Search NASA⌕ Search

SEARCH · Search NASA

Results for “STRESS CORROSION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Transient Reliability Analysis Capability Developed for CARES/Life

The CARES/Life software developed at the NASA Glenn Research Center provides a general-purpose design tool that predicts the probability of the failure of a ceramic component as a function of its time in service. This award-winning software has been widely used by U.S. industry to establish the reliability and life of a brittle material (e.g., ceramic, intermetallic, and graphite) structures in a wide variety of 21st century applications.Present capabilities of the NASA CARES/Life code include probabilistic life prediction of ceramic components subjected to fast fracture, slow crack growth (stress corrosion), and cyclic fatigue failure modes. Currently, this code can compute the time-dependent reliability of ceramic structures subjected to simple time-dependent loading. For example, in slow crack growth failure conditions CARES/Life can handle sustained and linearly increasing time-dependent loads, whereas in cyclic fatigue applications various types of repetitive constant-amplitude loads can be accounted for. However, in real applications applied loads are rarely that simple but vary with time in more complex ways such as engine startup, shutdown, and dynamic and vibrational loads. In addition, when a given component is subjected to transient environmental and or thermal conditions, the material properties also vary with time. A methodology has now been developed to allow the CARES/Life computer code to perform reliability analysis of ceramic components undergoing transient thermal and mechanical loading. This means that CARES/Life will be able to analyze finite element models of ceramic components that simulate dynamic engine operating conditions. The methodology developed is generalized to account for material property variation (on strength distribution and fatigue) as a function of temperature. This allows CARES/Life to analyze components undergoing rapid temperature change in other words, components undergoing thermal shock. In addition, the capability has been developed to perform reliability analysis for components that undergo proof testing involving transient loads. This methodology was developed for environmentally assisted crack growth (crack growth as a function of time and loading), but it will be extended to account for cyclic fatigue (crack growth as a function of load cycles) as well.

Nemeth, Noel N.↗

Reaction Control System Thruster Cracking Consultation: NASA Engineering and Safety Center (NESC) Materials Super Problem Resolution Team (SPRT) Findings

The shuttle orbiter s reaction control system (RCS) primary thruster serial number 120 was found to contain cracks in the counter bores and relief radius after a chamber repair and rejuvenation was performed in April 2004. Relief radius cracking had been observed in the 1970s and 1980s in seven thrusters prior to flight; however, counter bore cracking had never been seen previously in RCS thrusters. Members of the Materials Super Problem Resolution Team (SPRT) of the NASA Engineering and Safety Center (NESC) conducted a detailed review of the relevant literature and of the documentation from the previous RCS thruster failure analyses. It was concluded that the previous failure analyses lacked sufficient documentation to support the conclusions that stress corrosion cracking or hot-salt cracking was the root cause of the thruster cracking and lacked reliable inspection controls to prevent cracked thrusters from entering the fleet. The NESC team identified and performed new materials characterization and mechanical tests. It was determined that the thruster intergranular cracking was due to hydrogen embrittlement and that the cracking was produced during manufacturing as a result of processing the thrusters with fluoride-containing acids. Testing and characterization demonstrated that appreciable environmental crack propagation does not occur after manufacturing.

MacKay, Rebecca A.↗

A Tool Measuring Remaining Thickness of Notched Acoustic Cavities in Primary Reaction Control Thruster NDI Standards

Stress corrosion cracking in the relief radius area of a space shuttle primary reaction control thruster is an issue of concern. The current approach for monitoring of potential crack growth is nondestructive inspection (NDI) of remaining thickness (RT) to the acoustic cavities using an eddy current or remote field eddy current probe. EDM manufacturers have difficulty in providing accurate RT calibration standards. Significant error in the RT values of NDI calibration standards could lead to a mistaken judgment of cracking condition of a thruster under inspection. A tool based on eddy current principle has been developed to measure the RT at each acoustic cavity of a calibration standard in order to validate that the standard meets the sample design criteria.

Sun, Yushi↗

Net Shape Spin Formed Cryogenic Aluminum Lithium Cryogenic Tank Domes for Lower Cost Higher Performance Launch Vehicles

With the goal of lower cost (simplified manufacturing and lower part count) and higher performance (higher strength to weight alloys) the NASA Technical Maturation Program in 2006 funded a proposal to investigate spin forming of space launch vehicle cryogenic tank domes. The project funding continued under the NASA Exploration Technology Development Program through completion in FY12. The first phase of the project involved spin forming of eight, 1 meter diameter "path finder" domes. Half of these were processed using a concave spin form process (MT Aerospace, Augsburg Germany) and the other half using a convex process (Spincraft, Boston MA). The convex process has been used to produce the Ares Common Bulkhead and the concave process has been used to produce dome caps for the Space Shuttle light weight external tank and domes for the NASDA H2. Aluminum Lithium material was chosen because of its higher strength to weight ratio than the Aluminum 2219 baseline. Aluminum lithium, in order to obtain the desired temper (T8), requires a cold stretch after the solution heat treatment and quench. This requirement favors the concave spin form process which was selected for scale up. This paper describes the results of processing four, 5.5 meter diameter (upper stage scale) net shaped spin formed Aluminum Lithium domes. In order to allow scalability beyond the limits of foundry and rolling mills (about 12 foot width) the circular blank contained one friction stir weld (heavy lifter scales require a flat blank containing two welds). Mechanical properties data (tensile, fracture toughness, stress corrosion, and simulated service testing) for the parent metal and weld will also be discussed.

Curreri, Peter A.↗

Effects of Aqueous Solutions on the Slow Crack Growth of Soda-Lime-Silicate Glass

The slow crack growth (SCG) parameters of soda-lime-silicate were measured in distilled and saltwater of various concentrations in order to determine if the presence of salt and the contaminate formation of a weak sodium film affects stress corrosion susceptibility. Past research indicates that solvents affect the rate of crack growth; however, the effects of salt have not been studied. The results indicate a small but statistically significant effect on the SCG parameters A and n at high concentrations; however, for typical engineering purposes, the effect can be ignored.

salt↗

The Effects of Salt Water on the Slow Crack Growth of Soda Lime Silicate Glass

The slow crack growth parameters of soda-lime silicate were measured in distilled and salt water of various concentrations in order to determine if stress corrosion susceptibility is affected by the presence of salt and the contaminate formation of a weak sodium film. Past research indicates that solvents effect the rate of crack growth, however, the effects of salt have not been studied. The results indicate a small but statistically significant effect on the slow crack growth parameters A and n. However, for typical engineering purposes, the effect can be ignored.

Toughness↗

Effect of Control Mode and Test Rate on the Measured Fracture Toughness of Advanced Ceramics

The effects of control mode and test rate on the measured fracture toughness of ceramics were evaluated by using chevron-notched flexure specimens in accordance with ASTM C1421. The use of stroke control gave consistent results with about 2% (statistically insignificant) variation in measured fracture toughness for a very wide range of rates (0.005 to 0.5 mm/min). Use of strain or crack mouth opening displacement (CMOD) control gave approx. 5% (statistically significant) variation over a very wide range of rates (1 to 80 μm/m/s), with the measurements being a function of rate. However, the rate effect was eliminated by use of dry nitrogen, implying a stress corrosion effect rather than a stability effect. With the use of a nitrogen environment during strain controlled tests, fracture toughness values were within about 1% over a wide range of rates (1 to 80 micons/m/s). CMOD or strain control did allow stable crack extension well past maximum force, and thus is preferred for energy calculations. The effort is being used to confirm recommendations in ASTM Test Method C1421 on fracture toughness measurement.

silicon nitride↗

Effect of Control Mode and Load Rate on Fracture Toughness of Brittle Ceramics

The effects of control mode and rate on the fracture toughness of ceramics were measured by using chevron-notched flexure specimen in accordance with ASTM C1421. The use of stroke control gave consistent results with about 2% variation in measured fracture toughness for a very wide range of rates (0.005 to 0.5 mm/min). Use of strain or CMOD control gave an approximately 5% variation over a very wide range of rates, with the measurements being a function of rate. However, the effect was eliminated by use of dry nitrogen, implying a stress corrosion effect rather than a stability effect. With the use of nitrogen for strain control, fracture toughness values were within about 1% over a wide range of rates (1 to 80 micro-epsilon/sec.). CMOD or strain control did allow stable crack extension well past maximum load, and thus is preferred for energy calculations. The effort is being used to confirm recommendations in ASTM International standard C1421 on fracture toughness measurement.

control mode↗

Effect of Control Mode and Test Rate on Fracture Toughness of Advanced Ceramics

The effects of control mode and rate on the fracture toughness of ceramics were measured by using chevron-notched flexure specimen in accordance with ASTM C1421. The use of stroke control gave consistent results with about 2% variation in measured fracture toughness for a very wide range of rates (0.005 to 0.5 mm/min). Use of strain or CMOD control gave ~5% variation over a very wide range of rates, with the measurements being a function of rate. However, the effect was eliminated by use of dry nitrogen, implying a stress corrosion effect rather than a stability effect. With the use of nitrogen for strain control, fracture toughness values were within about 1% over a wide range of rates (1 to 80 /s). CMOD or strain control did allow stable crack extension well past maximum load, and thus is preferred for energy calculations. The effort is being used to confirm recommendations in ASTM International standard C1421 on fracture toughness measurement.

fracture toughness↗

Failure of Nd:YVO4 Amplifier Crystals

Brittle single crystals are used in NASA applications ranging from lenses to centrally heated laser slabs. Despite standard procedures to design such components, unexpected failures occasionally occur. The ICEsat-2 (Ices,Cloud, and Elevation satellite-2) employs Yttrium orthovanadate single crystals in laser amplifiers and oscillators. Although the systems are currently flying and successfully operating, some unexpected crystal fractures occurred just prior to flight. The failures were traced to poor crystal quality along with time-dependent chemical reaction within the system assembly that increased stress beyond expectations and promoted both fast fracture and stress corrosion. This presentation will discuss failure analysis of the crystals and the chemical reactions that promoted failures, along with corrective actions taken to reduce likelihood of fracture over the three-year mission. Re-designed lasers were stored for 12 months and operated for a total of 1,000 hours without signs of degradation.

Design↗

Failure of Nd:YVO4 Amplifier Crystals

Brittle single crystals are used in NASA applications ranging from lenses to centrally heated laser slabs. Despite standard procedures to design such components, unexpected failures occasionally occur. The ICEsat-2 (Ices, cloud, and elevation satellite) employs Yttrium orthovanadate single crystals in laser amplifiers and oscillators. Although the systems are currently flying and successfully operating, some unexpected crystal fractures occurred just prior to flight. The failures were traced to poor crystal quality along with time depend chemical reaction within the system assembly that increased stress beyond expectations and promoted both fast fracture and stress corrosion. This presentation will discuss failure analysis of the crystals and the chemical reactions that promoted failures, along with corrective actions taken to reduce likelihood of fracture over the three year mission. Re-designed lasers were stored for 12 months and operated for a total of 1,000 hours without signs of degradation.

Salem, Jon↗

FLAW STABILITY ANALYSIS OF SURFACE CRACKS IN DOE STANDARD CANISTERS UNDER OPERATION LOADS AND WELDING RESIDUAL STRESSES

There are over 3000 commercial spent nuclear fuel (SNF) storage canisters that are made of stainless steel and planned for multi-purpose functions of SNF handling: interim storage, transportation, and ultimate disposal at a future SNF disposition location. To date, many multi-purpose canisters (MPC) are located in coastal regions for long-term storage. The canisters are fabricated by welding, and post-welding heat treatment is not required for relieving welding residual stresses (WRS). As a result, these canisters may be susceptible to chloride induced stress corrosion cracking (CISCC) due to the chloride-bearing marine salts. The flaw stability analysis of MPC canisters was performed at SRNL (i.e., PVP2016-4935 and PVP2016-63887) for through-wall flaws and for surface flaws respectively, where WRS was considered, and the failure assessment diagram (FAD)-based fracture mechanics method codified by API 579-1/ASME FFS-1-2007 Edition was adopted.

DOE standard canister↗

Impact of Irradiation on Microstructure and Mechanical Properties of Materials Produced by Advanced Manufacturing

Advanced non-light water reactor designs, known as Generation IV (Gen IV) reactors, typically operate at higher temperatures and under more extreme radiation conditions than conventional light water reactors. A critical aspect of the successful deployment and advancement of Gen IV reactor designs is the selection of appropriate structural materials for specific applications, which necessitates the timely development of new materials and manufacturing processes. Advanced manufacturing (AM) offers numerous opportunities for innovative designs, enabling the production of high-performance components with potentially shorter development cycles compared to traditional manufacturing methods. However, a significant challenge in deploying AM technologies in the nuclear energy sector is the current lack of data on the irradiation performance of AM-produced components. This presentation will discuss neutron and ion irradiation results of AM materials, including stainless steel 316L, Grade 91, SA508, Inconel 718, and Inconel 625 materials. The materials were manufactured by AM, such as Powder Metallurgy Hot Isostatic Pressing (PM HIP), Laser Powder Bed Fusion (LPBF) and Directed Energy Deposition (DED). The effects of neutron irradiation on microstructure (e.g., dislocations, loops, and nanoclusters), tensile properties (e.g., strength and ductility), and ion irradiation on Irradiation-Assisted Stress Corrosion Cracking (IASCC) will be explored. Results are collected from several projects supported by the Nuclear Science User Facilities (NSUF) program.

36 - MATERIALS SCIENCE↗

Mechanical Behavior of Neutron Irradiated Refractory Multi-Principal Element Alloys Processed via Spark Plasma Sintering

The search for advanced materials capable of withstanding the extreme conditions of Generation IV reactors is a critical area in materials science research. These reactors operate under severe environments, including high temperatures, corrosion, stress, and irradiation damage. Consequently, there is a need for innovative alloy systems to ensure the reliability and longevity of proposed Generation IV reactor components. Refractory multi-principal-element alloys (RMPEA) have emerged as a promising candidate due to their exceptional properties. These alloys, characterized by their composition of multiple principal elements in near-equiatomic ratios, exhibit superior resistance to irradiation damage, reduced void swelling, enhanced microstructural stability, and minimal irradiation-induced hardening. While initial studies on RMPEAs have shown promising results, most research has been limited to thin films, nanocrystalline microstructures, and ion irradiation, which do not accurately represent the behavior of bulk materials. To address this gap, our research focused on the neutron irradiation of bulk RMPEAs. We aim to conduct comprehensive post-irradiation examinations (PIE) of RMPEAs irradiated at the Advanced Test Reactor at Idaho National Laboratory. The RMPEAs were synthesized using spark plasma sintering (SPS) with mechanically alloyed metallurgical powder. The RMPEA specimens are a MoNbTi alloy system with additions of -Zr, and -ZrV. Furthermore, PIE consisted of mechanical testing and advanced materials characterization. The mechanical testing consisted of sub-sized tensile testing, micro- and nano- indentation. Microstructural characterization included scanning electron microscopy and transmission electron microscopy. Mechanical testing coupled with advanced microscopy techniques provides insight into phase morphology and its effects on the mechanical properties of the RMPEA specimens. The results indicate that both pristine and irradiated RMPEA specimens exhibited brittle behavior during tensile testing, which can be attributed to their heterogeneous microstructure. The SPS manufacturing process did not include any post treatment, which resulted in a heterogeneous microstructure. Energy-dispersive X-ray spectroscopy revealed the presence of intermetallic such as laves phases within the microstructure. Specifically, Ti-rich precipitates were observed in the MoNbTi specimen, while Mo-rich precipitates were found in the MoNbTiZrV specimen. Nano-hardness testing of pristine samples showed that the laves phases exhibited higher hardness values compared to the matrix phase, suggesting that precipitate hardening is likely the dominant hardening mechanism in these specimens. The results from this work will be used to build a finite element model to predict mechanical behavior of future MPEA compositions. Thus, enabling for a streamlined approach to developing novel MPEAs for the nuclear industry.

36 - MATERIALS SCIENCE↗

Internal stresses in wear and corrosion resistant amorphous metallic coatings of (W/0.6/Re/0.4/)76B24 and (Mo/0.6/Ru/0.4/)82B18

Hard protective coatings in the W-Re-B and Mo-Ru-B alloy systems have been deposited by magnetron sputtering onto soda-lime glass and heat-treated AISI 52100 steel substrates. X-ray diffraction has confirmed the amorphous nature of the as-deposited coatings, and their crystallization temperatures were determined by differential thermal analysis to be 1000 and 790 C for W-Re-B and Mo-Ru-B coatings, respectively. Both coatings exhibit high microhardness; Mo-Ru-B, in addition, has excellent corrosion resistance by comparison with pure Mo at high anodic potentials. Attention is given to the influence of internal stresses on the protective properties of the coatings deposited under different conditions.

Thakoor, A. P.↗

Effects of environmental variables on the crack initiation stages of corrosion fatigue of high strength aluminum alloys

Fatigue initiation in six aluminum alloys used in the aircraft industry was investigated. Cyclic loading superimposed on a constant stress was alternated with atmospheric corrosion. Tests made at different stress levels revealed that a residual stress as low as 39% of the yield strength caused stress corrosion cracking in some of the alloys. An atmospheric corrosion rate meter developed to measure the corrosivity of the atmosphere is described. An easily duplicated hole in the square test specimen with a self-induced residual stress was developed.

Poteat, L. E.↗