Search NASA⌕ Search

SEARCH · Search NASA

Results for “Staging Building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

NASA’s Space Launch System: Progress Toward Launch

The Space Launch System (SLS), NASA’s cornerstone launch capability for a new generation of deep space exploration, has begun assembly at Kennedy Space Center (KSC) in preparation for launch in 2021. SLS will provide an unparalleled launch capability for human and robotic deep space exploration missions. Its proven propulsion system, upgrade path to more powerful vehicles, and high-volume payload fairings make it the foundation for ambitious and demanding as part of the Artemis program. Artemis is NASA’s 21st-century plan to put boots on the Moon and to perform sustainable, long-term science in deep space, with eyes toward sending explorers to Mars. The initial SLS vehicle to fly, Block 1 in the crew configuration – with the new Orion spacecraft – is scheduled to lift off from revitalized launch facilities at KSC in 2021 for an uncrewed test flight known as Artemis I. Manufacturing is complete on the vehicle and all elements have been delivered to the Exploration Ground Systems (EGS) Program, except the core stage. The program’s all-new development, the core stage is currently in the midst of a “Green Run” test campaign at Stennis Space Center (SSC). Eight progressively more challenging tests in the Green Run series will culminate in a hot-fire of four flight-proven liquid hydrogen/liquid oxygen (LH2/LOX) RS25 engines. Following the Green Run hotfiring, the core stage will ship to KSC. Already at KSC, aft sections of the fivesegment solid rocket boosters are being assembled. Previously delivered elements, including the upper stage, are undergoing final checkouts in preparation for stacking. An exciting 2021 will include such milestones as stacking SLS and Orion in KSC’s Vehicle Assembly Building (VAB), modal testing, roll out to Launch Pad 39B, Wet Dress Rehearsal (WDR), and launch. Teams across the country are preparing for launch by finalizing procedures, defining launch constraints and flight rules, training console operators, performing simulations, and more. With the SLS Block 1 vehicle for Artemis I nearing integration and launch, the second Block 1 vehicle in the crew configuration, which will carry astronauts on an Artemis II hybrid lunar flyby mission, has several elements manufactured. In fact, the solid rocket motor segments and RS-25 engines are complete. Those program elements are processing hardware for the third flight and working toward manufacturing the second SLS variant to fly, Block 1B, which will onramp a powerful new upper stage, the Exploration Upper Stage (EUS).

John Honeycutt↗

Open Building Control

Best practice control sequences are often not implemented correctly, or are not implemented at all, in large commercial buildings. This typically leads to 10-30 percent energy waste, along with reduced occupant productivity and unnecessary equipment wear. The current process of designing and implementing such control sequences is a manual process that starts with designers who often don’t have adequate training, then requires controls programmers to interpret and program a verbose written sequence. This process has been shown to fail to deliver high performance control sequences at scale. The Open Building Control project digitizes the current control delivery process. The project is developing tools for system designers to select control sequences, assess their energy performance and load flexibility potential using whole building simulation, specify the sequence for implementation using machine-to-machine translation by a control provider and formally testing the as-installed sequences by a commissioning agent. The project developed tools for each stage of this delivery process. The key innovation of the project is the development of the Control Description Language, a language that allows such a digitized control delivery process with end-to-end verification. Libraries of control sequences have been implemented using the Control Description Language, and their performance has been demonstrated using whole building energy simulation. An automated translation of such sequences to a commercial control product line has been conducted using a prototype translator. Tools for formal verification of as-installed control sequences relative to their specification have been developed and demonstrated. The American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) started the process of forming a committee to make this language an ASHRAE/ANSI Standard. This new standard will complement existing and emerging ASHRAE standards for building communication and semantic modeling by providing a standard for expressing the control logic - the actual brain of the building. We expect this language and the process it enables to be an important contribution to the deployment of high performance building control sequences at scale because it allows taming the complexity of the control delivery process, which is continually increasing due to the need for higher performance and increased load flexibility to meet goals for net zero energy and increased renewable integration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy and environmental consequences of a cool pavement campaign

Raising the albedo (solar reflectance) of streets can lower outside air temperature, reduce building energy use, and improve air quality in cities. However, the production and installation of pavement maintenance and rehabilitation treatments with enhanced albedo (“cool” pavements) may entail more or less energy consumption and carbon emission than that of less-reflective treatments. We developed several case studies in which a cool surface treatment is substituted for a more typical treatment (that is, a cool technology is selected instead of a more typical technology). We then assessed over a 50-year analysis period the changes in primary energy demand (PED, excluding feedstock energy) and global warming potential (GWP, meaning carbon dioxide equivalent) in Los Angeles and Fresno, California. The analysis considers two stages of the pavement life cycle: materials and construction (MAC), comprising material production, transport, and construction; and use, scoped as the influence of pavement albedo on cooling, heating, and lighting energy consumption in buildings. In Los Angeles, substituting a styrene acrylate reflective coating or a chip seal for a slurry seal in routine maintenance, or a bonded concrete overlay on asphalt (BCOA) without supplementary cementitious materials (SCM) for mill-and-fill asphalt concrete in conventional or long-life rehabilitation, induced MAC-stage PED and GWP penalties that substantially exceeded use-stage savings, primarily due to material production. Modified rehabilitation cases in which SCM comprised 21% to 50% of the BCOA's total cementitious content by mass (portland cement + SCM) yielded smaller total (MAC + use) PED and GWP penalties, or even total PED and GWP savings. Trends in Fresno were similar, with some differences in GWP outcomes that result from Fresno's longer heating season. The modified rehabilitation cases using BCOA with high SCM content yielded total GWP savings in each city; all other cases yielded total GWP penalties. Here, the magnitude of the one-time GWP offset offered by global cooling from the increased albedo itself always, and sometimes greatly, exceeded the 50-year total GWP penalty or savings. In Los Angeles, the annual building conditioning (cooling + heating) PED and energy cost savings intensities yielded by cool pavements were each about an order of magnitude smaller than the corresponding savings from cool roofs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Probing the deep nonlinear stage of the ablative Rayleigh-Taylor instability in indirect drive experiments on the National Ignition Facility

Academic tests in physical regimes not encountered in Inertial Confinement Fusion will help to build a better understanding of hydrodynamic instabilities and constitute the scientifically grounded validation complementary to fully integrated experiments. Under the National Ignition Facility (NIF) Discovery Science program, recent indirect drive experiments have been carried out to study the ablative Rayleigh-Taylor Instability (RTI) in transition from weakly nonlinear to highly nonlinear regime [A. Casner et al., Phys. Plasmas 19, 082708 (2012)]. In these experiments, a modulated package is accelerated by a 175 eV radiative temperature plateau created by a room temperature gas-filled platform irradiated by 60 NIF laser beams. The unique capabilities of the NIF are harnessed to accelerate this planar sample over much larger distances (≃1.4 mm) and longer time periods (≃12 ns) than previously achieved. This extended acceleration could eventually allow entering into a turbulent-like regime not precluded by the theory for the RTI at the ablation front. Simultaneous measurements of the foil trajectory and the subsequent RTI growth are performed and compared with radiative hydrodynamics simulations. We present RTI growth measurements for two-dimensional single-mode and broadband multimode modulations. The dependence of RTI growth on initial conditions and ablative stabilization is emphasized, and we demonstrate for the first time in indirect-drive a bubble-competition, bubble-merger regime for the RTI at ablation front.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Kinetically Controlled Linker Binding in Rare Earth-2,5-Dihydroxyterepthalic Acid Metal–Organic Frameworks and Its Predicted Effects on Acid Gas Adsorption

In the pursuit of highly stable and selective metal–organic frameworks (MOFs) for the adsorption of caustic acid gas species, an entire series of rare earth MOFs have been explored. Each of the MOFs in this series (RE-DOBDC; RE = La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, and Lu; DOBDC = 2,5-dihydroxyterepthalic acid) was synthesized in the tetragonal space group I4/m. Crystallized MOF samples, specifically Eu-DOBDC, were seen to have a combination of monodentate and bidentate binding when synthesized under typical reaction conditions, resulting in a contortion of the structure. However, extended crystallization times determined that this binding is kinetically controlled and that the monodentate binding option was crystallographically eliminated by extended reaction times at higher temperatures. Furthermore, this series allows for the direct study of the effect of the metal center on the structure of the of the MOF; herein, the lanthanide metal ionic radii contraction across the periodic table results in a reduction of the MOF pore size and lattice parameters. Scanning electron microscopy–energy-dispersive spectroscopy was used to investigate the stages of crystal growth for these RE-DOBDC MOFs. All MOFs, except Er-DOBDC had a minimum of two stages of growth. These analogues were demonstrated by analysis of neutron diffraction (PND) to exhibit a cooperative rotational distortion of the secondary building unit, resulting in two crystallographically distinct linker sublattices. Computational modeling efforts were used to show distinct differences on acid gas (NO 2 and SO 2 ) binding energies for RE-DOBDC MOFs when comparing the monodentate/bidentate combined linker with the bidentate-only linker crystal structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lights, Camera, Action ... and Cooling - The case for centralized low carbon energy at Fox Studios

Fox Studios partnered with the U.S. Department of Energy (DOE) to develop and implement solutions to retrofit two production stages and one of its central cooling plants, to reduce energy consumption by at least 30% as part of DOE’s Commercial Building Partnerships (CBP) Program. Although this case study reports expected savings arising from proposed design recommendations for a unique building type and the unusual load characteristics associated with its use, the EEMs implemented for the central plant are applicable to any large campus, office and higher education facility. The intent is that by making the energy-efficiency measures (EEMs) set that were assessed as cost-effective from this project applicable to a larger number of buildings on the campus Fox Studios will be able to implement an integrated campus-wide energy strategy for the long term. The significant challenges for this project in the design phase included identifying how to assess and analyze multiple system types, develop a coherent strategy for assessment and analysis, implement the measurement and verification activities to collect the appropriate data (in terms of capturing ‘normal’ operating characteristics and granularity) and determine the best approach to providing cooling to the site buildings based on the nature of existing systems and the expected improvement in energy performance of the central cooling plant. The analytical framework adopted provides a blueprint for similar projects at other large commercial building campuses.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Computer-Aided Modeling and Analysis of Power Processing Systems (CAMAPPS). Phase 1: Users handbook

The EASY5 macro component models developed for the spacecraft power system simulation are described. A brief explanation about how to use the macro components with the EASY5 Standard Components to build a specific system is given through an example. The macro components are ordered according to the following functional group: converter power stage models, compensator models, current-feedback models, constant frequency control models, load models, solar array models, and shunt regulator models. Major equations, a circuit model, and a program listing are provided for each macro component.

Kim, S.↗

Gear Damage Detection Using Oil Debris Analysis

The purpose of this paper was to verify, when using an oil debris sensor, that accumulated mass predicts gear pitting damage and to identify a method to set threshold limits for damaged gears. Oil debris data was collected from 8 experiments with no damage and 8 with pitting damage in the NASA Glenn Spur Gear Fatigue Rig. Oil debris feature analysis was performed on this data. Video images of damage progression were also collected from 6 of the experiments with pitting damage. During each test, data from an oil debris sensor was monitored and recorded for the occurrence of pitting damage. The data measured from the oil debris sensor during experiments with damage and with no damage was used to identify membership functions to build a simple fuzzy logic model. Using fuzzy logic techniques and the oil debris data, threshold limits were defined that discriminate between stages of pitting wear. Results indicate accumulated mass combined with fuzzy logic analysis techniques is a good predictor of pitting damage on spur gears.

Dempsey, Paula J.↗

Solar Electric Propulsion (SEP) Tug Power System Considerations

Solar electric propulsion (SEP) technology is truly at the "intersection of commercial and military space" as well as the intersection of NASA robotic and human space missions. Building on the use of SEP for geosynchronous spacecraft station keeping, there are numerous potential commercial and military mission applications for SEP stages operating in Earth orbit. At NASA, there is a resurgence of interest in robotic SEP missions for Earth orbit raising applications, 1-AU class heliocentric missions to near Earth objects (NEOs) and SEP spacecraft technology demonstrations. Beyond these nearer term robotic missions, potential future human space flight missions to NEOs with high-power SEP stages are being considered. To enhance or enable this broad class of commercial, military and NASA missions, advancements in the power level and performance of SEP technologies are needed. This presentation will focus on design considerations for the solar photovoltaic array (PVA) and electric power system (EPS) vital to the design and operation of an SEP stage. The engineering and programmatic pros and cons of various PVA and EPS technologies and architectures will be discussed in the context of operating voltage and power levels. The impacts of PVA and EPS design options on the remaining SEP stage subsystem designs, as well as spacecraft operations, will also be discussed.

Kerslake, Thomas W.↗

Building Environmental Justice and Equity into the Development of Critical Mineral Industries

The global transition toward low-carbon energy not only means an increase in demand for clean electricity and renewable resources, but also an increase in demand for the critical minerals (CMs) and rare earth elements (REEs) that these technologies rely upon. Indeed, low-carbon energy technologies, such as those used for wind turbines and electric vehicle motors, require significantly more lithium, nickel, cobalt, manganese, graphite, and other CMs than fossil-based energy technologies. The growing demand for new forms of low- carbon energy will necessitate a proportional scale-up of CM and REE extraction and processing. Presently, the majority of extraction and processing activities for CMs and REEs are concentrated in very few countries, primarily in China and the Global South. CM and REE supply chain activities conducted in or controlled by these countries are commonly associated with widespread and well- documented human rights abuses and environmental degradation. As a result of concerns related to supply chain security, worker welfare, and the overall need for additional sources of CMs and REEs, governments worldwide have begun to explore policy pathways for the development of new supply chains. The development of new supply chains for CMs and REEs re s a multifold opportunity to accelerate the global deployment of low-carbon energy fleets, reduce global carbon emissions, build political resilience—and also to enhance policy objectives of environmental justice and equity in the clean energy transition. Fulfilling these policy objectives requires energy producers to navigate a maze of global supply chain policies designed to shape and accelerate the growth of new markets. In the United States, for instance, President Biden recently implemented fiscal and trade policies that incentivize both domestic and global reliance on U.S.-produced CMs and REEs, leveraging key relationships in Asia and Europe to ensure the accelerated buildout of the U.S. supply chain. The Biden Administration’s framework also emphasizes that new supply chains for CMs, REEs, and other low-carbon energy pathways must generate benefits for marginalized and disadvantaged communities, build energy equity, and contribute to the Biden Administration’s vision of environmental justice. present CM and REE supply chains include several stages, including mining, processing, transport, utilization, and disposal, each of which involves different environmental justice considerations and potential injustices. This study explores how technical innovation, paired with responsible community engagement and empowerment, can help inform the development of energy equity and environmental justice at all stages of new supply chains. The study highlights these opportunities on a broad scale. We also lend a specific focus to research at the University of Wyoming School of Energy Resources that aims to guide the development of CM and REE industries in communities with high economic dependence on coal and other fossil fuel industries, identifying pathways to grow a U.S. domestic supply chain by producing CMs from coal, coal by-products, and coal waste streams. These production pathways represent a potential new supply for CMs across the U.S. and elsewhere, thereby enhancing national security and accelerating the widespread deployment of low-carbon energy technologies, while also generating alternative applications for remaining coal reserves and aiding in a just transition for rural energy-producing communities.

Gerace, Selena↗

Ice Thermal Storage Systems for LWR Supplemental Cooling and Peak Power Shifting

Availability of enough cooling water has been one of the major issues for the nuclear power plant site selection. Cooling water issues have frequently disrupted the normal operation at some nuclear power plants during heat waves and long draught. The issues become more severe due to the new round of nuclear power expansion and global warming. During hot summer days, cooling water leaving a power plant may become too hot to threaten aquatic life so that environmental regulations may force the plant to reduce power output or even temporarily to be shutdown. For new nuclear power plants to be built at areas without enough cooling water, dry cooling can be used to remove waste heat directly into the atmosphere. However, dry cooling will result in much lower thermal efficiency when the weather is hot. One potential solution for the above mentioned issues is to use ice thermal storage systems (ITS) that reduce cooling water requirements and boost the plant’s thermal efficiency in hot hours. ITS uses cheap off-peak electricity to make ice and uses those ice for supplemental cooling during peak demand time. ITS is suitable for supplemental cooling storage due to its very high energy storage density. ITS also provides a way to shift large amount of electricity from off peak time to peak time. Some gas turbine plants already use ITS to increase thermal efficiency during peak hours in summer. ITSs have also been widely used for building cooling to save energy cost. Among three cooling methods for LWR applications: once-through, wet cooling tower, and dry cooling tower, once-through cooling plants near a large water body like an ocean or a large lake and wet cooling plants can maintain the designed turbine backpressure (or condensation temperature) during 99% of the time; therefore, adding ITS to those plants will not generate large benefits. For once-through cooling plants near a limited water body like a river or a small lake, adding ITS can bring significant economic benefits and avoid forced derating and shutdown during extremely hot weather. For the new plants using dry cooling towers, adding the ice thermal storage systems can effectively reduce the efficiency loss and water consumption during hot weather so that new LWRs could be considered in regions without enough cooling water. \ This paper presents the feasibility study of using ice thermal storage systems for LWR supplemental cooling and peak power shifting. LWR cooling issues and ITS application status will be reviewed. Two ITS application case studies will be presented and compared with alternative options: one for once-through cooling without enough cooling for short time, and the other with dry cooling. Because capital cost, especially the ice storage structure/building cost, is the major cost for ITS, two different cost estimation models are developed: one based on scaling method, and the other based on a preliminary design using Building Information Modeling (BIM), an emerging technology in Architecture/Engineering/Construction, which enables design options, performance analysis and cost estimating in the early design stage.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Hybrid Solar System (Final Scientific/Technical Report)

GTI Energy (GTI) teamed with the University of California at Merced (UCM) to scaleup the hybrid solar system (HSS) technology for demonstrating its performance at the US Gypsum (USG) plant in Plaster City, California. The technology integrates two-stage concentrating solar collector with matching particle thermal transport and storage (TSS) system to deliver cost-effective, and on-demand distributed high temperature industrial process heat up to 600°C with solar thermal, in this case to a gypsum kettle, to reduce its fuel use and carbon footprint. Current solar technologies, which reach these temperatures, are not distributable (towers) or cost-effective (dish). The research team developed a conceptual system design for host site retrofit, including preliminary heat balance, process flow diagram, particle to process heat exchanger and equipment placements at the site. Subsequently, parallel efforts were carried out at UCM to design, build and test a 12 m long commercial scale prototype concentrating thermal-only collector system and at GTI to design, build and test a matching 650°C capable particle TTS system. The nominal 50 kWth collector consists of a parabolic trough and three 4 m long two-stage receivers in series. Prior to on-sun testing, a 4 m long receiver was fabricated and successfully tested at 650 °C in a laboratory setting for 100 hrs of continuous operation showing less than 15% radiation loss. A 7 m wide x 17 m long parabolic trough was then installed at UCM for on-sun testing of the 12 m long receiver, and concurrently several 4 m long receivers were built. The optics of the parabolic trough were calibrated, and on-sun test were carried out on 12 m long receivers. During tests, the intense solar radiation (53x) caused the absorber tubes in the receivers to bend, reducing the overall optical efficiency. To address the bending issue, a self-consistent algorithm that includes ray tracing, thermal and deformation models was developed to perform thermal stress analysis on absorbers for parabolic solar collectors. Results obtained with this algorithm showed a dramatic rise in deformation as absorber tube length increases. A combined efficiency parameter that includes the occluded area for the mounts was developed to obtain an optimized tube length obtained. Based on the results, a length of 2.7 m for the absorber + 0.2 m for the coupler was chosen to minimize any bending and optimize optical efficiency while maintaining ease of mounting. The associated particle TTS system was designed, built and successfully tested at GTI. It includes storage, receiving and lock hoppers and piping that simulates the transfer of captured solar energy to an actual industrial furnace. Tests over 77 charge-discharge cycles demonstrated <2% particle degradation, with no problematic particle accumulations and no flow interruptions. The piping pressure drop was about 5 psi. The team also worked with Stanley Consultants (Stanley) to prepare conceptual and preliminary engineering packages to facilitate follow-on development and commercialization efforts. These include process and instrumentation diagram’s (P&ID’s), general arrangements, electrical one-line, project definitions document, equipment data sheets, schedule, and construction cost estimate for 2 MWth system. Updated HSS technology commercialization and customer engagement plans and detailed costs and evaluated market trade-offs and manufacturing.

03 NATURAL GAS↗

Effects of Solar Photovoltaic Panels on Roof Heat Transfer

Building Heating, Ventilation and Air Conditioning (HVAC) is a major contributor to urban energy use. In single story buildings with large surface area such as warehouses most of the heat enters through the roof. A rooftop modification that has not been examined experimentally is solar photovoltaic (PV) arrays. In California alone, several GW in residential and commercial rooftop PV are approved or in the planning stages. With the PV solar conversion efficiency ranging from 5-20% and a typical installed PV solar reflectance of 16-27%, 53-79% of the solar energy heats the panel. Most of this heat is then either transferred to the atmosphere or the building underneath. Consequently solar PV has indirect effects on roof heat transfer. The effect of rooftop PV systems on the building roof and indoor energy balance as well as their economic impacts on building HVAC costs have not been investigated. Roof calculator models currently do not account for rooftop modifications such as PV arrays. In this study, we report extensive measurements of a building containing a flush mount and a tilted solar PV array as well as exposed reference roof. Exterior air and surface temperature, wind speed, and solar radiation were measured and thermal infrared (TIR) images of the interior ceiling were taken. We found that in daytime the ceiling surface temperature under the PV arrays was significantly cooler than under the exposed roof. The maximum difference of 2.5 C was observed at around 1800h, close to typical time of peak energy demand. Conversely at night, the ceiling temperature under the PV arrays was warmer, especially for the array mounted flat onto the roof. A one dimensional conductive heat flux model was used to calculate the temperature profile through the roof. The heat flux into the bottom layer was used as an estimate of the heat flux into the building. The mean daytime heat flux (1200-2000 PST) under the exposed roof in the model was 14.0 Watts per square meter larger than under the tilted PV array. The maximum downward heat flux was 18.7 Watts per square meters for the exposed roof and 7.0 Watts per square meters under the tilted PV array, a 63% reduction due to the PV array. This study is unique as the impact of tilted and flush PV arrays could be compared against a typical exposed roof at the same roof for a commercial uninhabited building with exposed ceiling and consisting only of the building envelope. Our results indicate a more comfortable indoor environment in PV covered buildings without HVAC both in hotter and cooler seasons.

Dominguez, A.↗

Performance Evaluation of Three RTU Energy Efficiency Technologies

This project was part of an effort by CLEAResult and ComEd to evaluate the energy saving potential of emerging technologies in the Chicago area. This project focused on evaluating emerging technologies related to rooftop units (RTUs). An RTU with a single-stage compressor and a constant-speed fan with an induction motor was selected as the baseline for technology comparison. Three retrofit strategies were investigated. The first two involved replacing the single-stage compressor of an RTU by either a two-stage or variable-speed compressor and adding a variable frequency drive (VFD) to the constant speed fan. The use of a multi-/variable-stage compressor improves the part-load efficiency of the compressor which will ultimately result in annual energy savings as well as peak demand shaving in some cases where the design capacity of the RTU is larger than the maximum cooling load of the building space that it is serving. The third technology was the use of a high rotor pole switched reluctance motor (SRM) as a replacement for the constant-speed supply fan. The SRM was applied in single-speed, two-stage and variable-speed compressor RTUs. SRM motors run via reluctance torque. Their stator poles are driven by direct current (DC) power and require an inverter as well as active control when using alternating current (AC) power. This inherent property results in high efficiency over a range of operating conditions. It also exhibits higher efficiency compared to variable frequency drives (VFDs) since its switching frequency is much slower (SCE, 2018).The three technologies investigated are summarized below: 1) Replacing the single-speed compressor with a two-stage compressor and adding a VFD to the supply fan. 2)Replacing the single-speed compressor with a variable-speed compressor and adding a VFD to the supply fan. 3) Replacing the constant-speed induction motor of the supply fan with a high rotor pole SRM. DOE’s building simulation platform EnergyPlus and its graphical user interface OpenStudio were used to evaluate the energy-saving potential of upgrading RTUs, by leveraging experimental data from previous research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Retro-Commissioning Sensor Suitcase for Energy Efficiency

This project will enable Pacific Northwest National Laboratory (PNNL) and Lawrence Berkeley National Laboratory (LBNL) to work with industry partner, GreenPath Energy Solutions, joint developers of the Suitcase, to enhance the capabilities and usability of the Retro-Commissioning Sensor Suitcase (hereinafter the Sensor Suitcase or Suitcase), assisting GreenPath to take the Suitcase to market and rapidly expand their market share. The proposed project will specifically focus on 1) adding sensors types to extend the data collection capability and support more building and equipment performance metrics and identification of even more energy saving opportunities, 2) developing algorithms to identify recommendations for the new energy savings opportunities from item 1 and to prototype software modifications implementing them, 3) validating the use of vibration sensors to detect the operating state of a broader set of packaged HVAC equipment (additional capacities, different numbers of stages, etc.) than tested in initial development and modifying the state algorithm and software code, as needed, 4) improving cost-effectiveness in manufacturing the Sensor Suitcase, and 5) additional field testing of the technology in real buildings to more comprehensively validate Suitcase performance and to guide refinement of its capabilities. Project results will position GreenPath, and potential future licensees, to implement the new capabilities developed in this project in GreenPath’s RCx Building Suitcase, increasing its functionality and the savings resulting from its use. These enhancements will increase the value of the Suitcase to users and increase the potential market for its use and impacts in that impact.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Repair and Utilization of the Kratos XSAM 800 X-Ray Photoelectron Spectrometer (XPS)

The objectives for this summer faculty fellowship were first to repair the Kratos XSAM 800 X-ray Photoelectron Spectrometer (XPS) and then to utilize the instrument to participate in ongoing research projects at KSC and in the researcher's own laboratory at UCF. The first 6 weeks were used in repairing the instrument. Working both alone and with the Kratos service engineer, a number of hardware problems, largely associated with the sample stage control system, were corrected. Defective parts were identified and fixed in the computer driver boards, the stage power supply, and the driver interface. The power supply was completely replaced. After four weeks of work, the instrument was functional. This occurred on a Wednesday. The following Friday the instrument had to be completely shut down because the power to the O & C Building was to be turned off. The instrument was properly secured. On Monday, the instrument was powered up and the original problems returned. After another 2 weeks of work, a software problem was identified. This problem caused the computer to use a defective port for the sample stage control. It was circumvented by rewriting the startup routine. The final 3 weeks of the fellowship were spent using the XPS to analyze samples being studied in the Langley materials project (Martha Williams) and a catalyst project (Dr. Orlando Melendez). During this time, several sample analysis requests from other groups at KSC also came in and those samples were run as well. The summer faculty fellowship also allowed many contacts to be made. After meeting with the sensors group, two projects were identified for collaboration and white papers are being prepared. One project aims to develop small, very sensitive hydrogen detectors and the other to develop a broad area, easily monitored, zero power consumption hydrogen detector. In addition to the work mentioned above, the XPS was utilized in a study underway in Dr. Hampton's laboratory at UCF.

Hampton, Michael D.↗

Optimizing Charge-coupled Device Readout Enabled by the Floating-gate Amplifier

Multiple-Amplifier Sensing (MAS) charge-coupled devices (CCDs) have recently been shown to be promising silicon detectors that meet noise sensitivity requirements for next generation Stage-5 spectroscopic surveys and potentially, future space-based imaging of extremely faint objects on missions such as the Habitable Worlds Observatory. Building upon the capability of the Skipper CCD to achieve deeply sub-electron noise floors, MAS CCDs utilize multiple floating-gate amplifiers along the serial register to increase the readout speed by a factor of the number of output nodes compared to a Skipper CCD. We introduce and experimentally demonstrate on a 16-channel prototype device new readout techniques that exploit the MAS CCD’s floating-gate amplifiers to optimize the correlated double sampling by resetting once per line instead of once per pixel. With this new mode, we find an optimal filter to subtract the noise from the signal during read out. We also take advantage of the MAS CCD’s structure to tune the read time by independently changing integration times for the signal and reference level. Together with optimal weighted averaging of the 16 outputs, these approaches enable us to reach a sub-electron noise of 0.9 e − rms pix −1 at 19 μs pix −1 for a single charge measurement per pixel—simultaneously giving a 30% faster readout time and 10% lower read noise compared to performance previously evaluated without these techniques.

Lin, Kenneth W. (ORCID:0000000189672281)↗

Feasibility of using the Massively Parallel Processor for large eddy simulations and other Computational Fluid Dynamics applications

The results of an investigation into the feasibility of using the MPP for direct and large eddy simulations of the Navier-Stokes equations is presented. A major part of this study was devoted to the implementation of two of the standard numerical algorithms for CFD. These implementations were not run on the Massively Parallel Processor (MPP) since the machine delivered to NASA Goddard does not have sufficient capacity. Instead, a detailed implementation plan was designed and from these were derived estimates of the time and space requirements of the algorithms on a suitably configured MPP. In addition, other issues related to the practical implementation of these algorithms on an MPP-like architecture were considered; namely, adaptive grid generation, zonal boundary conditions, the table lookup problem, and the software interface. Performance estimates show that the architectural components of the MPP, the Staging Memory and the Array Unit, appear to be well suited to the numerical algorithms of CFD. This combined with the prospect of building a faster and larger MMP-like machine holds the promise of achieving sustained gigaflop rates that are required for the numerical simulations in CFD.

Bruno, John↗