Search NASA⌕ Search

SEARCH · Search NASA

Results for “Stack design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Solid oxide fuel cell power system development

This report summarizes the progress made during this contractual period in achieving the goal of developing the solid oxide fuel cell (SOFC) cell and stack technology to be suitable for use in highly-efficient, economically-competitive, commercially deployed electrical power systems. Progress was made in further understanding cell and stack degradation mechanisms in order to increase stack reliability toward achieving a 4+ year lifetime, in cost reduction developments to meet the SECA stack cost target of $175/kW (in 2007 dollars), and in operating the SOFC technology in a multi-stack system in a real-world environment to understand the requirements for reliably designing and operating a large, stationary power system.

30 DIRECT ENERGY CONVERSION↗

Air Dispersion Modeling for the INL Application for a Synthetic Minor Sitewide Air Quality Permit to Construct with a Facility Emission Cap Component

The Department of Energy Idaho Operations Office (DOE-ID) is applying for a synthetic minor, Sitewide, air quality permit to construct (PTC) with a facility emission cap (FEC) component from the Idaho Department of Environmental Quality (DEQ) for Idaho National Laboratory (INL) to limit its potential to emit to less than major facility limits for criteria air pollutants (CAPs) and hazardous air pollutants (HAPs) regulated under the Clean Air Act. This document is supplied as an appendix to the application, Idaho National Laboratory Application for a Synthetic Minor Sitewide Air Quality Permit to Construct with a Facility Emissions Cap Component, hereafter referred to as “permit application” (DOE-ID 2015). Air dispersion modeling was performed as part of the permit application process to demonstrate pollutant emissions from the INL will not cause a violation of any ambient air quality standards. This report documents the modeling methodology and results for the air dispersion impact analysis. All CAPs regulated under Section 109 of the Clean Air Act were modeled with the exception of lead (Pb) and ozone, which are not required to be modeled by DEQ. Modeling was not performed for toxic air pollutants (TAPs) as uncontrolled emissions did not exceed screening emission levels for carcinogenic and non-carcinogenic TAPs. Modeling for CAPs was performed with the EPA approved AERMOD dispersion modeling system (Version 14134) (EPA 2004a) and five years (2000-2004) of meteorological data. The meteorological data set was produced with the companion AERMET model (Version 14134) (EPA 2004b) using surface data from the Idaho Falls airport, and upper-air data from Boise International Airport supplied by DEQ. Onsite meteorological data from the Grid 3 Mesonet tower located near the center of the INL (north of INTEC) and supplied by the local National Oceanic and Atmospheric Administration (NOAA) office was used for surface wind directions and wind speeds. Surface data (i.e., land use data that defines roughness, albedo, Bowen ratio, and other parameters) were processed using the AERSURFACE utility (Version 13016) (EPA 2013). Emission sources were modeled as point sources using actual stack locations and dimensions. Emissions, flow rates and exit temperatures were based on the design operating capacity of each source. All structures close enough to produce an area of wake effect were included for all sources. For multi-tiered structures, the heights of the tiers were included or the entire building height was assumed to be equal to the height of the tallest tier. Concentrations were calculated at 1,352 receptor locations provided by DEQ. All receptors were considered for each pollutant and averaging period. Maximum modeled CAP concentrations summed with average background concentration values were presented and compared to National Ambient Air Quality Standards (NAAQS). The background concentration values used were obtained using the Washington State University’s Laboratory for Atmospheric Research North West Airquest web-based retrieval tool (http://lar.wsu.edu/nw airquest/lookup.html). The air dispersion modeling results show the maximum impacts for CAPs are less than applicable standards and demonstrate the INL will not cause a violation of any ambient air quality standards.

54 ENVIRONMENTAL SCIENCES↗

Renewable Firming EnergyFarm Final Report

The American Recovery and Reinvestment Act (ARRA) of 2009 (Recovery Act) provided the U.S. Department of Energy (DOE) with funds to modernize the electric power grid. One program under this initiative is the Smart Grid Demonstration program (SGDP). The SGDP mandate is to demonstrate how a suite of existing and emerging smart grid technologies can be innovatively applied and integrated to prove technical, operational, and business-model feasibility. Primus Power is a provider of low cost, long life and long duration energy storage systems. The Company’s flow batteries are shipping to US and international microgrid, utility, military, commercial and industrial customers. Primus Power’s EnergyPod® is a modular battery system for grid scale applications available in configurations ranging from 25 kW to more than 25 MW. The EnergyPod provides nameplate power for 5 hours. This long duration unlocks economic benefits on both sides of the electric meter. It allows commercial and industrial customers to shift low cost electricity purchased at night to offset afternoon electrical peaks to reduce utility demand charges. It also allows utilities to economically reduce power peaks and defer costly upgrades to distribution infrastructure. An EnergyPod contains one or more EnergyCells-a highly engineered flow battery core made from low cost, readily available materials. An EnergyCell includes a membrane-free stack of titanium electrodes located above a novel liquid electrolyte management system. This patented design enables reliable, low maintenance operation for decades. It is safe and robust, featuring non-flammable aqueous electrolyte, sophisticated fault detection and built-in secondary containment. Unlike Li Ion batteries, the EnergyCell is not susceptible to thermal runaway. This cooperative agreement project was started in Feb 2010. The objectives of the project are: 1. Trigger rapid adoption of grid storage systems in the US by demonstrating a low cost, robust and flexible EnergyFarm®. 2. Accelerate adoption of renewable energy and enhance grid stability by firming the output of wind & solar farms. 3. Demonstrate improved grid asset utilization by storing energy during off-peak periods for dispatch during local load peaks. 4. Establish an advanced battery manufacturing industry in the U.S. 5. Reduce CO2 emissions from utilities. This report summarizes the key milestones, data, results and lessons learned from the project. The desired goals and benefits of the cooperative agreement with the DOE have all been achieved. The project has contributed to reducing power costs, accelerating adoption of renewable energy resources, reducing greenhouse gas emissions and establishing advanced battery manufacturing in the U.S. The Recovery Act funds provided thru the DOE have been leveraged multiple times by additional private equity investment. Primus Power continues to ship low cost, long life and long duration EnergyPod® flow battery systems to utilities, commercial/industrial, microgrid and data center customers. After the conclusion of this project, Primus Power has modified the EnergyPod® design to optimize around energy performance. Primus Power has moved to a prefabricated enclosure instead of multiple EnergyCells in a container. This lowers capital and maintenance costs and can optimize site design. Utilities are starting to adopt energy storage for a variety of functions. The market will grow as the technology is proven and profitable applications expand.

25 ENERGY STORAGE↗

Accelerated Testing Validation

The DOE Fuel Cell technical team recommended ASTs were performed on 2 different MEAs (designated P5 and HD6) from Ballard Power Systems. These MEAs were also incorporated into stacks and operated in fuel cell bus modules that were either operated in the field (three P5 buses) in Hamburg, or on an Orange county transit authority drive cycle in the laboratory (HD6 bus module). Qualitative agreement was found in the degradation mechanisms and rates observed in the AST and in the field. The HD6 based MEAs exhibited lower voltage degradation rates (due to catalyst corrosion) and slower membrane degradation rates in the field as reflected by their superior performance in the high potential hold and open-circuit potential AST tests. The quantitative correlation of the degradation rates will have to take into account the various stressors in the field including temperature, relative humidity, start/stops and voltage cycles.

08 HYDROGEN↗

Development of a Mechanistic-Based Healing Model for Self-Healing Glass Seals

Self-healing glass, a recent development of hermetic sealant materials, has the ability to effectively repair damage when heated to elevated temperatures; thus, able to extend its service life. Since crack healing morphological changes in the glass material are usually temperature and stress dependent, quantitative studies to determine the effects of thermo-mechanical conditions on the healing behavior of the self-healing glass sealants are extremely useful to accommodate the design and optimization of the sealing systems within SOFCs. The goal of this task is to develop a mechanistic-based healing model to quantify the stress and temperature dependent healing behavior. A two-step healing mechanism was developed and implemented into finite element (FE) models through user-subroutines. Integrated experimental/kinetic Monte Carlo (kMC) simulation methodology was taken to calibrate the model parameters. The crack healing model is able to investigate the effects of various thermo-mechanical factors; therefore, able to determine the critical conditions under which the healing mechanism will be activated. Furthermore, the predicted results can be used to formulate the continuum damage-healing model and to assist the SOFC stack level simulations in predicting and evaluating the effectiveness and the performance of various engineering seal designs.

Fuel Cell↗

Assessment of MiniFuel Subcapsule Design Recommendations on Previous Experiments

MiniFuel describes the class of separate effects nuclear fuels irradiation experiments that have been conducted in the High Flux Isotope Reactor (HFIR) since 2018. These experiments comprise a stack of six fuel-bearing subcapsules contained in a stainless steel target housing that is in contact with HFIR coolant on its exterior. All MiniFuel targets have a near-standardized architecture, and the primary design variables that change between experiments are the radial gap size between the subcapsule and housing and the target fill gas composition. Finite element heat transfer models are used to determine the optimum gas composition and gap sizes, and recent studies were performed to identify model parameters that contribute the most uncertainty to fuel specimen temperature predictions. That work, which is referenced herein, also recommended a set of design modifications to the subcapsule internal architecture and assembly process. These modifications are intended to reduce fuel temperature uncertainty in future experiments. In this report, the subcapsule design modifications were retroactively applied to a previously conducted MiniFuel experiment to determine how these changes affect the established safety and performance envelope of the experimental capability. These effects were determined in two steps. First, the modifications were applied to the subcapsule design without any other changes to determine their isolated effect on the predicted fuel specimen temperatures. This portion of the analysis showed that fuel temperatures were modestly reduced because the implemented changes improved heat transfer efficacy. Next, traditional MiniFuel design activities (i.e., sizing the gas gaps and determining the fill gas composition) were reperformed, and they confirmed that the original desired fuel temperatures could be achieved while remaining within established safety limits. Therefore, this report demonstrates improved performance resulting from the subcapsule modifications, which mitigate uncertainty while meeting the objectives of past experiments. An additional benefit of the design changes is reduced sensitivity of the fuel temperature to the evolving flux spectrum in HFIR, leading to more stable temperatures and enhanced utility of MiniFuel as a separate effects irradiation platform.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cummins R-SOFC System Development

The overall purpose of this project was to reduce the Reversible-Solid Oxide Fuel Cell (R-SOFC) system cost by developing two technologies, an improved cell design and the incorporation of an ejector in the fuel recycle loop instead of a blower. A Simulink model of the baseline SOFC system was developed and calibrated with experimental test data. The R-SOFC system model was built by integrating GT Suite developed models of the steam generation components into the baseline Simulink SOFC system model. The ability to run the stack in SOEC operating mode was also added to the model. The system model was used to explore the ability of the R-SOFC system to meet operational constraints on Steam/Carbon ratio and H2 concentration on the fuel side electrode. A CFD ejector model was developed and used to explore a range of ejector design parameters, leading to the final ejector design that was prototyped for testing. A prototype steam ejector was first tested in a laboratory environment using room temperature air. The steam ejector was subsequently tested using the full hot recycle loop with all relevant heat exchangers and steam generation components. The test conditions utilized temperatures, pressures, and flow rates expected in an R-SOFC application. Throughout the experimental testing work, ejector performance test data was used to improve and then validate the CFD ejector model. A CFD cell model was developed and used to optimize thermal gradients, voltage, and cost of a new cell substrate design. A CFD comparison of co-flow and cross-flow cell designs informed the decision to use a co-flow design for the new cell substrate. Multiple rounds of CFD simulation were used to improve the cell design to minimize the variation in air and fuel distribution across cell channels and to minimize the variation in air and fuel distribution across different cells in the stack. A few prototypes of the new cell substrate design were produced and validated in a laboratory environment by thermally spraying and verifying that they met established manufacturing specifications. The cell manufacturing process was adjusted in order to bring these metrics within acceptable tolerances. Cummins’ internal calculations show that the new cell design reduces cost ~50% compared to the baseline cell, while the ejector + superheater/boiler concept reduces cost of the recycle loop by ~40%. The impact of these cost reductions on the cost of producing H2 will depend on the specific system where they are applied. Therefore, a Techno-Economic Analysis was completed using system cost as a variable, and showing how the NREL Current and Future system costs translate into H2 production cost.

Henrichsen, Lars↗

Decoupling between Shockley partials and stacking faults strengthens multiprincipal element alloys

We report that mechanical properties are fundamental to structural materials, where dislocations play a decisive role in describing their mechanical behavior. Although the high-yield stresses of multiprincipal element alloys (MPEAs) have received extensive attention in the last decade, the relation between their mechanistic origins remains elusive. Our multiscale study of density functional theory, atomistic simulations, and high-resolution microscopy shows that the excellent mechanical properties of MPEAs have diverse origins. The strengthening effects through Shockley partials and stacking faults can be decoupled in MPEAs, breaking the conventional wisdom that low stacking fault energies are coupled with wide partial dislocations. This study clarifies the mechanistic origins for the strengthening effects, laying the foundation for physics-informed predictive models for materials design.

36 MATERIALS SCIENCE↗

Plasma-beam traps and radiofrequency quadrupole beam coolers

Two linear trap devices for particle beam manipulation (including emittance reduction, cooling, control of instabilities, dust dynamics, and non-neutral plasmas) are here presented, namely, a radiofrequency quadrupole (RFQ) beam cooler and a compact Penning trap with a dust injector. Both beam dynamics studies by means of dedicated codes including the interaction of the ions with a buffer gas (up to 3 Pa pressure), and the electromagnetic design of the RFQ beam cooler are reported. The compact multipurpose Penning trap is aimed to the study of multispecies charged particle samples, primarily electron beams interacting with a background gas and/or a micrometric dust contaminant. Using a 0.9 T solenoid and an electrode stack where both static and RF electric fields can be applied, both beam transport and confinement operations will be available. The design of the apparatus is presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and characterization of terahertz-absorbing nano-laminates of dielectric and metal thin films

A terahertz-absorbing thin-film stack, containing a dielectric Bragg reflector and a thin chromium metal film, was fabricated on a silicon substrate for applications in bi-material terahertz (THz) sensors. The Bragg reflector is to be used for optical readout of sensor deformation under THz illumination. The THz absorption characteristics of the thin-film composite were measured using Fourier transform infrared spectroscopy. The absorption of the structure was calculated both analytically and by finite element modeling and the two approaches agreed well. Finite element modeling provides a convenient way to extract the amount of power dissipation in each layer and is used to quantify the THz absorption in the multi-layer stack. The calculation and the model were verified by experimentally characterizing the multi-layer stack in the 3-5 THz range. The measured and simulated absorption characteristics show a reasonably good agreement. It was found that the composite film absorbed about 20% of the incident THz power. The model was used to optimize the thickness of the chromium film for achieving high THz absorption and found that about 50% absorption can be achieved when film thickness is around 9 nm.

36 MATERIALS SCIENCE↗

Theory-guided design of high-entropy alloys with enhanced strength-ductility synergy

Abstract Metallic alloys have played essential roles in human civilization due to their balanced strength and ductility. Metastable phases and twins have been introduced to overcome the strength-ductility tradeoff in face-centered cubic (FCC) high-entropy alloys (HEAs). However, there is still a lack of quantifiable mechanisms to predict good combinations of the two mechanical properties. Here we propose a possible mechanism based on the parameter κ, the ratio of short-ranged interactions between closed-pack planes. It promotes the formation of various nanoscale stacking sequences and enhances the work-hardening ability of the alloys. Guided by the theory, we successfully designed HEAs with enhanced strength and ductility compared with other extensively studied CoCrNi-based systems. Our results not only offer a physical picture of the strengthening effects but can also be used as a practical design principle to enhance the strength-ductility synergy in HEAs.

36 MATERIALS SCIENCE↗

Radiation Shielding Calculations for E1039 Seaquest Experiment

The E1039 Seaquest experiment is designed to study results of interactions of the 120 GeV proton beam, delivered from Main Injector, with transversely polarized hydrogen target in the form of liquid ammonia (NH3). The E1039 experiment is re-using the Neutrino-Muon beamline, spectrometer magnet (FMAG), KMAG, and other hardware from its predecessor—the E906 experiment. Only the central 2 Tesla magnetic field was modeled in the FMAG magnet which also serves also as a beam absorber. Various updates were performed to the beamline and shielding around the magnet compared to E906 including relocation of the target 3 meters upstream of the front face of FMAG. Further, several updates were performed on the MARS15 model developed previously [1-2] in order to better describe important surrounding areas, in particular the counting room. Several optimization iterations of the shielding design were done and only the final configuration is discussed in this document. The model includes realistically stacked concrete shielding blocks along with airgaps required for piping, ductwork and detectors. The main features of the shielding update can be summarized as follows: (i) additional concrete shielding was added above the magnet to degrade the energy of neutrons to thermal levels; (ii) a new target alcove with the target cryostat inside. These updates are intended to provide increased protection for both normal operation and accident conditions upstream of the target. The Figures 1 thru 3 below describe the MARS15 model in detail as well as an excerpt of the 3D CAD model design which was used to build the MARS15 model.

43 PARTICLE ACCELERATORS↗

Demonstration of Electrochemically-Driven CO 2 Separation Using Hydroxide Exchange Membranes

Hydroxide exchange membrane fuel cells (HEMFCs) are a potentially lower-cost hydrogen fuel cell technology; however, ambient levels of CO 2 in air significantly reduce HEMFCs’ performance. In this work, we demonstrate an electrochemically-driven CO 2 separator (EDCS) which can be used to remove ambient levels of CO 2 from air upstream of the HEMFC stack in fuel cell vehicles, protecting it from CO 2 -related performance losses. The EDCS operating window was explored for current density, anode flow, and cathode flow with respect to its impact on CO 2 separation performance. Additionally, gas-phase mass transport was improved by selecting flow fields and gas diffusion layers conducive to the EDCS operating regime. The use of a carbon-ionomer interlayer at the cathode was explored and improved CO 2 removal performance from 77.7% to 98.2% at 20 mA cm −2 . An analytical, 1-D model is used to explain the experimental observations and design improvements. A single-cell, 25 cm 2 EDCS using the aforementioned improved design demonstrated greater than 98% CO 2 removal at a cathode flow rate of 1300 sccm for 100 h with 2.7% hydrogen stack consumption.

Matz, Stephanie↗

MPACT Fast Neutron Multiplicity System Prototype Development

This document serves as both an FY2103 End-of-Year and End-of-Project report on efforts that resulted in the design of a prototype fast neutron multiplicity counter leveraged upon the findings of previous project efforts. The prototype design includes 32 liquid scintillator detectors with cubic volumes 7.62 cm in dimension configured into 4 stacked rings of 8 detectors. Detector signal collection for the system is handled with a pair of Struck Innovative Systeme 16-channel digitizers controlled by in-house developed software with built-in multiplicity analysis algorithms. Initial testing and familiarization of the currently obtained prototype components is underway, however full prototype construction is required for further optimization. Monte Carlo models of the prototype system were performed to estimate die-away and efficiency values. Analysis of these models resulted in the development of a software package capable of determining the effects of nearest-neighbor rejection methods for elimination of detector cross talk. A parameter study was performed using previously developed analytical methods for the estimation of assay mass variance for use as a figure-of-merit for system performance. A software package was developed to automate these calculations and ensure accuracy. The results of the parameter study show that the prototype fast neutron multiplicity counter design is very nearly optimized under the restraints of the parameter space.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of a Multi-Rotor Triboelectric Nanogenerator Using a Modular Flexible Circuit Board Stack

Triboelectric nanogenerators (TENGs) are a nascent class of energy harvester that are being explored for scavenging energy from small ocean waves. To date, they have been integrated in wave energy converters (WECs) designed to capture random motion caused by the perturbations of the ocean surface. Blue economy applications such as ocean observation can benefit greatly from more substantial wave-derived power, as such, the power output of existing TENG WECs must be increased several-fold to become viable. This study describes the conceptualization of a rotary TENG, and the subsequent efforts to increase its power output by stacking multiple stator and rotor pairs. In the latter part of this study, we introduce a novel means of incorporating a friction element into the design of the TENG by employing flexible printed circuit board (PCB) rotors. At rest, these flexible rotors will contact the stator, building static charges due to friction, at speed, these flexible rotors will be decoupled from the stator, reducing friction and allowing faster rotation. Initial results indicate that the power output of the flexible PCB rotor does not produce more power than a rigid, acrylic disk rotor, however the current output of the prototype is boosted, and the prototype is far more compact, allowing for a higher energy density than the rigid rotor prototype.

bench testing↗

Conceptual Design of the Transformational Challenge Reactor

The Transformational Challenge Reactor is a 3-MW(thermal) helium-cooled experimental nuclear reactor designed using an additive manufacturing–informed agile design process. This design process leverages rapid prototyping and advanced materials from emerging additive manufacturing technologies, key characteristics that enable rapid design maturation. The resulting core design incorporates a blend of advanced reactor technologies into an intermediate-spectrum microreactor, including conventionally manufactured tristructural isotropic (TRISO) fuel particles in an advanced manufactured SiC fuel element and a solid yttrium hydride moderator encapsulated in steel. Matured during the design effort, these technologies are incorporated with additively manufactured steel support and fluidic structures to form a 75-cm-outer-diameter cylindrical active core region. Below and above the active core region are axial SiC reflectors, which are housed inside the reactor pressure vessel. The reactor is controlled with an annular shroud actuated external to the pressure vessel in the gap between the pressure vessel and a steel radial reflector. A safety rod is at the center of the core to shut down the reactor when necessary. Helium pressurized at 5 MPa is forced into the pressure vessel below the core and around the core to the top plenum before it is forced down through the axial reflectors and the active core region. The primary pressurized helium loop is operated up to 500°C and includes the pressure vessel, the circulator, and the hot side of a helium-to-air heat exchanger. The secondary loop rejects all heat from the primary loop to ambient air through a heat exchanger. A vented temporary confinement building contains the entire primary loop, with penetrations for a stack, cooling, and the secondary ambient air loop. Finally, this is the first advanced nuclear microreactor designed using additive manufacturing technologies, demonstrating their applicability in an accelerated advanced design process.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Assessment of the Group 3-4 (HV-S1, HV-S2, IHLW-S1) Stack Sampling Probe Locations for Compliance with ANSI/HPS N13.1-1999

This document reports on a series of tests conducted to assess the proposed air sampling locations for the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Group 3-4 exhaust stacks with respect to the applicable criteria regarding the placement of an air sampling probe. The HV-S1, HV-S2, and IHLW-S1 exhaust stacks were tested together as a group (Test Group 3-4) because they share a geometric attribute: the common factor in their design is that the last significant flow disturbance upstream of the air sampling probe is a jog (i.e., two conjoined bends of equal and opposite curvature resulting in a change in elevation of the duct). Federal regulations require that a sampling probe be located in the exhaust stack according to criteria established by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. These criteria address the capability of the sampling probe to extract a sample that represents the effluent stream.

Glissmeyer, John A.↗

Novel pore size-controlled, susceptibility matched, 3D-printed MRI phantoms

We report the design concept and fabrication of MRI phantoms, containing blocks of aligned microcapillaires that can be stacked into larger arrays to construct diameter distribution phantoms or fractured, to create a “powder-averaged” emulsion of randomly oriented blocks for vetting or calibrating advanced MRI methods, that is, diffusion tensor imaging, AxCaliber MRI, MAP-MRI, and multiple pulsed field gradient or double diffusion-encoded microstructure imaging methods. The goal was to create a susceptibility-matched microscopically anisotropic but macroscopically isotropic phantom with a ground truth diameter that could be used to vet advanced diffusion methods for diameter determination in fibrous tissues. Two-photon polymerization, a novel three-dimensional printing method is used to fabricate blocks of capillaries. Double diffusion encoding methods were employed and analyzed to estimate the expected MRI diameter. Susceptibility-matched microcapillary blocks or modules that can be assembled into large-scale MRI phantoms have been fabricated and measured using advanced diffusion methods, resulting in microscopic anisotropy and random orientation. This phantom can vet and calibrate various advanced MRI methods and multiple pulsed field gradient or diffusion-encoded microstructure imaging methods. We demonstrated that two double diffusion encoding methods underestimated the ground truth diameter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗