Search NASA⌕ Search

SEARCH · Search NASA

Results for “SAMPLER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Saline pulse test monitoring with the self‐potential method to nonintrusively determine the velocity of the pore water in leaking areas of earth dams and embankments

A method is proposed to localize preferential fluid flow pathways in porous media on the basis of time‐lapse self‐potential measurements associated with salt tracer injection upstream. This method is first tested using laboratory data. A network of nonpolarizing electrodes located is connected to a highly sensitive voltmeter used to record the resulting electrical field fluctuations occurring over time at the surface of the tank. The transport of the conductive salt plume through the permeable porous materials changes the localized streaming potential coupling coefficient associated with the advective drag of the excess charge of the pore water and is also responsible for a diffusion current associated with the salinity gradient. Monitoring of the electrical potential distribution at the ground surface can be used to localize the pulse of saline water over time and to determine its velocity. This method applies in real time and can be used to track highly localized flow pathways characterized by high permeability. Our sandbox experiment demonstrates the applicability of this new method under well‐controlled conditions with a coarse‐sand channel embedded between fine‐sand banks. A finite element model allows us to reproduce the time‐lapse electrical potential distribution over the channel, but some discrepancies were observed on the banks. Finally, we performed a numerical simulation for a synthetic case study inspired by a recently published field case study. A Markov chain Monte Carlo sampler is used to determine the permeability and the porosity of the preferential fluid flow pathway of this synthetic case study.

54 ENVIRONMENTAL SCIENCES↗

Methods to Evaluate Subcolumn Profiles Based on Two-Point Diagnostics

In atmospheric models, stochastic generation of subgrid-scale profiles or “subcolumns” has been used for a variety of purposes. Such subcolumns can be generated from subgrid probability density functions (PDFs) at different vertical levels, when such PDFs are available. To do so, the generator needs to decide how strongly points should be correlated in the vertical, that is, how much the values should be overlapped. This is sometimes called “PDF overlap.” To assess vertical correlation in a simplified, observable setting, here the vertical correlation of vertical velocity in subcloud layers is examined. Doppler lidar is used to evaluate the vertical profiles of vertical velocity produced by a large-eddy simulation (LES) model and the Subgrid Importance Latin Hypercube Sampler (SILHS) subcolumn generator. In order to diagnose unrealistic features in subcolumn profiles, various statistical diagnostics are examined here, including the bivariate PDF of vertical velocity at two separated points (i.e., altitudes), the two-point velocity correlation, the integral correlation length, the PDF of two-point velocity differences, and the skewness and kurtosis of two-point velocity differences. The profiles produced by LES match lidar well, except that they are too smooth at small scales. The profiles produced by SILHS exhibit sharp jumps from updraft to downdraft that are not observed in the lidar data. To reduce the generation of these unrealistically sharp jumps, the SILHS sampling method is revised. The diagnostics confirm that the revised sampling method reduces the overprediction of sharp jumps.

54 ENVIRONMENTAL SCIENCES↗

Measured air quality impacts after teaching parents about cooking ventilation with a video: a pilot study

BackgroundCooking-related emissions contribute to air pollutants in the home and may influence children’s health outcomes.ObjectiveIn this pilot study, we investigate the effects of a cooking ventilation intervention in homes with gas stoves, including a video-based educational intervention and range hood replacement (when needed) in children’s homes.MethodsThis was a pilot (n = 14), before-after trial (clinicaltrials.gov #NCT04464720) in homes in the San Francisco Bay Area that had a school-aged child, a gas stove, and either a venting range hood or over-the-range microwave/hood. Cooking events, ventilation use, and indoor air pollution were measured in homes for 2–4 weeks, and children completed respiratory assessments. Midway, families received this intervention: (1) education about the hazards of cooking-related pollutants and benefits of both switching to back burners and using the range hood whenever cooking and (2) ensuring the range hood met airflow and sound performance standards. The educational intervention was delivered via a video developed in conjunction with local youth.ResultsWe found substantially increased use of back burners and slight increases in range hood use during cooking after intervening. Even though there was no change in cooking frequency or duration, these behavior changes resulted in decreases in nitrogen dioxide (NO2), including significant decreases in the total integrated concentration of NO2 over all cooking events from 1230 ppb*min (IQR 336, 7861) to 756 (IQR 84.0, 4210; p < 0.05) and NO2 collected on samplers over the entire pre- and post-intervention intervals from 10.4 ppb (IQR 3.5, 47.5) to 9.4 (IQR 3.0, 36.1; p < 0.005). There were smaller changes in PM2.5, and no changes were seen in respiratory outcomes.ImpactThis pilot before-after trial evaluated the use of a four-minute educational video to improve cooking ventilation in homes with gas stoves and one or more school-aged children. Participant behavior changed after watching the video, and there were decreases in indoor air pollutant concentrations in the home, some of which were significant. This brief video is now publicly available in English and Spanish (wspehsu.ucsf.edu/projects/indoor-air-quality), and this provides suggestive evidence of the utility of this simple intervention, which could be particularly beneficial for households that have children with asthma.

Holm, Stephanie M↗

Air, surface, and wastewater surveillance of SARS-CoV-2; a multimodal evaluation of COVID-19 detection in a built environment

Environmental surveillance of infectious organisms holds tremendous promise to reduce human-to-human transmission in indoor spaces through early detection. In this study we determined the applicability and limitations of wastewater, indoor high-touch surfaces, in-room air, and rooftop exhaust air sampling methods for detecting SARS-CoV-2 in a real world building occupied by residents recently diagnosed with COVID-19. We concurrently examined the results of three 24-hour environmental surveillance techniques, indoor surface sampling, exhaust air sampling and wastewater surveillance, to the known daily census fluctuations in a COVID-19 isolation dormitory. Additionally, we assessed the ability of aerosol samplers placed in the large volume lobby to detect SARS-CoV-2 multiple times per day. Our research reveals an increase in the number of individuals confirmed positive with COVID-19 as well as their estimated human viral load to be associated with statistically significant increases in viral loads detected in rooftop exhaust aerosol samples (p = 0.0413), wastewater samples (p = 0.0323,), and indoor high-touch surfaces (p < 0.001)). We also report that the viral load detected in lobby aerosol samples was statistically higher in samples collected during presence of occupants whose COVID-19 diagnostic tests were confirmed positive via qPCR compared to periods when the lobby was occupied by either contact-traced (suspected positive) individuals or during unoccupied periods (p = 0.0314 and <2e–16). We conclude that each daily (24h) surveillance method, rooftop exhaust air, indoor high-touch surfaces, and wastewater, provide useful detection signals for building owner/operator(s). Furthermore, we demonstrate that exhaust air sampling can provide spatially resolved signals based upon ventilation exhaust zones. Additionally, we find that indoor lobby air sampling can provide temporally resolved signals useful during short duration sampling periods (e.g., 2-4 hours) even with intermittent occupancy by occupants diagnosed with COVID-19.

60 APPLIED LIFE SCIENCES↗

Diel transcriptional response of a California Current plankton microbiome to light, low iron, and enduring viral infection

Phytoplankton and associated microbial communities provide organic carbon to oceanic food webs and drive ecosystem dynamics. However, capturing those dynamics is challenging. Here, an in situ, semi-Lagrangian, robotic sampler profiled pelagic microbes at 4 h intervals over ~2.6 days in North Pacific high-nutrient, low-chlorophyll waters. We report on the community structure and transcriptional dynamics of microbes in an operationally large size class (>5 μm) predominantly populated by dinoflagellates, ciliates, haptophytes, pelagophytes, diatoms, cyanobacteria (chiefly Synechococcus ), prasinophytes (chiefly Ostreococcus ), fungi, archaea, and proteobacteria. Apart from fungi and archaea, all groups exhibited 24-h periodicity in some transcripts, but larger portions of the transcriptome oscillated in phototrophs. Periodic photosynthesis-related transcripts exhibited a temporal cascade across the morning hours, conserved across diverse phototrophic lineages. Pronounced silica:nitrate drawdown, a high flavodoxin to ferredoxin transcript ratio, and elevated expression of other Fe-stress markers indicated Fe-limitation. Fe-stress markers peaked during a photoperiodically adaptive time window that could modulate phytoplankton response to seasonal Fe-limitation. Remarkably, we observed viruses that infect the majority of abundant taxa, often with total transcriptional activity synchronized with putative hosts. Taken together, these data reveal a microbial plankton community that is shaped by recycled production and tightly controlled by Fe-limitation and viral activity

Environmental Sciences & Ecology↗

Citywide indoor air sampling mirrors wastewater and clinical for environmental surveillance of respiratory viruses

Wastewater surveillance of respiratory pathogens can provide timely estimates of viral activity and disease trends in a population. Indoor air surveillance could be used similarly with some advantages but remains largely unvalidated at the community -scale. Here, an indoor air surveillance program was employed as part of public health environmental surveillance in Chicago, Illinois, USA. Ten air samplers were placed in healthcare and congregate living settings across the city. Weekly air samples were evaluated for influenza A, influenza B, respiratory syncytial virus, and SARS -CoV-2 over two respiratory virus seasons (2023 -2025). Citywide, aggregated air sample positivity and viral load were closely correlated with local clinical case and wastewater surveillance data across all respiratory viruses. Virus trends in air data often preceded clinical and wastewater, although this varied across pathogens and respiratory virus seasons. Further, whole -genome sequencing of SARS -CoV-2 showed close correlation of variant proportions across all datasets. At the building -scale, air samples obtained from a single sampling device provided efficient respiratory virus surveillance, with respiratory pathogen levels mirroring citywide clinical surveillance data. These data demonstrate that air surveillance can provide respiratory virus case and variant trend data at a building or community -scale, serving as an alternative or complementary tool for public health environmental surveillance.

Wilton, Rosemarie↗

Efficient verification of anticoncentrated quantum states

I present a method for estimating the fidelity F(μ, τ) between a preparable quantum state μ and a classically specified pure target state τ=|τ> <τ|, using simple quantum circuits and on-the-fly classical calculation (or lookup) of selected amplitudes of |τ>. The method is sample efficient for anticoncentrated states (including many states that are hard to simulate classically), with approximate cost 4ϵ –2 (1 – F)dpcoll where ϵ is the desired precision of the estimate, d is the dimension of the Hilbert space, and pcoll is the collision probability of the target distribution. Furthermore, this scaling is exponentially better than that of any method based on classical sampling. I also present a more sophisticated version of the method that uses any efficiently preparable and well-characterized quantum state as an importance sampler to further reduce the number of copies of μ needed. Though some challenges remain, this work takes a significant step toward scalable verification of complex states produced by quantum processors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Near-canopy horizontal concentration heterogeneity of semivolatile oxygenated organic compounds and implications for 2-methyltetrols primary emissions

Semivolatile oxygenated organic compounds (SV-OVOCs) are important atmospheric species, in particular for the production and chemistry of atmospheric particulate matter and related impacts on air quality and climate. In this study, SV-OVOCs were collected in the horizontal plane of the roughness layer over the tropical forest in the central Amazon during the wet season of 2018. A sampler mounted to a copter-type, hovering unmanned aerial vehicle was used. Underlying the collection region, a plateau forest transitioned into a slope forest across several hundred meters. The concentrations of pinonic and pinic acids, which are monoterpene oxidation products, had no statistical difference over the two forests. By comparison, across the study period, differences in the concentration of 2-methyltetrols, which are products of isoprene oxidation, ranged from -70% to +480% over the two forests. The chemical lifetime of 2-methyltetrols in the atmosphere is sufficiently long that heterogeneity in the isoprene emission rate from the two forests followed by atmospheric oxidation does not explain the concentration heterogeneity of 2-methyltetrols. Standing waves and local meteorology also cannot account for the heterogeneity. Of the possibilities considered, the most plausible explanation is the direct emission from the forest of 2-methyltetrols produced through biological processes within the plants. Under this explanation, the rate of direct SV-OVOC emissions should be modulated by forest type and related environmental stressors. Direct emissions of SV-OVOCs should be more broadly considered for constraining and improving models of atmospheric composition, transport, and chemistry over tropical forests.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

BEYONDPLANCK II. CMB mapmaking through Gibbs sampling

We present a Gibbs sampling solution to the mapmaking problem for cosmic microwave background (CMB) measurements that builds on existing destriping methodology. Gibbs sampling breaks the computationally heavy destriping problem into two separate steps: noise filtering and map binning. Considered as two separate steps, both are computationally much cheaper than solving the combined problem. This provides a huge performance benefit as compared to traditional methods and it allows us, for the first time, to bring the destriping baseline length to a single sample. Here, we applied the Gibbs procedure to simulated Planck 30 GHz data. We find that gaps in the time-ordered data are handled efficiently by filling them in with simulated noise as part of the Gibbs process. The Gibbs procedure yields a chain of map samples, from which we are able to compute the posterior mean as a best-estimate map. The variation in the chain provides information on the correlated residual noise, without the need to construct a full noise covariance matrix. However, if only a single maximum-likelihood frequency map estimate is required, we find that traditional conjugate gradient solvers converge much faster than a Gibbs sampler in terms of the total number of iterations. The conceptual advantages of the Gibbs sampling approach lies in statistically well-defined error propagation and systematic error correction. This methodology thus forms the conceptual basis for the mapmaking algorithm employed in the BEYONDPLANCK framework, which implements the first end-to-end Bayesian analysis pipeline for CMB observations.

79 ASTRONOMY AND ASTROPHYSICS↗

BeyondPlanck X. Bandpass and beam leakage corrections

We discuss the treatment of bandpass and beam leakage corrections in the Bayesian BeyondPlanck CMB analysis pipeline as applied to the Planck LFI measurements. As a preparatory step, we first apply three corrections to the nominal LFI bandpass profiles including removal of a known systematic effect in the ground measuring equipment at 61 GHz; smoothing of standing wave ripples; and edge regularization. The main net impact of these modifications is an overall shift in the 70 GHz bandpass of +0.6 GHz; we argue that any analysis of LFI data products, either from Planck or BeyondPlanck, should use these new bandpasses. In addition, we fit a single free bandpass parameter for each radiometer of the form Δ i = Δ 0 + $δ$ i , where Δ 0 represents an absolute frequency shift per frequency band and $δ$i is a relative shift per detector. The absolute correction is only fitted at 30 GHz with a full $\chi$ 2 -based likelihood, resulting in a correction of Δ 30 = 0.24 ± 0.03 GHz. The relative corrections are fitted using a spurious map approach, fundamentally similar to the method pioneered by the WMAP team, but without introducing many additional degrees of freedom. All bandpass parameters are sampled using a standard Metropolis sampler within the main BeyondPlanck Gibbs chain, and bandpass uncertainties are thus propagated to all other data products in the analysis. In total, we find that our bandpass model significantly reduces leakage effects. For beam leakage corrections, we adopt the official Planck LFI beam estimates without additional degrees of freedom, and only marginalize over the underlying sky model. We note that this is the first-time leakage from beam mismatch has been included for Planck LFI maps.

79 ASTRONOMY AND ASTROPHYSICS↗

Measured Indoor Nitrogen Oxides in Homes with a Child with Asthma and Gas or Induction Electric Cooking

The Cooking Energy and Ventilation Impacts on Children's Asthma (CEVICA) study is a randomized control trial investigating the effects of replacing gas with induction electric ranges in the homes of children with asthma in California's San Joaquin Valley. Indoor air quality parameters and respiratory health indicators were measured over 2-week intensive at Baseline and after consecutive 3-month study phases, with half getting electric cooking at the start of Phase 1 and others in Phase 2. Indoor air measurements included time-integrated NO 2 and NO X by passive sampler and time-resolved NO 2 by electrochemical sensors. In the first 40 homes, data were collected during 61 intensives for gas cooking and 55 for induction. Cooking was identified using temperature sensors above the cooktop. Pollutant events were identified from sharp rises in concentrations Time integrated NOX species were lower with electric cooking, with mean differences of 14.2 ppb for NO 2 (95% CI: 9.6, 18.7; p < 0.001), 55.6 ppb for NO X (95% CI: 30.4, 80.9; p < 0.001), and 41.5 ppb for derived NO (95% CI: 19.7, 63.2; p < 0.001). A paired, within home analysis showed larger reductions in Group 2 (gas to induction) than Group 1 that remained electric across Phase 1 and Phase 2 for NO 2 (mean difference in As of 10.5 ppb; 95% CI: 5.6, 15.4; p < 0.001), NO X (32.3 ppb; 95% CI: 10.0, 54.5; p=0.007), and derived NO (21.8 ppb; 95% CI: 3.6, 40.0; p=0.022). Compared to electric cooking, gas had much higher rates of associated NO 2 events, and larger above-baseline NO 2 peaks. These preliminary results are consistent with prior findings that shifting to induction cooking can substantially lower indoor NO 2 compared with gas cooking.

Fang, Yi↗

Measured indoor PM2.5, black carbon, and oxidative potential before and after replacing gas with induction cooking in asthmatic households

Cooking is a major source of fine particulate matter (PM) in homes and evidence to date is inconclusive about the impact of cooking fuel on measures of residential PM exposure. The Cooking Energy and Ventilation Impacts on Children's Asthma (CEVICA) study measured cooking frequency, range hood use, indoor air quality (IAQ) and respiratory health indicators of children with asthma living in homes with gas stoves in California's San Joaquin Valley. Intensive measurements occurred over three 2-week intensive periods: at baseline and at the end of two consecutive 3-month study phases. Participants were randomly assigned to have their gas stoves replaced with electric induction at the start of Phase 1 or Phase 2. As part of the IAQ assessment, we collected particulate matter on Teflon filters using ultrasonic personal air samplers (UPAS). The filters were analyzed to quantify time-integrated PM 2.5 mass concentration, black carbon (BC) oxidative potential (OP). OP was measured using the SLF-OH assay, an acellular chemical assay that quantifies production of OH radicals in simulated lung fluid (SLF). Across all comparisons, PM 2.5 mass tended to be higher during gas cooking than induction electric cooking, although only one transition (Baseline to Phase 1) was statistically discernible at p<0.05. BC and mass-normalized OP showed no measurable differences across stove types or across phases. These preliminary findings suggest that stove fuel alone may not be the dominant determinant of indoor PM 2.5 concentrations in this sample, as previous studies have reported that indoor PM 2.5 during cooking can also be influenced by factors such as cooking practices, food and oil type, kitchen ventilation, and outdoor infiltration.

Lin, Zhuoying↗

Optical and electrical characterization of pulse-modulated argon atmospheric-pressure inductively coupled microplasma jets

The critical parameters determining the generation of the pulse-modulated argon atmospheric-pressure inductively coupled plasma (AP-ICP) microjet were studied by varying the power, P, pulse-modulation frequency, f, and duty ratio, DR. The temporal changes in the net output power, P{sub net}, monitored between the very high frequency power supply and matching network by an rf sampler, and ArI 4s{sup '}[1/2]{sub 1}{sup O}-4p{sup '}[1/2]{sub 0} emission from the antenna were measured to elucidate the behavior of this plasma. The AP-ICP microjet, which produces high-density (0.9-1.1x10{sup 15} cm{sup -3}) nonequilibrium plasma, consists of an alumina discharge tube with the inner diameter of 0.8 mm. The generation diagram of the pulse-modulated plasma was created by having f as the horizontal axis and DR as the vertical axis while varying P up to 50 W. At f{<=}10 kHz, the plasma was generated at above the linear lines of f and DR, which indicated the existence of the critical power-off period of approximately 80 {mu}s. At f>10 kHz, the pulse-modulated plasma was produced above constant DR and almost independent of f. The time-averaged power, P, which is the product of P and DR, had to be more than 8-10 W to sustain the pulse-modulated plasma. From the measurement of the temporal changes in the net power and ArI emission, the dynamic behavior of the pulse-modulated plasma was revealed as follows. The prebreakdown period was present for {approx}5 {mu}s after the power was turned on. Once the plasma was generated, the impedance was changed and the reflected power gradually decreased. A strong emission peak was observed immediately after the breakdown, followed by the gradual increase up to the steady state. Finally, the intense afterpeak was observed at 0.8 {mu}s after the power was turned off.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Capillary Absorption Spectrometer for Stable Carbon Isotope Ratio (13C/12C) Analysis in Very Small Samples

A capillary absorption spectrometer (CAS) suitable for IR laser isotope analysis of small CO{sub 2} samples is presented. The system employs a continuous-wave (cw) quantum cascade laser to study nearly adjacent rovibrational transitions of different isotopologues of CO{sub 2} near 2307 cm{sup -1} (4.34 {mu}m). This initial CAS system can achieve relative isotopic precision of about 10 ppm {sup 13}C, or {approx}1{per_thousand} (per mil in delta notation relative to Vienna Pee Dee Belemnite) with 20-100 picomoles of entrained sample within the hollow waveguide for CO{sub 2} concentrations {approx}400 to 750 ppm. Isotopic analyses of such gas fills in a 1-mm ID hollow waveguide of 0.8 m overall physical path length can be carried out down to {approx}2 Torr. Overall {sup 13}C/{sup 12}C ratios can be calibrated to {approx}2{per_thousand} accuracy with diluted CO{sub 2} standards. A novel, low-cost method to reduce cw-fringing noise resulting from multipath distortions in the hollow waveguide is presented, which allows weak absorbance features to be studied at the few ppm level (peak-to-rms) after 1,000 scans are co-added in {approx}10 sec. The CAS is meant to work directly with converted CO{sub 2} samples from a Laser Ablation-Catalytic-Combustion (LA CC) micro-sampler to provide {sup 13}C/{sup 12}C ratios of small biological isolates with spatial resolutions {approx}50 {mu}m.

47 OTHER INSTRUMENTATION↗

Multi-parametric approach towards the assessment of radon and thoron progeny exposures

Conventionally, the dosimetry is carried out using radon and thoron gas concentration measurements and doses have been assigned using assumed equilibrium factors for the progeny species, which is inadequate pertaining to the variations in equilibrium factors and possibly due to significant thoron. In fact, since the true exposures depend upon the intricate mechanisms of progeny deposition in the lung, therefore an integrated approach for the assessment of progeny is essential. In this context, the recently developed deposition based progeny concentration measurement techniques (DTPS: Direct Thoron progeny sensors and DRPS: Direct Radon progeny sensors) appear to be best suited for radiological risk assessments both among occupational workers and general study populations. DTPS and DRPS consist of aluminized mylar mounted LR115 type passive detectors, which essentially detects the alpha particles emitted from the deposited progeny atoms on the detector surface. It gives direct measure of progeny activity concentrations in air. DTPS has a lower limit of detection limit of 0.1 Bq/m{sup 3} whereas that for DRPS is 1 Bq/m{sup 3}, hence are perfectly suitable for indoor environments. These DTPS and DRPS can be capped with 200-mesh type wire-screen to measure the coarse fraction of the progeny concentration and the corresponding coarse fraction deposition velocities as well as the time integrated fine fraction. DTPS and DRPS can also be lodged in an integrated sampler wherein the wire-mesh and filter-paper are arranged in an array in flow-mode, to measure the fine and coarse fraction concentration separately and simultaneously. The details are further discussed in the paper.

61 RADIATION PROTECTION AND DOSIMETRY↗

Assessment of heavy metals in seawater and fish tissues at Pulau Indah, Selangor, Malaysia

This study focuses on the levels of heavy metals in seawater and selected fish tissue at Pulau Indah, Selangor, Malaysia. Pulau Indah primarily contains Westport (Malaysia’s major port), and a host of full scales factories. Therefore, it is important to monitor the levels of pollution in this water body and the aquatic organisms in the long term effects, due to the human activities in this area. Water samples in this study were taken from 8 locations along the coastal area. The water samples were collected using water sampler and sampling locations were determined using a Global Positioning system (GPS). Similarly, in situ water quality parameters including temperature, dissolve oxygen (DO), salinity, total suspended solid (TSS), pH and turbidity were measured by using portable multi probes meter. Then, the samples were acidified until pH 2 and filtered. Fish samples were purchased from local fisherman along the Pulau Indah coastal area and samples were digested using concentrated nitric acid in wet digestion method. The levels of selected heavy metals in four species of fish and seawater from Pulau Indah coastal area were determined using Inductive Coupled Plasma Mass Spectrometer (ICPMS) after dilution to the samples. In general, the quality of water at Pulau Indah is lower than Malaysia Marine Water Quality Standard except for few locations were higher than the maximum permissible levels. The concentration of heavy metals which are lead (Pb), copper (Cu), zinc (Zn) and uranium (U) in water samples are in the range of 0.36-5.43 µg/L, 75.20-621.58 µg/L, 11.92-30.52 µg/L, and 4.00-4.65 µg/L respectively. While the results of the four selected fish showed the following order of abundance Zn> U> Cu> Pb. Transfer factor (TF) of heavy metals in fish tissue of selected fish species from the water was discussed. However, the observed metal concentration in the sample tissue did not exceed the allowable limit of Malaysian Food Act (1983) and Regulation (1985). Therefore, it is safe for human consumption. Moreover, the pollution levels of these heavy metals were also compared with other studies. This present study can also be used to evaluate the safety dose uptake level of marine biota as well as to monitor environmental health.

54 ENVIRONMENTAL SCIENCES↗

Exact and efficient hybrid Monte Carlo algorithm for accelerated Bayesian inference of gene expression models from snapshots of single-cell transcripts

Single cells exhibit a significant amount of variability in transcript levels, which arises from slow, stochastic transitions between gene expression states. Elucidating the nature of these states and understanding how transition rates are affected by different regulatory mechanisms require state-of-the-art methods to infer underlying models of gene expression from single cell data. A Bayesian approach to statistical inference is the most suitable method for model selection and uncertainty quantification of kinetic parameters using small data sets. However, this approach is impractical because current algorithms are too slow to handle typical models of gene expression. To solve this problem, we first show that time-dependent mRNA distributions of discrete-state models of gene expression are dynamic Poisson mixtures, whose mixing kernels are characterized by a piecewise deterministic Markov process. Here, we combined this analytical result with a kinetic Monte Carlo algorithm to create a hybrid numerical method that accelerates the calculation of time-dependent mRNA distributions by 1000-fold compared to current methods. We then integrated the hybrid algorithm into an existing Monte Carlo sampler to estimate the Bayesian posterior distribution of many different, competing models in a reasonable amount of time. We demonstrate that kinetic parameters can be reasonably constrained for modestly sampled data sets if the model is known a priori. If there are many competing models, Bayesian evidence can rigorously quantify the likelihood of a model relative to other models from the data. We demonstrate that Bayesian evidence selects the true model and outperforms approximate metrics typically used for model selection.

59 BASIC BIOLOGICAL SCIENCES↗