At least 469 records · Page 26

Development of an international security standard for devices containing high-activity radioactive sources

Radioisotopes such as Cs-137 and Co-60 are utilized in various medical, industrial, and research applications. This radiological material can be a theft or sabotage target, which necessitates a certain level of security to adequately protect it. The presented work will explore the necessity of an international security standard for devices used in clinical settings that contain high activity radiological material and the facilities that contain these devices. This standard intends to complement existing safety standards; however, it serves a very different purpose: to reduce the threat of radiological theft and sabotage while taking into full consideration the effect on the patient, user safety, and patient workflow with the aim to minimize the unwanted effects of the security measures. The proposed standard will complement existing International Atomic Energy Agency (IAEA) guidance, published in the IAEA Nuclear Security Series. While those documents primarily focus on the state, competent authorities, and regulatory agencies, the proposed industry standard will involve device manufacturers, source producers, and medical staff.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PMK 1000 cone-socket ventilator fittings force testing to ISO 5356-1:2015 Standard

This memo summarizes the results of verification tests on a cone-socket fitting to the ISO 5356-1:2015 standard, annexes B and F. The components were found to meet requirements holding 50N tensile force and more than 35 N-cm of torque for 10 seconds without separating at 35°C with a fresh socket. Humidity control was unavailable; consequently, humidity was significantly lower than the values in the ISO standard. Several repeat tests of the fitting with force, torque, and time excursions give us confidence that the fittings perform suitably to the ISO standard. Force overload tests suggest that the samples will disengage under tension at around 69 N, while torque overload tests under a force of 50 N will fail at 79 N-cm of torque. If repeated tests are performed on the same component, the socket can deform and lead to the connection failing the standard requirements. However, such failures only occur with repeated testing, and the gripping of such units can be modified so that they pass the standard. This observation demonstrates that socket gripping is responsible for those failures and would not be a problem in application.

42 ENGINEERING↗

Impacts of Standard 90.1-2007 for Commercial Buildings at State Level

This nationwide analysis of commercial energy code compares ASHRAE Standard 90.1-2007 with the commercial code in each state as of June 2009. The results are provided in chapters specific to each state. States with unique energy codes were not included in the analysis because the codes in these states would be difficult to appropriately compare to ASHRAE Standard 90.1 and most of these states have energy offices that routinely assess their codes against the model codes. In states with codes prior to and including the 2000 IECC or Standard 90.1-1999, those states with no statewide energy code, and home rule states which did not specifically request that another code be used, Standard 90.1-1999 was used as the baseline for comparison. Three DOE benchmark buildings were used for the simulation used in this analysis: a medium office building (53,600 square feet), a mid-rise apartment building (33,700 square feet), and a non-refrigerated warehouse (49,500 square feet) - representing ASHRAE Standard 90.1 non-residential, residential, and semi-heated requirements, respectively. Locations for the analysis were selected based on obtaining a sample representative of each climate zone in the state, where typical meteorological year (TMY2) weather file locations existed, making sure to include the state capital. In the absence of a TMY2 weather file for a particular climate zone in a state, a representative location in an adjacent state was used for the purposes of the simulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Distributed Energy Resource Cybersecurity Standards Development [Final Report]

Currently, the solar industry is operating with little application-specific guidance on how to protect and defend their systems from cyberattacks. This 3-year Department of Energy (DOE) Solar Energy Technologies Office-funded project helped advance the distributed energy resource (DER) cybersecurity state-of-the-art by (a) bolstering industry awareness of cybersecurity concepts, risks, and solutions through a webinar series and (b) developing recommendations for DER cybersecurity standards to improve the security performance of DER products and networks. Drafting DER standards is a lengthy, consensus-based process requiring effective leadership and stakeholder participation. This project was designed to reduce standard and guide writing times by creating well-researched recommendations that could act as a starting place for national and international standards development organizations. Working within the SunSpec/Sandia DER Cybersecurity Workgroup, the team produced guidance for DER cybersecurity certification, communication protocol standards, network architecture s, access control, and patching. The team also led subgroups within the IEEE P 1547.3 Guide for Cybersecurity of Distributed Energy Resources Interconnected with Electric Power Systems committee and pushed a draft to ballot in October 2021.

14 SOLAR ENERGY↗

Commercial, industrial, and institutional discount rate estimation for efficiency standards analysis: Sector-level data 1998–2021

Underlying each of the Department of Energy’s (DOE’s) federal appliance and equipment energy conservation standards are a set of complex analyses of the projected costs and benefits of regulation. Any new or amended standard must be designed to achieve significant additional energy conservation, provided that it is technologically feasible and economically justified (42 U.S.C. 6295(o)(2)(A)). DOE determines economic justification based on whether the benefits exceed the burdens, considering a variety of factors, including the economic impact of the standard on consumers of the product and the savings in lifetime operating cost compared to any increase in price or maintenance expenses (42 U.S.C. 6295(o)(2)(B)). As part of this determination, DOE conducts a Life-Cycle Cost (LCC) analysis, which models the combined impact of appliance first cost and operating cost changes on a representative commercial building sample in order to identify the fraction of customers achieving LCC savings or incurring net cost at the considered efficiency levels. Thus, the commercial discount rate value(s) used to calculate the present value of energy cost savings within the LCC model implicitly plays a role in estimating the economic impact of potential standard levels. This report provides an in-depth discussion of the commercial discount rate estimation process. It is an update to previous reports on estimating commercial discount rates from firm-level financial data (Fujita, 2016). Major topics covered in this report include: Discount rate estimation methods and rationale; -Data sources used and data limitations; -Discount rate distributions for use in standards analysis; -Discount rate estimation methods and distributions specific to the small business subgroup analysis. Going forward, this report will be updated as data allow and analyses necessitate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial, industrial, and institutional discount rate estimation for efficiency standards analysis: Sector-level data 1998–2022

Underlying each of the U.S. Department of Energy’s (DOE’s) federal appliance and equipment energy conservation standards are a set of complex analyses of the projected costs and benefits of regulation. Any new or amended standard must be designed to achieve significant additional energy conservation, provided that it is technologically feasible and economically justified (42 U.S.C. 6295(o)(2)(A)). DOE determines economic justification based on whether the benefits exceed the burdens, considering a variety of factors, including the economic impact of the standard on consumers of the product and the savings in lifetime operating cost compared to any increase in price or maintenance expenses (42 U.S.C. 6295(o)(2)(B)). As part of this determination, DOE conducts a life-cycle cost (LCC) analysis, which models the combined impact of appliance first cost and operating cost changes on a representative commercial building sample to identify the fraction of customers achieving LCC savings or incurring net cost at the considered efficiency levels. Thus, the commercial discount rate value(s) used to calculate the present value of energy cost savings within the LCC model implicitly plays a role in estimating the economic impact of potential standard levels. This report provides an in-depth discussion of the commercial discount rate estimation process. It is an update to previous reports on estimating commercial discount rates from firm-level and sector-level financial data (e.g., Fujita, 2021, 2016). Major topics covered in this report include the following: -Discount rate estimation methods and rationale -Data sources used and data limitations -Discount rate distributions for use in standards analysis -Discount rate estimation methods and distributions specific to the small business subgroup analysis A version of this analysis was most recently released in 2022. Going forward, this report will be updated as data allow and analyses necessitate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling DOE Standard Canister Configurations with Updated Surface Chemistry

Road-ready and final disposition packaging configurations for the advanced test reactor (ATR) fuel currently specifies storage within helium backfilled DOE sealed standard canisters. The aluminum cladding of the ATR fuel contains an oxyhydroxide layer of boehmite/bayerite that generates hydrogen when subjected to irradiation. Understanding the effect of this hydrogen buildup over time to important for long term storage considerations. Previous modeling efforts have built a coupled CFD-chemical model to simulate the temperature gas phase concentrations within the DOE sealed standard canisters. These models have coupled the temperature conditions to both the gas phase radiolysis chemistry and the surface chemistry associated with the oxyhydroxide layer. Continued experimental work has identified trends for aluminum surrogate samples with oxyhydroxide layers for tests done at higher dose rates. At low initial doses a fast generation rate of hydrogen occurs which starts to roll over to a lower generation rate as the total dose applied in increased. A previous study created a small-scale chemical model was built to replicate a mini-canister surrogate system at SRNL as well as for the smaller capsule tests performed at INL. The previous iteration of the model utilized step function for its G-values for the hydrogen generation over a 200-year period. This model makes an update to the surface chemistry to account for theorized surface chemistry reactions allowing for oxygen to remain bounded to the oxyhydroxide layer. As additional experiments continue, the kinetic fits may be adjusted to adapt to new data. Three canister configurations are modeled – the base 18-inch, 15-foot DOR standard canister with 30 ATR fuel elements, an 18-inch, 10-foot DOE standard canister with 32 ATR fuel elements and a 24-inch, 10-foot DOE standard canister with 40 ATR fuel elements. In previous reports, the primary sensitivity of the canister conditions was identified as the decay heat of the fuel and the dried condition of the fuel. Only these parameters are studied in the report. For the nominal case with dried fuel, the hydrogen generation is only about 2%, so it is even less than the flammability limit if it were exposed to oxygen. For the densely packed 18-inch case the total hydrogen concentration is only around 4% with the nominal decay heat. For the densely packed 24-inch case the total hydrogen concentration is only 2.5%, roughly 20% higher than the original packing design, and still under flammability conditions if exposed to oxygen.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Commercial, industrial, and institutional discount rate estimation for efficiency standards analysis: Sector-level data 1998–2023

Underlying each of the U.S. Department of Energy’s (DOE’s) federal appliance and equipment energy conservation standards are a set of complex analyses of the projected costs and benefits of regulation. Any new or amended standard must be designed to achieve significant additional energy conservation, provided that it is technologically feasible and economically justified (42 U.S.C. 6295(o)(2)(A)). DOE determines economic justification based on whether the benefits exceed the burdens, considering a variety of factors, including the economic impact of the standard on consumers of the product and the savings in lifetime operating cost compared to any increase in price or maintenance expenses (42 U.S.C. 6295(o)(2)(B)). As part of this determination, DOE conducts a life-cycle cost (LCC) analysis, which models the combined impact of appliance first cost and operating cost changes on a representative commercial building sample to identify the fraction of customers achieving LCC savings or incurring net cost at the considered efficiency levels. Thus, the commercial discount rate value(s) used to calculate the present value of energy cost savings within the LCC model implicitly plays a role in estimating the economic impact of potential standard levels. This report provides an in-depth discussion of the commercial discount rate estimation process relying on the Capital Asset Pricing Model (CAPM) to estimate a business’ cost of equity, and by adding a risk adjustment factor to the risk-free rate associated with long-term U.S. Treasury bonds to estimate their cost of debt. It is an update to previous reports on estimating commercial discount rates from firm-level and sector-level financial data (e.g., Fujita, 2021, 2016). Major topics covered in this report include the following: • Discount rate estimation methods and rationale • Data sources used and data limitations • Discount rate distributions for use in standards analysis • Discount rate estimation methods and distributions specific to the small business subgroup analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Standardized Protocol for Real-Time APIs as Required by Title 23 CFR 680.116(c)

Improving the ability of drivers to easily locate working and available chargers is key to improving the public charging experience. Electric vehicle charging providers who are recipients of federal funds through the National Electric Vehicle Infrastructure (NEVI) Formula Program, Charging and Fueling Infrastructure (CFI) Discretionary Grant Program, and other funding programs as identified under Title 23 of the U.S. Code must deploy and maintain an application programming interface (API) to access information about charging stations they operate.1 This includes information about individual charging ports, pricing, and availability in accordance with the Federal Highway Administration’s National Electric Vehicle Infrastructure Standards and Requirements, 23 CFR 680.116(c), herein referred to as the minimum standards (Federal Highway Administration 2023). Specifically outlined in the minimum standards, states and other designated recipients are required to ensure that charging station information including location, connector type, power level, real-time status, and real-time price to charge are available free of charge to third-party software developers through an API. These requirements are intended to enable effective communication with consumers about available charging stations and help consumers make informed decisions about trip planning, including when and where to charge. This document provides a standardized protocol for how to structure data, data update frequency, and practices for making the data required to be shared via API usable for improving public transparency and the customer experience. These are recommendations only and do not modify the Federal Highway Administration’s minimum standards in any way.

33 ADVANCED PROPULSION SYSTEMS↗

Methods for Specifying Scientific Data Standards and Modeling Relationships with Applications to Neuroscience [Plus Supplementary Data]

Neuroscience continues to experience a tremendous growth in data; in terms of the volume and variety of data, the velocity at which data is acquired, and in turn the veracity of data. These challenges are a serious impediment to sharing of data, analyses, and tools within and across labs. Here, we introduce BRAINformat, a novel data standardization framework for the design and management of scientific data formats. The BRAINformat library defines application-independent design concepts and modules that together create a general framework for standardization of scientific data. We describe the formal specification of scientific data standards, which facilitates sharing and verification of data and formats. We introduce the concept of Managed Objects, enabling semantic components of data formats to be specified as self-contained units, supporting modular and reusable design of data format components and file storage. We also introduce the novel concept of Relationship Attributes for modeling and use of semantic relationships between data objects. Based on these concepts we demonstrate the application of our framework to design and implement a standard format for electrophysiology data and show how data standardization and relationship-modeling facilitate data analysis and sharing. The format uses HDF5, enabling portable, scalable, and self-describing data storage and integration with modern high-performance computing for data-driven discovery. The BRAINformat library is open source, easy-to-use, and provides detailed user and developer documentation and is freely available at: https://bitbucket.org/oruebel/brainformat.

60 APPLIED LIFE SCIENCES↗

Cybersecurity Certification Requirements for Distributed Energy Resources: A Survey of SunSpec Alliance Standards

This survey paper explores the cybersecurity certification requirements defined by the SunSpec Alliance for Distributed Energy Resource (DER) devices, focusing on aspects such as software updates, device communications, authentication mechanisms, device security, logging, and test procedures. The SunSpec cybersecurity standards mandate support for remote and automated software updates, secure communication protocols, stringent authentication practices, and robust logging mechanisms to ensure operational integrity. Furthermore, the paper discusses the implementation of the SAE J3072 standard using the IEEE 2030.5 protocol, emphasizing the secure interactions between electric vehicle supply equipment (EVSE) and plug-in electric vehicles (PEVs) for functionalities like vehicle-to-grid (V2G) capabilities. This research also examines the SunSpec Modbus standard, which enhances the interoperability among DER system components, facilitating compliance with grid interconnection standards. This paper also analyzes the existing SunSpec Device Information Models, which standardize data exchange formats for DER systems across communication interfaces. Finally, this paper concludes with a detailed discussion of the energy storage cybersecurity specification and the blockchain cybersecurity requirements as proposed by SunSpec Alliance.

Tsikteris, Sean (ORCID:0009000524202250)↗

Evolution of cool-roof standards in the United States

Roofs that have high solar reflectance and high thermal emittance stay cool in the sun. A roof with lower thermal emittance but exceptionally high solar reflectance can also stay cool in the sun. Substituting a cool roof for a noncool roof decreases cooling-electricity use, cooling-power demand, and cooling-equipment capacity requirements, while slightly increasing heating-energy consumption. Cool roofs can also lower citywide ambient air temperature in summer, slowing ozone formation and increasing human comfort. Provisions for cool roofs in energy-efficiency standards can promote the building- and climate-appropriate use of cool roofing technologies. Cool-roof requirements are designed to reduce building energy use, while energy-neutral cool-roof credits permit the use of less energy-efficient components (e.g., larger windows) in a building that has energy-saving cool roofs. Both types of measures can reduce the life-cycle cost of a building (initial cost plus lifetime energy cost). Since 1999, several widely used building energy-efficiency standards, including ASHRAE 90.1, ASHRAE 90.2, the International Energy Conservation Code, and California's Title 24 have adopted cool-roof credits or requirements. This paper reviews the technical development of cool-roof provisions in the ASHRAE 90.1, ASHRAE 90.2, and California Title 24 standards, and discusses the treatment of cool roofs in other standards and energy-efficiency programs. The techniques used to develop the ASHRAE and Title 24 cool-roof provisions can be used as models to address cool roofs in building energy-efficiency standards worldwide.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Peer Review of NRC Standardized Plant Analysis Risk Models

The Nuclear Regulatory Commission (NRC) Standardized Plant Analysis Risk (SPAR) Models underwent a Peer Review using ASME PRA standard (Addendum C) as endorsed by NRC in Regulatory Guide (RG) 1.200. The review was performed by a mix of industry probabilistic risk analysis (PRA) experts and NRC PRA experts. Representative SPAR models, one PWR and one BWR, were reviewed against Capability Category I of the ASME PRA standard. Capability Category I was selected as the basis for review due to the specific uses/applications of the SPAR models. The BWR SPAR model was reviewed against 331 ASME PRA Standard Supporting Requirements; however, based on the Capability Category I level of review and the absence of internal flooding and containment performance (LERF) logic only 216 requirements were determined to be applicable. Based on the review, the BWR SPAR model met 139 of the 216 supporting requirements. The review also generated 200 findings or suggestions. Of these 200 findings and suggestions 142 were findings and 58 were suggestions. The PWR SPAR model was also evaluated against the same 331 ASME PRA Standard Supporting Requirements. Of these requirements only 215 were deemed appropriate for the review (for the same reason as noted for the BWR). The PWR review determined that 125 of the 215 supporting requirements met Capability Category I or greater. The review identified 101 findings or suggestions (76 findings and 25 suggestions). These findings or suggestions were developed to identify areas where SPAR models could be enhanced. A process to prioritize and incorporate the findings/suggestions supporting requirements into the SPAR models is being developed. The prioritization process focuses on those findings that will enhance the accuracy, completeness and usability of the SPAR models.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Regulatory Reform to Promote Clean Energy: The Potential of Output-Based Emissions Standards

Barriers to industrial energy-efficient technologies hinder their use. A number of EPA analyses and industrial experts have found that the utilization of input-based emissions standards (measured in parts-per-million or pounds/MMBtu) in the Clean Air Act creates a regulatory barrier to the installation and deployment of technologies that emit fewer criteria pollutants and use energy more efficiently. Changing emission management strategies to an output-based emissions standard (measured in tons of pollutant emitted) is a way to ameliorate some of these barriers. Combined heat and power (CHP) is one of the key technologies that would see increased industrial application if the emissions standards were modified. Many states have made this change since the EPA first approved it in 2000, although direction from the Federal government could speed implementation modifications. To analyze the national impact of accelerated state adoption of output-based standards on CHP technologies, this paper uses detailed National Energy Modeling System (NEMS) and spreadsheet analysis illustrating two phased-in adoption scenarios for output-based emissions standards in the industrial sector. Benefit/cost metrics are calculated from a private and public perspective, and also a social perspective that considers the criteria and carbon air pollution emissions. These scenarios are compared to the reference case of AEO 2010 and are quite favorable, with a social benefit-cost ratio of 16.0 for a five-year phase-in scenario. In addition, the appropriateness of the Federal role, applicability, technology readiness, and administrative feasibility are discussed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

IEEE Smart Grid Series of Standards IEEE 2030 (Interoperability) and IEEE 1547 (Interconnection) Status: Preprint

The IEEE American National Standards smart grid publications and standards development projects IEEE 2030, which addresses smart grid interoperability, and IEEE 1547TM, which addresses distributed resources interconnection with the grid, have made substantial progress since 2009. The IEEE 2030TM and 1547 standards series focus on systems-level aspects and cover many of the technical integrationissues involved in a mature smart grid. The status and highlights of these two IEEE series of standards, which are sponsored by IEEE Standards Coordinating Committee 21 (SCC21), are provided in this paper.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Updated Combination of CDF and D0 Searches for Standard Model Higgs Boson Production with up to 10.0 fb$^{-1}$ of Data

We combine results from the CDF and D0 Collaborations on direct searches for the standard model (SM) Higgs boson (H) in ppbar collisions at the Fermilab Tevatron at sqrt(s)=1.96 TeV. Compared to the previous Tevatron Higgs boson search combination, more data have been included, additional channels have been incorporated, and some previously used channels have been reanalyzed to gain sensitivity. Searches are carried out for hypothesized Higgs boson masses between 100 and 200 GeV/c^2. With up to 10 fb-1 of luminosity analyzed, the 95% C.L. median expected upper limits on Higgs boson production are factors of 0.89, 1.08, and 0.48 times the values of the SM cross section for Higgs bosons of mass m_H=115 GeV/c^2, 125 GeV/c^2, and 165 GeV/c^2, respectively. In the absence of signal, we expect to exclude the regions 100<m_{H}<120 GeV/c^2 and 139<m_H<184 GeV/c^2. We exclude, at the 95% CL, two regions: 100<m_H<103 GeV/c^2, and 147<m_H<180 GeV/c^2. There is a significant excess of data events with respect to the background estimation in the mass range 115<m_H<140 GeV/c^2, which causes our observed limits to not be as stringent as expected. At m_H=120 GeV/c^2, the p-value for a background fluctuation to produce this excess is \sim1.5x10^-3, corresponding to a local significance of 3.0 standard deviations. The global significance for such an excess anywhere in the full mass range investigated is approximately 2.5 standard deviations. We also combine separately searches for H to bb and H to WW. We find that the excess is concentrated in the H to bb channel, appearing in the searches over a broad range of m_H. The maximum local significance of 3.2 standard deviations corresponds to a global significance of approximately 2.9 standard deviations. Our results in the H to WW channels are also consistent with the possible presence of a low-mass Higgs boson.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Draft Environmental Impact Statement for Proposed Energy Conservation Standards for Manufactured Housing

This draft environmental impact statement (EIS) analyzes the impacts related to DOE’s proposed energy conservation standards for manufactured homes. DOE’s proposed energy conservation standards are based on the 2021 International Energy Conservation Code (IECC) and relate to the building thermal envelope; air sealing; installation of insulation; duct sealing; heating, ventilation and air conditioning (HVAC); service hot water systems; mechanical ventilation fan efficacy; and heating and cooling equipment sizing. The draft EIS evaluates DOE’s proposed action (energy conservation standards tiered based the manufacturers retail list price), alternatives to the proposed action (including energy conservation standards tiered based on size of the manufactured home and untiered standards), and a no action alternative. The draft EIS presents analysis of impacts related to (1) energy resources; (2) air resources (including greenhouse gases, climate change, ambient air quality and indoor air quality); (3) health and safety; (4) socioeconomics; and (5) environmental justice.

MacDonell, Margaret↗

A performance standards approach to reducing CO{sub 2} emissions from electric power plants

The CO{sub 2} emission performance standard policies outlined in this paper could complement a cap-and-trade program that puts a price on carbon and serve to significantly reduce the CO{sub 2} emissions from coal use for electricity generation. Emission performance standards have a long history in the United States and have been successfully used to control emissions of various air pollutants from electric generators. This paper explores the rationale for using emission performance standards and describes the various types of performance standard policies. Emission performance standards that address CO{sub 2} emissions could promote the deployment of carbon capture and storage technology coupled with new and existing coal-fueled electric power plants. 28 refs., 4 figs., 4 tabs.

01 COAL, LIGNITE, AND PEAT↗