Search NASA⌕ Search

SEARCH · Search NASA

Results for “Shoulders”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

455 records · Page 26

Next Generation Exercise Device (NGED): Advancing Exercise Capabilities for Future Space Missions Through Biomechanical Modeling

BACKGROUND As space exploration extends to long-duration missions on the Moon and Mars, maintaining astronaut health and fitness becomes increasingly critical. The Next Generation Exercise Device (NGED), developed and tested by the HumanWorks Lab in NASA Johnson Space Center's (JSC) Software, Robotics, and Simulation Division, aims to address this challenge through innovative approaches. This study presents the development and evaluation of an NGED system, focusing on its adaptability to various mission scenarios, including prospective use in a Lunar Pressurized Rover (LPR). Central to this project is the application of biomechanical modeling to optimize exercise efficacy and safety in microgravity and partial gravity environments. The project is a collaborative effort with the Human Health and Performance group at Johnson Space Center, ensuring a comprehensive approach to astronaut well-being that integrates biomechanical principles with practical exercise solutions. The NGED represents the next generation of exercise capabilities for missions in space, on the Moon and Mars, with a specific focus on applications such as the LPR. METHODS AND RESULTS Data collection for NGED development was conducted with two motor-driven Beyond Power Voltra I [1] systems and a custom test structure to allow placement of the cable-based devices on the ground, at shoulder height, and overhead. The collection was performed in JSC’s Prototype Immersive Technology (PIT) Lab, utilizing an OptiTrack motion capture system and AMTI force platform, to enable detailed biomechanical analysis via OpenSim [2,3]. Motion capture data were collected for three subjects representing different body types and statures. The marker set used was an enhanced version of the full-body Plug-in Gait marker set [4], with additional markers strategically placed for the primary objective of informing exercise volume requirements. Subjects performed a series of 17 exercises, carefully selected to engage various muscle groups, including novel spaceflight exercises such as skiing (ergometer style), lateral pulldowns, wood chops, triceps extensions, and flies, with load variations ranging from 10 to 90 pounds to maintain kinematic form. This comprehensive approach allowed for a thorough evaluation of the NGED's performance across a wide range of motions and loads. The biomechanical modeling and analysis were conducted using a modified OpenSim Full Body Rajagopal Model [4,5] and also scaled to the maximum and minimum anthropometry provided in NASA-STD-3001 [6]. Volumetric convex hulls were generated based on model marker trajectories and aggregated into geometric assemblies. These can be placed in models of vehicle designs to assess fit to protect for exercise as well as to adapt NGED exercise to fit available space. Preliminary findings from the collection indicate that the NGED prototype demonstrates significant adaptability across varying user anthropometrics and exercise types. The device showed consistent performance in load-bearing exercises, with subjects able to perform exercises effectively while maintaining proper biomechanical form. CONCLUSION NGED represents a forward-looking advancement in exercise capabilities for future space missions. In the future, this system can be used to capture valuable metrics (e.g., isometric mid-thigh pull for force output measurements, assessments of postural muscle strength, overall isometric strength). Its versatility in accommodating various exercises and user physiques, coupled with the ability to provide targeted biomechanical loading, makes it a promising approach for maintaining astronaut health during long-duration missions to the Moon and Mars. Future work will focus on refining the NGED based on initial biomechanical findings, leveraging the detailed insights provided by motion capture and analysis techniques. Particular emphasis will be placed on optimizing its use within the confined spaces of a LPR and other space habitats. This work contributes significantly to NASA's goals of supporting human health and performance in deep space exploration, paving the way for sustainable long-term presence beyond Low Earth Orbit through advanced, biomechanically-informed exercise solutions.

C Wang↗

Human Spaceflight Applications of Novel Miniature X-Ray Technologies

INTRODUCTION: Radiography (XR) has long been a cornerstone of terrestrial medical imaging, though it has not yet been used in the spaceflight environment. Medical systems for human spaceflight missions are constrained by mass, volume, and power, and until recently, XR systems have been considered too large and power-consuming for spaceflight diagnostic and therapeutic applications. However, the rise of commercial spaceflight and NASA’s refocused efforts on returning crews to the Moon for long-duration missions have introduced a higher degree of medical risk to human spaceflight and require a re-evaluation when optimizing medical system design. Over the last decade, XR devices have miniaturized while maintaining good diagnostic and therapeutic sensitivity and specificity, making new in-flight medical and non-medical XR applications a possibility. Initial research identified several medical conditions where miniature XR would be beneficial for the diagnosis and/or management of medical conditions arising in space, though a more in-depth analysis is required to identify whether XR may add value to the management of such conditions. With this presentation, we aim to introduce the potential utility of miniature XR, review prior work highlighting where XR may be beneficial, and evaluate how miniature XR may reduce medical risk in human spaceflight missions. METHODS: IMPACT (Informing Mission Planning via Analysis of Complex Tradespaces) is a risk assessment tool developed by NASA to advance exploration mission medical system design by quantitatively estimating mission medical risk. IMPACT v1.0 includes a novel evidence library baselined to exploration environments, an expanded list of 119 medical conditions, medical capabilities and resources critical for management of these medical conditions, and the ability for rapid and iterative analysis in the setting of modifiable design reference missions (DRMs). Our first analysis identified which of the 119 medical conditions XR had diagnostic or therapeutic utility for. Subject matter experts (SMEs) recorded which XR views would be performed under ideal terrestrial circumstances for diagnosis/management of each condition, as well as which views are pragmatic for spaceflight limitations. A second analysis utilized IMPACT to identify significant conditions that contribute greatest to medical risk during a notional long-duration Lunar orbit and Lunar surface DRM. Medical system risk estimates include loss of crew life (LOCL), need for return to definitive care (RTDC; medical evacuation), and an estimate of crew task time affected (TTA). Using a standardized semi-quantitative scoring methodology, a deeper evaluation of each of the most significant medical conditions was performed. Data from both of these separate analyses were used to hypothesize what ideal and pragmatic XR studies may impact clinical management of the most significant conditions predicted to lead to medical risk. RESULTS: Approximately 1/3 of the IMPACT conditions were identified as being more effectively or comprehensively assessed or treated with the addition of miniature XR technology. The resulting conditions benefitting diagnostically and therapeutically from XR are revealed, as well as the ideal and pragmatic XR views and medical procedures benefitting from XR. The conditions of clinical significance and those most contributing to risk are also displayed. Among the conditions that contribute greatest to LOCL, four conditions for which XR may improve the diagnosis and management of include: decompression sickness, traumatic shock, dental abscess, and respiratory failure. Among conditions that contributed to RTDC, the evaluation and management of wrist fracture is likely improved by XR. For conditions leading to crew TTA, evaluation and management of EVA shoulder injuries, upper and lower extremity strains, back strains, and EVA hand injuries are likely improved by XR. DISCUSSION: Miniature XR in spaceflight has the potential to improve the evaluation and management of a substantial portion of conditions that most contribute to medical risk. This presentation is an introduction to the possibilities miniature XR provides for future human spaceflight missions and subsequent presenters will expand on potential applications in more detail. LEARNING OBJECTIVES: 1) Understand the previous limitations of using radiography in the management of spaceflight medical conditions; 2) Evaluate the findings from the IMPACT tool analysis, which allows quantification of the benefit miniature XR could provide for managing high-risk medical conditions in long-duration lunar orbit and surface missions, focusing on improvements in crew health outcomes; 3) Analyze case studies where miniature XR technology could reduce the medical risks associated with spaceflight missions, specifically in diagnosing and managing conditions such as decompression sickness, traumatic shock, and EVA-related injuries.

A Anderson↗

Evaluation of Magnet Configurations for Magnetohydrodynamic Trajectory Control during Planetary Entry

Magnetohydrodynamics is a phenomenon that can be harnessed during planetary entry to augment aerodynamic drag and may enable higher mass payloads to safely reach the surface. The magnetohydrodynamic force is quantified over a wide range of freestream conditions using computational fluid dynamics results from a previous study. The force is calculated for an array of small electromagnets, a large non-superconducting magnet, a large superconducting magnet, and a uniform field. The superconducting magnet produces a magnetohydrodynamic force within an order of magnitude of aerodynamic drag for velocities higher than 10 km/s, indicating that it may have a reasonable impact on the trajectory for some cases. The array of small magnets and non-superconducting magnet produced a magnetohydrodynamic force that is less than 1% of the aerodynamic drag, so their magnetic fields are not strong enough to affect an entry trajectory. Additionally, the magnet placement plays an important role in magnetohydrodynamic force magnitude, with a magnet located near the shoulder producing approximately eight times more force than a magnet placed on the axis of symmetry. A mass and power budget for each magnet configuration is given assuming current state-of-the-art magnet technology. This study also discusses implementation challenges for each type of magnet on a spacecraft.

Magnetohydrodynamics↗

Coordinated turn-and-reach movements. II. Planning in an external frame of reference

The preceding study demonstrated that normal subjects compensate for the additional interaction torques generated when a reaching movement is made during voluntary trunk rotation. The present paper assesses the influence of trunk rotation on finger trajectories and on interjoint coordination and determines whether simultaneous turn-and-reach movements are most simply described relative to a trunk-based or an external reference frame. Subjects reached to targets requiring different extents of arm joint and trunk rotation at a natural pace and quickly in normal lighting and in total darkness. We first examined whether the larger interaction torques generated during rapid turn-and-reach movements perturb finger trajectories and interjoint coordination and whether visual feedback plays a role in compensating for these torques. These issues were addressed using generalized Procrustes analysis (GPA), which attempts to overlap a group of configurations (e.g., joint trajectories) through translations and rotations in multi-dimensional space. We first used GPA to identify the mean intrinsic patterns of finger and joint trajectories (i.e., their average shape irrespective of location and orientation variability in the external and joint workspaces) from turn-and-reach movements performed in each experimental condition and then calculated their curvatures. We then quantified the discrepancy between each finger or joint trajectory and the intrinsic pattern both after GPA was applied individually to trajectories from a pair of experimental conditions and after GPA was applied to the same trajectories pooled together. For several subjects, joint trajectories but not finger trajectories were more curved in fast than slow movements. The curvature of both joint and finger trajectories of turn-and-reach movements was relatively unaffected by the vision conditions. Pooling across speed conditions significantly increased the discrepancy between joint but not finger trajectories for most subjects, indicating that subjects used different patterns of interjoint coordination in slow and fast movements while nevertheless preserving the shape of their finger trajectory. Higher movement speeds did not disrupt the arm joint rotations despite the larger interaction torques generated. Rather, subjects used the redundant degrees of freedom of the arm/trunk system to achieve similar finger trajectories with differing joint configurations. We examined finger movement patterns and velocity profiles to determine the frame of reference in which turn-and-reach movements could be most simply described. Finger trajectories of turn-and-reach movements had much larger curvatures and their velocity profiles were less smooth and less bell-like in trunk-based coordinates than in external coordinates. Taken together, these results support the conclusion that turn-and-reach movements are controlled in an external frame of reference.

NASA Discipline Neuroscience↗

Coordinated turn-and-reach movements. I. Anticipatory compensation for self-generated coriolis and interaction torques

When reaching movements involve simultaneous trunk rotation, additional interaction torques are generated on the arm that are absent when the trunk is stable. To explore whether the CNS compensates for such self-generated interaction torques, we recorded hand trajectories in reaching tasks involving various amplitudes and velocities of arm extension and trunk rotation. Subjects pointed to three targets on a surface slightly above waist level. Two of the target locations were chosen so that a similar arm configuration relative to the trunk would be required for reaching to them, one of these targets requiring substantial trunk rotation, the other very little. Significant trunk rotation was necessary to reach the third target, but the arm's radial distance to the body remained virtually unchanged. Subjects reached at two speeds-a natural pace (slow) and rapidly (fast)-under normal lighting and in total darkness. Trunk angular velocity and finger velocity relative to the trunk were higher in the fast conditions but were not affected by the presence or absence of vision. Peak trunk velocity increased with increasing trunk rotation up to a maximum of 200 degrees /s. In slow movements, peak finger velocity relative to the trunk was smaller when trunk rotation was necessary to reach the targets. In fast movements, peak finger velocity was approximately 1.7 m/s for all targets. Finger trajectories were more curved when reaching movements involved substantial trunk rotation; however, the terminal errors and the maximal deviation of the trajectory from a straight line were comparable in slow and fast movements. This pattern indicates that the larger Coriolis, centripetal, and inertial interaction torques generated during rapid reaches were compensated by additional joint torques. Trajectory characteristics did not vary with the presence or absence of vision, indicating that visual feedback was unnecessary for anticipatory compensations. In all reaches involving trunk rotation, the finger movement generally occurred entirely during the trunk movement, indicating that the CNS did not minimize Coriolis forces incumbent on trunk rotation by sequencing the arm and trunk motions into a turn followed by a reach. A simplified model of the arm/trunk system revealed that additional interaction torques generated on the arm during voluntary turning and reaching were equivalent to < or =1.8 g (1 g = 9.81 m/s(2)) of external force at the elbow but did not degrade performance. In slow-rotation room studies involving reaching movements during passive rotation, Coriolis forces as small as 0.2 g greatly deflect movement trajectories and endpoints. We conclude that compensatory motor innervations are engaged in a predictive fashion to counteract impending self-generated interaction torques during voluntary reaching movements.

NASA Discipline Neuroscience↗