Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Comparing Thermal Neutron Scintillators for Use With SiPM-Readout Detectors

Scintillator-based thermal neutron detectors for scientific scattering facilities offer an effective combination of large-area coverage and good spatial resolution. At Oak Ridge National Laboratory, silicon photomultiplier (SiPM)-readout Anger cameras using 6 Li glass scintillators have been developed, but the spatial resolution of these detectors is limited by the relatively low light yield of the glass. Recently, several brighter scintillator compositions with sufficient 6 Li concentration have emerged as promising candidates for higher-resolution imaging. Here, in this work, we evaluate five scintillator materials: GS20, LiF/ZnS:Ag, LiF/ZnO:Zn, LiI:Eu, and Cs 2 LiYCl 6 :Ce, each mounted on a SiPM Anger camera. For each scintillator, the neutron detection efficiency, spatial resolution, and count rate capabilities were measured and compared. Each of the new compositions achieved a spatial resolution better than 0.5 mm, compared to 0.66 mm for GS20, with LiI:Eu reaching the best value of 0.32 mm. Although these compositions improve the spatial resolution of the Anger camera, their longer pulse decay times limit their use in high count rate applications, and the camera’s hardware must be optimized for the different properties of the new scintillators.

Neutron detectors↗

Methods of photoelectrode characterization with high spatial and temporal resolution

Here, materials and photoelectrode architectures that are highly efficient, extremely stable, and made from low cost materials are required for commercially viable photoelectrochemical (PEC) water-splitting technology. A key challenge is the heterogeneous nature of real-world materials, which often possess spatial variation in their crystal structure, morphology, and/or composition at the nano-, micro-, or macro-scale. Different structures and compositions can have vastly different properties and can therefore strongly influence the overall performance of the photoelectrode through complex structure–property relationships. A complete understanding of photoelectrode materials would also involve elucidation of processes such as carrier collection and electrochemical charge transfer that occur at very fast time scales. We present herein an overview of a broad suite of experimental and computational tools that can be used to define the structure–property relationships of photoelectrode materials at small dimensions and on fast time scales. A major focus is on in situ scanning-probe measurement (SPM) techniques that possess the ability to measure differences in optical, electronic, catalytic, and physical properties with nano- or micro-scale spatial resolution. In situ ultrafast spectroscopic techniques, used to probe carrier dynamics involved with processes such as carrier generation, recombination, and interfacial charge transport, are also discussed. Complementing all of these experimental techniques are computational atomistic modeling tools, which can be invaluable for interpreting experimental results, aiding in materials discovery, and interrogating PEC processes at length and time scales not currently accessible by experiment. In addition to reviewing the basic capabilities of these experimental and computational techniques, we highlight key opportunities and limitations of applying these tools for the development of PEC materials.

08 HYDROGEN↗

Five kHz thermometry in turbulent spray flames using chirped-probe pulse femtosecond CARS, part I: Processing and interference analysis

We have applied chirped-probe-pulse (CPP) femtosecond (fs) coherent anti-Stokes Raman scattering for 5 kHz temperature measurements in turbulent spray flames. The CPP fs CARS technique has previously been used to perform spectroscopic temperature measurements in highly turbulent laboratory burners with excellent accuracy, precision, temporal resolution, and spatial resolution. In this paper, ultrafast CARS measurements in spray flames are presented as part of a larger effort to provide spatially and temporally resolved temperature fields in harsh spray environments. The Sydney Needle Spray Burner (SYNSBURN TM ) was used to stabilize turbulent spray flames of acetone and ethanol. The burner features a retractable fuel injector so that the droplet density at the nozzle exit could be systematically varied. Results from selected regions of the turbulent spray flames are discussed in detail to highlight the challenges of CPP fs CARS temperature measurements. Sources of spectral distortion due to interaction with droplets are discussed along with an uncertainty analysis. The passage of fuel through the probe volume caused varying levels of signal degradation and resulted in complete signal loss on approximately 10% of the laser shots for dense spray conditions. The interferences are attributed to two separate phenomena and are categorized based on the probable phase of the fuel – liquid or gas. Interference caused by liquid fuel was unavoidable in certain regions at certain operating conditions, but easily identified and removed. Interference from vapor fuel was more problematic as the nitrogen signal was only moderately corrupted in the high-frequency portion of the spectrum, and the temperature was generally biased to higher values. Rejecting individual signal spectra, based on a fitting error threshold, was shown to be effective in excluding shots with significant interference from fuel droplets, but shots with only minor interference require a more-advanced rejection criterion. Analysis of the temperature fields for a few selected conditions is presented showing trends with the atomization quality of the liquid fuel. Fourier analysis revealed hydrodynamic instabilities in the shear layer and relatively weak thermoacoustic instabilities in the reaction zone.

42 ENGINEERING↗

Scalable Detector Design for a High-Resolution Fast-Neutron Radiography Panel

Development of a scalable flat-panel neutron radiography device is needed to meet the nondestructive testing needs of a growing industrial market. Flood field images from a Cs-137 gamma source and a Cf-252 fission neutron source were generated using a detector composed of a 3-mm-thick sheet of EJ-200, and 3-mm-thick sheet of acrylic light spreader, an 8 $\times$ 8 array of SensL MICROFJ-60035-TSV SiPMs, and an IDEAS ROSSPAD readout module. The readout module can be tiled together with similar systems to create a panel of any size, and is only limited by the number of available Ethernet ports in a switching system. A collimated gamma line image demonstrated a 90% spatial resolution of approximately 0.47 line pairs per centimeter and a 10% spatial resolution of approximately 2.32 line pairs per centimeter. A neutron edge image demonstrated a 90% spatial resolution of approximately 0.70 line pairs per centimeter and a 10% spatial resolution of approximately 3.35 line pairs per centimeter. Both of these images show the ability to generate radiographs with sub-SiPM spatial resolution. Using these readout modules, a large-scale radiographic panel can be developed by tiling ROSSPAD modules together.

36 MATERIALS SCIENCE↗

An important criterion for reliable multi-monochromatic x-ray imager diagnostics and its impact on the reconstructed images

Temperature and density asymmetry diagnosis is critical to advance inertial confinement fusion (ICF) science. A multimonochromatic x-ray imager, MMI, records the spectral signature from an ICF implosion core with time resolution, 2D spatial resolution and spectral resolution. While narrow-band images and 2D space-resolved spectra from the MMI data constrain the temperature and the density spatial structure of the core, the accuracy of the images and the spectra highly depends on the quality of the MMI data and the processing tools. Here, we synthetically investigate the criterion for reliable MMI diagnostics and its effects on the accuracy of the reconstructed images. The pinhole array tilt determines the object spatial sampling efficiency and the minimum reconstruction width, $\textit{w}$. When the spectral width associated with $\textit{w}$ is significantly narrower than the spectral linewidth, the line images reconstructed from the MMI data become reliable. The MMI setup has to be optimized for every application to meet this criterion for reliable ICF diagnostics.

47 OTHER INSTRUMENTATION↗

Direct analysis of samples by mass spectrometry: From elements to bio-molecules using laser ablation inductively couple plasma mass spectrometry and laser desorption/ionization mass spectrometry

Mass spectrometric methods that are able to analyze solid samples or biological materials with little or no sample preparation are invaluable to science as well as society. Fundamental research that has discovered experimental and instrumental parameters that inhibit fractionation effects that occur during the quantification of elemental species in solid samples by laser ablation inductively coupled plasma mass spectrometry is described. Research that determines the effectiveness of novel laser desorption/ionization mass spectrometric methods for the molecular analysis of biological tissues at atmospheric pressure and at high spatial resolution is also described. A spatial resolution is achieved that is able to analyze samples at the single cell level.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of thin-gap GEM- μ RWELL hybrid detectors

Micro Pattern Gaseous Detectors (MPGDs) are used for tracking in High Energy Physics and Nuclear Physics because of their large area, excellent spatial resolution capabilities and low cost. However, for high energy charged particles impacting at a large angle with respect to the axis perpendicular to detector plane, the spatial resolution degrades significantly because of the long trail of ionization charges produced in clusters all along the track in the drift region of the detector. The long ionization charge trail results in registering hits from large number of strips in the readout plane which makes it challenging to precisely reconstruct the particle’s position using simple center of gravity algorithm. As a result, the larger the drift gap, the more severe the deterioration of spatial resolution for inclined tracks. For the same reason, the position resolution is also severely degraded in a large magnetic field, where the Lorentz E x B effect causes the ionization charges to follow a curved and longer path in the detector gas volume. In this paper, we report on the development of thin-gap MPGDs as a way to maintain excellent spatial resolution capabilities of MPGD detectors over a wide angular range of incoming particles. In a thin-gap MPGD, the thickness of the gas volume in the drift region is reduced from typically 3 mm to 1 mm or less. We present preliminary test beam results demonstrating the improvement in spatial resolution from 400 m with a standard 3 mm gap μ RWELL prototype to ~140 μ m with a double amplification GEM- μ RWELL thin-gap hybrid detector. Here, we also discuss the impact of a thin-gap drift volume on other aspects of the performance of MPGD technologies such as the efficiency and detector stability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Self-Absorption Corrections for Plutonium Measurements With the Tomographic Gamma Scanner - 17325

The Tomographic Gamma Scanner (TGS) is a Non-Destructive Assay (NDA) instrument that combines high-resolution gamma spectroscopy with low spatial resolution three-dimensional image reconstruction in order to reduce bias and improve precision for measurements of drummed waste. The TGS technique is especially suited to measure containers with non-uniform source distributions and low-to me-dium-density heterogeneous matrices, compared with traditional NDA methods. Canberra recently built, installed, and commissioned a TGS system, intended primarily for the measurement of plutonium (Pu) bearing waste, at a European nu-clear fuel reprocessing facility. Pu assays using the TGS technique present technical challenges distinct from those typically encountered in traditional LLW applications. Among these is the need to apply corrections for self-absorption effects that occur on scales smaller than the TGS spatial resolution, and can compromise the assay result if not included in the TGS imaging methodology. We present a brief review of the Self Absorption Correction (SAC) technique, and discuss the complications involved with its application to the TGS methodology with examples from our recent experience. This work continues a Canberra history of further developing and refining a technique to solve emerging problems, having commercialized the original methodology by partnering with the research institution that pioneered it. The TGS and the SAC methodologies were originally developed by Los Alamos National Laboratory (LANL) and John Fleissner respectively, and this work illustrates how Canberra has implemented an advancement of these techniques in a new TGS system. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Recent Advancements in Tomographic Gamma Scanning for Non- Destructive Assay - 17321

Canberra Industries has recently designed and built a Tomographic Gamma Scanning (TGS) system for the deployment in a nuclear facility. The TGS technique combines high-resolution gamma spectroscopy with low spatial resolution 3- dimensional image reconstruction to provide increased accuracy over traditional approaches for the assay of non-uniform source distributions in low-to medium-density containers. The TGS system has been optimized to measure 120 liter drums and has the capability to measure containers of various sizes. Canberra has incorporated numerous enhancements and improvements to the latest system in both its hardware and software components. The signal processing chain and data analysis software have been configured to use either an electronic pulser or digital signal processing (DSP) electronics for dead time corrections. In the case of using the DSP electronics, the need to calibrate and maintain a pulser can be eliminated without sacrificing any performance. For the 120 liter container, the TGS system has been calibrated and validated with three different spatial resolutions, using two collimator aperture sizes, measuring 2.54 and 1.27 cm in width. The system has also been supplied and calibrated with a wide, rectangular collimator (25.4 cm W x 10.2 cm H) for scanning containers solely in the vertical axis. The TGS system also has an automated attenuator assembly, which has the capability to use a combination of attenuators to reduce the count rate for high activity samples. An extensive measurement campaign was performed in addition to the calibration verification to evaluate the accuracy of the system using rod sources, point sources, and a variety of matrices and source distributions. Improvements to the evaluation of the total measurement uncertainty based upon these studies have been incorporated into the analysis software package. Finally, the performance of this new TGS system will be demonstrated in the context of Canberra's previous TGS systems, including several 208 liter-based systems and a smaller, 20 liter container TGS system. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ALMA Discovery of Solar Umbral Brightness Enhancement at λ = 3 mm

We report the discovery of a brightness enhancement in the center of a large sunspot umbra at a wavelength of 3 mm using the Atacama Large Millimeter/sub-millimeter Array (ALMA). Sunspots are among the most prominent features on the solar surface, but many of their aspects are surprisingly poorly understood. We analyzed a λ = 3 mm (100 GHz) mosaic image obtained by ALMA that includes a large sunspot within the active region AR12470, on 2015 December 16. The 3 mm map has a 300″ × 300″ field of view and 4.″9 × 2.″2 spatial resolution, which is the highest spatial resolution map of an entire sunspot in this frequency range. We find a gradient of 3 mm brightness from a high value in the outer penumbra to a low value in the inner penumbra/outer umbra. Within the inner umbra, there is a marked increase in 3 mm brightness temperature, which we call an umbral brightness enhancement. This enhanced emission corresponds to a temperature excess of 800 K relative to the surrounding inner penumbral region and coincides with excess brightness in the 1330 and 1400 Å slit-jaw images of the Interface Region Imaging Spectrograph ( IRIS ), adjacent to a partial lightbridge. This λ = 3 mm brightness enhancement may be an intrinsic feature of the sunspot umbra at chromospheric heights, such as a manifestation of umbral flashes, or it could be related to a coronal plume, since the brightness enhancement was coincident with the footpoint of a coronal loop observed at 171 Å.

79 ASTRONOMY AND ASTROPHYSICS↗

EVOLUTION OF NEAR-SURFACE FLOWS INFERRED FROM HIGH-RESOLUTION RING-DIAGRAM ANALYSIS

Ring-diagram analysis of acoustic waves observed at the photosphere can provide a relatively robust determination of the sub-surface flows at a particular time under a particular region. The depth of penetration of the waves is related to the size of the region, hence the depth extent of the measured flows is inversely proportional to the spatial resolution. Most ring-diagram analysis has focused on regions of extent ∼15° (180 Mm) or more in order to provide reasonable mode sets for inversions. Helioseismic and Magnetic Imager (HMI) data analysis also provides a set of ring fit parameters on a scale three times smaller. These provide flow estimates for the outer 1% (7 Mm) of the Sun only, with very limited depth resolution, but with spatial resolution adequate to map structures potentially associated with the belts and regions of magnetic activity. There are a number of systematic effects affecting the determination of flows from a local helioseismic analysis of regions over different parts of the observable disk, and not all of them are well understood. In this study we characterize those systematic effects with higher spatial resolution so that they may be accounted for more effectively in mapping the temporal and spatial evolution of the flows. Leaving open the question of the mean structure of the global meridional circulation and the differential rotation, we describe the near-surface flow anomalies in time and latitude corresponding to the torsional oscillation pattern in differential rotation and analogous patterns in the meridional cell structure as observed by the Solar Dynamics Observatory/HMI.

79 ASTRONOMY AND ASTROPHYSICS↗

Towards a microchannel-based X-ray detector with two-dimensional spatial and time resolution and high dynamic range

X-ray detectors that combine two-dimensional spatial resolution with a high time resolution are needed in numerous applications of synchrotron radiation. Most detectors with this combination of capabilities are based on semiconductor technology and are therefore limited in size. Furthermore, the time resolution is often realised through rapid time-gating of the acquisition, followed by a slower readout. Here, a detector technology is realised based on relatively inexpensive microchannel plates that uses GHz waveform sampling for a millimeter-scale spatial resolution and better than 100 ps time resolution. The technology is capable of continuous streaming of time- and location-tagged events at rates greater than 10(7) events per cm(2). Time-gating can be used for improved dynamic range.

Adams, Bernhard W.↗

Advances in High Resolution Ultrafast Scintillators for Fast timing Applications

Scintillation detectors exhibiting high spatial resolution and fast timing capabilities are of vital importance for synchrotron sources. These detectors may be exposed to a variety of X-ray energies (up to 140 keV) and used in high frame rate applications. Here, we describe the advances in the development of thin-film LuI3:Ce scintillators for higher energy X-ray imaging, with fast timing and high spatial resolution. When grown in a single crystalline form, these scintillators are bright, producing 115 000 photons/MeV. However, to achieve high spatial resolution, these scintillators are grown in thin-film form with a microcolumnar structure, controllable to column diameters of <1-30 mu m. Thus, a much thicker scintillator layer (10 mu m-3 mm or higher) may be grown, providing superior X-ray absorption while achieving high resolutions of 50 mu m or better, at the cost of reduced light yield. To study the timing characteristics of the scintillator, time-resolved X-ray excited optical luminescence (TR-XEOL) was performed on two different sets of three samples of LuI3 at the 1-BM beamline of the Advanced Photon Source at Argonne National Laboratory. Besides, we report timing measurements obtained using a photomultiplier tube (PMT) and oscilloscope at Radiation Monitoring Devices (RMD) Inc. Using the TR-XEOL, we determined the decay constants of LuI3 as a function of Ce doping, recording a fast decay component as low as 3.6 ns (39%), one of the fastest values recorded in inorganic scintillators. This fast decay opens up numerous novel applications, where ultrahigh frame rates are important using synchrotron X-rays. This article will discuss fabrication, characterization, and potential applications for this novel scintillator.

fast timing↗

Noncircular aperture imaging system

Various technologies pertaining to an imaging system with a noncircular aperture are described herein. An imaging objective with a noncircular aperture and an anamorphic lens is used to capture a plurality of image frames of a scene. Each image frame is captured at a different rotational orientation of the imaging objective with respect to the scene. Each image frame has a non-uniform spatial resolution. A composite image of the scene is generated based upon the image frames. The composite image comprises a first region that has a spatial resolution that is approximately the same as a spatial resolution of an image generated using a circular objective with a diameter equal to the largest dimension of the noncircular aperture, and a second region with a lower spatial resolution.

Pitts, Todd↗

Regions in Energy Market Models

This report explores the different options for spatial resolution of an energy market model and the advantages and disadvantages of models with fine spatial resolution. It examines different options for capturing spatial variations, considers the tradeoffs between them, and presents a few examples from one particular model that has been run at different levels of spatial resolution.

EIA↗

Advances in imaging instrumentation for nuclear cardiology

Advances in imaging instrumentation and technology have greatly contributed to nuclear cardiology. Dedicated cardiac SPECT cameras incorporating novel, highly efficient detector, collimator, and system designs have emerged with the expansion of nuclear cardiology. Solid-state radiation detectors incorporating cadmium zinc telluride, which directly convert radiation to electrical signals and yield improved energy resolution and spatial resolution and enhanced count sensitivity geometries, are increasingly gaining favor as the detector of choice for application in dedicated cardiac SPECT systems. Additionally, hybrid imaging systems in which SPECT and PET are combined with X-ray CT are currently widely used, with PET/MRI hybrid systems having also been recently introduced. The improved quantitative SPECT/CT has the potential to measure the absolute quantification of myocardial blood flow and flow reserve. Rapid development of silicon photomultipliers leads to enhancement in PET image quality and count rates. In addition, the reduction of emission–transmission mismatch artifacts via application of accurate time-of-flight information, and cardiac motion de-blurring aided by anatomical images, are emerging techniques for further improvement of cardiac PET. This article reviews recent advances such as these in nuclear cardiology imaging instrumentation and technology, and the corresponding diagnostic benefits.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bragg Coherent Diffraction Imaging for In Situ Studies in Electrocatalysis

Electrocatalysis is at the heart of a broad range of physicochemical applications that play an important role in the present and future of a sustainable economy. Among the myriad of different electrocatalysts used in this field, nanomaterials are of ubiquitous importance. An increased surface area/volume ratio compared to bulk makes nanoscale catalysts the preferred choice to perform electrocatalytic reactions. Bragg coherent diffraction imaging (BCDI) was introduced in 2006 and since has been applied to obtain 3D images of crystalline nanomaterials. BCDI provides information about the displacement field, which is directly related to strain. Lattice strain in the catalysts impacts their electronic configuration and, consequently, their binding energy with reaction intermediates. Even though there have been significant improvements since its birth, the fact that the experiments can only be performed at synchrotron facilities and its relatively low resolution to date (~10 nm spatial resolution) have prevented the popularization of this technique. Herein, we will briefly describe the fundamentals of the technique, including the electrocatalysis relevant information that we can extract from it. Subsequently, we review some of the computational experiments that complement the BCDI data for enhanced information extraction and improved understanding of the underlying nanoscale electrocatalytic processes. We next highlight success stories of BCDI applied to different electrochemical systems and in heterogeneous catalysis to show how the technique can contribute to future studies in electrocatalysis. Finally, we outline current challenges in spatiotemporal resolution limits of BCDI and provide our perspectives on recent developments in synchrotron facilities as well as the role of machine learning and artificial intelligence in addressing them.

bragg coherent diffraction imaging↗

Spatial co-transcriptomics reveals discrete stages of the arbuscular mycorrhizal symbiosis

Abstract The symbiotic interaction of plants with arbuscular mycorrhizal (AM) fungi is ancient and widespread. Plants provide AM fungi with carbon in exchange for nutrients and water, making this interaction a prime target for crop improvement. However, plant–fungal interactions are restricted to a small subset of root cells, precluding the application of most conventional functional genomic techniques to study the molecular bases of these interactions. Here we used single-nucleus and spatial RNA sequencing to explore both Medicago truncatula and Rhizophagus irregularis transcriptomes in AM symbiosis at cellular and spatial resolution. Integrated, spatially registered single-cell maps revealed infected and uninfected plant root cell types. We observed that cortex cells exhibit distinct transcriptome profiles during different stages of colonization by AM fungi, indicating dynamic interplay between both organisms during establishment of the cellular interface enabling successful symbiosis. Our study provides insight into a symbiotic relationship of major agricultural and environmental importance and demonstrates a paradigm combining single-cell and spatial transcriptomics for the analysis of complex organismal interactions.

59 BASIC BIOLOGICAL SCIENCES↗