Search NASA⌕ Search

SEARCH · Search NASA

Results for “Test and analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Testing And Analysis Of Rubbing Of Turbine-Blade Tips

Unique combination of established techniques of experimentation and theoretical analysis devised to study stresses induced in turbine blades by intermittent or periodic rubbing of tips of blades in turbine housings. Rubbing is inevitable consequence of modern high-speed, high-efficiency turbine designs, which call for blade-tip clearances as small as possible. Necessary to quantify stresses caused by rubbing in order to predict fatigue lives of blades. Testing apparatus simulates blade-tip rubbing and measures dynamic responses of blades.

Davis, Gary A.↗

Nozzle Side Load Testing and Analysis at Marshall Space Flight Center

Realistic estimates of nozzle side loads, the off-axis forces that develop during engine start and shutdown, are important in the design cycle of a rocket engine. The estimated magnitude of the nozzle side loads has a large impact on the design of the nozzle shell and the engine s thrust vector control system. In 2004 Marshall Space Flight Center (MSFC) began developing a capability to quantify the relative magnitude of side loads caused by different types of nozzle contours. The MSFC Nozzle Test Facility was modified to measure nozzle side loads during simulated nozzle start. Side load results from cold flow tests on two nozzle test articles, one with a truncated ideal contour and one with a parabolic contour are provided. The experimental approach, nozzle contour designs and wall static pressures are also discussed

Ruf, Joseph H.↗

Europa Clipper Passive Thermal Control Valve Test and Analysis

Europa Clipper spacecraft utilizes passive thermal control valves (TCV) in an active thermal control system to maintain spacecraft component temperatures within their allowable limits. The single-phase mechanically pumped fluid loop recovers heat from the electronics and uses it to maintain propulsion system warm. When excess heat is dissipated the mixing valves direct the fluid to the radiator to reject this additional heat. The loop uses two mixing TCVs placed in series to modulate fluid flow and heat rejection rate from the radiator. This paper describes the thermal and hydraulic test results for Europa Clipper engineering model (EM) mixing valves. For the first time two heritage mixing valves previously developed for the Mars Science Laboratory (MSL) were placed in series to modulate flow to the radiator from 0.1% to 95% of full flow between temperature range of 4 oC to 24 oC. Individually, each mixing valve was able to modulate the flow from 2% to 96% of full flow between the temperatures of 4 oC and 24 oC. Pressure drop was measured between 1.5 to 3 psid depending on the temperature of the mixed fluid and the opening fraction of the valves. A methodology was developed, tested, and validated to adjust the setpoints with an accuracy of 0.1 oC. The measured flow splits were corrected for the effects of impedance due to the flow meters used to measure the flow rates. Finally, flow rate to the radiator increased linearly as a function of mixed temperature for individual valves, while it increased parabolically with temperature when two mixing valves were placed in series.

Mastropietro, AJ↗

Mars 2020 Coring Drill: Prototype Testing and Analysis

The Mars 2020 rover will carry a new subsystem to collect and prepare Martian rocks and regolith (loose, unconsolidated) samples. This includes a rotary percussive coring drill and a set of sample tubes. About 30 of these sample tubes will be deposited at select locations for return on a potential future sample-retrieval mission. In laboratories on Earth, specimens from Mars could be analyzed for evidence of past life on Mars and possible health hazards for future human missions. Hardware and control algorithms for the coring drill are based heavily on testing. Results from testing of prototype hardware are used to refine the design

Kreichbaum, Kristopher↗

Test and analysis results for composite transport fuselage and wing structures

Automated tow placement (ATP) and stitching of dry textile composite preforms followed by resin transfer molding (RTM) are being investigated by researchers at NASA LaRC and Douglas Aircraft Company as cost-effective manufacturing processes for obtaining damage tolerant fuselage and wing structures for transport aircraft. The Douglas work is being performed under a NASA contract entitled 'Innovative Composites Aircraft Primary Structures (ICAPS)'. Data are presented in this paper to assess the damage tolerance of ATP and RTM fuselage elements with stitched-on stiffeners from compression tests of impacted three-J-stiffened panels and from stiffener pull-off tests. Data are also presented to assess the damage tolerance of RTM wing elements which had stitched skin and stiffeners from impacted single stiffener and three blade-stiffened compression tests and stiffener pull-off tests.

Deaton, Jerry W.↗

Testing and Analysis of Grid Forming Inverter Control for Achieving Resilient and Economic Operation of an Islanded Microgrid

This investigation examines the feasibility of operating a battery energy storage system (BESS) in parallel with synchronous generation by using grid forming (GFM) control in order to achieve frequency control objectives while mitigating increases to operating costs in the context of an islanded microgrid. The BESS GFM control system, which is based on conventional droop techniques, is modeled along with the overall microgrid using the Real Time Digital Simulator (RTDS) to allow for integration of genset controller hardware. A series of simulations are performed to test the voltage and frequency regulation capability of the BESS control system when the primary frequency regulating genset is tripped offline. The results of the simulations suggest that the GFM control scheme will successfully maintain frequency and voltage stability, which will enable operation without a back-up genset while not compromising the microgrid resiliency to contingencies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic testing and analysis of extension-twist-coupled composite tubular spars

The results from a study aimed at improving the dynamic and aerodynamic characteristics of composite rotor blades through the use of extension-twist elastic coupling are presented. A set of extension-twist-coupled composite tubular spars, representative of the primary load carrying structure within a helicopter rotor blade, was manufactured using four plies of woven graphite/epoxy cloth 'prepreg.' These spars were non-circular in cross section design and were therefore subject to warping deformations. Three cross-sectional geometries were developed: square, D-shape, and flattened ellipse. Results from free-free vibration tests of the spars were compared with results from normal modes and frequency analyses of companion shell-finite-element models developed in MSC/NASTRAN. Five global or 'non-shell' modes were identified within the 0-2000 Hz range for each spar. The frequencies and associated mode shapes for the D-shape spar were correlated with analytical results, showing agreement within 13.8 percent. Frequencies corresponding to the five global mode shapes for the square spar agreed within 9.5 percent of the analytical results. Five global modes were similarly identified for the elliptical spar and agreed within 4.9 percent of the respective analytical results.

Lake, Renee C.↗

An Accelerated Testing and Analysis Framework for Qualification of Battery Materials

The continuously growing demand for batteries used within automotive, aviation, and grid applications has exacerbated the need to supplement critical battery material feedstocks, such as those for anode and cathode active materials. New or supplementary material sources, however, universally comprise unique material properties that can significantly affect the lifetime and performance of resultant batteries. As such, the influence of composition, microstructure, and morphology on electrochemical performance should be characterized quickly and accurately to accelerate commercialization of new material sources. This work introduces a tiered framework to quickly assess new material viability and understand the influence of physicochemical properties on battery performance. The Tier 1 testing described here is rapid and lower-effort to quickly recognize materials with fundamental flaws and potentially disqualify them. Later testing would require more time and effort but provide higher fidelity information with a goal of validating materials for specific applications. A case study examining various commercial sources of LiFePO4 (LFP) is presented, using Tier 1 of the protocol to identify rapid electrochemical and physicochemical signals that correlate with performance and to provide early go/no-go decisions on LFP materials without the need for long-term cycling data.

25 - ENERGY STORAGE↗

Test and Analysis of a Composite Conical-Cylindrical Shell

Launch-vehicle shell structures, which can be comprised of both cylindrical and conical sections, are known to be susceptible to buckling due to their large radius-to-thickness ratios. The advancements in composite manufacturing and numerical methods have enabled designers to consider more nontraditional shapes, such as connecting the conical and cylindrical sections with a toroidal transition to create a single-piece conical-cylindrical shell. This single-piece construction eliminates the need for a heavy interface ring between sections and has the potential to save mass. To better understand the buckling behavior, a composite conical-cylindrical shell was designed, fabricated, and tested. Prior to test, a finite element model that included thickness variations and radial imperfections was created. The test article buckled elastically at 251.8 kN, approximately 8.8% higher than the predicted buckling load of 231.4 kN Continued research in conical-cylindrical structures has the potential to expand the design space for launch-vehicle structures and lead to improved designs and reduced weight.

Buckling↗

Buckling Testing and Analysis of Honeycomb Sandwich Panel Arc Segments of a Full-Scale Fairing Barrel: 8-ply Out-of-Autoclave Facesheets - Part 3

Four honeycomb sandwich panels, representing 1/16th arc segments of a 10 m diameter barrel section of the heavy lift launch vehicle, were manufactured under the NASA Composites for Exploration program and the NASA Constellation Ares V program. Two configurations were chosen for the panels: 6-ply facesheets with 1.125 in. honeycomb core and 8-ply facesheets with 1.000 in. honeycomb core. Additionally, two separate carbon fiber/epoxy material systems were chosen for the facesheets: inautoclave IM7/977-3 and out-of-autoclave T40-800B/5320-1. Smaller 3- by 5-ft panels were cut from the 1/16th barrel sections. These panels were tested under compressive loading at the NASA Langley Research Center. Furthermore, linear eigenvalue and geometrically nonlinear finite element analyses were performed to predict the compressive response of the 3- by 5-ft panels. This manuscript summarizes the experimental and analytical modeling efforts pertaining to the panel composed of 8-ply, T40-800B/5320-1 facesheets (referred to as Panel C). To improve the robustness of the geometrically nonlinear finite element model, measured surface imperfections were included in the geometry of the model. Both the linear and nonlinear, two-dimensional (2-D) and three-dimensional (3-D), models yield good qualitative and quantitative predictions. Additionally, it was predicted correctly that the panel would fail in buckling prior to failing in strength.

heavy lift launch vehicles↗

Liquid Nitrogen (Oxygen Simulent) Thermodynamic Venting System Test Data Analysis

In designing systems for the long-term storage of cryogens in low gravity space environments, one must consider the effects of thermal stratification on excessive tank pressure that will occur due to environmental heat leakage. During low gravity operations, a Thermodynamic Venting System (TVS) concept is expected to maintain tank pressure without propellant resettling. The TVS consists of a recirculation pump, Joule-Thomson (J-T) expansion valve, and a parallel flow concentric tube heat exchanger combined with a longitudinal spray bar. Using a small amount of liquid extracted by the pump and passing it though the J-T valve, then through the heat exchanger, the bulk liquid and ullage are cooled, resulting in lower tank pressure. A series of TVS tests were conducted at the Marshall Space Flight Center using liquid nitrogen as a liquid oxygen simulant. The tests were performed at fill levels of 90%, 50%, and 25% with gaseous nitrogen and helium pressurants, and with a tank pressure control band of 7 kPa. A transient one-dimensional model of the TVS is used to analyze the data. The code is comprised of four models for the heat exchanger, the spray manifold and injector tubes, the recirculation pump, and the tank. The TVS model predicted ullage pressure and temperature and bulk liquid saturation pressure and temperature are compared with data. Details of predictions and comparisons with test data regarding pressure rise and collapse rates will be presented in the final paper.

Hedayat, A.↗

Analysis and testing of a new method for drop size and velocity measurements using laser light scatter interferometry

Drop size and velocity can be measured simultaneously using an optical system which is the same as a laser Doppler velocimeter except that three detectors are located at selected spacings behind the receiver aperture. Drops passing through the intersection of the two beams scatter light which produces an interferrence fringe pattern. The temporal frequency of the fringe pattern is the Doppler difference frequency which is linearly proportional to the drop velocity while the spatial frequency is linearly related to the drop diameter. The spacing of the fringes is also dependent upon the light wavelength, beam intersection angle, drop refractive index (unless reflected light is measured), and the location of the receiver. The theoretical analysis was verified, signal phase processing methods were evaluated, and the effects of signal quality upon the measurements were investigated.

Bachalo, W. D.↗

An Accelerated Testing and Analysis Framework for Qualification of Battery Materials Part I: A Case Study with LFP Cathodes

The growing demand for batteries used within automotive, aviation, and grid applications has exacerbated the need to supplement critical battery material feedstocks, such as those for anode and cathode active materials. New or supplementary material sources, however, universally comprise unique properties that can affect the lifetime and performance of resultant batteries. Even minor differences between new sources and established supplies can delay qualification, making it difficult for new suppliers to commercialize and resulting in a less resilient supply chain. Accordingly, the influence of composition, microstructure, and morphology on electrochemical performance should be characterized quickly and accurately to accelerate commercialization of new sources. This work introduces a tiered framework to assess new material viability and understand the influence of physicochemical properties on battery performance. The Tier 1 testing described here is rapid and low-effort to recognize materials with fundamental flaws and potentially disqualify them. Later testing would require more effort but provide higher-fidelity information with a goal of application-based validation. A case study examining commercial sources of LiFePO4 (LFP) is presented, using Tier 1 of the protocol to identify rapid electrochemical and physicochemical signals that correlate with performance and provide early go/no-go decisions for LFP materials without requiring long-term cycling.

25 ENERGY STORAGE↗

Characterization of Space Shuttle Thermal Protection System (TPS) Materials for Return-to-Flight following the Shuttle Columbia Accident Investigation

During the Space Shuttle Columbia Accident Investigation, it was determined that a large chunk of polyurethane insulating foam (= 1.67 lbs) on the External Tank (ET) came loose during Columbia's ascent on 2-1-03. The foam piece struck some of the protective Reinforced Carbon-Carbon (RCC) panels on the leading edge of Columbia's left wing in the mid-wing area. This impact damaged Columbia to the extent that upon re-entry to Earth, superheGed air approaching 3,000 F caused the vehicle to break up, killing all seven astronauts on board. A paper after the Columbia Accident Investigation highlighted thermal analysis testing performed on External Tank TPS materials (1). These materials included BX-250 (now BX-265) rigid polyurethane foam and SLA-561 Super Lightweight Ablator (highly-filled silicone rubber). The large chunk of foam from Columbia originated fiom the left bipod ramp of the ET. The foam in this ramp area was hand-sprayed over the SLA material and various fittings, allowed to dry, and manually shaved into a ramp shape. In Return-to-Flight (RTF) efforts following Columbia, the decision was made to remove the foam in the bipod ramp areas. During RTF efforts, further thermal analysis testing was performed on BX-265 foam by DSC and DMA. Flat panels of foam about 2-in. thick were sprayed on ET tank material (aluminum alloys). The DSC testing showed that foam material very close to the metal substrate cured more slowly than bulk foam material. All of the foam used on the ET is considered fully cured about 21 days after it is sprayed. The RTF culminated in the successful launch of Space Shuttle Discovery on 7-26-05. Although the flight was a success, there was another serious incident of foam loss fiom the ET during Shuttle ascent. This time, a rather large chunk of BX-265 foam (= 0.9 lbs) came loose from the liquid hydrogen (LH2) PAL ramp, although the foam did not strike the Shuttle Orbiter containing the crew. DMA testing was performed on foam samples taken fiom a simulated PAL ramp panel. It was found that the smooth rind on the foam facing the cable tray did significantly affect the properties of foam at the PAL ramp surface. The smooth rind increased the storage modulus E' of the foam as much as 20- 40% over a temperature range of -145 to 95 C. Because of foam loss fiom the PAL ramp, future Shuttle flights were grounded indefinitely to allow further testing to better understand foam properties. The decision was also made to remove foam from the LH2 PAL, ramp. Other RTF efforts prior to the launch of Discovery included

Wingard, Doug↗

Thermal Testing and Analysis of an Efficient High-Temperature Multi-Screen Internal Insulation

Conventional multi-layer insulations exhibit excellent insulation performance but they are limited to the temperature range to which their components reflective foils and spacer materials are compatible. For high temperature applications, the internal multi-screen insulation IMI has been developed that utilizes unique ceramic material technology to produce reflective screens with high temperature stability. For analytical insulation sizing a parametric material model is developed that includes the main contributors for heat flow which are radiation and conduction. The adaptation of model-parameters based on effective steady-state thermal conductivity measurements performed at NASA Langley Research Center (LaRC) allows for extrapolation to arbitrary stack configurations and temperature ranges beyond the ones that were covered in the conductivity measurements. Experimental validation of the parametric material model was performed during the thermal qualification test of the X-38 Chin-panel, where test results and predictions showed a good agreement.

Weiland, Stefan↗

Electromagnetic Compatibility Test and Analysis Campaign of NASA's Mars 2020 Rover

NASA's Mars 2020 Rover—with a launch window opening July 2020, and landing expected February 2021—has mission objectives to look for evidence of habitability, seek biosignatures of past life, collect and cache samples for possible future return to Earth, and prepare for future human missions. The Rover platform is similar to the previous Mars Science Laboratory (MSL) “Curiosity” rover that landed in 2012 but contains a new suite of scientific instruments and upgrades to existing functionality. The scientific payload includes a trio of chemical analysis tools (PIXL, SHERLOC, SuperCam), a ground penetrating radar (RIMFAX), an upgraded weather station (MEDA), upgraded high resolution camera (MastCam-Z), and an oxygen-producing experiment (MOXIE). These changes—along with new efficiency goals to operate more Rover subsystems concurrently and thus collect more science—presented new electromagnetic compatibility (EMC) challenges. In this paper, we will describe the campaign to ensure Mars 2020 mission success from an electromagnetic environment perspective: 1) confirming existing MSL heritage subsystems and EMC requirements were compatible with the new Mars 2020 mission objectives, 2) engaging with engineers and scientists early in the project to identify and evaluate risks before hardware assembly and performing ambitious risk reduction tests, 3) undertaking a comprehensive subsystem qualification test program based on tailored MIL-STD-461F requirements, occasionally leading to redesign, 4) synthesizing the data collected to perform detailed analyses toward the goal of making risk-informed decisions at a system level. The spacecraft has successfully completed all three planned system level tests, demonstrating self-compatibility with minimal impact to operations from electromagnetic interference in all mission phases.

Gonzales, Edward C↗

Surface effects on deuterium permeation through vanadium membranes

Dense vanadium-based membranes offer high permeability and perfect selectivity to hydrogen isotopes, maintain favorable neutronic properties, and are compatible with liquid metals such as PbLi. These properties make vanadium membranes a promising fusion fuel cycle technology for processes such as tritium extraction from PbLi and exhaust processing. Surface contamination has a deleterious effect on the gas-phase hydrogen permeation through vanadium, and the reported permeabilities range from 10 -14 to 10 -7 mol m -1 s -1 Pa -0.5 . Thin dense films of palladium applied to clean vanadium surfaces enable a consistently high hydrogen permeability. In this study, uncoated vanadium resulted in deuterium permeabilities ranging from 2.8 × 10 -11 to 6.4 × 10 -9 mol m -1 s -1 Pa -0.5 at 300 °C–700 °C, respectively. Post-test analysis revealed a VO x surface layer and VC x subsurface layer formed on the feed side, while the as-received surface oxide dissolved leaving a submonolayer oxide on the permeate surface. Furthermore, the Pd-coated V resulted in a maximum deuterium permeability of 2.1 × 10 -7 m -1 s -1 Pa -0.5 at 375 °C upon activation of the Pd surface by oxidation and reduction. The deuterium permeation declined upon heating to 500 °C due to intermetallic diffusion between the Pd and V. The Mo 2 C-coated V resulted in deuterium permeabilities ranging from 2.7 × 10 -10 to 1.8 × 10-9 at 500 °C–700 °C, respectively, and a post-test analysis found the carbon in the Mo 2 C layer had dissolved into the V near the interface.

13 HYDRO ENERGY↗

Analysis of PICA-NuSil at the Hypersonic Materials Environmental Test System (HyMETS)

Phenolic Impregnated Carbon Ablator (PICA) gained heritage during the stardust mission and is the baseline material for missions to Mars. The phenolic phase of PICA is friable, and therefore the surface is treated with a siloxane resin (NuSil) to mitigate the shedding of particulate matter. Historically, material response models have not accounted for the presence of this coating. Therefore, a test campaign was executed at the Hypersonic Materials Environmental Test System (HyMETS) to investigate the performance of NuSil under multiple heating rates and gas composition. Sphere-cone models were instrumented with thermocouples to measure the in-depth temperature response, and surface temperatures were monitored with a pyrometer. Furthermore, emission spectrometers were used to collect spectra from species emitting at the surface of the test article and the post-shock stagnation region. Post-test analysis suggests that the coating decomposes according to multiple stages. Inspection of silicon emission data reveals a rapid rise and decline in intensity within the first couple of seconds of testing, which is attributed to pyrolysis of NuSil. Pyrolysis is followed by a stagnation in silicon emission and surface temperature which are attributed to the formation of a thin layer of oxidation-resistant silicon oxycarbide. Moreover, the presence of the silicon oxycarbide layer significantly reduces the in-depth thermal response when compared to the baseline material. Eventually, the silicon oxycarbide layer decomposes via high-temperature reactions, which expose the underlying char layer to a highly reactive flow.

PICA-NuSil↗