Search NASA⌕ Search

SEARCH · Search NASA

Results for “Small”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Photoexcited Small Polaron Formation in Goethite (α-FeOOH) Nanorods Probed by Transient Extreme Ultraviolet Spectroscopy

Small polaron formation limits the mobility and lifetimes of photoexcited carriers in metal oxides. As the ligand field strength increases, the carrier mobility decreases, but the effect on the photoexcited small polaron formation is still unknown. Extreme ultraviolet transient absorption spectroscopy is employed to measure small polaron formation rates and probabilities in goethite (α-FeOOH) crystalline nanorods at pump photon energies from 2.2 to 3.1 eV. The measured polaron formation time increases with excitation photon energy from 70 ± 10 fs at 2.2 eV to 350 ± 30 fs at 2.6 eV, whereas the polaron formation probability (85 ± 10%) remains constant. By comparison to hematite (α-Fe 2 O 3 ), an oxide analogue, the role of ligand composition and metal center density in small polaron formation time is discussed. Here, this work suggests that incorporating small changes in ligands and crystal structure could enable the control of photoexcited small polaron formation in metal oxides.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Small-Scale Irrigation: Improving Food Security under Changing Climate and Water Resource Conditions in Ethiopia

We develop a new systems modeling tool that integrates knowledge from hydrology, agriculture, and economics to understand the effect of small-scale irrigation on food security and groundwater sustainability in Ethiopia. Irrigation is an effective tool to mitigate climate impacts and improve agricultural yields. Small-scale irrigation, such as decentralized groundwater irrigation, is well suited for developing countries where smallholder farming communities are widely dispersed and can only afford small infrastructure investment. We study the underlying interdependencies between food and water systems in Ethiopia, where small-holder agriculture is the foundation of the nation’s economy and climate variability has led to great challenges to its food security. Our coupled market and crop model with groundwater module captures the interdependencies of climate, water availability (including irrigation), crop yield, farmland allocation, crop production, transport and consumption based on a system approach across multiple spatial scales. We study the implication of small-scale irrigation to Ethiopia’s food security and water resource conditions as a “what-if” question by comparing an irrigation scenario to the calibrated baseline in 2015, a year of significant drought and crop failure over a large portion of Ethiopia. Our model offers fresh insights into geographic disparities in outcomes that are driven by baseline climate variability, soil fertility, and market conditions. In general, we find that small-scale irrigation can potentially improve food security through increases in food consumption, but it requires policy support to direct the increases of production to domestic consumption while maintaining a sustainable groundwater condition. By using Ethiopia as an example, we show the strength of our model to study how water infrastructure resources support critical functions and service in water and food systems.

Zhang, Ying↗

High longitudinal relaxivity of ultra-small gadolinium oxide prepared by microsecond laser ablation in diethylene glycol

Ultra-small gadolinium oxide (Gd{sub 2}O{sub 3}) can be used as T{sub 1}-weighted Magnetic Resonance Imaging (MRI) contrast agent own to its high longitudinal relaxivity (r{sub 1}) and has attracted intensive attention in these years. In this paper, ultra-small Gd{sub 2}O{sub 3} nanoparticles of 3.8 nm in diameter have been successfully synthesized by a microsecond laser ablating a gadolinium (Gd) target in diethylene glycol (DEG). The growth inhibition effect induced by the large viscosity of DEG makes it possible to synthesize ultra-small Gd{sub 2}O{sub 3} by laser ablation in DEG. The r{sub 1} value and T{sub 1}-weighted MR images are measured by a 3.0 T MRI spectroscope. The results show these nanoparticles with a high r{sub 1} value of 9.76 s{sup -1} mM{sup -1} to be good MRI contrast agents. We propose an explanation for the high r{sub 1} value of ultra-small Gd{sub 2}O{sub 3} by considering the decreasing factor (surface to volume ratio of the nanoparticles, S/V) and the increasing factor (water hydration number of the Gd{sup 3+} on Gd{sub 2}O{sub 3} surface, q), which offer a new look into the relaxivity studies of MRI contrast agents. Our research provides a new approach to preparing ultra-small Gd{sub 2}O{sub 3} of high r{sub 1} value by laser ablation in DEG and develops the understanding of high relaxivity of ultra-small Gd{sub 2}O{sub 3} MRI contrast agents.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Temperature effect on the small-to-large crossover lengthscale of hydrophobic hydration

The thermodynamics of hydration is expected to change gradually from entropic for small solutes to enthalpic for large ones. The small-to-large crossover lengthscale of hydrophobic hydration depends on the thermodynamic conditions of the solvent such as temperature, pressure, presence of additives, etc. We attempt to shed some light on the temperature dependence of the crossover lengthscale by using a probabilistic approach to water hydrogen bonding that allows one to obtain an analytic expression for the number of bonds per water molecule as a function of both its distance to a solute and solute radius. Incorporating that approach into the density functional theory, one can examine the solute size effects on its hydration over the entire small-to-large lengthscale range at a series of different temperatures. Knowing the dependence of the hydration free energy on the temperature and solute size, one can also obtain its enthalpic and entropic contributions as functions of both temperature and solute size. These functions can provide some interesting insight into the temperature dependence of the crossover lengthscale of hydrophobic hydration. The model was applied to the hydration of spherical particles of various radii in water in the temperature range from T = 293.15 K to T = 333.15 K. The model predictions for the temperature dependence of the hydration free energy of small hydrophobes are consistent with the experimental and simulational data on the hydration of simple molecular solutes. Three alternative definitions for the small-to-large crossover length-scale of hydrophobic hydration are proposed, and their temperature dependence is obtained. Depending on the definition and temperature, the small-to-large crossover in the hydration mechanism is predicted to occur for hydrophobes of radii from one to several nanometers. Independent of its definition, the crossover length-scale is predicted to decrease with increasing temperature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nonlinear buckling analyses of a small-radius carbon nanotube

Carbon nanotube (CNT) was first discovered by Sumio Iijima. It has aroused extensive attentions of scholars from all over the world. Over the past two decades, we have acquired a lot of methods to synthesize carbon nanotubes and learn their many incredible mechanical properties such as experimental methods, theoretical analyses, and computer simulations. However, the studies of experiments need lots of financial, material, and labor resources. The calculations will become difficult and time-consuming, and the calculations may be even beyond the realm of possibility when the scale of simulations is large, as for computer simulations. Therefore, it is necessary for us to explore a reasonable continuum model, which can be applied into nano-scale. This paper attempts to develop a mathematical model of a small-radius carbon nanotube based on continuum theory. An Isotropic circular cross-section, Timoshenko beam model is used as a simplified mechanical model for the small-radius carbon nanotube. Theoretical part is mainly based on modified couple stress theory to obtain the numerical solutions of buckling deformation. Meanwhile, the buckling behavior of the small radius carbon nanotube is simulated by Molecular Dynamics method. By comparing with the numerical results based on modified couple stress theory, the dependence of the small-radius carbon nanotube mechanical behaviors on its elasticity constants, small-size effect, geometric nonlinearity, and shear effect is further studied, and an estimation of the small-scale parameter of a CNT (5, 5) is obtained.

42 ENGINEERING↗

OBSERVATIONS OF A SMALL INTERPLANETARY MAGNETIC FLUX ROPE ASSOCIATED WITH A MAGNETIC RECONNECTION EXHAUST

A small interplanetary magnetic flux rope prior to an X-line magnetic reconnection exhaust was observed on 1998 March 25 at 1 AU. The X-line magnetic reconnection exhaust has been identified and reported by Gosling et al. The duration of this small magnetic flux rope is about 2 hr. We fitted the constant alpha force-free model to the observed magnetic fields. The model fitting results show that the spacecraft crosses the magnetic flux rope well away from the axis, with d {sub 0}/R {sub 0} being 0.76. The fitting results also show that its magnetic configuration is a right-handed helical flux rope, that the estimated field intensity at the axis is 16.3 nT, and that its diameter is 0.0190 AU. In addition, the axial direction of this rope is (theta = 6 deg., phi = 214 deg.), namely, this magnetic flux rope is lying nearly in the ecliptic plane. According to the geometric relation of the small flux rope and the reconnection exhaust, it is very possible that the small magnetic flux rope has a larger scale initially and comes from the corona; its magnetic fields are peeled off when moving from the Sun to the Earth and at last it reaches a small scale. Though magnetic reconnection can produce a flux-rope topology, in this case the X-line magnetic reconnection is destroying rather than generating the small magnetic flux rope.

79 ASTRONOMY AND ASTROPHYSICS↗

DETAILED ABUNDANCES OF STARS WITH SMALL PLANETS DISCOVERED BY KEPLER. I. THE FIRST SAMPLE

We present newly derived stellar parameters and the detailed abundances of 19 elements of seven stars with small planets discovered by NASA's Kepler Mission. Each star, save one, has at least one planet with a radius ≤1.6 R{sub ⊕}, suggesting a primarily rocky composition. The stellar parameters and abundances are derived from high signal-to-noise ratio, high-resolution echelle spectroscopy obtained with the 10 m Keck I telescope and High Resolution Echelle Spectrometer using standard spectroscopic techniques. The metallicities of the seven stars range from −0.32 to +0.13 dex, with an average metallicity that is subsolar, supporting previous suggestions that, unlike Jupiter-type giant planets, small planets do not form preferentially around metal-rich stars. The abundances of elements other than iron are in line with a population of Galactic disk stars, and despite our modest sample size, we find hints that the compositions of stars with small planets are similar to stars without known planets and with Neptune-size planets, but not to those of stars with giant planets. This suggests that the formation of small planets does not require exceptional host-star compositions and that small planets may be ubiquitous in the Galaxy. We compare our derived abundances (which have typical uncertainties of ≲0.04 dex) to the condensation temperature of the elements; a correlation between the two has been suggested as a possible signature of rocky planet formation. None of the stars demonstrate the putative rocky planet signature, despite at least three of the stars having rocky planets estimated to contain enough refractory material to produce the signature, if real. More detailed abundance analyses of stars known to host small planets are needed to verify our results and place ever more stringent constraints on planet formation models.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of small island characteristics using high resolution ECE and CER at DIII-D

Abstract The measurements using the high resolution electron cyclotron emission radiometry and the charge exchange and recombination spectroscopy are processed using analytic formulas to allow for the detection of islands as small as 1.9 cm. In contrast to large, saturated magnetic islands which are relatively well understood to be governed by the loss of bootstrap current inside the island, small islands are less well understood due to the difficulty of their accurate measurement in tokamaks. Here, ‘small’ islands are islands comparable in size to the ion banana width, which can be as small as 0.8 cm at DIII-D. The new measurement methods allow for the detection of small island widths when the predicted increase of mode frequency to match the Doppler shifted ion diamagnetic frequency is observed. Therefore, for the first time, the mode frequency increase can be unambiguously associated to the acceleration of the magnetic island propagation. Such association allows for a further development and validation of the much-debated theory of ion polarization currents, which is thought to govern the small island growth.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Regional epithelial cell diversity in the small intestine of pigs

Abstract Understanding regional distribution and specialization of small intestinal epithelial cells is crucial for developing methods to control appetite, stress, and nutrient uptake in swine. To establish a better understanding of specific epithelial cells found across different regions of the small intestine in pigs, we utilized single-cell RNA sequencing (scRNA-seq) to recover and analyze epithelial cells from duodenum, jejunum, and ileum. Cells identified included crypt cells, enterocytes, BEST4 enterocytes, goblet cells, and enteroendocrine (EE) cells. EE cells were divided into two subsets based on the level of expression of the EE lineage commitment gene, NEUROD1. NEUROD1hi EE cells had minimal expression of hormone-encoding genes and were dissimilar to EE cells in humans and mice, indicating a subset of EE cells unique to pigs. Recently discovered BEST4 enterocytes were detected in both crypts and villi throughout the small intestine via in situ staining, unlike in humans, where BEST4 enterocytes are found only in small intestinal villi. Proximal-to-distal gradients of expression were noted for hormone-encoding genes in EE cells and nutrient transport genes in enterocytes via scRNA-seq, demonstrating regional specialization. Regional gene expression in EE cells and enterocytes was validated via quantitative PCR (qPCR) analysis of RNA isolated from epithelial cells of different small intestinal locations. Though many genes had similar patterns of regional expression when assessed by qPCR of total epithelial cells, some regional expression was only detected via scRNA-seq, highlighting advantages of scRNA-seq to deconvolute cell type-specific regional gene expression when compared to analysis of bulk samples. Overall, results provide new information on regional localization and transcriptional profiles of epithelial cells in the pig small intestine.

Agriculture↗

Power Take-Off Design Study for a Small-Scale Oscillating Surge Wave Energy Converter for Powering the Blue Economy Applications

The power take-off (PTO) is an integral part of wave energy conversion, and the design process is nontrivial. Better PTOs, and better processes for selecting and designing PTO architectures for various applications, would benefit devices that assist in powering the blue economy by decreasing time and money spent on PTO design and increasing the overall energy capture performance of these devices. This paper chronicles the selection process of a PTO for a small-scale surge-type wave energy converter (WEC) for the purpose of informing future PTO selection processes. Three PTO architectures are evaluated in WEC-Sim: a hydraulic check valve PTO, a hydraulic active valving PTO, and a directly electrified PTO. Simple models of each PTO are constructed. Because a model for the small-scale device was initially unavailable, the PTOs are simulated on a large-scale device. The results are scaled down using Froude scaling and compared to results from directly simulating a small-scale model. Strong assumptions are made because this work is early in the design stages, and a coarse look at PTO options was desired. Specifically, the effectiveness of controls is investigated, along with the efficiency of energy conversion. However, energy capture is only part of the consideration; there are also logistic concerns to be considered when selecting a PTO. For example, components for large-scale WECs are so large and expensive that it may make sense to custom-build PTO components, but small-scale WECs would benefit from off-the-shelf availability because the cost of customization would be a significant portion of the total capital cost of deployment at a small scale. Submersible, off-the-shelf components are much easier to source for hydraulic PTOs. Because of highly effective controls, efficient energy conversion, and availability of marine-grade components, an active valving hydraulic PTO is selected for this small-scale surge-type WEC.

energy conversion/systems↗

Measuring output factors of small fields formed by collimator jaws and multileaf collimator using plastic scintillation detectors

Purpose: As the practice of using high-energy photon beams to create therapeutic radiation fields of subcentimeter dimensions (as in intensity-modulated radiotherapy or stereotactic radiosurgery) grows, so too does the need for accurate verification of beam output at these small fields in which standard practices of dose verification break down. This study investigates small-field output factors measured using a small plastic scintillation detector (PSD), as well as a 0.01 cm{sup 3} ionization chamber. Specifically, output factors were measured with both detectors using small fields that were defined by either the X-Y collimator jaws or the multileaf collimator (MLC). Methods: A PSD of 0.5 mm diameter and 2 mm length was irradiated with 6 and 18 MV linac beams. The PSD was positioned vertically at a source-to-axis distance of 100 cm, at 10 cm depth in a water phantom, and irradiated with fields ranging in size from 0.5x0.5 to 10x10 cm{sup 2}. The field sizes were defined either by the collimator jaws alone or by a MLC alone. The MLC fields were constructed in two ways: with the closed leaves (i.e., those leaves that were not opened to define the square field) meeting at either the field center line or at a 4 cm offset from the center line. Scintillation light was recorded using a CCD camera and an estimation of error in the median-filtered signals was made using the bootstrapping technique. Measurements were made using a CC01 ionization chamber under conditions identical to those used for the PSD. Results: Output factors measured by the PSD showed close agreement with those measured using the ionization chamber for field sizes of 2.0x2.0 cm{sup 2} and above. At smaller field sizes, the PSD obtained output factors as much as 15% higher than those found using the ionization chamber by 0.6x0.6 cm{sup 2} jaw-defined fields. Output factors measured with no offset of the closed MLC leaves were as much as 20% higher than those measured using a 4 cm leaf offset. Conclusions: The authors' results suggest that PSDs provide a useful and possibly superior alternative to existing dosimetry systems for small fields, as they are inherently less susceptible to volume-averaging and perturbation effects than larger, air-filled ionization chambers. Therefore, PSDs may provide more accurate small-field output factor determination, regardless of the collimation mechanism.

61 RADIATION PROTECTION AND DOSIMETRY↗

The effect of small field output factor measurements on IMRT dosimetry

Purpose: To evaluate how changes in the measured small field output factors affect the doses in intensity-modulated treatment planning. Methods: IMRT plans were created using Philips Pinnacle treatment planning system. The plans were optimized to treat a cylindrical target 2 cm in diameter and 2 cm in length. Output factors for 2 Multiplication-Sign 2 and 3 Multiplication-Sign 3 cm{sup 2} field sizes were changed by {+-}5%, {+-}10%, and {+-}20% increments from the baseline measurements and entered into the planning system. The treatment units were recommissioned in the treatment planning system after each modification of the output factors and treatment plans were reoptimized. All plans were delivered to a solid water phantom and dose measurements were made using an ionization chamber. The percentage differences between measured and computed doses were calculated. An Elekta Synergy and a Varian 2300CD linear accelerator were separately evaluated. Results: For the Elekta unit, decreasing the output factors resulted in higher measured than computed doses by 0.8% for -5%, 3.6% for -10%, and 8.7% for -20% steps. Increasing the output factors resulted in lower doses by 2.9% for +5%, 5.4% for +10%, and 8.3% for +20% steps. For the Varian unit no changes were observed for either increased or decreased output factors. Conclusions: The measurement accuracy of small field output factors are of importance especially when the treatment plan consists of small segments as in IMRT. The method proposed here could be used to verify the accuracy of the measured small field output factors for certain linear accelerators as well as to test the beam model. The Pinnacle treatment planning system model uses output factors as a function of jaw setting. Consequently, plans using the Elekta unit, which conforms the jaws to the segments, are sensitive to small field measurement accuracy. On the other hand, for the Varian unit, jaws are fixed and segments are modeled as blocked fields hence, the impact of small field output factors on IMRT monitor unit calculation is not evaluable by this method.

61 RADIATION PROTECTION AND DOSIMETRY↗

Output correction factors for nine small field detectors in 6 MV radiation therapy photon beams: A PENELOPE Monte Carlo study

Purpose: To determine detector-specific output correction factors,k{sub Q} {sub c{sub l{sub i{sub n}}}} {sub ,Q} {sub m{sub s{sub r}}} {sup f{sub {sup {sub c}{sub l}{sub i}{sub n}{sub {sup ,f{sub {sup {sub m}{sub s}{sub r}{sub ,}}}}}}}} in 6 MV small photon beams for air and liquid ionization chambers, silicon diodes, and diamond detectors from two manufacturers. Methods: Field output factors, defined according to the international formalism published byAlfonso et al. [Med. Phys. 35, 5179–5186 (2008)], relate the dosimetry of small photon beams to that of the machine-specific reference field; they include a correction to measured ratios of detector readings, conventionally used as output factors in broad beams. Output correction factors were calculated with the PENELOPE Monte Carlo (MC) system with a statistical uncertainty (type-A) of 0.15% or lower. The geometries of the detectors were coded using blueprints provided by the manufacturers, and phase-space files for field sizes between 0.5 × 0.5 cm{sup 2} and 10 × 10 cm{sup 2} from a Varian Clinac iX 6 MV linac used as sources. The output correction factors were determined scoring the absorbed dose within a detector and to a small water volume in the absence of the detector, both at a depth of 10 cm, for each small field and for the reference beam of 10 × 10 cm{sup 2}. Results: The Monte Carlo calculated output correction factors for the liquid ionization chamber and the diamond detector were within about ±1% of unity even for the smallest field sizes. Corrections were found to be significant for small air ionization chambers due to their cavity dimensions, as expected. The correction factors for silicon diodes varied with the detector type (shielded or unshielded), confirming the findings by other authors; different corrections for the detectors from the two manufacturers were obtained. The differences in the calculated factors for the various detectors were analyzed thoroughly and whenever possible the results were compared to published data, often calculated for different accelerators and using the EGSnrc MC system. The differences were used to estimate a type-B uncertainty for the correction factors. Together with the type-A uncertainty from the Monte Carlo calculations, an estimation of the combined standard uncertainty was made, assigned to the mean correction factors from various estimates. Conclusions: The present work provides a consistent and specific set of data for the output correction factors of a broad set of detectors in a Varian Clinac iX 6 MV accelerator and contributes to improving the understanding of the physics of small photon beams. The correction factors cannot in general be neglected for any detector and, as expected, their magnitude increases with decreasing field size. Due to the reduced number of clinical accelerator types currently available, it is suggested that detector output correction factors be given specifically for linac models and field sizes, rather than for a beam quality specifier that necessarily varies with the accelerator type and field size due to the different electron spot dimensions and photon collimation systems used by each accelerator model.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-358: Monte Carlo Dose Calculation of Small Field Electron Beams

Purpose: Dynamic radiotherapy involving electron beams such as Dynamic Electron Arc Radiotherapy (DEAR) requires accurate dose modelling of small field sizes, similar to the requirement of IMRT field on the small photon field. The current commercial electron Monte Carlo algorithms such as eMC v11 in Eclipse were developed for standard field sizes and do not support the planning of dynamic therapy yet. The purpose of this study is to develop a method to accurately model small field electron beam dosimetry using Monte Carlo simulations. Methods: Comparison between eMC, phantom measurements (diode), and Monte Carlo (MC) simulations (BEAMnrc/DOSYZnrc) were performed for a Varian TrueBeam linac. MC simulations utilized Varian TrueBeam phase space files which had been validated in another study. Static single small field was assessed by comparing dose distributions in water for a 16 MeV beam for circular (2 cm diameter) and rectangular (1×10 cm{sup 2}) cut-out. MC was performed with a resolution of 2.5×2.5×2 mm{sup 2} and statistical uncertainty < 4%. The dose distribution was averaged over adjacent bins to improve precision. Depth dose and orthogonal profiles were evaluated. Results: Small field PDDs differ from those with standard cones. For both circular and rectangular cutouts, the difference in range R8 0-R1 0 is less than 2 mm and in dose within 2%. For the orthogonal profiles, field size and penumbra differences were within 1 mm at depth of maximum dose. The eMC displayed a distinctive “step” in the out-field dose profile in disagreement with both measurement and MC results and needs further investigation. Conclusion: MC was able to characterize the small field dosimetry with good agreement with the measurement data, and thus offers the opportunity for treatment planning of dynamic radiotherapy. Analyses for all other electron energies and cut-out sizes are under way and results will be included in the presentation.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-431: Vertically-Oriented Farmer-Type Chamber for Small-Field Applications

Purpose: To introduce a non-conventional measurement setup using Farmer-type chambers to accommodate several situations of small-field dose measurements without compromising accuracy. The validation of this technique was demonstrated for photon small-field output measurements, and electron small-field percentage depth-dose (PDD) measurements. Methods: Initial chamber alignment was performed using the conventional (horizontally-oriented) chamber setup. A PDD was acquired for a 4×4 cm{sup 2} field size using this arrangement. This PDD was used as a positional reference for the vertically-oriented chamber (VOC) configuration. Next, a PDD was acquired for a 4×4 cm{sup 2} field size with the VOC. The PDD's were superimposed to find the effective shift of the VOC. Using the shifted VOC setup, photon small-field output factors were measured and compared to stereotactic diode output factor measurements. Additionally, electron smallfield PDD's were acquired using the VOC setup and results were compared to electron Monte Carlo (eMC) predictions in the Eclipse treatment planning system (TPS). Results: (1) For photon small-field output factors field-sizes 2×2 cm{sup 2} and larger, the difference between the VOC setup and SFD measurements were less than 0.8%. For field sizes less than 2×2 cm{sup 2} discrepancies ranged from 4.0 to 10.6%. (2) PDD's measured by VOC setup show better than 1.6% agreement as compared to eMC for all electron energies measured down to the 80% depth on the 2×2 cm{sup 2} PDD curve. Disagreement between the VOC setup measurement and eMC calculations for depths down to the 50% depth on the PDD curve is 3.6% or less. Conclusion: Using the VOC setup, it is possible to use a conventional farmer chamber for small field-size measurements down to 2×2 cm{sup 2} field size without sacrificing the accuracy of measurements.

60 APPLIED LIFE SCIENCES↗

SU-C-BRE-01: 3D Conformal Micro Irradiation Results of Four Treatment Sites for Preclinical Small Animal and Clinical Treatment Plans

Purpose: Small animal irradiation can provide preclinical insights necessary for clinical advancement. In order to provide clinically relevant data, these small animal irradiations must be designed such that the treatment methods and results are comparable to clinical protocols, regardless of variations in treatment size and modality. Methods: Small animal treatments for four treatment sites (brain, liver, lung and spine) were investigated, accounting for change in treatment energy and target size. Up to five orthovoltage (300kVp) beams were used in the preclinical treatments, using circular, square, and conformal tungsten apertures, based on the treatment site. Treatments were delivered using the image guided micro irradiator (microIGRT). The plans were delivered to a mouse sized phantom and dose measurements in axial and coronal planes were performed using radiochromic film. The results of the clinical and preclinical protocols were characterized in terms of conformality number, CTV coverage, dose nonuniformity ratio, and organ at risk sparing. Results: Preclinical small animal treatment conformality was within 1–16% of clinical results for all treatment sites. The volume of the CTV receiving 100% of the prescription dose was typically within 10% of clinical values. The dose non-uniformity was consistently higher for preclinical treatments compared to clinical treatments, indicating hot spots in the target. The ratios of the mean dose in the target to the mean dose in an organ at risk were comparable if not better for preclinical versus clinical treatments. Finally, QUANTEC dose constraints were applied and the recommended morbidity limits were satisfied in each small animal treatment site. Conclusion: We have shown that for four treatment sites, preclinical 3D conformal small animal treatments can be clinically comparable if clinical protocols are followed. Using clinical protocols as the standard, preclinical irradiation methods can be altered and iteratively improved to achieve a clinically relevant irradiation model.

60 APPLIED LIFE SCIENCES↗

SU-E-P-34: Dose Perturbation Caused by Sun Nuclear QED Diode When Used for Very Small Electron Fields

Purpose: Diodes are utilized by radiotherapy departments to help verify that treatment fields are being delivered correctly to the patient. Some treatment fields utilize electron beams along with a cerrobend cutout to shape the beam to the area to be treated. Cerrobend cutouts can sometimes be very small < 2×2-cm2. Some published work has addressed diode perturbation for cutout sizes down to 1.5-cm, this work addresses the diode perturbation of the Sun Nuclear QEDTM diode for cutouts as small as 0.5-cm in diameter. Methods: Measurements were taken with an A16 Exradin micro-chamber in Solid Water to 100-cm SSD. Dmax was determined for each cutout using various amounts of Solid Water in 1–2 mm increments to account for the dmax shifting in small fields. The diode was placed on top of the solid water to 100-cm SSD in the center of the cutout. Measurements were taken with no diode for comparison. The cutouts ranged in diameter from 0.5-cm to 5.0-cm and included the open 6×6 insert. Measurements were made for energies 6, 9, 12, 15,&18 MeV. Results: For 6 MeV, the percent dose reduction from the diode in the cutout field compared to the field without the diode ranged from 35% to 25% as a function of cutout size. For higher energies, this percentage decreased and generally was 25% to 15%. It was observed that dmax shifts significantly upstream for very small cutouts (<2-cm diameter) to less than 1 cm for all energies. Conclusion: The presence of diodes in small electron fields is enough to cause significant dose perturbation to the target volume. It is recommended that diodes for very small electron fields be used sparingly or possibly with a dose correction per treatment fraction(s), if the total projected delivered dose is going to be significantly different from that prescribed by the physician.

60 APPLIED LIFE SCIENCES↗

SU-E-T-124: Anthropomorphic Phantoms for Confirmation of Linear Accelerator Based Small Animal Irradiation

Purpose: To document the support of radiobiological small animal research by a modern radiation oncology facility. This study confirms that a standard, human use linear accelerator can cover the range of experiments called for by researchers performing animal irradiation. A number of representative, anthropomorphic murine phantoms were made. The phantoms confirmed the small field photon and electron beams dosimetry validated the use of the linear accelerator for rodents. Methods: Laser scanning a model, CAD design and 3D printing produced the phantoms. The phantoms were weighed and CT scanned to judge their compatibility to real animals. Phantoms were produced to specifically mimic lung, gut, brain, and othotopic lesion irradiations. Each phantom was irradiated with the same protocol as prescribed to the live animals. Delivered dose was measured with small field ion chambers, MOS/FETs or TLDs. Results: The density of the phantom material compared to density range across the real mice showed that the printed material would yield sufficiently accurate measurements when irradiated. The whole body, lung and gut irradiations were measured within 2% of prescribed doses with A1SL ion chamber. MOSFET measurements of electron irradiations for the orthotopic lesions allowed refinement of the measured small field output factor to better than 2% and validated the immunology experiment of irradiating one lesion and sparing another. Conclusion: Linacs are still useful tools in small animal bio-radiation research. This work demonstrated a strong role for the clinical accelerator in small animal research, facilitating standard whole body dosing as well as conformal treatments down to 1cm field. The accuracy of measured dose, was always within 5%. The electron irradiations of the phantom brain and flank tumors needed adjustment; the anthropomorphic phantoms allowed refinement of the initial output factor measurements for these fields which were made in a large block of solid water.

60 APPLIED LIFE SCIENCES↗