Search NASA⌕ Search

SEARCH · Search NASA

Results for “Software Installation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Simulations and Data analysis for the 35 ton Liquid Argon detector as a prototype for the DUNE experiment

The Deep Underground Neutrino Experiment (DUNE) is a next-generation neutrino experiment which will be built at the Sanford Underground Research Facility (SURF), and will receive a wide-band neutrino beam from Fermilab, 1300~km away. At this baseline DUNE will be able to study many of the properties of neutrino mixing, including the neutrino mass hierarchy and the value of the CP-violating complex phase ($\delta_{CP}$). DUNE will utilise Liquid Argon (LAr) Time Projection Chamber (TPC) (LArTPC) technology, and the Far Detector (FD) will consist of four modules, each containing 17.1~kt of LAr with a fiducial mass of around 10~kt. Each of these FD modules represents around an order of magnitude increase in size, when compared to existing LArTPC experiments. \\ The 35 ton detector is the first DUNE prototype for the single (LAr) phase design of the FD. There were two running periods, one from November 2013 to February 2014, and a second from November 2015 to March 2016. During t he second running period, a system of TPCs was installed, and cosmic-ray data were collected. A method of particle identification was developed using simulations, though this was not applied to the data due to the higher than expected noise level. A new method of determining the interaction time of a track, using the effects of longitudinal diffusion, was developed using the cosmic-ray data. A camera system was also installed in the detector for monitoring purposes, and to look for high voltage breakdowns. \\ Simulations concerning the muon-induced background rate to nucleon decay are performed, following the incorporation of the MUon Simulations UNderground (MUSUN) generator into the DUNE software framework. A series of cuts which are based on Monte Carlo truth information is developed, designed to reject simulated background events, whilst preserving simulated signal events in the $n \rightarrow K^{+} + e^{-}$ decay channel. No background events are seen to survive the app lication of these cuts in a sample of 2~$\times$~10$^9$ muon! s, representing 401.6~years of detector live time. This corresponds to an annual background rate of <~0.44~events$\cdot$Mt$^{-1}\cdot$year$^{-1}$ at 90\% confidence, using a fiducial mass of 13.8~kt.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Research and Development Toward Massive Liquid Argon Time Projection Chambers for Neutrino Detection

Liquid argon (LAr) time projection chambers (TPC) have rapidly increased in importance as particle detectors throughout the past four decades. While much research has been completed, there are still many areas which require further development to build and operate the next generation LAr TPC experiment, such as the Deep Underground Neutrino Experiment (DUNE). These include high voltage breakdown, argon purification and purity monitoring, and vacuum ultraviolet (VUV) scintillation light measurement. Visual monitoring of high voltage breakdown is helpful in allowing assessment of the performance of high voltage component design. Thus, a system of cryogenic cameras, the first of its kind, was developed for use in a large LAr cryostat, without the need for additional electronics heating. The system functioned without problem for 50 days at cryogenic temperature, with some degradation of image quality, and provided a useful monitor for the DUNE 35-ton cryogenics systems. The system did not observe any high voltage breakdowns during the run. Further development of the concept is ongoing for future installation in other experiments. The monitoring of LAr purity using TPC data is a fundamental study for LAr TPC experiments. However, the study has not been performed for a large LAr TPC in the presence of high electronic noise. Custom software was developed and validated for the accurate reconstruction of signals in noisy TPC data. The results of the reconstruction were used to successfully measure the LAr electron lifetime with an uncertainty comparable to alternate methods of measurement. The electron lifetime of the 35-ton Phase II run is determined to be 4.12 ± 0.17 (stat.) ±0.40 (syst.) ms. For general purpose research and development of high purity LAr as a particle detection medium, a dedicated test stand was designed, constructed, and commissioned. The system is used to test the gaseous photomultiplier (GPM) performance at cryogenic temperatures. The GPM functions with photoelectron multiplication at 77 K, at a reduced gain. Further study is required to show the detector’s direct sensitivity to LAr VUV scintillation light.

Thiesse, Matthew↗

Thermostatic Radiator Valve Evaluation and Demonstration

A large stock of multifamily buildings in the Northeast and Midwest uses hot water or steam for space heating. Typically, residents do not pay for heat directly (i.e., heating fuel serves a central plant and use is not submetered). Losses from these systems are typically high, and a significant number of apartments are overheated much of the time. This is often evidenced by open windows on winter days. Controls and distribution are often faulty, and improving them can be more cost effective than replacing boilers. Thermostatic radiator valves (TRVs), which have been in use for many decades, are one potential strategy to combat this problem. They are commonly used in Europe and in other markets such as commercial buildings, but have not been widely accepted by the residential retrofit market in the northeastern United States. Anecdotal evidence suggests that heating systems engineers and contractors have a variety of opinions about their effectiveness, illustrating a lack of consensus on this potentially important energy efficiency measure. A review of the limited available literature revealed that, in one study, heating fuel savings as high as 15% was achieved through TRV retrofits. In this project, the U.S. Department of Energy Building America team, Advanced Residential Integrated Energy Solutions, sought to better understand the current usage of TRVs by key market players in steam and hot water heating and to conduct limited experiments on the effectiveness of new and old TRVs as a means of controlling space temperatures and reducing heating fuel consumption. The project included a survey of industry professionals, a field experiment comparing old and new TRVs, and cost-benefit modeling analysis using BEopt (Building Energy Optimization software). Radiator and apartment space temperature data were collected and analyzed for two similar apartment units in a building that underwent a one-pipe steam TRV retrofit. Space temperature comparisons were made across the pre- and post-TRV installation heating periods and between rooms equipped with old or new TRVs in an attempt to show the comparative effectiveness of each vintage of TRV. Analyses of the heating fuel utility bills before and after the building-wide TRV installation were conducted to quantify potential savings. The results of the field experiment and utility bill analysis did not show energy savings at either the unit or the building-wide level. The results provided inconclusive answers to the original study questions but provided valuable insight into common steam system imbalance and resident behavior issues that are critical to address in conjunction with TRV retrofits. Specific issues identified included steam distribution imbalance, possible TRV sensor location issues, a persistent window-opening habit, and a failure to optimize the boiler control set points as part of the TRV retrofit. The lack of heating fuel savings underscored the need to include whole steam system commissioning alongside or as a prerequisite to TRVs. Failed air vents and uneven steam main venting are critical to address either in conjunction with or before a TRV installation. Monitoring existing space temperatures before a retrofit strategy is chosen would allow the consultant and building owner to better assess the potential benefits of a whole-building TRV retrofit, selective installation of TRVs in some units, or simply balancing the steam distribution venting. Further gaps in the understanding of underlying processes that allow TRVs to function effectively were also identified and are presented as opportunities for future research.

Array↗

Impedance Measurement Box

Energy storage devices, primarily batteries, are now more important to consumers, industries and the military. With increasing technical complexity and higher user expectations, there is also a demand for highly accurate state-of-health battery assessment techniques. IMB incorporates patented, proprietary, and tested capabilities using control software and hardware that can be part of an embedded monitoring system. IMB directly measures the wideband impedance spectrum in seconds during battery operation with no significant impact on service life. It also can be applied to batteries prior to installation, confirming health before entering active service, as well as during regular maintenance. For more information about this project, visit http://www.inl.gov/rd100/2011/impedance-measurement-box/

25 ENERGY STORAGE↗

Verification of a Modeling Toolkit for the Design of Building Electrical Distribution Systems

DC electrical distribution systems offer many potential advantages over their AC counterparts. They can facilitate easier integration with distributed energy resources, improve system energy efficiency by eliminating AC/DC converters at end-use devices (e.g., laptop chargers), and reduce installation material, time, and cost. However, DC electrical distribution systems present additional design considerations, largely resulting from potentially greater magnitude and variation in cable losses. Modeling and simulation are rarely used to design such systems. However, the greater dependency of DC system energy efficiency on design choices such as distribution voltages, architecture, and integration of PV and BESS suggests that modeling and simulation may be required. Such system performance analysis is currently not a standard practice, in part due to limited availability and validation of capable software tools. This paper characterizes the accuracy of a Modelica-based Building Electrical Efficiency Analysis Model (BEEAM) toolkit, as a precursor for validating its use to perform system performance analysis and inform design decisions. The study builds upon previous verification research by characterizing complete systems comprised of commercially available equipment, and providing a more detailed analysis of simulation results. Five lighting systems with varying electrical distribution architectures were designed using market-available equipment, installed in a laboratory environment, modeled using BEEAM, and simulated using three Modelica integrated development environments (IDEs). Simulated and measured results were compared to characterize toolkit accuracy. Initial results revealed that simulated performance was mostly within ±5% of measured system-level and device-level performance. While simulation results were not found to be dependent on the IDE, some Modelica compiler interoperability issues were identified. Although the BEEAM toolkit showed promise for the targeted use case, further work is needed to determine whether the demonstrated 5% accuracy is sufficient for making real-world design decisions, and for BEEAM to advance from an interesting research tool to one that can impact real-world building projects.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SU-E-T-211: Comparison of Seven New TrueBeam Linacs with Enhanced Beam Data Conformance Using a Beam Comparison Software Tool

Purpose: To develop an independent software tool to assist in commissioning linacs with enhanced beam conformance, as well as perform ongoing QA for dosimetrically equivalent linacs. Methods: Linac manufacturers offer enhanced beam conformance as an option to allow for clinics to complete commissioning efficiently, as well as implement dosimetrically equivalent linacs. The specification for enhanced conformance includes PDD as well as profiles within 80% FWHM. Recently, we commissioned seven Varian TrueBeam linacs with enhanced beam conformance. We developed a software tool in Visual Basic to allow us to load the reference beam data and compare our beam data during commissioning to evaluate enhanced beam conformance. This tool also allowed us to upload our beam data used for commissioning our dosimetrically equivalent beam models to compare and tweak each of our linac beams to match our modelled data in Varian’s Eclipse TPS. This tool will also be used during annual QA of the linacs to compare our beam data to our baseline data, as required by TG-142. Results: Our software tool was used to check beam conformance for seven TrueBeam linacs that we commissioned in the past six months. Using our tool we found that the factory conformed linacs showed up to 3.82% difference in their beam profile data upon installation. Using our beam comparison tool, we were able to adjust the energy and profiles of our beams to accomplish a better than 1.00% point by point data conformance. Conclusion: The availability of quantitative comparison tools is essential to accept and commission linacs with enhanced beam conformance, as well as to beam match multiple linacs. We further intend to use the same tool to ensure our beam data conforms to the commissioning beam data during our annual QA in keeping with the requirements of TG-142.

43 PARTICLE ACCELERATORS↗

Demonstration of a modeling toolkit for the design of building electrical distribution systems

The deployment of building equipment (e.g., lighting, security) and miscellaneous electrical loads that fundamentally require DC power for operation is increasing. Powering these DC loads has traditionally required an AC/DC converter, but the installation of photovoltaic (PV) and battery energy storage systems that primarily produce DC power eliminates the need for AC/DC converters at each end-device. However, analyzing system energy efficiency and cost for different electrical distribution architectures can be challenging as software tools that support this are not readily available. This paper presents preliminary results from a laboratory verification of the Building Electrical Efficiency Analysis Model (BEEAM) toolkit that was developed to address this gap. Three different eight-luminaire lighting systems comprised of market-available products were designed and modeled: one that used traditional AC distribution, a second that used a hybrid AC -to- centralized DC electrical distribution architecture, and a third that used a hybrid AC -to- distributed DC architecture. Notably, AC/DC conversions are required in all three systems. BEEAM models for LED drivers as well as Power-over-Ethernet (PoE) switches were created using laboratory characterization data. The lighting systems were simulated in Modelica, and the results were compared with each other and physics-based expectations. Simulation results show that PoE system energy efficiency is highly dependent on both device specification (e.g., LED driver and PoE switch efficiency) and system architecture (e.g., PoE switch loading) choices, as expected. For the products and system architectures selected for this study, the two DC systems were found to be less efficient than the AC system over the course of typical operation. In future work, simulation results will be compared with laboratory measurements to validate the usefulness of this software for design, and lighting systems with integrated PV and battery energy storage will be simulated to quantify the energy performance improvements that result from the elimination of some AC/DC converters.

Waghale, Anay S.↗

HyRAM+ (Hydrogen Plus Other Alternative Fuels Risk Assessment Models) v.4.0

HyRAM+ is a software toolkit for conducting quantitative risk assessment (QRA) and consequence modeling for hydrogen and other alternative fuels infrastructure and transportation systems. HyRAM+ contains validated, simplified release behavior models, a standardized QRA approach, and engineering models and generic data relevant to hydrogen installations. HyRAM (hydrogen-only) versions 1.0 to 3.1 were developed by Sandia for the U.S. Department of Energy (DOE) Hydrogen and Fuel Cell Technologies Office (HFTO). The U.S. DOE Vehicle Technologies Office (VTO) and U.S. Department of Transportation (DOT) Pipeline and Hazardous Material Safety Administration (PHMSA) contributed to the development of HyRAM+ version 4.0 regarding the addition of methane (natural gas) and propane models. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. SAND2021-10862 O

Groth, Katrina↗

HyRAM+ (Hydrogen Plus Other Alternative Fuels Risk Assessment Models) v.4.1.1

HyRAM+ is a software toolkit for conducting quantitative risk assessment (QRA) and consequence modeling for hydrogen and other alternative fuels infrastructure and transportation systems. HyRAM+ contains validated, simplified release behavior models, a standardized QRA approach, and engineering models and generic data relevant to hydrogen installations. HyRAM (hydrogen-only) versions 1.0 to 3.1 were developed by Sandia for the U.S. Department of Energy (DOE) Hydrogen and Fuel Cell Technologies Office (HFTO). The U.S. DOE Vehicle Technologies Office (VTO) and U.S. Department of Transportation (DOT) Pipeline and Hazardous Material Safety Administration (PHMSA) contributed to the development of HyRAM+ version 4.0 regarding the addition of methane (natural gas) and propane models. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. SAND2021-10862 O

Groth, Katrina↗

HyRAM+ (Hydrogen Plus Other Alternative Fuels Risk Assessment Models) v.5.1.1

HyRAM+ is a software toolkit for conducting quantitative risk assessment (QRA) and consequence modeling for hydrogen and other alternative fuels infrastructure and transportation systems. HyRAM+ contains validated, simplified release behavior models, a standardized QRA approach, and engineering models and generic data relevant to hydrogen installations. HyRAM (hydrogen-only) versions 1.0 to 3.1 were developed by Sandia for the U.S. Department of Energy (DOE) Hydrogen and Fuel Cell Technologies Office (HFTO). The U.S. DOE Vehicle Technologies Office (VTO) and U.S. Department of Transportation (DOT) Pipeline and Hazardous Material Safety Administration (PHMSA) contributed to the development of HyRAM+ version 4.0 regarding the addition of methane (natural gas) and propane models. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. SAND2021-10862 O

Groth, Katrina↗

An advanced materials irradiation facility for materials and fuels irradiations at the high flux isotope reactor

The High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) is a pressurized, light-water-cooled and -moderated, beryllium-reflected, 85 MW research reactor fueled by Highly enriched {sup 235}U. The Materials Irradiation Facility (MIF) at HFIR) is one of the two experimental platforms in the US that can host fully instrumented and monitored experiments in a high-neutron-flux environment. The unique advantage of instrumented capsules is that the researcher can monitor and acquire in situ data and change capsule operating conditions in real time during the irradiation. Recently ORNL funded a Laboratory-Directed Research and Development (LDRD) project to strategically enhance the capabilities of MIF and provide researchers with a more flexible experimental platform. MIF comprises 4 systems: a gas supply system, a supervisory control system, an effluent system, and a standard gas routing system. The first 3 systems have common functionality for all types of experiments. The gas routing system provides the correct gases and gas mixtures for individual experiments and is unique to each experiment. MIF improvements include an updated and more sophisticated experiment monitoring system, a modular design allowing easier addition of simultaneous experiments, and features that allow rapid incorporation of additional instrumentation. The new design is both modular and re-configurable. It calls for a standard gas routing system module that can be configured with software to allow for easy expansion to multiple experiments. The ability to monitor the effluent activity during fissile material irradiation is a much needed enhancement for detecting fuel failures or determining fission product release. A gamma-ray spectrometry will be installed in a bypass gas line off the effluent main stream. The gas will flow through the detector for continuous detection of the particles of interest.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Advanced Modeling Fast Simulation Algorithms for Alternate Arm Converters

There is increasing interest in alternate arm converter (AAC) due to the fault-tolerant characteristics it could offer in high-voltage direct current (HVdc) systems. The simulation of AACs is important to assist with the design of hardware, control systems, and planning of power system expansions. However, simulation of AAC-HVdc using existing software takes a long time due to the presence of a large number of states and non-linear devices. An ultra-fast single-or multi-CPU simulation algorithm to simulate the AAC-HVdc system based on state-space models and using hybrid discretization algorithm with a relaxation technique that reduces the imposed computational burden is presented in this paper. The developed algorithm is validated with respect to reference PSCAD/EMTDC model.

Debnath, Suman↗

CCSI Toolset 3.18 Release

CCSI Toolset 3.18 Release Highlights FOQUS was updated to allow installation for users using MacOS on Apple silicon. FOQUS Cloud support was added for user plugins. The Optimality-Based Design of Experiments tutorials were updated to reflect the latest changes in the user interface flow. The plot discrete sliders were fixed for CDF and 3D plots within Uncertainty Quantification, which were not working due to a matplotlib depreciation. The installation was updated to set the default location for the PSUADE executable if found in the environment. Updates were made to allow compatibility with NumPy 1.25. Additional documentation changes were made to fix typographical errors and fix a broken link to optional software.

AS↗

Design of a high power 8 MeV electron beam injector for the LERF

We present the beamline design for a high power 8 MeV electron injector to be installed at the Low Energy Recirculator Facility (LERF). The injector is designed to provide beam power of up to 80 kW for testing positron source target candidates. We discuss the results of beam dynamics simulations conducted using the General Particle Tracer (GPT) software, where electromagnetic beamline elements were optimized using multi-objective genetic algorithm tools. Additionally, we present preliminary studies on secondary particle generation from both rotating solid and free surface liquid metal jet targets described elsewhere in this workshop.

Lizarraga-Rubio, Victor [Thomas Jefferson National↗

Design of a high power 8 MeV electron beam injector for the LERF

Here, we present the beamline design for a high power 8 MeV electron injector to be installed at the Low Energy Recirculator Facility (LERF). The injector is designed to provide beam power of up to 80 kW for testing positron source target candidates. We discuss the results of beam dynamics simulations conducted using the General Particle Tracer (GPT) software, where electromagnetic beamline elements were optimized using multi-objective genetic algorithm tools. Additionally, we present preliminary studies on secondary particle generation from both rotating solid and free surface liquid metal jet targets described elsewhere in this workshop.

Lizarraga-Rubio, Victor Manuel [Thomas Jefferson N↗

Suggestions for better election security.

Summary of Common Security Mistakes: (1) Electronic voting machines that fundamentally lack security thought and features, including an ability to detect tampering or intrusion, or to be reliably locked or sealed; (2) Failure to disassemble, inspect, and thoroughly inspect (not just test) a sufficient number of voting machines before and after elections in order to detect hardware or software tampering; (3) Assuming that tamper - indicating seals will either be blatantly ripped/smashed open, or else there is no tampering. In reality, even amateurs can spoof most seals leaving (at most) subtle evidence; (4) Inadequate seal use protocols and training of seal installers and inspectors. Failure to show examples of blatantly and subtly attacked seals to seal inspectors; (5) Over confidence in use of a voter verified paper record (VVPR), a VVPR is an excellent security countermeasure, but it is not a silver bullet, especially for an election organization with poor overall security; (6) Little or no insider thr at mitigation; and (7) A poor security culture, including denial and no a priori procedures for dealing with security questions or concerns.

99 GENERAL AND MISCELLANEOUS↗

Sensitivity analysis on optical performance of a novel linear Fresnel concentrating solar power collector

A novel, low-cost linear Fresnel collector for concentrating solar power applications is being developed by Hyperlight Energy (Hyperlight) and the National Renewable Energy Laboratory (NREL). Hyperlight is currently deploying their linear Fresnel collector technology in a half-acre pilot loop near Brawley, California. The optical performance of a concentrating solar power collector represents the largest loss in the efficiency of the overall system. The ability to accurately model the complex optical interactions of a collector becomes essential in successfully implementing a new collector technology. Here, this study presents a detailed sensitivity analysis of the optical performance of Hyperlight linear Fresnel technology, characterizing the effects of potential optomechanical error sources on collector performance. Optical models are implemented in SolTrace, a Monte-Carlo ray-tracing software developed at NREL. First, SolTrace is used to analyze collector sensitivity to individual optomechanical error perturbations in both the primary reflectors and the receiver assembly. Then, a high-fidelity optomechanical error model is adopted to capture the realistic performance of the installed Hyperlight linear Fresnel collector. Finally, the sensitivity analysis can provide insightful guidance to inform the tightening and relaxation of tolerances during manufacturing and implementation of a new collector technology.

14 SOLAR ENERGY↗

TIA: A forward model and analyzer for Talbot interferometry experiments of dense plasmas

Interferometry is one of the most sensitive and successful diagnostic methods for plasmas. However, owing to the design of most common interferometric systems, the wavelengths of operation and, therefore, the range of densities and temperatures that can be probed are severely limited. Talbot–Lau interferometry offers the possibility of extending interferometry measurements to x-ray wavelengths by means of the Talbot effect. While there have been several proof-of-concept experiments showing the efficacy of this method, it is only recently that experiments to probe High Energy Density (HED) plasmas using Talbot–Lau interferometry are starting to take place. To improve these experimental designs, we present here the Talbot-Interferometry Analyzer (TIA) tool, a forward model for generating and postprocessing synthetic x-ray interferometry images from a Talbot–Lau interferometer. Although TIA can work with any two-dimensional hydrodynamic code to study plasma conditions as close to reality as possible, this software has been designed to work by default with output files from the hydrodynamic code FLASH, making the tool user-friendly and accessible to the general plasma physics community. Here, the model has been built into a standalone app, which can be installed by anyone with access to the MATLAB runtime installer and is available upon request to the authors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗