Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensitivity Matrix”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Alpha-Imaging Detector System Development for Large Area Monitoring

Effective management and disposal of legacy nuclear waste are essential for ensuring safe work environments and minimizing environmental impacts. Monitoring airborne actinide contamination is particularly critical due to the high internal dose potential of alpha-emitting radionuclides. Traditional continuous air monitoring systems (CAMs) used in the industry are limited in the volume of air they can sample, potentially leading to inaccurate radiation detection over large areas. For example, in 2018, elevated levels of airborne Plutonium-239 were detected beyond the controlled areas of the Hanford Plutonium Finishing Plant, highlighting the potential risks to both plant workers and nearby residents. To address these challenges, high-efficiency particulate absorbing (HEPA) air purifiers can enhance air flow by up to 1.5 orders of magnitude, thereby increasing monitoring efficiency and providing a cost-effective solution for large-area surveillance. To quantify the activities of alpha-emitting radionuclides on HEPA filters, the Savannah River National Laboratory is developing an advanced alpha-imaging detection system. This system includes scintillating materials combined with a digital scientific camera. A significant concern in operating such a large-area airborne monitoring system is the handling of HEPA filters, which may be contaminated with radioactive particles. To mitigate these hazards, it is crucial to ensure that any contamination is securely fixed onto the filters. Efforts have been made to optimize the sensitivity of scintillator-epoxy composites and apply them to HEPA filters. These materials were characterized using fluoroscence spectroscopy. These techniques confirmed the purity of the raw materials, the dispersion of scintillators in the epoxy matrix, and the stability of their optical and structural properties post-modification. The optimal scintillator-epoxy composite was selected for use on alpha-spiked HEPA filters to evaluate the efficiency of the sprayer. HEPA filters, embedded with alpha particles collected by an air purifier deployed in an airborne radiation area, have been tested to assess detection efficiency. Future work will focus on employing multiple imaging sensors simultaneously to enhance sensitivity across different regions of the HEPA filter.

Pham, Phuong [Savannah River National Laboratory (↗

Low level detection of Cs-135 and Cs-137 in environmental samples by ICP-MS

The measurement of the fission product cesium isotopes 135Cs and 137Cs at low femtogram (fg) 10-15 levels in ground water by Inductively Coupled Plasma-Mass Spectrometry ICP-MS is reported. To eliminate the potential natural barium isobaric interference on the cesium isotopes, in-line chromatographic separation of the cesium from barium was performed followed by high sensitivity ICP-MS analysis. A high efficiency desolvating nebulizer system was employed to maximize ICP-MS sensitivity ~10cps/femtogram. The three sigma detection limit measured for 135Cs was 2fg/ml (0.1uBq/ml) and for 137Cs 0.9fg/ml (0.0027Bq/ml) with analysis time of less than 30 minutes/sample. Cesium detection and 135/137 isotope ratio measurement at very low femtogram levels using this method in a ground water matrix is also demonstrated.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Optimization of detection sensitivity for a Fiber Optic Intrusion Detection System (FOIDS) using design of experiments.

The Fiber Optic Intrusion Detection System (FOIDS)1 is a physical security sensor deployed on fence lines to detect climb or cut intrusions by adversaries. Calibration of detection sensitivity can be time consuming because, for example, the FiberSenSys FD-332 has 32 settings that can be adjusted independently to provide a balance between a high probability of detection and a low nuisance alarm rate. Therefore, an efficient method of calibrating the FOIDS in the field, other than by trial and error, was needed. This study was conducted to: x Identify the most significant settings for controlling detection x Develop a way of predicting detection sensitivity for given settings x Develop a set of optimal settings for validation The Design of Experiments (DoE) 2-4 methodology was used to generate small, planned test matrixes, which could be statistically analyzed to yield more information from the test data. Design of Experiments is a statistical methodology for quickly optimizing performance of systems with measurable input and output variables. DoE was used to design custom screening experiments based on 11 FOIDS settings believed to have the most affect on WKH types of fence perimeter intrusions were evaluated: simulated cut intrusions and actual climb intrusions. Two slightly different two-level randomized fractional factorial designed experiment matrixes consisting of 16 unique experiments were performed in the field for each type of intrusion. Three repetitions were conducted for every cut test; two repetitions were conducted for every climb test. Total number of cut tests analyzed was 51; the total number of climb tests was 38. This paper discusses the results and benefits of using Design of Experiments (DoE) to calibrate and optimize the settings for a FOIDS sensor

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Search for 0ν2β of {sup 100}Mo by NEMO-3 and status of SuperNEMO

The NEMO-3 experiment was devoted to the research of the neutrinoless double beta decay and the precise measurement of the two-neutrino double beta decay of seven isotopes. The detector took data in the Laboratoire Souterrain de Modane (LSM) from 2003 to 2011. The unique combination of a 3D-tracker and a calorimeter allowed to fully reconstruct the double beta decay events topology and strongly reduces the backgrounds. This feature also permitted to characterize the remaining backgrounds in independent analysis channels. With an exposure of 34.7 kg·y of {sup 100}Mo no evidence for the 0ν2β signal has been found, yielding a limit for the light Majorana neutrino mass mechanism of T{sub 1/2}(0ν2β) > 1.1 10{sup 24} years (90 % C.L.) once both statistical and systematic uncertainties are taken into account. Depending on the Nuclear Matrix Elements this corresponds to an upper limit on the Majorana effective neutrino mass of |m{sub ββ}| < 0.3 − 0.9 eV (90 % C.L.). Constraints on other lepton number violating mechanisms of 0ν2β decays are also given. Searching for high-energy double electron events in all suitable sources of the detector, no event in the energy region [3.2-10] MeV is observed for an exposure of 47 kg·y. The next generation experiment, SuperNEMO, will use the same experimental technique to extend the sensitivity on the neutrinoless double beta decay search. Several aspects have been improved compared to NEMO-3: choice of the isotope, energy resolution, energy losses… but the main challenge is the background reduction. All the detector materials have been selected for their low natural radioactivity contaminations through High Purity Germanium (HPGe) gamma spectroscopy. The double beta sources after enrichment are being prepared with extreme care and the ultimate contaminations will be characterized by the most sensitive BiPo detector. External radon tightness and internal radon emanation have been studied to ensure a very low level in the tracker with very sensitive complementary detectors: diffusion apparatus, concentration line and emanation tanks. The construction of the first detector, called the demonstrator, has started in 2012. Studying 7 kg of {sup 82}Se, the demonstrator will reach the NEMO-3 sensitivity in only 5 months and improve it by at least a factor 6 in 2.5 years. Underground installation will start fall 2014 and physics data taking should start by summer 2015.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulations of Brady's-Type Fault Undergoing CO2 Push-Pull: Pressure-Transient and Sensitivity Analysis

Input and output files used for fault characterization through numerical simulation using iTOUGH2. The synthetic data for the push period are generated by running a forward simulation (input parameters are provided in iTOUGH2 Brady GF6 Input Parameters.txt [InvExt6i.txt]). In general, the permeability of the fault gouge, damage zone, and matrix are assumed to be unknown. The input and output files are for the inversion scenario where only pressure transients are available at the monitoring well located 200 m above the injection well and only the fault gouge permeability is estimated. The input files are named InvExt6i, INPUT.tpl, FOFT.ins, CO2TAB, and the output files are InvExt6i.out, pest.fof, and pest.sav (names below are display names). The table graphic in the data files below summarizes the inversion results, and indicates the fault gouge permeability can be estimated even if imperfect guesses are used for matrix and damage zone permeabilities, and permeability anisotropy is not taken into account.

15 GEOTHERMAL ENERGY↗

Coulomb excitation of a {sup 242}Am isomeric target : E2, E3 strengths, rotational alignment, and collective enhancement.

A 98% pure {sup 242m}Am (K=5{sup -}, t{sub 1/2} = 141 years) isomeric target was Coulomb excited with a 170.5-MeV {sup 40}Ar beam. The selectivity of Coulomb excitation, coupled with the sensitivity of Gammasphere plus CHICO, was sufficient to identify 46 new states up to spin 18 {h_bar} in at least four rotational bands; 11 of these new states lie in the isomer band, 13 in a previously unknown yrast K{sup {pi}} = 6{sup -} rotational band, and 13 in a band tentatively identified as the predicted yrast K{sup {pi}} = 5{sup +} band. The rotational bands based on the K{sup {pi}} = 5{sup -} isomer and the 6{sup -} bandhead were populated by Coulomb excitation with unexpectedly equal cross sections. The {gamma}-ray yields are reproduced by Coulomb excitation calculations using a two-particle plus rotor model (PRM), implying nearly complete {Delta}K = 1 mixing of the two almost-degenerate rotational bands, but recovering the Alaga rule for the unperturbed states. The degeneracy of the 5{sup -} and 6{sup -} bands allows for precise determination of the mixing interaction strength V, which approaches the strong-mixing limit; this agrees with the 50% attenuation of the Coriolis matrix element assumed in the model calculations. The fractional admixture of the I{sub K}{sup {pi}} = 6{sub 6{sup -}} state in the nominal 6{sub 5{sup -}} isomer band state is measured within the PRM as 45.6{sub -1.1}{sup +0.3}%. The E2 and M1 strengths coupling the 5{sup -} and 6{sup -} bands are enhanced significantly by the mixing, while E1 and E2 couplings to other low-K bands are not measurably enhanced. The yields of the 5{sup +} band are reproduced by an E3 strength of {approx}15 W.u., competitive with the interband E2 strength. Alignments of the identified two-particle Nilsson states in {sup 242}Am are compared with the single-particle alignments in {sup 241}Am.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Chiral matrix model of the semi-QGP in QCD

Previously, a matrix model of the region near the transition temperature, in the “semi”quark gluon plasma, was developed for the theory of SU(3) gluons without quarks. In this paper we develop a chiral matrix model applicable to QCD by including dynamical quarks with 2+1 flavors. This requires adding a nonet of scalar fields, with both parities, and coupling these to quarks through a Yukawa coupling, y. Treating the scalar fields in mean field approximation, the effective Lagrangian is computed by integrating out quarks to one loop order. As is standard, the potential for the scalar fields is chosen to be symmetric under the flavor symmetry of SU (3) L × SU(3) R × Z (3) A , except for a term linear in the current quark mass, m qk . In addition, at a nonzero temperature T it is necessary to add a new term, ~ m qk T 2 . The parameters of the gluon part of the matrix model are identical to those for the pure glue theory without quarks. The parameters in the chiral matrix model are fixed by the values, at zero temperature, of the pion decay constant and the masses of the pions, kaons, η , and η' . The temperature for the chiral crossover at T$χ$ = 155 MeV is determined by adjusting the Yukawa coupling y . We find reasonable agreement with the results of numerical simulations on the lattice for the pressure and related quantities. In the chiral limit, besides the divergence in the chiral susceptibility there is also a milder divergence in the susceptibility between the Polyakov loop and the chiral order parameter, with critical exponent β $-$ 1 . We compute derivatives with respect to a quark chemical potential to determine the susceptibilities for baryon number, the $χ$ 2n . Especially sensitive tests are provided by $χ$ 4 $-$ $χ$ 2 and by $χ$ 6 , which changes in sign about T$χ$ . In conclusion, the behavior of the susceptibilities in the chiral matrix model strongly suggests that as the temperature increases from T$χ$ , that the transition to deconfinement is significantly quicker than indicated by the measurements of the (renormalized) Polyakov loop on the lattice.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Carbon Nanoparticles and Graphene Nanosheets as MALDI Matrices in Glycomics: a New Approach to Improve Glycan Profiling in Biological Samples

Glycomics continues to be a highly dynamic and interesting research area due to the need to comprehensively understand the biological attributes of glycosylation in many important biological functions such as the immune response, cell development, cell differentiation/adhesion, and host-pathogen interactions. Although matrix-assisted laser desorption ionization (MALDI) mass spectrometry (MS) has proven to be suitable for glycomic profiling studies, there is a need for improved sensitivity in the detection of native glycans, which ionize inefficiently. In this study, we investigated the efficiencies of graphene nanosheets (GNs) and carbon nanoparticles (CNPs) as MALDI matrices and co-matrices in glycan profiling. Our results indicated an enhancement of signal intensity by several orders of magnitude upon using GNs and CNPs in MALDI analysis of N-glycans derived from a variety of biological samples. Interestingly, increasing the amounts of CNPs and GNs improved not only the signal intensities but also prompted in-source decay (ISD) fragmentations, which produced extensive glycosidic and cross-ring cleavages. Our results indicated that the extent of ISD fragmentation could be modulated by CNP and GN concentrations, to obtain MS{sup 2} and pseudo-MS{sup 3} spectra. The results for glycan profiling in high salt solutions confirmed high salt-tolerance capacities for both CNPs and GNs. Finally, the results showed that by using CNPs and GNs as co-matrices, DHB crystal formation was more homogeneous which improved shot-to-shot reproducibility and sensitivity. .

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Measurements of W/Z production with the ATLAS detector

W and Z boson production have been measured in the electron, muon and tau decay channels at the LHC with the ATLAS detector. Total and differential cross sections, defined in terms of the decay lepton kinematics, have been measured as a function of rapidity and transverse momentum. Ratios of the cross sections demonstrate sensitivity to lepton universality. The kinematic distributions constrain parton densities and QCD calculations, including resummations of soft gluon radiation and the matching of NLO matrix elements (or high multiplicity tree-level matrix elements) to parton shower approximations. The polarization of W bosons is also measured, as, for the first time, is the polarization of the tau lepton in W → τν decays.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Non-unitary leptonic mixing and CP-violation

Some theories of new physics accounting for neutrino masses can give rise to a low-energy non-unitary leptonic mixing matrix. It is shown that the CP-asymmetries in the {nu}{sub {mu}}{yields}{nu}{sub {tau}} channel are an excellent probe of such new physics. In adition, we clarify the relationship betweeen our framework and the so called ''non-standard neutrino interactions'' scenarios: the sensitivities explored here apply as well to such constructions, except for extremely fine-tuned cancellations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Targeted deletion of hepatocyte Ikk{beta} confers growth advantages

Mice lacking hepatocyte IKK{beta} (Ikk{beta}{sup {delta}}{sup hep}) are defective in TNF{alpha}-activation of hepatocellular transcription factor NF-{kappa}B, and highly susceptible to hepatotoxicity. Following diethylnitrosamine (DEN) exposure, Ikk{beta}{sup {delta}}{sup hep} mice develop more hepatocellular carcinoma (HCC) than control mice due partly to enhanced DEN-induced hepatocyte death. Here we show that Ikk{beta}{sup {delta}}{sup hep} hepatocytes display growth advantages over normal hepatocytes consisting of precocious PCNA and cyclin D1 expression during liver regeneration (shortened hepatocyte G{sub 0} {yields} G{sub 1} transitions), and enhanced recovery efficiency, cyclin D1 expression and cell proliferation after plating. Ex vivo deletion of Ikk{beta} also accelerates hepatocyte growth. Ikk{beta}{sup {delta}}{sup hep} hepatocyte proliferative responses show heightened sensitivity to TGF{alpha} and TNF{alpha}, and heightened expression of fibronectin, collagens I/III, nidogen, {beta}-actin and integrin {beta}1 mRNAs. These findings suggest that altered mitogen signaling and expression of extracellular matrix and its associated components underlie growth advantages. Increased HCC development in Ikk{beta}{sup {delta}}{sup hep} mice may also be caused by growth advantages of surviving Ikk{beta}-deleted hepatocytes.

60 APPLIED LIFE SCIENCES↗

Measurements and interpretations of W ± Z production cross-sections in pp collisions at $\sqrt{s}=13$ TeV with the ATLAS detector

Measurements of integrated and differential cross-sections for W ± Z production in proton-proton collisions are presented. The data collected by the ATLAS detector at the Large Hadron Collider from 2015 to 2018 at a centre-of-mass energy of $\sqrt{s}=13$ TeV are used, corresponding to an integrated luminosity of 140 fb −1 . The W ± Z candidate events are reconstructed using leptonic decay modes of the gauge bosons into electrons or muons. The integrated cross-section per lepton flavour for the production of W ± Z is measured in the detector fiducial region with a relative precision of 4%. The measured value is compared with the Standard Model prediction at a precision of up to next-to-next-to-leading-order in QCD and next-to-leading-order in electroweak. Cross-sections for W + Z and W − Z production and their ratio are presented. The W ± Z production is also measured differentially as functions of various kinematic variables, including new observables sensitive to CP-violation effects. All measurements are compared with state-of-the-art Standard Model predictions from fixed-order calculations or Monte Carlo generators based on next-to-leading-order matrix elements interfaced with parton showers. An effective field theory interpretation of the measurements is performed, considering both CP-conserving and CP-violating dimension-6 operators modifying the W ± Z production. In the absence of observed deviations from the Standard Model, limits on CP-conserving Wilson coefficients are extracted using the transverse mass of the W ± Z system. For CP-violating coefficients a machine learning approach is used to construct an observable with enhanced sensitivity to CP-violation effects.

hadron-hadron scattering↗

Measurement of single top quark production in the tau+jets channnel using boosted decision trees at D0

The top quark is the heaviest known matter particle and plays an important role in the Standard Model of particle physics. At hadron colliders, it is possible to produce single top quarks via the weak interaction. This allows a direct measurement of the CKM matrix element V tb and serves as a window to new physics. The first direct measurement of single top quark production with a tau lepton in the final state (the tau+jets channel) is presented in this thesis. The measurement uses 4.8 fb -1 of Tevatron Run II data in p$\bar{p}$ collisions at √s = 1.96 TeV acquired by the D0 experiment. After selecting a data sample and building a background model, the data and background model are in good agreement. A multivariate technique, boosted decision trees, is employed in discriminating the small single top quark signal from a large background. The expected sensitivity of the tau+jets channel in the Standard Model is 1.8 standard deviations. Using a Bayesian statistical approach, an upper limit on the cross section of single top quark production in the tau+jets channel is measured as 7.3 pb at 95% confidence level, and the cross section is measured as 3.4 -1.8 +2.0 pb. The result of the single top quark production in the tau+jets channel is also combined with those in the electron+jets and muon+jets channels. The expected sensitivity of the electron, muon and tau combined analysis is 4.7 standard deviations, to be compared to 4.5 standard deviations in electron and muon alone. The measured cross section in the three combined final states is σ(p$\bar{p}$ → tb + X,tqb + X) = 3.84 -0.83 +0.89 pb. A lower limit on |V tb | is also measured in the three combined final states to be larger than 0.85 at 95% confidence level. These results are consistent with Standard Model expectations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Monitoring PAI-1 and VEGF Levels in 6 Human Squamous Cell Carcinoma Xenografts During Fractionated Irradiation

Purpose: Previous studies have shown that the plasminogen activator inhibitor type-1 (PAI-1) and vascular endothelial growth factor (VEGF) are regulated by hypoxia and irradiation and are involved in neoangiogenesis. The aim of this study was to determine in vivo whether changes in PAI-1 and VEGF during fractionated irradiation could predict for radiation resistance. Methods and Materials: Six xenografted tumor lines from human squamous cell carcinomas (HSCC) of the head and neck were irradiated with 0, 3, 5, 10, and 15 daily fractions of 2 Gy. The PAI-1 and VEGF antigen levels in tumor lysates were determined by enzyme-linked immunosorbent assay kits. The amounts of PAI-1 and VEGF were compared with the dose to cure 50% of tumors (TCD{sub 50}). Colocalization of PAI-1, pimonidazole (hypoxia), CD31 (endothelium), and Hoechst 33342 (perfusion) was examined by immunofluorescence. Results: Human PAI-1 and VEGF (hVEGF) expression levels were induced by fractionated irradiation in UT-SCC-15, UT-SCC-14, and UT-SCC-5 tumors, and mouse VEGF (msVEGF) was induced only in UT-SCC-5 tumors. High hVEGF levels were significantly associated with radiation sensitivity after 5 fractions (P=.021), and high msVEGF levels were significantly associated with radiation resistance after 10 fractions (P=.007). PAI-1 staining was observed in the extracellular matrix, the cytoplasm of fibroblast-like stroma cells, and individual tumor cells at all doses of irradiation. Colocalization studies showed PAI-1 staining close to microvessels. Conclusions: These results indicate that the concentration of tumor-specific and host-specific VEGF during fractionated irradiation could provide considerably divergent information for the outcome of radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ex vivo cultures of glioblastoma in three-dimensional hydrogel maintain the original tumor growth behavior and are suitable for preclinical drug and radiation sensitivity screening

Identification of new drugs and predicting drug response are major challenges in oncology, especially for brain tumors, because total surgical resection is difficult and radiation therapy or chemotherapy is often ineffective. With the aim of developing a culture system close to in vivo conditions for testing new drugs, we characterized an ex vivo three-dimensional culture system based on a hyaluronic acid-rich hydrogel and compared it with classical two-dimensional culture conditions. U87-MG glioblastoma cells and seven primary cell cultures of human glioblastomas were subjected to radiation therapy and chemotherapy drugs. It appears that 3D hydrogel preserves the original cancer growth behavior and enables assessment of the sensitivity of malignant gliomas to radiation and drugs with regard to inter-tumoral heterogeneity of therapeutic response. It could be used for preclinical assessment of new therapies. - Highlights: • We have compared primary glioblastoma cell culture in a 2D versus 3D-matrix system. • In 3D morphology, organization and markers better recapitulate the original tumor. • 3D-matrix culture might represent a relevant system for more accurate drug screening.

60 APPLIED LIFE SCIENCES↗

Additive manufacturing of metal matrix composites

Although Metal matrix composites (MMCs) are superior to most sought-after metallic alloys, their challenging fabricability has limited their widespread use in bulk-form applications. Among the many advanced fabrication techniques, Additive Manufacturing (AM), owing to its unique capabilities to produce near-net shapes, has drawn significant traction in the past two decades, especially for materials that are difficult to process using traditional methods. However, unlike pure metal/alloy systems, MMCs are highly sensitive to the processing conditions prevailing in AM techniques due to factors such as the high melting point of reinforcement particles and the potential for in-situ reactions. Therefore, it may be a while before metal matrix composites are commercially produced via AM. This review will discuss the current state-of-the-art design, fabricability, and performance of various additively manufactured MMCs. A particular focus will be on microstructural evolution and microstructure-property relationships. The most employed AM techniques, such as directed energy deposition, powder bed fusion, binder jetting, sheet lamination, and solid-state friction stir processing, are fundamentally different in terms of thermo-kinetics, forming the perspective for this review. A detailed comparison of microstructural evolution and process parameter optimization, including feedstock preparation methods and the role of machine learning and modeling among the different AM processes, is also presented. Finally, a critical evaluation of emerging AM technologies for MMCs is also provided, highlighting their potential advantages and challenges.

36 - MATERIALS SCIENCE↗

Sensitivity and reliability of key electrochemical markers for detecting lithium plating during extreme fast charging

Lithium plating is one of the key challenges for enabling extreme fast charging (XFC, ≤10 to 15 min charging at ≥6C) in graphite-based lithium-ion batteries. Significant R&D effort has been focused on how to mitigate Li plating. Parallel effort is also being devoted to developing methods to detect Li plating when and if it happens during fast charging. In that regard, electrochemical (EC) signature-based detection techniques are less resource intensive, more convenient, and more practical from an end-user application perspective. However, a comprehensive understanding of key plating related EC signatures for extreme fast charging is presently unavailable. In particular, there exist distinct issues of unreliability with key plating-related EC signatures—e.g., incremental capacity (dQ.dV -1 ), differential OCV (dOCV.dt -1 ), end of lithiation (EOL) rest voltage—at XFC conditions, and the underlying reasons have not been explored and identified methodically. Using a comprehensive test matrix and XFC conditions with Li/graphite half cells, this article highlights the unreliability issues associated with the EC Li plating diagnostics and explains the underlying root cause. This study finds distinct sensitivity and unreliability issues with plating related dQ.dV -1 , dOCV.dt -1 , and EOL rest voltage signatures with charging rates. Furthermore, the complex interaction between graphite and plated Li that happens through multiple competing mechanisms —Li stripping and chemical intercalation— at different charging rates is at the core of the sensitivity and unreliability issue.

25 ENERGY STORAGE↗

Comparative study of 0° X-cut and Y + 36°-cut lithium niobate high-voltage sensing

A comparison study between Y + 36° and 0° X-cut lithium niobate (LiNbO{sub 3}) was performed to evaluate the influence of crystal cut on the acoustic propagation to realize a piezoelectric high-voltage sensor. The acoustic time-of-flight for each crystal cut was measured when applying direct current (DC), alternating current (AC), and pulsed voltages. Results show that the voltage-induced shift in the acoustic wave propagation time scaled quadratically with voltage for DC and AC voltages applied to X-cut crystals. For the Y + 36° crystal, the voltage-induced shift scales linearly with DC voltages and quadratically with AC voltages. When applying 5 μs voltage pulses to both crystals, the voltage-induced shift scaled linearly with voltage. For the Y + 36° cut, the voltage-induced shift from applying DC voltages ranged from 10 to 54 ps and 35 to 778 ps for AC voltages at 640 V over the frequency range of 100 Hz–100 kHz. Using the same conditions as the Y + 36° cut, the 0° X-cut crystal sensed a shift of 10–273 ps for DC voltages and 189–813 ps for AC voltage application. For 5 μs voltage pulses, the 0° X-cut crystal sensed a voltage induced shift of 0.250–2 ns and the Y + 36°-cut crystal sensed a time shift of 0.115–1.6 ns. This suggests a frequency sensitive response to voltage where the influence of the crystal cut was not a significant contributor under DC, AC, or pulsed voltage conditions. The measured DC data were compared to a 1-D impedance matrix model where the predicted incremental length changed as a function of voltage. When the voltage source error was eliminated through physical modeling from the uncertainty budget, the combined uncertainty of the sensor (within a 95% confidence interval) decreased to 0.0033% using a Y + 36°-cut crystal and 0.0032% using an X-cut crystal for all the voltage conditions used in this experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗