Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectral shape”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

The differential absorption hard x-ray spectrometer at the Z facility

The Differential Absorption Hard X-ray (DAHX) spectrometer is a diagnostic developed to measure time-resolved radiation between 60 keV and 2 MeV at the Z Facility. It consists of an array of 7 Si PIN diodes in a tungsten housing that provides collimation and coarse spectral resolution through differential filters. DAHX is a revitalization of the Hard X-Ray Spectrometer (HXRS) that was fielded on Z prior to refurbishment in 2006. DAHX has been tailored to the present radiation environment in Z to provide information on the power, spectral shape, and time profile of the hard emission by plasma radiation sources driven by the Z Machine.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantifying the effect of off-focal radiation on the output of kilovoltage x-ray systems

In a typical x-ray tube, off-focal radiation is mainly generated by the backscattered electrons that reenter the anode outside the focal spot. In this study, BEAMnrc (an EGSnrc user-code) is modified to simulate off-focal radiation. The modified BEAMnrc code is used to study the characteristics of electrons that backscatter from the anode, and to quantify their effect on the output of typical x-ray systems. Results show that the first generation backscatter coefficient is {approx}50% for tungsten anodes at diagnostic energies, and {approx}38% for molybdenum anodes at mammography energies. Second and higher generations of backscatter have a relatively minor contribution. At the patient plane, our simulation results are in excellent agreement with experimental measurements in the literature for the spectral shape of both the primary and the off-focal components, and also for the integral off-focal-to-primary ratio. The spectrum of the off-focal component at the patient plane is softer than the primary, which causes a slight softening in the overall spectrum. For typical x-ray systems, the off-focal component increases patient exposure (for a given number of incident primary electrons) by up to 11% and reduces the half-value layer and the effective energy of the average spectrum by up to 7% and 3%, respectively. The larger effects are for grounded cathode tubes, smaller interelectrode distance, higher tube voltage, lighter filtration, and less collimation. Simulation time increases by {approx}30% when the off-focal radiation is included, but the overall simulation time remains of the order of a few minutes. This study concludes that the off-focal radiation can have a non-negligible effect on the output parameters of x-ray systems and that it should be included in x-ray tube simulations for more realistic modeling of these systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Operation logic and functionality of automatic dose rate and image quality control of conventional fluoroscopy

New generation of fluoroscopic imaging systems is equipped with spectral shaping filters complemented with sophisticated automatic dose rate and image quality control logic called ''fluoroscopy curve'' or ''trajectory''. Such fluoroscopy curves were implemented first on cardiovascular angiographic imaging systems and are now available on conventional fluoroscopy equipment. This study aims to investigate the control logic operations under the fluoroscopy mode and acquisition mode (equivalent to the legacy spot filming) of a conventional fluoroscopy system typically installed for upper-lower gastrointestinal examinations, interventional endoscopy laboratories, gastrointestinal laboratory, and pain clinics.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A database for estimating organ dose for coronary angiography and brain perfusion CT scans for arbitrary spectra and angular tube current modulation

Purpose: The purpose of this study was to develop a database for estimating organ dose in a voxelized patient model for coronary angiography and brain perfusion CT acquisitions with any spectra and angular tube current modulation setting. The database enables organ dose estimation for existing and novel acquisition techniques without requiring Monte Carlo simulations. Methods: The study simulated transport of monoenergetic photons between 5 and 150 keV for 1000 projections over 360 Degree-Sign through anthropomorphic voxelized female chest and head (0 Degree-Sign and 30 Degree-Sign tilt) phantoms and standard head and body CTDI dosimetry cylinders. The simulations resulted in tables of normalized dose deposition for several radiosensitive organs quantifying the organ dose per emitted photon for each incident photon energy and projection angle for coronary angiography and brain perfusion acquisitions. The values in a table can be multiplied by an incident spectrum and number of photons at each projection angle and then summed across all energies and angles to estimate total organ dose. Scanner-specific organ dose may be approximated by normalizing the database-estimated organ dose by the database-estimated CTDI{sub vol} and multiplying by a physical CTDI{sub vol} measurement. Two examples are provided demonstrating how to use the tables to estimate relative organ dose. In the first, the change in breast and lung dose during coronary angiography CT scans is calculated for reduced kVp, angular tube current modulation, and partial angle scanning protocols relative to a reference protocol. In the second example, the change in dose to the eye lens is calculated for a brain perfusion CT acquisition in which the gantry is tilted 30 Degree-Sign relative to a nontilted scan. Results: Our database provides tables of normalized dose deposition for several radiosensitive organs irradiated during coronary angiography and brain perfusion CT scans. Validation results indicate total organ doses calculated using our database are within 1% of those calculated using Monte Carlo simulations with the same geometry and scan parameters for all organs except red bone marrow (within 6%), and within 23% of published estimates for different voxelized phantoms. Results from the example of using the database to estimate organ dose for coronary angiography CT acquisitions show 2.1%, 1.1%, and -32% change in breast dose and 2.1%, -0.74%, and 4.7% change in lung dose for reduced kVp, tube current modulated, and partial angle protocols, respectively, relative to the reference protocol. Results show -19.2% difference in dose to eye lens for a tilted scan relative to a nontilted scan. The reported relative changes in organ doses are presented without quantification of image quality and are for the sole purpose of demonstrating the use of the proposed database. Conclusions: The proposed database and calculation method enable the estimation of organ dose for coronary angiography and brain perfusion CT scans utilizing any spectral shape and angular tube current modulation scheme by taking advantage of the precalculated Monte Carlo simulation results. The database can be used in conjunction with image quality studies to develop optimized acquisition techniques and may be particularly beneficial for optimizing dual kVp acquisitions for which numerous kV, mA, and filtration combinations may be investigated.

60 APPLIED LIFE SCIENCES↗

Application of the diagnostic radiological index of protection to protective garments

Purpose: Previously, the diagnostic radiological index of protection (DRIP) was proposed as a metric for quantifying the protective value of radioprotective garments. The DRIP is a weighted sum of the percent transmissions of different radiation beams through a garment. Ideally, the beams would represent the anticipated stray radiation encountered during clinical use. However, it is impractical to expect a medical physicist to possess the equipment necessary to accurately measure transmission of scattered radiation. Therefore, as a proof of concept, the authors tested a method that applied the DRIP to clinical practice. Methods: Primary beam qualities used in interventional cardiology and radiology were observed and catalogued. Based on the observed range of beam qualities, five representative clinical primary beam qualities, specified by kV and added filtration, were selected for this evaluation. Monte Carlo simulations were performed using these primary beams as source definitions to generate scattered spectra from the clinical primary beams. Using numerical optimization, ideal scatter mimicking primary beams, specified by kV and added aluminum filtration, were matched to the scattered spectra according to half- and quarter-value layers and spectral shape. To within reasonable approximation, these theoretical scatter-mimicking primary beams were reproduced experimentally in laboratory x ray beams and used to measure transmission through pure lead and protective garments. For this proof of concept, the DRIP for pure lead and the garments was calculated by assigning equal weighting to percent transmission measurements for each of the five beams. Finally, the areal density of lead and garments was measured for consideration alongside the DRIP to assess the protective value of each material for a given weight. Results: The authors identified ideal scatter mimicking primary beams that matched scattered spectra to within 0.01 mm for half- and quarter-value layers in copper and within 5% for the shape function. The corresponding experimental scatter-mimicking primary beams matched the Monte Carlo generated scattered spectra with maximum deviations of 6.8% and 6.6% for half- and quarter-value layers. The measured DRIP for 0.50 mm lead sheet was 2.0, indicating that it transmitted, on average, 2% of incident radiation. The measured DRIP for a lead garment and one lead-alternative garment closely matched that for pure lead of 0.50 mm thickness. The DRIP for other garments was substantially higher than 0.50 mm lead (3.9–5.4), indicating they transmitted about twice as much radiation. When the DRIP was plotted versus areal density, it was clear that, of the garments tested, none were better than lead on a weight-by-weight basis. Conclusions: A method for measuring the DRIP for protective garments using scatter-mimicking primary beams was developed. There was little discernable advantage in protective value per unit weight for lead-alternative versus lead-only garments. Careful consideration must be given to the balance of protection and weight when choosing a lead-alternative protective garment with a lower specified “lead equivalence,” e.g., 0.35 mm. The DRIP has the potential to resolve this dilemma. Reporting the DRIP relative to areal density is an ideal metric for objective comparisons of protective garment performance, considering both protective value in terms of transmission of radiation and garment weight.

60 APPLIED LIFE SCIENCES↗

SU-F-T-166: On the Nature of the Background Visible Light Observed in Fiber Optic Dosimetry of Proton Beams

Purpose: The nature of the background visible light observed during fiber optic dosimetry of proton beams, whether it is due to Cherenkov radiation or not, has been debated in the literature recently. In this work, experimentally and by means of Monte Carlo simulations, we shed light on this problem and investigated the nature of the background visible light observed in fiber optics irradiated with proton beams. Methods: A bare silica fiber optics was embedded in tissue-mimicking phantoms and irradiated with clinical proton beams with energies of 100–225 MeV at Roberts Proton Therapy Center. Luminescence spectroscopy was performed by a CCD-coupled spectrograph to analyze in detail the emission spectrum of the fiber tip across the visible range of 400–700 nm. Monte Carlo simulation was performed by using FLUKA Monte Carlo code to simulate Cherenkov light and ionizing radiation dose deposition in the fiber. Results: The experimental spectra of the irradiated silica fiber shows two distinct peaks at 450 and 650 nm, whose spectral shape is different from that of Cherenkov radiation. We believe that the nature of these peaks are connected to the point defects of silica including oxygen-deficiency center (ODC) and non-bridging oxygen hole center (NBOHC). Monte Carlo simulations confirmed the experimental observations that Cherenkov radiation cannot be solely responsible for such a signal. Conclusion: We showed that Cherenkov radiation is not the dominant visible signal observed in bare fiber optics irradiated with proton beams. We observed two distinct peaks at 450 and 650 nm whose nature is connected with the point defects of silica fiber including oxygen-deficiency center and non-bridging oxygen hole center.

60 APPLIED LIFE SCIENCES↗

Near-field acoustical holography and acoustic power analysis of a simulated, highly heated supersonic jet

Although near-field acoustical holography (NAH) and acoustic intensity analysis have previously been used to investigate the apparent jet noise sources produced by military aircraft, explicit connections to supersonic jet characteristics cannot be made due to a lack of information about the exhaust plume. Here, to begin to bridge this gap and better understand the source information yielded by NAH, the current study instead applies NAH to a virtual measurement of the near-field pressures of a highly heated laboratory-scale supersonic jet generated by large-eddy simulation (LES). The holographic reconstructions of the pressure, particle velocity, and acoustic intensity are found to match the LES-generated acoustic field well and are used to calculate the acoustic power of the jet. The jet's calculated overall acoustic power is compared to the free-stream mechanical power, resulting in an acoustic efficiency of 1.5%. Ray-tracing of the acoustic intensity to the jet centerline generates an axial distribution of the acoustic power origin, showing that almost all the power originates from the supersonic portion of the flow and with the distribution peak upstream of the potential core tip. Holographic reconstruction of the pressures along the nozzle lipline captures the general spectral shape of the LES-generated pressures, though it underestimates the amplitude.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On the Possibility of the Precise Test of Interatomic Interaction Potentials Using the Effect of Anomalous Light-Induced Drift

The spectral features of the velocity of light-induced drift (LID) of lithium atoms in a neon buffer gas have been theoretically studied using four known ab initio calculated interatomic interaction potentials for the Li–Ne system of colliding particles. The calculations with each of these four potentials predict a strong temperature dependence of the spectral shape of the LID signal of Li atoms in the Ne atmosphere in various temperature intervals. The results allow the high-precision test of the interatomic interaction potentials in experiments on anomalous LID.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Direct neutrino mass measurements

The determination of the neutrino rest mass plays an important role at the intersections of cosmology, particle physics and astroparticle physics. This topic is currently being addressed by two complementary approaches in laboratory experiments. Neutrinoless double beta decay experiments probe whether neutrinos are Majorana particles and determine an effective neutrino mass value. Single beta decay experiments such as KATRIN and MARE investigate the spectral shape of β-decay electrons close to their kinematic endpoint in order to determine the neutrino rest mass with a model-independent method. Owing to neutrino flavour mixing, the neutrino mass parameter appears as an average of all neutrino mass eigenstates contributing to the electron neutrino. The KArlsruhe TRItium Neutrino experiment (KATRIN) is currently the experiment in the most advanced status of commissioning. Applying an ultra-luminous molecular windowless gaseous tritium source and an integrating high-resolution spectrometer of MAC-E filter type, it allows β-spectroscopy close to the T{sub 2} end-point with unprecedented precision and will reach a sensitivity of 200 meV/c{sup 2} (90% C.L.) on the neutrino rest mass.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Morphology, optical, and adsorption properties of copper-oxide layers deposited from complex compound solutions

A technique for synthesizing gas-sensing copper-oxide layers by layer-by-layer deposition onto glass and plastic substrates is considered. Deposition is based on the oxidation of a copper–ammonia complex by hydrogen peroxide. Layers synthesized at various numbers of deposition cycles are studied by atomicforce microscopy and transmission spectroscopy methods (300–1000 nm). The spectral shape indicates the mixed nature of the oxide with predominant copper oxide (I) Cu{sub 2}O with a corresponding band gap of 2.1 eV. The layers have a continuous granular structure. The surface concentration of Brönsted acid adsorption sites with pK{sub a} ≈ 2.5 (OH acid groups), determined by the indicator method, is 560 μmol/m{sup 2} for the initial films, and threefold increases after heat treatment at 80°C for 30 min. The results obtained are interesting for the use of the described technology for fabricating copper-oxide active layers in gas-sensing sensors operating at room temperature.

36 MATERIALS SCIENCE↗

Effect of Heat and Plasma Treatments on the Photoluminescence of Zinc-Oxide Films

The structure and electrical properties of ZnO films and the effect of annealing in a hydrogen-plasma atmosphere on the photoluminescence spectra of the films are studied. Short-term plasma treatment in a hydrogen atmosphere improves the electrical properties and brings about the appearance of an intense near-band-edge photoluminescence band. The heavy dependence of the intensity and spectral shape of nearband- edge photoluminescence on the conditions of preliminary annealing is observed. It is shown that the photoluminescence spectrum consists of several contributions. The effect of an ultraviolet-radiation-induced increase in the photoluminescence intensity is observed. The effect is reversible: the photoluminescence signal is intensified after exposure to ultraviolet radiation and reduced to the initial intensity upon keeping the samples in the dark. The nature of experimentally observed metastable shallow donors is discussed.

36 MATERIALS SCIENCE↗

Production of pions, kaons, (anti-)protons and ϕ mesons in Xe–Xe collisions at $\sqrt{s_{NN}}$ = 5.44 TeV

The first measurement of the production of pions, kaons, (anti-)protons and ϕ mesons at midrapidity in Xe–Xe collisions at $\sqrt{s_{NN}}$ = 5.44 TeV is presented. Transverse momentum (p T ) spectra and p T -integrated yields are extracted in several centrality intervals bridging from p–Pb to mid-central Pb–Pb collisions in terms of final-state multiplicity. The study of Xe–Xe and Pb–Pb collisions allows systems at similar charged-particle multiplicities but with different initial geometrical eccentricities to be investigated. A detailed comparison of the spectral shapes in the two systems reveals an opposite behaviour for radial and elliptic flow. In particular, this study shows that the radial flow does not depend on the colliding system when compared at similar charged-particle multiplicity. In terms of hadron chemistry, the previously observed smooth evolution of particle ratios with multiplicity from small to large collision systems is also found to hold in Xe–Xe. In addition, our results confirm that two remarkable features of particle production at LHC energies are also valid in the collision of medium-sized nuclei: the lower proton-to-pion ratio with respect to the thermal model expectations and the increase of the ϕ-to-pion ratio with increasing final-state multiplicity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Unraveling TeV halos with the Cherenkov Telescope Array

Pulsars are observed to emit bright and spatially extended gamma-ray emission at multi-TeV energies. These so-called "TeV halos" are now understood to be a nearly universal feature of middle-aged pulsars. However, many of the key physical processes that govern these systems, particularly those affecting particle diffusion, remain poorly constrained. We aim to evaluate the ability of the Cherenkov Telescope Array (CTA) to probe the physical properties of TeV halos, with a focus on the nearby and well-studied case of the Geminga pulsar. We simulate gamma-ray emission from various TeV halo models, incorporating different assumptions for the injected electron spectrum, spin-down evolution, and energy-dependent diffusion. These models are then used to forecast CTA's sensitivity to spectral and spatial differences, based on realistic mock observations and instrument response simulations. We find that CTA will be able to distinguish between a wide range of TeV halo models that are currently consistent with existing data. In particular, CTA observations can constrain the normalization, energy dependence, and spatial extent of the diffusion coefficient surrounding Geminga, as well as the spectral shape of the injected electron population.

79 ASTRONOMY AND ASTROPHYSICS↗

Vibronic and Environmental Effects in Simulations of Optical Spectroscopy

Including both environmental and vibronic effects is important for accurate simulation of optical spectra, but combining these effects remains computationally challenging. We outline two approaches that consider both the explicit atomistic environment and the vibronic transitions. Both phenomena are responsible for spectral shapes in linear spectroscopy and the electronic evolution measured in nonlinear spectroscopy. The first approach utilizes snapshots of chromophore-environment configurations for which chromophore normal modes are determined. We outline various approximations for this static approach that assumes harmonic potentials and ignores dynamic system-environment coupling. The second approach obtains excitation energies for a series of time-correlated snapshots. This dynamic approach relies on the accurate truncation of the cumulant expansion but treats the dynamics of the chromophore and the environment on equal footing. Both approaches show significant potential for making strides toward more accurate optical spectroscopy simulations of complex condensed phase systems.

Chemistry↗

Large-Eddy Simulations of Convection Initiation over Heterogeneous, Low Terrain

Abstract Large-eddy simulations are conducted to investigate and physically interpret the impacts of heterogeneous, low terrain on deep-convection initiation (CI). The simulations are based on a case of shallow-to-deep convective transition over the Amazon River basin, and use idealized terrains with varying levels of ruggedness. The terrain is designed by specifying its power-spectral shape in wavenumber space, inverting to physical space assuming random phases for all wave modes, and scaling the terrain to have a peak height of 200 m. For the case in question, these modest terrain fields expedite CI by up to 2–3 h, largely due to the impacts of the terrain on the size of, and subcloud support for, incipient cumuli. Terrain-induced circulations enhance subcloud kinetic energy on the mesoscale, which is realized as wider and longer-lived subcloud circulations. When the updraft branches of these circulations breach the level of free convection, they initiate wider and more persistent cumuli that subsequently undergo less entrainment-induced cloud dilution and detrainment-induced mass loss. As a result, the clouds become more vigorous and penetrate deeper into the troposphere. Larger-scale terrains are more effective than smaller-scale terrains in promoting CI because they induce larger enhancements in both the width and the persistence of subcloud updrafts.

54 ENVIRONMENTAL SCIENCES↗

Space to Air High-Altitude Region Adjoint Neutron Transport

Neutrons from an atmospheric nuclear explosion can be detected by sensors in orbit. Current tools for characterizing the neutron energy spectrum assume a known source and use forward transport to recreate the detector response. In realistic scenarios the true source is unknown, making this an inefficient, iterative approach. In contrast, the adjoint approach directly solves for the source spectrum, enabling source reconstruction. The time–energy fluence at the satellite and adjoint transport equation allow a Monte Carlo method to characterize the neutron source’s energy spectrum directly in a new model: the Space to High-Altitude Region Adjoint (SAHARA) model. A new adjoint source event estimator was developed in SAHARA to find feasible solutions to the neutron transport problem given the constraints of the adjoint environment. This work explores SAHARA’s development and performance for mono-energetic and continuous neutron energy sources. In general, the identified spectra were shifted towards energies approximately 5% lower than the true source spectra, but SAHARA was able to capture the correct spectral shapes. Continuous energy sources, including real-world sources Fat Man and Little Boy, resulted in identifiable spectra that could have been produced by the same distribution as the true sources as demonstrated by two-dimensional (2D) Kolmogorov–Smirnov tests.

LaMere, Zachary W.↗

Characteristics and selection of near-fault simulated earthquake ground motions for nonlinear analysis of buildings

Earthquake-induced ground shaking near rupturing faults is highly sensitive to the rupture characteristics, seismic wave propagation patterns and site conditions, and field recordings of near-fault shaking are relatively sparse. These challenges complicate the assessment of the seismic performance of near-fault structures. A common approach to representing near-fault ground motion in engineering analysis is to explicitly consider and select records with strong directivity pulses (pulse records). We use three-dimensional high-resolution physics-based earthquake simulations to test this approach in the context of scenario-based ground motion record selection, and to study the important characteristics of near-fault ground shaking. We highlight the deficiencies associated with classifying near-fault simulated records as “pulse” or “non-pulse,” based on the presence of a single dominating pulse in the velocity time history. We show that this approach is inadequate for characterizing near-fault shaking on soft soils which can be dominated by both forward rupture directivity and basin amplification effects. We conduct ground motion selection experiments for the analysis of near-fault structures with and without explicit classification of the pulse features in the records, and evaluate the bias in the predicted structural demands. We find that the maximum interstory drift demands on building structures imposed by unscaled site-specific simulated ground motion records selected based on relevant spectral shape features are not sensitive to the classification of records as pulse/non-pulse. Therefore, with regard to predicting the maximum interstory drifts in near-fault buildings, we do not find justification for the binary pulse classification of near-fault records.

42 ENGINEERING↗

SPECTRAL AMPLITUDE AND PHASE EVOLUTION IN PETAWATT LASER PULSES

The influence of the active gain medium on the spectral amplitude and phase of amplified pulses in a CPA system is studied. Results from a 10-PW example based on Nd-doped mixed glasses are presented. In conclusion, this study shows that, by using spectral shaping and gain saturation in a mixed-glass amplifier, it is possible to produce 124 fs, 1.4 kJ laser pulses. One detrimental effect, the pulse distortion due to resonant amplification medium, has been investigated and its magnitude as well as its compensation calculated.

42 ENGINEERING↗