Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Planar Rowland spectrometer for fiber-optic wavelength demultiplexing

A planar Rowland spectrometer was fabricated and characterized as a wavelength demultiplexer for multimode fiber-optic applications. The spectrometer consisted of a planar multimode glass waveguide with two curved end faces and a cylindrical concave attached to one of the end faces. Semiconductor lasers with wavelengths between 0.825 and 0.845 micron were used for the measurements. Cross-talk isolation between two adjacent fibers with center-to-center separation of 175 microns (100 A in wavelength difference) was measured to be 18 dB. The device's performance was limited by grating diffraction efficiency, optical aberration, waveguide dispersion, and waveguide losses.

Yen, H. W.↗

The neutral mass spectrometer on Dynamics Explorer B

A neutral gas mass spectrometer has been developed to satisfy the measurement requirements of the Dynamics Explorer mission. The mass spectrometer, a quadrupole, will measure the abundances of neutral species in the region 300-500 km in the earth's atmosphere. These measurements will be used in concert with other simultaneous observations on Dynamics Explorer to study the physical processes involved in the interactions of the magnetosphere-ionosphere-atmosphere system. The instrument, which is similar to that flown on Atmosphere Explorer, employs an electron beam ion source operating in the closed mode and a discrete dynode multiplier as a detector. The mass range is 22 to 50 amu. The abundances of atomic oxygen, molecular nitrogen, helium, argon, and possibly atomic nitrogen will be measured to an accuracy of about + or - 15% over the specified altitude range, with a temporal resolution of one second.

Carignan, G. R.↗

The Retarding Ion Mass Spectrometer on Dynamics Explorer-A

The thermal component of the magnetospheric plasma plays a key role in magnetosphere-ionosphere coupling processes, acting as a strong influence on ionospheric structure at low altitudes and as a source and modifier of the hotter plasma population at high altitudes. The Retarding Ion Mass Spectrometer (RIMS) instrument on Dynamics Explorer-A is designed to measure this important thermal plasma component. Using a combination of retarding potential analysis and magnetic ion mass spectrometer techniques, the RIMS instrument will measure the bulk plasma parameters of ion density (0.1 to 1,000,000 ions/cu cm), temperature (0-45 eV), and bulk flow (greater than 0.5 km/sec) in the inner plasmasphere and ionosphere, and the specific ion pitch angle and energy spectral characteristics in the outer plasmasphere and plasma trough for a mass range of 1-32 amu. The energy and mass spectral step sequences, as well as the multiplexing of the resultant data, can be tailored to accomplish a variety of thermal ion measurements throughout the inner magnetosphere.

Chappell, C. R.↗

Atmospheric ozone determination by solar occultation using the UV spectrometer on the Solar Maximum Mission

The UV spectrometer polarimeter instrument on the Solar Maximum Mission spacecraft has been used to measure ozone in the 53-75 km altitude interval by the technique of solar occultation. A 1 x 180 arcsec entrance aperture spectrometer with 0.04-A spectral resolution was employed. Resulting high-quality data are reduced by expressing measured UV attenuation as a Volterra integral equation. Solution of the equation is accomplished by expressing the integral in terms of a series representing the sum of ozone densities contained in concentric shells through tangent points separated by specified altitude increments. Sample ozone vs altitude profiles are presented for the equatorial region. These data show reproducibility to better than 10%. The density at 60 km is 7.3 + or - 0.15 x 10 to the 9th/cu cm for 2.5 deg latitude and longitudes between 81 and 105 deg west in September 1980. Density vs altitude profile exhibits changes in slope between 50 and 75 km.

Aikin, A. C.↗

Design and development of a fast ion mass spectrometer

Two Fast Ion Mass Spectrometers (FIMS A and FIMS B) were developed. The design, development, construction, calibration, integration, and flight of these instruments, along with early results from the data analysis efforts are summarized. A medium energy ion mass spectrometer that covers mass velocity space with significantly higher time resolution, improved mass resolution, (particularly for heavier ions), and wider energy range than existing instruments had achieved was completed. The initial design consisted of a dual channel cylindrical electrostatic analyzer followed by a dual channel cylindrical velocity filter. The gain versus count rate characteristics of the high current channel electron multipliers (CEM's), which were chosen for ion detection, revealed a systematic behavior that can be used as a criterion for selection of CEM's for long counting lifetimes.

Burch, J. L.↗

Imaging spectrometer technologies for advanced Earth remote sensing

A major requirement of multispectral imaging systems for advanced Earth remote sensing is the provision for greater spectral resolution and more versatile spectral band selection. The imaging spectrometer instrument concept provides this versatility by the combination of pushbroom imaging and spectrally dispersing optics using area array detectors in the focal plane. The shuttle imaging spectrometer concept achieves 10- and 20-meter ground instantaneous fields of view with 20-nanometer spectral resolution from Earth Orbit. Onboard processing allows the selection of spectral bands during flight; this, in turn, permits the sensor parameters to be tailored to the experiment objectives. Advances in optical design, infrared detector arrays, and focal plane cooling indicate the feasibility of the instrument concept and support the practicability of a validation flight experiment for the shuttle in the late 1980s.

Wellman, J. B.↗

Determining the operating characteristics of an ultraviolet interferometric spectrometer

A prototype interferometric spectrometer system is being built by NASA to explore the potential of the technique for applications involving the visible and near ultraviolet portions of the electromagnetic spectrum. The system is limited only by the frequency bandpass of the optical components used in the system, the quality of the optical components, and ultimately by the memory capacity of the computer; tradeoffs between the wavenumber resolution of the produced spectrum, the bandpass limits of the optics, and the number of samples obtained from the interferogram must be delineated explicitly. The prototype Ultraviolet Interferometric Spectrometer (UVIS) instrument is expected to be configured several different ways to ascertain its suitability for various applications. To exploit its inherent flexibility, this reference document describes these parameter tradeoffs.

Parsons, C. L.↗

Cooled grating array spectrometer for 0.6-5 microns

A grating spectrometer, designed to illuminate an array of 122 InSb photodiodes with minimum aberrations and maximum speed, has been constructed. The instrument will be used on the 5 meter Hale telescope at Palomar Observatory, and is easily adaptable to telescopes of various focal ratios. A resolving power of 100-1000 can be obtained at wavelengths between 0.6 microns and 5 microns with remotely interchangeable gratings. The spectrometer is sufficiently compact to fit on the 8-inch work surface of a commercially available dewar, and uses simple on-axis spherical and paraboloidal optical elements. The camera mirror produces an f/2.5 beam which, with the 0.2 mm detectors, allows a 3-in. focal-plane aperture on the 5 meter telescope. All rays fall within a 100 microns blur circle at all points along the array. Distortions have been corrected with a tilted field flattening lens in front of the detector.

Nordholt, J. E.↗

Near-infrared linear array spectrometer for space applications

A 128-element InSb linear detector array read out with a field effect transistor (FET) multiplexing scheme has been developed at the Jet Propulsion Laboratory. State-of-the-art NEP, uniform response, on-detector charge integration, and very low focal plane heat load compared to that of discrete detector arrays allows this type of array to open new possibilities for spaceborne near-infrared imaging spectrometers. Large number of cooled detector elements are feasible with the new technology, making it practical to design sensitive spectrometers even for spinning spacecraft where simultaneous wavelength coverage is necessary to avoid confusion of spatial with spectral variations.

Apt, J.↗

Tunable diode laser heterodyne spectrometer for remote observations near 8 microns

Infrared heterodyne spectroscopy is a passive technique employing coherent optical detection for the study of spectral features in remote sources. It employs optical components such as mirrors and lenses normally associated with incoherent optics, but because of it's coherent nature, it offers the advantages of ultrahigh spectral resolving power, high frequency precision, and diffraction limited field-of-view. Attention is given to the development of an ultrahigh resolution diode laser heterodyne spectrometer for observational and laboratory use. The instrument is designed for operation in the spectral range from 7.5 to 8.5 microns. A PbSe tuneable diode laser (TDL) is employed as local oscillator. A closed-cycle cooler is employed to keep the oscillator at operating temperatures in the range from 12 to 60 K. Attention is given to factors determining the TDL heterodyne sensitivity, the spectrometer design, and a survey of 8 micron observations, SiO could be detected in the sunspot spectrum.

Glenar, D. A.↗

Sighting of El Chichon sulfur dioxide clouds with the Nimbus 7 total ozone mapping spectrometer

The eruptions of El Chichon volcano on March 28 and April 3 and 4, 1982 were observed by the Nimbus 7 total ozone mapping spectrometer due to strong absorption by volcanic gases at the shortest wavelengths of the spectrometer (312.5 and 317.5 nm). These ultraviolet pictures permit a measurement of the volume, dispersion, and drift of volcanic gas clouds. The tropospheric clouds were rapidly dispersed in westerly winds while persistent stratospheric clouds drifted in easterly winds at speeds up to 13 m/sec. The spectral reflectance is consistent with sulfur dioxide absorption and rules out carbon disulfide as a major constituent. A preliminary estimate of the mass of sulfur dioxide deposited in the stratosphere by the large eruptions on April 3 and 4 is 3.3 million tons. Prior estimates of volcanic cloud volume were based on extrapolation of locally measured sulfur dioxide concentrations.

Krueger, A. J.↗

Imaging spectrometer - An advanced multispectral imaging concept

The concept of an imaging spectrometer, which is being studied as a potential Space Shuttle experiment, is evaluated as a 'push-broom' imager that includes a spectrometer to disperse each line of imaging information into its spectral components. Using this instrument, the dispersed energy falls upon a two-dimensional focal plane array that detects both spatial and spectral information. As the line field of view is advanced over the earth by the motion of the spacecraft, the focal plane is read out constantly, which produces 'push-broom' images at multiple wavelengths. Ground instantaneous fields of view of 10 m in the visual and 20 m in the infrared are provided by the system, at a spectral resolution of 20 nm over the range from 0.4-2.5 microns. The system utilizes a triple-pass Schmidt optical system with a mosaic focal plane. A subset of the data stream is selected and encoded for transmission by the use of onboard processing.

Wellman, J. B.↗

Tunable laser heterodyne spectrometer measurements of atmospheric species

It is pointed out that spectroscopic measurements conducted with the aid of tunable laser heterodyne spectrometers in the 3-30 micron range of the electromagnetic spectrum have the potential to measure the vertical profiles of tenuous gas molecules in the atmosphere with ultra high spectral resolution and great sensitivity. Programs related to the realization of this potential have been conducted for some time, and a Laser Heterodyne Spectrometer (LHS) experiment was developed. The present investigation has the objective to provide an overview of the LHS concept for measuring the vertical profiles of tenuous gas molecules in the upper atmosphere from space and airborne platforms, and to discuss the sensitivity ranges for this technique.

Allario, F.↗

Acoustic-optic spectrometer. 1: Noise contributions and system consideration

An acousto-optic spectrometer (AOS) used as an IF spectrometer to a heterodyne receiver is modeled as a total power multi-channel integrating receiver. Systematic noise contributions common to all total power, time integrating receivers, as well as noise terms unique to the use of optical elements and photo-detectors in an AOS are identified and discussed. In addition, degradation of signal-to-noise ratio of an unbalanced Dicke receiver compared to a balanced Dicke receiver is found to be due to gain calibration processing and is not an instrumental effect.

Chin, G.↗

Design of a precision etalon position control system for a cryogenic spectrometer

The Upper Atmosphere Research Satellite (UARS) will be launched in 1988 to study the distribution of a series of trace elements in the upper atmosphere and to study atmospheric dynamics. The UARS carries on board a cryogenically cooled infrared spectrometer to measure the concentration of a series of chemical species that are important for understanding the ozone layer in the stratosphere. This device, known as the Cryogenic Limb Array Etalon Spectrometer (CLAES), uses a multiposition filter wheel combined with tilt-scanned Fabry Perot etalons to obtain the high resolution required for these experiments. The CLAES optical system is sealed in a dewar where it is maintained at cryogenic temperatures by a supply of solid hydrogen. Operating temperatures for CLAES range from 130 K at the entrance aperture to 13 K at the focal plane. The design and test of a special control system using a unique actuator concept to provide position and can control for the CLAES etalon are described. Results of performance tests at cryogenic temperatures simulating the CLAES on-orbit environment are discussed.

Aubrun, J. N.↗

Ion mass spectrometer

An ion mass spectrometer is described which detects and indicates the characteristics of ions received over a wide angle, and which indicates the mass to charge ratio, the energy, and the direction of each detected ion. The spectrometer includes a magnetic analyzer having a sector magnet that passes ions received over a wide angle, and an electrostatic analyzer positioned to receive ions passing through the magnetic analyzer. The electrostatic analyzer includes a two dimensional ion sensor at one wall of the analyzer chamber, that senses not only the lengthwise position of the detected ion to indicate its mass to charge ratio, but also detects the ion position along the width of the chamber to indicate the direction in which the ion was traveling.

Neugebauer, M.↗

Imaging X-ray spectrometer

An X-ray spectrometer for providing imaging and energy resolution of an X-ray source is described. This spectrometer is comprised of a thick silicon wafer having an embedded matrix or grid of aluminum completely through the wafer fabricated, for example, by thermal migration. The aluminum matrix defines the walls of a rectangular array of silicon X-ray detector cells or pixels. A thermally diffused aluminum electrode is also formed centrally through each of the silicon cells with biasing means being connected to the aluminum cell walls and causes lateral charge carrier depletion between the cell walls so that incident X-ray energy causes a photoelectric reaction within the silicon producing collectible charge carriers in the form of electrons which are collected and used for imaging.

Grant, P. A.↗

Portable reflectance spectrometer

A portable reflectance spectrometer is disclosed. The spectrometer essentially includes an optical unit and an electronic recording unit. The optical unit includes a pair of thermoelectrically-cooled detectors, for detecting total radiance and selected radiance projected through a circular variable filter wheel, and is capable of operating to provide spectral data in the range 0.4 to 2.5 micrometers without requiring coventional substitution of filter elements. The electronic recording unit includes power supplies, amplifiers, and digital recording electronics designed to permit recordation of data on tape casettes. Both the optical unit and electronic recording unit are packaged to be manually portable.

Goetz, A. F. H.↗