.06 mag for the g-r color), and the similarity of comet colors to those of jovian Trojans. We discuss the relevance of our results for upcoming deep multi-epoch optical surveys such as the Dark Energy Survey, Pan-STARRS, and the Large Synoptic Survey Telescope (LSST), and estimate that LSST may produce a sample of about 10,000 comets over its 10-year lifetime.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗